Luminaires - Part 2-2: Particular requirements - Recessed luminaires

This part of IEC 60598 specifies requirements for recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V. It also specifies requirements for recessed air-handling luminaires for use with a ventilation duct or ventilated space (plenum). NOTE The expressions “ventilation” and “ventilated” in this section refer to forced ventilation.

Leuchten - Teil 2-2: Besondere Anforderungen - Einbauleuchten

Luminaires - Partie 2-2: Règles particulières - Luminaires encastrés

Svetilke - 2-2. del: Posebne zahteve - Vgradne svetilke

General Information

Status
Not Published
Current Stage
4020 - Enquiry circulated
Due Date
29-Oct-2021
Completion Date
29-Oct-2021

RELATIONS

Buy Standard

Draft
prEN IEC 60598-2-2:2022
English language
16 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (sample)

SLOVENSKI STANDARD
oSIST prEN IEC 60598-2-2:2022
01-januar-2022
Svetilke - 2-2. del: Posebne zahteve - Vgradne svetilke
Luminaires - Part 2-2: Particular requirements - Recessed luminaires
Leuchten - Teil 2-2: Besondere Anforderungen - Einbauleuchten
Luminaires - Partie 2-2: Règles particulières - Luminaires encastrés
Ta slovenski standard je istoveten z: prEN IEC 60598-2-2:2021
ICS:
29.140.40 Svetila Luminaires
oSIST prEN IEC 60598-2-2:2022 en

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN IEC 60598-2-2:2022
---------------------- Page: 2 ----------------------
oSIST prEN IEC 60598-2-2:2022
34D/1633/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 60598-2-2 ED4
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2021-10-29 2022-01-21
SUPERSEDES DOCUMENTS:
34D/1600/CD, 34D/1616A/CC
IEC SC 34D : LUMINAIRES
SECRETARIAT: SECRETARY:
United Kingdom Ms Shanti Conn
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:
Other TC/SCs are requested to indicate their interest, if
any, in this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY

SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING

Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.

This document is still under study and subject to change. It should not be used for reference purposes.

Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of

which they are aware and to provide supporting documentation.
TITLE:
Luminaires - Part 2-2: Particular requirements - Recessed luminaires
PROPOSED STABILITY DATE: 2025
NOTE FROM TC/SC OFFICERS:

Subject: Revision of recessed luminaire standard and merging of air-handling luminaire requirements

Project Leader: David Crossley

Note: The CDV is based on 34D/1600/CD updated in line with the responses to the national committee

comments given in 34D/1616/CC.

Copyright © 2021 International Electrotechnical Commission, IEC. All rights reserved. It is permitted to

download this electronic file, to make a copy and to print out the content for the sole purpose of preparing

National Committee positions. You may not copy or "mirror" the file or printed version of the document, or any

part of it, for any other purpose without permission in writing from IEC.
---------------------- Page: 3 ----------------------
oSIST prEN IEC 60598-2-2:2022
60598-2-2/Ed.4/CDV © IEC(E) 2 34D/1633/CDV
INTRODUCTION (not part of the proposal)
As agreed during:

• the 34D WG1 meeting in Wellington (see 34D/WG1(SEC)022, sections 4.16 and 6.2);

• 34D WG1 meeting (19-20 October and 4 & 14 December (see 34D_WG1(SEC)032A
Minutes Section 4.1); and
• 34D WG1 meeting 16-17 June 2021 (see 34D_WG1(SEC)043A Minutes Section 6.2.1)

LUMEX agreed for recessed luminaire requirements to be moved from IEC 60598-1 to IEC

60598.2.2 and to merge the content of IEC 60598-2-19 Air-handling luminaires into IEC

60598-2-2.
LUMEX agreed for this proposal to be circulated as a CDV.

Commentators are asked to note the intent of this revision is not to change any requirements

but simply move all specific recessed luminaire requirements from Part 1 into Part 2-2 and

merge the requirements for air handling luminaires (i.e. Part 2-19) with Part 2-2.

