HD 557 S1:1990
(Main)Binary direct voltage signals for process measurement and control systems
- BACK
- 14-Dec-1990
- 14-Jun-1991
- CLC/TC 65X
Binary direct voltage signals for process measurement and control systems
Applies to non-multiplexed two wire binary direct voltage signals of nominal 24 V level that are used in industrial-process measurement and control systems to transmit information between elements of systems.
Binäres Gleichspannungssignal für Meß-, Regel- und Steuersysteme der industriellen Prozeßtechnik
Signaux logiques de mesure et de commande dans les processus industriels
S'applique aux signaux logiques en tension continue d'un niveau nominal de 24 V, non multiplexés et transmis par deux fils, utilisés dans les systèmes de mesure et de commande de processus industriels pour transmettre l'information entre les éléments du système.
Binary direct voltage signals for process measurement and control systems
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST HD 557.S1:2002
01-julij-2002
Binary direct voltage signals for process measurement and control systems
Binary direct voltage signals for process measurement and control systems
Binäres Gleichspannungssignal für Meß-, Regel- und Steuersysteme der industriellen
ProzeßtechnikSignaux logiques de mesure et de commande dans les processus industriels
Ta slovenski standard je istoveten z: HD 557 S1:1990
ICS:
25.040.40 Merjenje in krmiljenje Industrial process
industrijskih postopkov measurement and control
SIST HD 557.S1:2002 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------SIST HD 557.S1:2002
---------------
...
This May Also Interest You
This document describes the procedure and rules for extended application of results of tests carried out according to the test methods described in EN 50399, EN 60332 1 2 and EN 61034 2. The EXAP rules described apply to EN 50399 test results used for classification according to EN 13501 6 in classes B2ca, Cca and Dca, additional smoke production classes s1, s2 and s3 and flaming droplets/particles, to EN 60332 1 2 test results used for classification in classes B2ca, Cca, Dca and Eca and to EN 61034 2 test results used for classification in classes s1a and s1b. No EXAP procedure and rules have been developed in respect to the results of tests carried out according to the test method described in EN 60754 2. As the parameters (pH and conductivity) for each cable in a family are determined based upon calculation using material test results, this is considered as a matter of direct application. Material test results taken from any one sample of finished cable from a family are sufficient to calculate the parameters for each cable in the family. Cables with a diameter of 5,0 mm or less are expected to be tested as bundles according to EN 50399. Cables with a diameter of less than or equal to 5,0 mm are included in the specific and general EXAP rules for single core unsheathed power cables only. The rules apply to circular and non-circular cables provided that they fall within the scope of the relevant test method. A specific EXAP rule has been developed for any of the types of electric cable families as defined in this document. A general EXAP rule has been developed for all electric cable families unless otherwise stated elsewhere in this document. NOTE 1 Multicore power cables are sometimes referred to as control cables with a rated voltage but for the purposes of this document are considered as power cables. For multipair, multitriple and multiquad control cables, either the general EXAP rule or the specific EXAP rule for power cables or the specific EXAP rule for communication cables can be applied. The use of the specific EXAP rule gives benefit in the lower number of cables to be tested for a range of cable constructions (product family). An EXAP is only possible when cables belong to a family as defined in this document. NOTE 2 For the purposes of this document, the term "electric cables" also covers optical fibre cables.
- Standard28 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft27 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the Water Usage Effectiveness (WUE) as a KPI for quantifying the water consumption of a data centre during use phase of the data centre life cycle. This document: a) defines the Water Usage Effectiveness (WUE) of a data centre; b) introduces WUE measurement categories; c) describes the relationship of this KPI to a data centre’s infrastructure, information technology equipment and information technology operations; d) defines the measurement, the calculation and the reporting of the parameter; e) provides information on the correct interpretation of the WUE.
- Standard26 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Jun-2023
- 35.020
- 35.110
- 35.160
- M/462
- CLC/TC 215
IEC 61280-1-4:2023 is available as IEC 61280-1-4:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61280-1-4:2023 establishes the characterization process of the encircled flux measurement method of light sources intended to be used with multimode fibre. This document sets forth a procedure for the collection of two-dimensional fibre optic nearfield greyscale data and subsequent reduction to one-dimensional data expressed as a set of three sampled parametric functions of radius from the fibre’s optical centre. Estimation of the fibre core diameter is not an objective of this document. This third edition cancels and replaces the second edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - improvement of calibration procedure and calibration traceability; - improvement of fibre shaker description and requirements; - addition of pulsed light sources; - removal of a poorly traceable calibration process using a micro positioner.
- Draft29 pagesEnglish languagesale 10% offe-Library read for×1 day
- 22-May-2023
- 33.180.01
- CLC/SR 86C
20211012-JO-Link to 93/42/EEC and M/295 removed
- Amendment4 pagesEnglish languagesale 10% offe-Library read for×1 day
This document provides test methods for the measurement of the following electromagnetic characteristics of lengthwise cable management systems like conduit systems according to EN 61386 series, cable trunking systems and cable ducting systems (CTS/CDS) according to EN 50085 series and cable tray and cable ladder systems according to EN 61537: - shielding effectiveness of magnetic field, - transfer impedance. This document also provides guidance on how these characteristics can be declared and may be used.
