HD 391 S3:1988
(Main)Dimensions for the mounting of single-hole, bush-mounted, spindle-operated electronic components
- BACK
- 17-Apr-1988
- CLC/SR 23J
Dimensions for the mounting of single-hole, bush-mounted, spindle-operated electronic components
Specifies mounting dimensions for spindle-operated, single-hole, bush-mounted components including switches, potentiometers and variable capacitors, primarily intended for use in equipment for telecommunications and in electronic devices employing similar techniques.
Maße für Gewindebuchsen für wellenbetätigte elektrisch-mechanische Bauelement mit Zentralbefestigung
Dimensions concernant le montage des axes de commande des composants électroniques montés par le canon sur trou unique et munis d'un axe de commande
Spécifie les dimensions des axes de commande des composants munis d'un axe de commande et montés par le canon sur trou unique, y compris les interrupteurs, les potentiomètres et les condensateurs variables destinés principalement à l'emploi dans les équipements de télécommunication et dans les dispositifs électroniques utilisant des techniques analogues.
Dimensions for the mounting of single-hole, bush-mounted, spindle-operated electronic components
General Information
Standards Content (Sample)
SLOVENSKI SIST HD 391 S3:2003
STANDARD
marec 2003
Dimensions for the mounting of single-hole, bush-mounted, spindle-operated
electronic components
ICS 31.240 Referenčna številka
...
This May Also Interest You
- Draft10 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the main characteristics of the voltage at a network user's supply terminals in public low voltage, medium, high, and extra-high voltage AC electricity networks under normal operating conditions. This document specifies the limits or values within which the voltage characteristics can be expected to remain at any supply terminal in public European electricity networks, only. Industrial networks are excluded from the scope of EN 50160. NOTE 1 If non-public networks (e.g. residential quarters, energy communities, office centres, shopping centres) have similar end-users as public networks, it is strongly advised to apply the same requirements as for public networks. This document does not apply under abnormal operating conditions, including the following: a) a temporary supply arrangement to keep network users supplied during conditions arising as a result of a fault, maintenance and construction work, or to minimize the extent and duration of a loss of supply; b) in the case of non-compliance of a network user's installation or equipment with the relevant standards or with the technical requirements for connection, established either by the public authorities or the network operator, including the limits for the emission of conducted disturbances; NOTE 2 A network user’s installation can include load and generation. c) in exceptional situations, in particular: 1) exceptional weather conditions and other natural disasters; 2) third party interference; 3) acts by public authorities, 4) industrial actions (subject to legal requirements); 5) force majeure; 6) power shortages resulting from external events. The voltage characteristics given in this document refer to conducted disturbances in public electric power networks. They are not intended to be used as electromagnetic compatibility (EMC) levels or product emission limits. Power quality is related to EMC in several ways - especially because compliance with power quality requirements depends on the control of cumulative effect of electromagnetic emissions from all/multiple equipment and/or installations. Therefore, the voltage characteristics given in this document gives guidance for specifying requirements in equipment product standards and in installation standards. NOTE 3 The performance of equipment might be impaired if it is subjected to supply conditions which are not specified in the equipment product standard. NOTE 4 This document can be superseded in total or in part by the terms of a contract between the individual network user and the network operator. The sharing of complaint management and problem mitigation costs between the involved parties is outside the scope of EN 50160. Measurement methods to be applied in this document are described in EN 61000-4-30.
- Draft7 pagesEnglish languagesale 10% offe-Library read for×1 day
This part of IEC 61557 specifies the requirements for measuring equipment that combines several measuring functions or methods of testing, measuring or monitoring, that are in accordance with the respective parts of IEC 61557, into one piece of apparatus. Measuring equipment which combines measuring functions or methods of testing, measuring or monitoring covered by the respective parts of IEC 61557 with those not covered by the respective parts of IEC 61557 is also within the scope of this document.