---------------------- Page: 4 ----------------------
oSIST prEN IEC 60598-2-2:2022
60598-2-2/Ed.4/CDV © IEC(E) 3 34D/1633/CDV
1 PROPOSAL
2 CONTENTS

4 2.1 Scope ..................................................................................................................... 6

5 2.2 Normative references .............................................................................................. 6

6 2.3 Terms and definitions .............................................................................................. 6

7 2.4 General test requirements ....................................................................................... 7

8 2.5 Classification of luminaires ...................................................................................... 7

9 2.6 Marking ................................................................................................................... 7

10 2.7 Construction ............................................................................................................ 7

11 2.8 Creepage distances and clearances......................................................................... 8

12 2.9 Provision for earthing .............................................................................................. 8

13 2.10 Terminals ................................................................................................................ 8

14 2.11 External and internal wiring ..................................................................................... 8

15 2.12 Protection against electric shock .............................................................................. 8

16 2.13 Endurance tests and thermal tests ........................................................................... 8

17 2.14 Resistance to dust and moisture .............................................................................. 9

18 2.15 Insulation resistance and electric strength .............................................................. 10

19 2.16 Resistance to heat, fire and tracking ...................................................................... 10

20 Annex A (informative) Measurement of ambient temperature in an installation ..................... 11

21 Annex B (normative) Recessed luminaire thermal test methods ......................................... 12

22 Annex C (informative) Explanation of t in respect of air-handling luminaires ..................... 15

23 Annex D (informative) Schedule of amended subclauses containing more

24 serious/critical requirements which require products to be retested ......................... 16

27 Figure 1 – Symbol for luminaires not suitable for direct mounting on normally

28 flammable surfaces (suitable only for mounting on non-combustible surfaces) ........................ 7

29 Figure 2 – Symbol for luminaires not suitable for covering with thermally insulating

30 material ................................................................................................................................ 7

31 Figure B.1 – Example of test recess according to a) where a luminaire comprises

32 separate part ...................................................................................................................... 12

33 Figure B.2 – Example of test recess according to b) where a luminaire comprises

34 separate parts .................................................................................................................... 13

35 Figure B.3 – Correct test box size (insulating ceilings) for settable and adjustable

36 luminaires ........................................................................................................................... 14

38 Table 1 – Operating temperature of cable .............................................................................. 9

---------------------- Page: 5 ----------------------
oSIST prEN IEC 60598-2-2:2022
60598-2-2/Ed.4/CDV © IEC(E) 4 34D/1633/CDV
41 INTERNATIONAL ELECTROTECHNICAL COMMISSION
42 ____________
44 LUMINAIRES –
46 Part 2-2: Particular requirements –
47 Recessed luminaires and recessed air-handling luminaires
50 FOREWORD

51 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising

52 all national electrotechnical committees (IEC National Committees). The object of IEC is to promote

53 international co-operation on all questions concerning standardization in the electrical and electronic fields. To

54 this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,

55 Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC

56 Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested

57 in the subject dealt with may participate in this preparatory work. International, governmental and non-

58 governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely

59 with the International Organization for Standardization (ISO) in accordance with conditions determined by

60 agreement between the two organizations.

61 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international

62 consensus of opinion on the relevant subjects since each technical committee has representation from all

63 interested IEC National Committees.

64 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National

65 Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC

66 Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any

67 misinterpretation by any end user.

68 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications

69 transparently to the maximum extent possible in their national and regional publications. Any divergence

70 between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in

71 the latter.

72 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity

73 assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any

74 services carried out by independent certification bodies.

75 6) All users should ensure that they have the latest edition of this publication.

76 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and

77 members of its technical committees and IEC National Committees for any personal injury, property damage or

78 other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and

79 expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC

80 Publications.

81 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is

82 indispensable for the correct application of this publication.

83 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of

84 patent rights. IEC shall not be held responsible for identifying any or all such patent rights.

85 IEC 60598-2-2 has been prepared by subcommittee 34D: Luminaires, of IEC technical

86 committee 34:Lighting. Is is an International Standard.

87 This fourth edition cancels and replaces the third edition published in 2011. This edition

88 constitutes a technical revision.

89 This edition includes the following technical changes with respect to the previous edition

90 (there are no major technical changes, see Annex D):

91 a) The requirements specific to recessed luminaries given in IEC 60598-1 are now

92 incorporated in this Part 2-2.

93 b) The requirements for air-handling luminaires given in IEC 60598-2-19 are now

94 incorporated in this Part 2-2.
95 c) The references to Part 1 have been updated
---------------------- Page: 6 ----------------------
oSIST prEN IEC 60598-2-2:2022
60598-2-2/Ed.4/CDV © IEC(E) 5 34D/1633/CDV
96 The text of this International Standard is based on the following documents:
Draft Report on voting
34D/XX/FDIS 34D/XX/RVD

98 Full information on the voting for its approval can be found in the report on voting indicated in

99 the above table.

100 The language used for the development of this International Standard is English.

101 This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in

102 accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement,

103 available at www.iec.ch/members_experts/refdocs. The main document types developed by

104 IEC are described in greater detail at www.iec.ch/standardsdev/publications.

105 A list of all parts in the IEC 60598 series, published under the general title Luminaires can be

106 found on the IEC website.

