EN 50325-1:2000
(Main)Industrial communications subsystem based on ISO 11898 (CAN) for controller-device interfaces - Part 1: General requirements
- BACK
- 29-Oct-2000
- 31-Dec-2002
- 43.180
- CLC/TC 65X
Industrial communications subsystem based on ISO 11898 (CAN) for controller-device interfaces - Part 1: General requirements
Standard exists in English only * Superseded by EN 50325-1:2002
Industrielles Kommunikationssubsystem basierend auf ISO 11898 (CAN) - Teil 1: Allgemeine Anforderungen
Industrial communications subsystem based on ISO 11898 (CAN) for controller-device interfaces - Part 1: General requirements
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-2001
Industrial communications subsystem based on ISO 11898 (CAN) for controller-
device interfaces - Part 1: General requirements
Industrial communications subsystem based on ISO 11898 (CAN) for controller-device
interfaces -- Part 1: General requirements
Industrielles Kommunikationssubsystem basierend auf ISO 11898 (CAN) -- Teil 1:
Allgemeine Anforderungen
Ta slovenski standard je istoveten z: EN 50325-1:2000
ICS:
35.240.50 Uporabniške rešitve IT v IT applications in industry
industriji
43.040.15 $YWRPRELOVNDLQIRUPDWLND Car informatics. On board
9JUDMHQLUDþXQDOQLãNLVLVWHPL computer systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...
This May Also Interest You
This European Standard applies to controller device interfaces that provide defined interfaces between low voltage switchgear, controlgear, control circuit devices, switching elements and controlling devices (e.g. programmable controllers, personal computers, etc.). It may also be applied for the interfacing of other devices and elements to a controller device interface. This standard specifies requirements for controllers and devices utilising these interfaces, including not only the communication protocol specification, but also associated relevant electrical and mechanical characteristics. It also specifies the electrical and EMC tests required to verify the performance of each controller device interface when connected to the appropriate controllers and devices. This part 1 establishes a consistent terminology and format for the subsequent interfaces. It also harmonises requirements of a general nature in order to reduce the need for testing to different standards, increase understanding and facilitate comparisons of controller device interface standards. Those requirements of the various controller device interface standards which can be considered as general have therefore been gathered in this part 1. In addition to meeting the specific requirements stated in this part 1, the controller device interfaces included in this standard are documented in the English language in accordance with the requirements specified in this part 1, are already in use in commercial products and running in industrial plants, are available in quantity and at low price, are available from several sources and commercialised openly, to satisfy the tests specified, amongst others, in EN 61000 4 2, EN 61000 4 3, EN 61000 4 4, EN 61000 4 5, and EN 61000 4 6 against the test levels specified in EN 50082 2, have appropriate mechanisms for transmission error detection, are open, widely accepted, well documented, stable and support inter operability, are complete and describe the necessary interfaces in sufficient detail to enable error free implementation, are free of any restriction related to testing the implementation. For each controller device interface only two documents are necessary to determine all requirements and tests: the general requirements of this standard, referred to as "part 1" in the relevant parts covering the various types of controller device interfaces; the relevant controller device interface standard hereinafter referred to as the "relevant controller device interface standard" or "controller device interface standard". The solutions described in this standard have been used for many years by industry to solve application requirements involving low voltage switchgear and controlgear. They are characterised by: their ability to power connected devices directly from the network; their ability to operate in harsh environments typified by those encountered at the machine level by controls in industrial applications; usage of the sophisticated medium access rules of CAN which allows both organisation of traffic based on user assigned priorities and efficient resolution of occasional access conflict; a wide range of exchange services allowing precise tailoring of data exchange to the actual application needs as well as simultaneous distribution of data to a selected set of connected devices; their capability to simultaneously support data acquisition, diagnostics, messaging and programming/configuration as required, amongst others, for systems interfacing controllers to low voltage switchgear and controlgear in industrial applications. NOTE The controller device interface standards currently part of this series are: EN 50325 2: DeviceNet EN 50325 3: Smart Distributed System (SDS) EN 50325-4: CANopen EN 50325-5 : Functional safety communication based on EN 50325-4
- Standard14 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2019
- 31-Oct-2022
- 43.180
- CLC/TC 65X
EN 50325-4 specifies the following particular requirements for CANopen: • requirements for interfaces between programmable controllers and devices with input/output capabilities; • normal service conditions for devices; • constructional and performance requirements.