- Draft9 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60688:2024 applies to transducers (TRD) with electrical inputs and outputs for making measurements of AC or DC electrical quantities. The output signal can be in the form of an analogue or digital signal. This document applies to measuring transducers used for converting electrical quantities such as: – current, – voltage, – active power, – reactive power, – power factor, – phase angle, – frequency, – harmonics or total harmonic distortion, – apparent power, and – DC power to an output signal. This document applies a) if the fundamental frequency of the input(s) lies between 0 Hz and 1 500 Hz, b) to the electrical measuring transducer if it is part of a system for the measurement of an electrical or non-electrical quantity, c) to transducers for use in a variety of applications such as telemetry and process control and in one of a number of defined environments. This document is not applicable for: – instrument transformers that comply with IEC 61869 (all parts), – transmitters for use in an industrial process application that comply with IEC 60770 (all parts), – power metering and monitoring devices (PMD) that comply with IEC 61557-12, – meters that comply with the IEC 62053 series, – handheld sensors, – residual current monitoring devices (RCMs) that comply with IEC 62020-1, – residual current detecting devices (RDC-DD) that comply with IEC 62955, – in-cable control and protection devices (IC-CPDs) that comply with IEC 62752, – modular residual current devices (MRCDs) that comply with IEC 60947 2:2016/AMD1:2019, Annex M. Within the measuring range, the output signal is a function of the measurand. An auxiliary supply can be required. This document is intended: – to specify the terminology and definitions relating to transducers whose main application is in industry, – to unify the test methods used in evaluating transducer performance, – to specify accuracy limits and output values for transducers. IEC 60688:2024 cancels and replaces the fourth edition published in 2021. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) updating normative references; b) updating definitions; c) updating structure; d) adding DC power measurement.
- Draft124 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 62974-1:2024 specifies product and performance requirements for devices that fall under the heading of "monitoring and measuring systems used for data collection, aggregation and analysis", for industrial, commercial, and similar use rated below or equal to 1 kV AC and 1,5 kV DC. These devices are fixed and are intended to be used indoors as panel-mounted devices, or as modular devices fixed on a DIN rail, or as housing devices fixed on a DIN rail, or as devices fixed by other means inside a cabinet. These devices are used to upload or download information (energy measured on loads, power metering and monitoring data, temperature information, etc.), mainly for energy efficiency purposes. These devices are known as energy servers (ESE), energy data loggers (EDL), data gateways (DGW) and I/O data concentrators (IODC) and are grouped together under the family name of Data Management Devices (DMD). This document does not cover: • devices used only in the consumer market (living quarters) or household; • devices used in the smart metering infrastructure (e.g. smart meters); • devices used in the smart grid infrastructure; • devices used as IT servers in the information technology business; • power metering and monitoring devices (PMD); • I/O data concentrators already covered by a specific product standard; • communication protocols and interoperability; • power quality instruments (PQI); • software used for the data collection and analysis of the power quality for the supply side. IEC 62974-1:2024 cancels and replaces the first edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) the performance criteria have been reviewed; b) EMC and safety requirements have been improved; c) mechanical requirements have been clarified and amended.
- Draft30 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft3 pagesEnglish languagesale 10% offe-Library read for×1 day
These supplementary requirements apply to fuse-links for the protection of batteries and battery systems, including, but not limited to terminology, for electricity storage in equipment for circuits of nominal voltages up to 1 500 V d.c. Their rated voltage may be higher than 1 500 V d.c. The object of these supplementary requirements is to establish the characteristics of Battery fuse-links in such a way that they can be replaced by other fuse-links having the same characteristics, provided that their dimensions are identical.
- Draft14 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2024
- 29.120.50
- 2014/35/EU
- M/511
- CLC/SR 32B
IEC 63261:2024 provides requirements for the E&I objects of a digital 3D plant model, used in the engineering phase to design and construct a process plant and its instrumentation. It provides guidance how to model plants and their electrical and instrumentation equipment. This document also specifies the content and the possible output of the 3D plant model at project milestones. This document can be used by the contractual partners to agree upon the content of the 3D plant model to be delivered at specified milestones. This document does not specify the transfer and format of digital 3D plant models. This document does not specify definitions or instructions to equipment representations and details of elements in the 3D plant model not belonging to electrical and instrumentation domains.
- Draft9 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2024
- 25.040.40
- CLC/TC 65X
IEC 61442:2023 is available as IEC 61442:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61442:2023 specifies the test methods applicable for type testing accessories for power cables with rated voltages from 3,6/6 (7,2) kV up to 18/30 (36) kV. The test methods specified in this document apply to accessories for extruded and paper insulated cables according to IEC 60502-2 and IEC 60055-1 respectively.
- Draft36 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft6 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2024
- 29.120.50
- 2014/35/EU
- M/511
- CLC/SR 32B