- Technical specification27 pagesEnglish languagesale 10% offe-Library read for×1 day
- 20-May-2023
- 29.120.10
- CLC/TC 213
IEC 62146-2:2023 is applicable to TRV capacitors used on high-voltage alternating current circuit-breakers with rated voltages above 100 kV with 50 Hz or 60 Hz. TRV capacitors are installed phase to earth, either in parallel to the bushing on dead tank circuit-breakers, or immersed inside the circuit-breaker, or freestanding close to the circuit-breaker. Their function is to limit the transient recovery voltage (TRV) and the rate of rise of recovery voltage (RRRV) on the circuit-breaker. Capacitors in compliance with this document can be used as TRV capacitor. This document applies to TRV capacitors falling into one or both of the following categories for: - mounting on or close to air insulated switchgear (AIS) dead tank and live tank circuit-breakers, or - mounting on gas insulated switchgear (GIS) circuit-breakers. The testing for each of the above applications is in some cases different. This document does not apply to grading capacitors installed in parallel to the chambers of the circuit-breaker, which are specified in IEC 62146-1. This document does not apply to capacitors not directly associated with high-voltage alternating current circuit-breakers. The object of this document is: - to define uniform rules regarding performances, testing and rating - to define specific safety rules - to provide a guidance for installation and operation The TRV capacitor is a sub-component for the circuit-breaker and is specified in accordance with the circuit-breaker specifications according to IEC 62271-1, IEC 62271-100, and if applicable to IEC 62271-203. TRV capacitors are commonly built with composite or ceramic housings (insulators). Those insulators follow IEC 61462 or IEC 62155. Other housings can be used if they can sustain applicable type tests according to IEC 61462 and IEC 62155. This International Standard is to be used in conjunction with IEC 62146-1:2013 and IEC 62146-1:2013/AMD1:2016.
- Draft18 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 62343:2023 is available as IEC 62343:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62343:2023 applies to all commercially available optical dynamic modules and devices. It describes the products covered by the IEC 62343 series, defines terminology, fundamental considerations and basic approaches. The object of this document is to: - establish uniform requirements for operation, reliability and environmental properties of dynamic modules (DMs) to be implemented in the appropriate DM standard, and - provide assistance to the purchaser in the selection of consistently high-quality DM products for their particular applications, as well as in the consultation of the appropriate specific DM standard(s). This document covers performance templates, performance standards, reliability qualification requirements, hardware and software interfaces and related testing methods. Since a dynamic module integrates an optical module/device, printed wiring board, and software/firmware, the standards developed in the series will mimic appropriate existing standards. On the other hand, since "dynamic module" is a relatively new product category, the dynamic module standards series will not be bound by the existing practices where requirements differ.The safety standards as related to dynamic modules are mostly optical power considerations, which is covered by the IEC 60825 series (see Clause 6). This third edition cancels and replaces the second edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - addition of terms and definitions for optical multicast switches (3.8); - revision of Clause 4, listing the requirements for standards in the IEC 62343 series; - addition of Clause 6 (Safety requirements).
- Draft32 pagesEnglish languagesale 10% offe-Library read for×1 day
- 09-May-2023
- 33.180.01
- 33.180.99
- CLC/SR 86C
IEC 60794-1-305:2023 describes test procedures to be used in establishing uniform requirements for optical fibre ribbons as optical fibre cable elements for the mechanical property-tear (separability). This document applies to optical fibre cables for use with telecommunication equipment and devices employing similar techniques, and to cables having a combination of both optical fibres and electrical conductors. NOTE Throughout the document, the wording "optical cable" can also include optical fibre units, microduct fibre units, etc. This test is applicable for edge-bonded ribbons and encapsulated ribbons specified in IEC 60794-1-31, and not intended to be used for partially-bonded ribbons.
- Draft11 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-May-2023
- 33.180.10
- CLC/TC 86A
1.1 Application This document specifies the main characteristics of the voltage at a network user's supply terminals in public low voltage, medium, high, and extra-high voltage AC electricity networks under normal operating conditions. This document specifies the limits or values within which the voltage characteristics can be expected to remain at any supply terminal in public European electricity networks, only. Industrial networks are excluded from the scope of EN 50160. NOTE 1 If non-public networks (e.g. residential quarters, energy communities, office centres, shopping centres) have similar end-users as public networks, it is strongly advised to apply the same requirements as for public networks. This document does not apply under abnormal operating conditions, including the following: a) a temporary supply arrangement to keep network users supplied during conditions arising as a result of a fault, maintenance and construction work, or to minimize the extent and duration of a loss of supply; b) in the case of non-compliance of a network user's installation or equipment with the relevant standards or with the technical requirements for connection, established either by the public authorities or the network operator, including the limits for the emission of conducted disturbances; NOTE 2 A network user’s installation can include load and generation. c) in exceptional situations, in particular: 1) exceptional weather conditions and other natural disasters; 2) third party interference; 3) acts by public authorities, 4) industrial actions (subject to legal requirements); 5) force majeure; 6) power shortages resulting from external events. The voltage characteristics given in this document refer to conducted disturbances in public electric power networks. They are not intended to be used as electromagnetic compatibility (EMC) levels or product emission limits. Power quality is related to EMC in several ways – especially because compliance with power quality requirements depends on the control of cumulative effect of electromagnetic emissions from all/multiple equipment and/or installations. Therefore, the voltage characteristics given in this document gives guidance for specifying requirements in equipment product standards and in installation standards. NOTE 3 The performance of equipment might be impaired if it is subjected to supply conditions which are not specified in the equipment product standard. NOTE 4 This document can be superseded in total or in part by the terms of a contract between the individual network user and the network operator. The sharing of complaint management and problem mitigation costs between the involved parties is outside the scope of EN 50160. Measurement methods to be applied in this document are described in EN 61000-4-30. [...]
- Standard53 pagesEnglish languagesale 10% offe-Library read for×1 day
This part of IEC 60034 deals with the general guidelines for functional evaluation of electrical insulation systems, used or proposed to be used in rotating electrical machines within the scope of IEC 60034-1, in order to qualify them.
- Draft17 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.