EN 50325-1:2000
(Main)Industrial communications subsystem based on ISO 11898 (CAN) for controller-device interfaces - Part 1: General requirements
- BACK
- 29-Oct-2000
- 31-Dec-2002
- 43.180
- CLC/TC 65X
Industrial communications subsystem based on ISO 11898 (CAN) for controller-device interfaces - Part 1: General requirements
Standard exists in English only * Superseded by EN 50325-1:2002
Industrielles Kommunikationssubsystem basierend auf ISO 11898 (CAN) - Teil 1: Allgemeine Anforderungen
Industrial communications subsystem based on ISO 11898 (CAN) for controller-device interfaces - Part 1: General requirements
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-2001
Industrial communications subsystem based on ISO 11898 (CAN) for controller-
device interfaces - Part 1: General requirements
Industrial communications subsystem based on ISO 11898 (CAN) for controller-device
interfaces -- Part 1: General requirements
Industrielles Kommunikationssubsystem basierend auf ISO 11898 (CAN) -- Teil 1:
Allgemeine Anforderungen
Ta slovenski standard je istoveten z: EN 50325-1:2000
ICS:
35.240.50 Uporabniške rešitve IT v IT applications in industry
industriji
43.040.15 $YWRPRELOVNDLQIRUPDWLND Car informatics. On board
9JUDMHQLUDþXQDOQLãNLVLVWHPL computer systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...
This May Also Interest You
This European Standard applies to controller device interfaces that provide defined interfaces between low voltage switchgear, controlgear, control circuit devices, switching elements and controlling devices (e.g. programmable controllers, personal computers, etc.). It may also be applied for the interfacing of other devices and elements to a controller device interface. This standard specifies requirements for controllers and devices utilising these interfaces, including not only the communication protocol specification, but also associated relevant electrical and mechanical characteristics. It also specifies the electrical and EMC tests required to verify the performance of each controller device interface when connected to the appropriate controllers and devices. This part 1 establishes a consistent terminology and format for the subsequent interfaces. It also harmonises requirements of a general nature in order to reduce the need for testing to different standards, increase understanding and facilitate comparisons of controller device interface standards. Those requirements of the various controller device interface standards which can be considered as general have therefore been gathered in this part 1. In addition to meeting the specific requirements stated in this part 1, the controller device interfaces included in this standard are documented in the English language in accordance with the requirements specified in this part 1, are already in use in commercial products and running in industrial plants, are available in quantity and at low price, are available from several sources and commercialised openly, to satisfy the tests specified, amongst others, in EN 61000 4 2, EN 61000 4 3, EN 61000 4 4, EN 61000 4 5, and EN 61000 4 6 against the test levels specified in EN 50082 2, have appropriate mechanisms for transmission error detection, are open, widely accepted, well documented, stable and support inter operability, are complete and describe the necessary interfaces in sufficient detail to enable error free implementation, are free of any restriction related to testing the implementation. For each controller device interface only two documents are necessary to determine all requirements and tests: the general requirements of this standard, referred to as "part 1" in the relevant parts covering the various types of controller device interfaces; the relevant controller device interface standard hereinafter referred to as the "relevant controller device interface standard" or "controller device interface standard". The solutions described in this standard have been used for many years by industry to solve application requirements involving low voltage switchgear and controlgear. They are characterised by: their ability to power connected devices directly from the network; their ability to operate in harsh environments typified by those encountered at the machine level by controls in industrial applications; usage of the sophisticated medium access rules of CAN which allows both organisation of traffic based on user assigned priorities and efficient resolution of occasional access conflict; a wide range of exchange services allowing precise tailoring of data exchange to the actual application needs as well as simultaneous distribution of data to a selected set of connected devices; their capability to simultaneously support data acquisition, diagnostics, messaging and programming/configuration as required, amongst others, for systems interfacing controllers to low voltage switchgear and controlgear in industrial applications. NOTE The controller device interface standards currently part of this series are: EN 50325 2: DeviceNet EN 50325 3: Smart Distributed System (SDS) EN 50325-4: CANopen EN 50325-5 : Functional safety communication based on EN 50325-4
- Standard14 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2019
- 31-Oct-2022
- 43.180
- CLC/TC 65X
EN 50325-4 specifies the following particular requirements for CANopen: • requirements for interfaces between programmable controllers and devices with input/output capabilities; • normal service conditions for devices; • constructional and performance requirements.