107 This Part 2-2 is to be used in conjunction with the latest edition of IEC 60598-1 and its

108 amendment(s). It was established on the basis of the ninth edition (2020).

109 NOTE 1 When “Part 1” is mentioned in this document, it refers to IEC 60598-1.

110 NOTE 2 In this document, the following print type is used:
111 – compliance statements: in italic type.

112 The committee has decided that the contents of this document will remain unchanged until the

113 stability date indicated on the IEC website under webstore.iec.ch in the data related to the

114 specific document. At this date, the document will be
115 • reconfirmed,
116 • withdrawn,
117 • replaced by a revised edition, or
118 • amended.
119
120
---------------------- Page: 7 ----------------------
oSIST prEN IEC 60598-2-2:2022
60598-2-2/Ed.4/CDV © IEC(E) 6 34D/1633/CDV
121 LUMINAIRES –
122
123 Part 2-2: Particular requirements –
124 Recessed luminaires and recessed air-handling luminaires
125
126
127
128 2.1 Scope

129 This part of IEC 60598 specifies requirements for recessed luminaires incorporating electric

130 light sources for operation from supply voltages up to 1 000 V. It also specifies requirements

131 for recessed air-handling luminaires for use with a ventilation duct or ventilated space (plenum).

132 NOTE The expressions “ventilation” and “ventilated” in this section refer to forced ventilation.

133 2.2 Normative references

134 The following referenced documents are indispensable for the application of this document.

135 For dated references, only the edition cited applies. For undated references, the latest edition

136 of the referenced document (including any amendments) applies.

137 IEC 60227 (all parts), Polyvinyl chloride insulated cables of rated voltages up to and including

138 450/750 V

139 IEC 60245 (all parts), Rubber insulated cables – Rated voltages up to and including

140 450/750 V
141 IEC 60598-1, Luminaires – Part 1: General requirements and tests
142 2.3 Terms and definitions

143 For the purposes of this document, the terms and definitions given in Part 1 and the following

144 apply.

145 ISO and IEC maintain terminological databases for use in standardization at the following

146 addresses:
147 • IEC Electropedia: available at http://www.electropedia.org/
148 • ISO Online browsing platform: available at http://www.iso.org/obp
149 2.3.1
150 air-handling luminaire

151 luminaire specially designed for use in association with an air conditioning system.

152 Note 1 to entry: The air may pass either through the lamp chamber or through separate passages.

153 Note 2 to entry: For an explanation of the significance of t as applied to air-handling luminaires (see Annex C).

154 2.3.2
155 static operation

156 operation of a luminaire when not handling either forced supply or extract air but permitting

157 convection.
---------------------- Page: 8 ----------------------
oSIST prEN IEC 60598-2-2:2022
60598-2-2/Ed.4/CDV © IEC(E) 7 34D/1633/CDV
158 2.4 General test requirements

159 The provisions of section 0 of Part 1 apply. The tests described in each appropriate section of

160 Part 1 shall be carried out in the order listed in this section of Part 2.

161 A procedure measuring ambient temperature in an installation is given in Annex A.

162 NOTE Annex A provides additional information on how ambient temperature is considered within the recessed

163 cavity area relative to the t marking of the luminaire.
164 2.5 Classification of luminaires

165 Luminaires shall be classified in accordance with the provisions of Section 2 of Part 1.

166 2.6 Marking
167 The provisions of Section 3 of Part 1 apply, as well as the following.

168 The following information shall be distinctly and durably marked on the luminaire and be

169 visible during installation or behind a cover or part which is removed during installation.

170 2.6.1 For recessed luminaires with two IP ratings, both ratings shall be visible during

171 installation and it shall be obvious to which parts of the luminaire the ratings refer. The

172 relevant information shall be provided even if the rating is IP20 or the lower rating is specified

173 as ordinary.

174 2.6.2 Where applicable, the relevant symbol for recessed luminaires not suitable for direct

175 mounting on normally flammable surfaces. The symbol shall be explained on the luminaire or

176 in the manufacturer’s instructions provided with the luminaire. The minimum size of the

177 symbol shall be 25mm for each side.
178

179 Figure 1 – Symbol for luminaires not suitable for direct mounting on normally

180 flammable surfaces (suitable only for mounting on non-combustible surfaces)

181 2.6.3 The relevant symbol for luminaires not suitable for covering with thermally insulated

182 material. The symbol shall be explained on the luminaire or in the manufacturer’s instructions

183 provided with the luminaire. The minimum size of the symb
...