Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz

Establishes a common and reproducible basis for testing electrical and electronic equipment with the application of common mode disturbances to power supply, control, signal and communication ports. This standard defines test voltage and current waveform, range of test levels, test equipment, test set-up and test procedures. The test is intended to demonstrate the immunity of electrical and electronic equipment when subjected to conducted, common mode disturbances such as those originating from power line currents and return leakage currents in the earthing/grounding system.

Elektromagnetische Verträglichkeit (EMV) - Teil 4-16: Prüf- und Meßverfahren - Prüfung der Störfestigkeit gegen leitungsgeführte, asymetrische Störgrößen im Frequenzbereich von 0 Hz bis 150 kHz

Compatibilité électromagnétique (CEM) - Partie 4-16: Techniques d'essai et de mesure - Essai d'immunité aux perturbations conduites en mode commun dans la gamme de fréquences de 0 Hz à 150 kHz

Etablit une base commune et reproductible destinée à essayer les performances des matériels électriques et électroniques lorsque ceux-ci sont soumis à des perturbations par conduction en mode commun, appliquées aux accès d'alimentation, de commande, de signal et de communication. La présente norme définit la tension d'essai et la forme du courant, les plages de niveaux d'essai, le matériel d'essai, le circuit d'essai et les procédures d'essai. L'essai vise à démontrer l'immunité des matériels électriques et électroniques soumis à des perturbations de conduction en mode commun telles que celles provenant des courants de ligne d'alimentation et des retours de courants de fuite dans les dispositifs de mise à la terre/à la masse.

Elektromagnetna združljivost (EMC) – 4-16. del: Preskušanje in merilne tehnike - Preskušanje odpornosti proti prevajanim motnjam skupne zvrsti v frekvenčnem območju od 0 Hz do 150 kHz (IEC 61004-16:1998)

General Information

Status
Withdrawn
Publication Date
12-Feb-1998
Withdrawal Date
30-Sep-1998
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
13-Jan-2019
Completion Date
13-Jan-2019

Relations

Buy Standard

Standard
EN 61000-4-16:1999
English language
28 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.UHNYHQþQHPElektromagnetische Verträglichkeit (EMV) -- Teil 4-16: Prüf- und Meßverfahren - Prüfung der Störfestigkeit gegen leitungsgeführte, asymetrische Störgrößen im Frequenzbereich von 0 Hz bis 150 kHzCompatibilité électromagnétique (CEM) -- Partie 4-16: Techniques d'essai et de mesure - Essai d'immunité aux perturbations conduites en mode commun dans la gamme de fréquences de 0 Hz à 150 kHzElectromagnetic compatibility (EMC) -- Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz (IEC 61004-16:1998)33.100.20ImunostImmunityICS:Ta slovenski standard je istoveten z:EN 61000-4-16:1998SIST EN 61000-4-16:1999en01-april-1999SIST EN 610
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.