- Standard115 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Dec-2002
- 30-Jun-2005
- 43.180
- CLC/TC 65X
This European Standard applies to controller device interfaces that provide defined interfaces between low voltage switchgear, controlgear, control circuit devices, switching elements and controlling devices (e.g. programmable controllers, personal computers, etc.). It may also be applied for the interfacing of other devices and elements to a controller device interface. This standard specifies requirements for controllers and devices utilising these interfaces, including not only the communication protocol specification, but also associated relevant electrical and mechanical characteristics. It also specifies the electrical and EMC tests required to verify the performance of each controller device interface when connected to the appropriate controllers and devices. This part 1 establishes a consistent terminology and format for the subsequent interfaces. It also harmonises requirements of a general nature in order to reduce the need for testing to different standards, increase understanding and facilitate comparisons of controller device interface standards. Those requirements of the various controller device interface standards which can be considered as general have therefore been gathered in this part 1. In addition to meeting the specific requirements stated in this part 1, the controller device interfaces included in this standard are documented in the English language in accordance with the requirements specified in this part 1, are already in use in commercial products and running in industrial plants, are available in quantity and at low price, are available from several sources and commercialised openly, to satisfy the tests specified, amongst others, in EN 61000 4 2, EN 61000 4 3, EN 61000 4 4, EN 61000 4 5, and EN 61000 4 6 against the test levels specified in EN 50082 2, have appropriate mechanisms for transmission error detection, are open, widely accepted, well documented, stable and support inter operability, are complete and describe the necessary interfaces in sufficient detail to enable error free implementation, are free of any restriction related to testing the implementation. For each controller device interface only two documents are necessary to determine all requirements and tests: the general requirements of this standard, referred to as "part 1" in the relevant parts covering the various types of controller device interfaces; the relevant controller device interface standard hereinafter referred to as the "relevant controller device interface standard" or "controller device interface standard". The solutions described in this standard have been used for many years by industry to solve application requirements involving low voltage switchgear and controlgear. They are characterised by: their ability to power connected devices directly from the network; their ability to operate in harsh environments typified by those encountered at the machine level by controls in industrial applications; usage of the sophisticated medium access rules of CAN which allows both organisation of traffic based on user assigned priorities and efficient resolution of occasional access conflict; a wide range of exchange services allowing precise tailoring of data exchange to the actual application needs as well as simultaneous distribution of data to a selected set of connected devices; their capability to simultaneously support data acquisition, diagnostics, messaging and programming/configuration as required, amongst others, for systems interfacing controllers to low voltage switchgear and controlgear in industrial applications. NOTE The controller device interface standards currently part of this series are: EN 50325 2: DeviceNet EN 50325 3: Smart Distributed System (SDS) EN 50325-4: CANopen EN 50325-5 : Functional safety communication based on EN 50325-4
- Standard14 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2019
- 31-Oct-2022
- 43.180
- CLC/TC 65X
EN 50325-4 specifies the following particular requirements for CANopen: • requirements for interfaces between programmable controllers and devices with input/output capabilities; • normal service conditions for devices; • constructional and performance requirements.
- Standard115 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Dec-2002
- 30-Jun-2005
- 43.180
- CLC/TC 65X
IEC 60947-5-7:2024 states the requirements for proximity devices that correspond to the scope of IEC 60947-5-2:2019 with analog output (PDAO) and/or a digital output to transmit a corresponding digital value representing the detected sensing input. These devices can provide additional parameters. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) New structure; b) Update and expansion of definitions on analog output properties; c) Expanded performance requirements on analog output; d) Update and new normative references; e) Update of EMC requirements; f) Harmonization with IEC 62828 series; g) Harmonization with IEC 62683 and IEC 61987 definitions; h) Harmonization with IEC 61131-2 requirements; i) Update of the Annex A (former Annex G), Example of the determination of the conformity; j) New Annex B, Overview tests and influence quantities; k) New Annex C, Additional requirements for proximity switches with analog output incorporating a built-in communication interface complying with IEC 61131-9; l) New Annex D, Main characteristics for proximity devices with analog output.