- Standard115 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Dec-2002
- 30-Jun-2005
- 43.180
- CLC/TC 65X
This European Standard applies to controller device interfaces that provide defined interfaces between low voltage switchgear, controlgear, control circuit devices, switching elements and controlling devices (e.g. programmable controllers, personal computers, etc.). It may also be applied for the interfacing of other devices and elements to a controller device interface. This standard specifies requirements for controllers and devices utilising these interfaces, including not only the communication protocol specification, but also associated relevant electrical and mechanical characteristics. It also specifies the electrical and EMC tests required to verify the performance of each controller device interface when connected to the appropriate controllers and devices. This part 1 establishes a consistent terminology and format for the subsequent interfaces. It also harmonises requirements of a general nature in order to reduce the need for testing to different standards, increase understanding and facilitate comparisons of controller device interface standards. Those requirements of the various controller device interface standards which can be considered as general have therefore been gathered in this part 1. In addition to meeting the specific requirements stated in this part 1, the controller device interfaces included in this standard are documented in the English language in accordance with the requirements specified in this part 1, are already in use in commercial products and running in industrial plants, are available in quantity and at low price, are available from several sources and commercialised openly, to satisfy the tests specified, amongst others, in EN 61000 4 2, EN 61000 4 3, EN 61000 4 4, EN 61000 4 5, and EN 61000 4 6 against the test levels specified in EN 50082 2, have appropriate mechanisms for transmission error detection, are open, widely accepted, well documented, stable and support inter operability, are complete and describe the necessary interfaces in sufficient detail to enable error free implementation, are free of any restriction related to testing the implementation. For each controller device interface only two documents are necessary to determine all requirements and tests: the general requirements of this standard, referred to as "part 1" in the relevant parts covering the various types of controller device interfaces; the relevant controller device interface standard hereinafter referred to as the "relevant controller device interface standard" or "controller device interface standard". The solutions described in this standard have been used for many years by industry to solve application requirements involving low voltage switchgear and controlgear. They are characterised by: their ability to power connected devices directly from the network; their ability to operate in harsh environments typified by those encountered at the machine level by controls in industrial applications; usage of the sophisticated medium access rules of CAN which allows both organisation of traffic based on user assigned priorities and efficient resolution of occasional access conflict; a wide range of exchange services allowing precise tailoring of data exchange to the actual application needs as well as simultaneous distribution of data to a selected set of connected devices; their capability to simultaneously support data acquisition, diagnostics, messaging and programming/configuration as required, amongst others, for systems interfacing controllers to low voltage switchgear and controlgear in industrial applications. NOTE The controller device interface standards currently part of this series are: EN 50325 2: DeviceNet EN 50325 3: Smart Distributed System (SDS) EN 50325-4: CANopen EN 50325-5 : Functional safety communication based on EN 50325-4
- Standard14 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2019
- 31-Oct-2022
- 43.180
- CLC/TC 65X
EN 50325-4 specifies the following particular requirements for CANopen: • requirements for interfaces between programmable controllers and devices with input/output capabilities; • normal service conditions for devices; • constructional and performance requirements.