- Draft45 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60947-4-1:2023 is applicable to the following equipment: - electromechanical contactors and starters including motor protective switching devices (MPSD and IMPSD); - actuators of contactor relays; - contacts dedicated exclusively to the coil circuit of the contactor or the contactor relay; - dedicated accessories (e.g. dedicated wiring, dedicated latch accessory); intended to be connected to distribution circuits, motors circuits and other load circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC. This fifth edition cancels and replaces the fourth edition published in 2018. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) objective in the scope; b) instantaneous only motor protective switching device IMPSD (3.5.33); c) kinds of equipment (5.2.1); d) methods of overload protection of motors (5.2.6); e) adoption of the AC-7d from IEC 61095:2023 (in 5.4.2); f) separately mounted overload relay of a starter (in 5.7.3 b)); g) starter and contactor suitable for use downstream to basic drive module (6.1.2 w)); h) reference to IEC TS 63058 for environmental aspects (in 6.4); i) wiring subject to movement (in 8.1.3); j) use of voltage transient limiting device (8.1.18); k) accessible parts subject to temperature limits (in 8.2.2.3); l) reference to Annex X of IEC 60947-1:2020 for the co-ordination of MPSD with SCPD (8.2.5.4); m) reference to IEC TR 63216 with different EMC environments (8.3.1); n) reference to IEC TR 63201 for the embedded software design (8.4); o) reference to IEC TS 63208 for cybersecurity aspects (8.5); p) update and completion of the measurement method of the power consumption of the electromagnet (9.3.3.2.1.2); q) update of Annex C including rational about AC-3e; r) determination of the critical load current for photovoltaic applications (M.8.7).
- Draft179 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 62626-1:2023 is available as IEC 62626-1:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62626-1:2023 applies to enclosed switches-disconnectors with rated voltages up to 1 000 V AC for repair and maintenance work or cleaning work in load circuits. Devices within the scope of this document are switch-disconnectors in accordance with IEC 60947-3 with specific additional requirements. Enclosed switch-disconnectors in this document are suitable for isolation in accordance with the IEC 60947 series and are not equipped with means for remote control or automatic switching to avoid unexpected or accidental start. These devices are not used for operational switching, for example quick start and stop, jogging. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) update of this document based on IEC 60947-1:2020.
- Draft11 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Sep-2025
- 29.120.40
- 29.130.20
- 2014/35/EU
- M/511
- CLC/TC 121A
IEC 61095:2023 is available as IEC 61095:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61095:2023 applies to electromechanical air break contactors for household and similar purposes provided with main contacts intended to be connected to circuits the rated voltage of which does not exceed 440 V AC (between phases) with rated operational currents less than or equal to 63 A for utilization category AC-7a, and 32 A for utilization categories AC‑7b, AC‑7c and AC-7d (expressed in rated power), and rated conditional short-circuit current less than or equal to 6 kA. This third edition cancels and replaces the second edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of requirements for screwless terminals; b) addition of requirements for the switching of LED lamps. Contactors for domestic and similar applications can be used for controlling lighting loads which is increasingly using LED lamp technology. A specific category for contactors is created: AC-7d. Requirements and tests are added to cover this market development, mainly for making and breaking and conventional operational performance; c) addition of requirements for contactors with electronically controlled electromagnet. Household contactors with electronically controlled electromagnet are available for years on the market. To fully cover such device, requirements and tests are added, dealing mainly with operating limits, behaviour in abnormal conditions, breakdown of components, EMC tests, etc. d) embedded software. More and more contactors are incorporating electronic circuits with embedded software. A reference is provided to guide the design of the software.
- Draft141 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60931-1:2025 is applicable to both non-self-healing capacitor units and non-self-healing capacitor banks intended to be used, particularly, for power-factor correction of AC power systems having a rated voltage up to and including 1 000 V and frequencies 15 Hz to 60 Hz. This document also applies to capacitors intended for use in power filter circuits.
- Standard43 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 63402-1:2025 specifies general requirements and the architecture between the Point of Common Coupling (PCC) and smart devices (SD) operating within the Smart Grid premises-side system (i.e. residential or commercial but not industrial premises). This document does not include requirements for: - safety - electromagnetic compatibility (EMC); - data security, as it is assumed that the underlying protocols will take the data security aspect into account - special equipment (e.g. legacy heat pumps) with a direct physical connection to the grid, as such equipment bypasses the customer energy manager (CEM) and is not HBES/BACS enabled (covered by other standards than the IEC 63402 series). This group EE publication is primarily intended to be used as an EE standard for the products mentioned in the scope, but is also intended to be used by TCs in the preparation of publications for products which are included in the boundary mentioned in the scope of this document. It has the status of a group energy efficiency publication in accordance with IEC Guide 118.
- Standard35 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-Aug-2025
- 03.100.70
- 27.015
- 29.020
- CLC/TC 205
Questions, Comments and Discussion