- Standard115 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Dec-2002
- 30-Jun-2005
- 43.180
- CLC/TC 65X
IEC 60730-2-6:2025 applies to automatic electrical pressure sensing controls • for use in, on, or in association with equipment for household appliance and similar use; NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "controls" means "pressure sensing controls". • for building automation within the scope of ISO 16484 series and IEC 63044 series (HBES/BACS); EXAMPLE 1 Independently mounted automatic electrical pressure sensing controls, controls in smart grid systems and controls for building automation systems within the scope of ISO 16484-2. • for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications; EXAMPLE 2 Automatic electrical pressure sensing controls for commercial catering, heating and air-conditioning equipment. • that are smart enabled automatic electrical pressure sensing controls; EXAMPLE 3 Smart grid automatic electrical pressure sensing controls, remote interfaces/control of energy-consuming equipment including computer or smart phone. • that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC; • used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof; • utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs; • using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J; • that are mechanically or electrically operated, responsive to or controlling a pressure or vacuum; • as well as manual controls when such are electrically and/or mechanically integral with automatic controls. NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1. This document is also applicable to individual pressure sensing controls utilized as part of a control system or pressure sensing controls which are mechanically integral with multi-functional controls having non-electrical outputs. This document is also applicable to pressure sensing controls for appliances within the scope of IEC 60335-1. This document applies to - the inherent safety of pressure sensing controls, and - functional safety of pressure sensing controls and safety related systems, - pressure sensing controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system, - the operating values, operating times, and operating sequences where such are associated with equipment safety. This document specifies the requirements for construction, operation and testing of automatic electrical controls used in, on, or in association with an equipment. This document does not • apply to pressure sensing controls intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. However, this document can be applied to evaluate automatic electrical controls intended specifically for industrial applications in cases where no relevant safety standard exists; • take into account the response value of an automatic action of a pressure sensing control, if such a response value is dependent upon
- Draft38 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft4 pagesEnglish languagesale 10% offe-Library read for×1 day
- 02-Oct-2025
- 33.100.20
- 2014/30/EU
- M/490
- CLC/TC 210
IEC 62453-1:2025 is available as IEC 62453-1:2025 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62453-1:2025 presents an overview and guidance for the IEC 62453 series. It • explains the structure and content of the IEC 62453 series (see Clause 5); • provides explanations of some aspects of the IEC 62453 series that are common to many of the parts of the series; • describes the relationship to some other standards; • provides definitions of terms used in other parts of the IEC 62453 series. This third edition cancels and replaces the first edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) introduction of a new implementation technology (defined in IEC TS 62453-43); b) introduction of an OPC UA information model for FDT (defined in IEC 62453-71).
- Draft51 pagesEnglish languagesale 10% offe-Library read for×1 day
- 02-Oct-2025
- 25.040.40
- 35.100.05
- 35.110
- CLC/TC 65X
IEC 63522-21:2025 This part is used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use. This document defines a standard test method for evaluation of resistance against high temperature for long periods.
- Draft11 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 63208:2025 This document applies to the main functions of switchgear and controlgear and their assemblies, called equipment, in the context of operational technology (OT 3.1.34). It is applicable to equipment with wired or wireless data communication means and their physical accessibility, within their limits of environmental conditions. It is intended to achieve the appropriate physical and cybersecurity mitigation against vulnerabilities to security threats. This document provides requirements on the appropriate: – security risk assessment to be developed including the attack levels, the typical threats, the impact assessment and the relationship with safety; – levels of exposure of the communication interface and the determination of the equipment security level; – assessment of the exposure level of the communication interfaces; – assignment of the required security measures for the equipment; – countermeasures for the physical access and the environment derived from ISO/IEC 27001; – countermeasures referring to IEC 62443-4-2 with their criteria of applicability; – user instructions for installation, operation and maintenance; – conformance verification and testing, and – security protection profiles by family of equipment (Annex E to Annex I). In particular, it focuses on potential vulnerabilities to threats resulting in: – unintended operation, which can lead to hazardous situations; – unavailability of the protective functions (overcurrent, earth fault, etc.); – other degradation of main function. It also provides guidance on the cybersecurity management with the: – roles and responsibilities (Table 4); – typical architectures (Annex A); – use cases (Annex B); – development methods (Annex C); – recommendations to be provided to users and for integration into an assembly (Annex D); – bridging references to cybersecurity management systems (Annex K). This document does not cover security requirements for: – information technology (IT); – industrial automation and control systems (IACS), engineering workstations and their software applications; – critical infrastructure or energy management systems; – network device (communication network switch or virtual private network terminator), or – data confidentiality other than for critical security parameters; – design lifecycle management. For this aspect, see IEC 62443-4-1, ISO/IEC 27001 or other security lifecycle management standards.
- Draft129 pagesEnglish languagesale 10% offe-Library read for×1 day
- 02-Oct-2025
- 29.130.20
- CLC/SR 121
IEC 60794-1-214:2025 defines the test procedure used to measure the ability of cable sheath materials to maintain their integrity when exposed to ultraviolet (UV) radiation due to sunlight or fluorescent light. This first edition cancels and replaces Method F14 of the second edition of IEC 60794‑1‑22 published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60794‑1‑22:2017: a) addition of subclause as regards conditioning according to ISO 4892-2 or ISO 4892-3 for indoor-outdoor cables.
- Draft9 pagesEnglish languagesale 10% offe-Library read for×1 day
- 02-Oct-2025
- 33.180.10
- CLC/TC 86A
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.