Alarm systems - Intrusion and hold-up systems - Part 2-8: Intrusion detectors - Shock detectors

This European Standard is for Shock Detectors installed in buildings to detect the shock or series of shocks due to a forcible attack through a physical barrier (for example doors or windows). It specifies four security Grades 1-4 (in accordance with EN 50131-1), specific or non-specific wired or wire-free detectors and uses environmental Classes I-IV (in accordance with EN 50130-5). This European Standard does not include requirements for detectors intended to detect penetration attacks on safes and vaults for example by drilling, cutting or thermal lance. This European Standard does not include requirements for shock detectors intended for use outdoors. A detector needs to fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this European Standard may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions. This European Standard does not deal with requirements for compliance with regulatory directives, such as EMC-directive, low-voltage directive, etc., except that it specifies the equipment operating conditions for EMC- susceptibility testing as required by EN 50130-4. This European Standard does not apply to system interconnections.

Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 2-8: Anforderungen an Erschütterungsmelder

Systèmes d'alarme - Systèmes d'alarme contre l’intrusion et les hold-up - Partie 2-8: Détecteurs d’intrusion - Détecteurs de chocs

La présente norme concerne les détecteurs de chocs installés dans les bâtiments afin de détecter le choc ou la succession de chocs résultant d’une attaque violente contre une barrière matérielle (par exemple, les portes ou les fenêtres). Elle spécifie quatre grades de sécurité allant de 1 à 4 (conformément à l’EN 50131-1), des détecteurs filaires ou sans fil spécifiques ou non spécifiques, et elle utilise des classes d’environnement I-IV (conformément à l’EN 50130 5). La présente Norme européenne ne contient pas les exigences pour les détecteurs destinés à détecter les attaques pour accéder aux coffres-forts et aux chambres fortes, par exemple par perçage, découpe ou en utilisant une lance thermique. La présente Norme européenne ne comprend pas les exigences pour les détecteurs de chocs destinés à être utilisés à l’extérieur. Un détecteur doit satisfaire à toutes les exigences du grade spécifié. Des fonctions complémentaires aux fonctions obligatoires spécifiées dans la présente Norme européenne peuvent être incluses dans le détecteur, sous réserve qu’elles n’altèrent pas la bonne marche des fonctions obligatoires. La présente Norme européenne ne traite pas des exigences de conformité avec les directives réglementaires, telles que la directive CEM, la Directive Basse Tension, etc., mais elle spécifie les conditions de fonctionnement du matériel pour les essais de susceptibilité CEM, comme cela est exigé par l’EN 50130-4. La présente Norme européenne ne s’applique pas aux liaisons entre systèmes.

Alarmni sistemi - Sistemi za javljanje vloma in ropa - 2-8. del: Javljalniki vloma - Javljalniki udara

Ta evropski standard se uporablja za javljalnike udara, nameščene v stavbah, za javljanje udara ali niza udarov zaradi nasilnega napada skozi fizično oviro (na primer vrata ali okna).
Določa varnostne razrede 1–4 (glej standard EN 50131-1), specifične ali nespecifične ožičene ali brezžične detektorje in uporablja okoljske razrede I–IV (glej standard EN 50130-5).
Ta evropski standard ne zajema zahtev za detektorje, namenjene za zaščito trezorjev in sefov pred vdori, na primer z vrtanjem, rezanjem ali toplotnim obsevanjem.
Ta evropski standard ne zajema zahtev za javljalnike udara, namenjene za zunanjo uporabo.
Detektor mora izpolnjevati vse zahteve določenega razreda.
Poleg obveznih funkcij, ki so opredeljene v tej tehnični specifikaciji, ima lahko detektor tudi dodatne funkcije, pri čemer te ne smejo neugodno vplivati na pravilno delovanje obveznih funkcij.
Ta evropski standard se ne uporablja za medsebojne povezave sistemov.

General Information

Status
Published
Publication Date
15-Dec-2016
Technical Committee
Drafting Committee
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
20-Apr-2022

Relations

Buy Standard

Standard
EN 50131-2-8:2017
English language
41 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-februar-2017
1DGRPHãþD
SIST-TS CLC/TS 50131-2-8:2012
Alarmni sistemi - Sistemi za javljanje vloma in ropa - 2-8. del: Javljalniki vloma -
Javljalniki udara
Alarm systems - Intrusion and hold-up systems - Part 2-8: Intrusion detectors - Shock
detectors
Alarmanlagen - Einbruchmeldeanlagen - Teil 2-8: Anforderungen an
Erschütterungsmelder
Systèmes d'alarme - Systèmes d'alarme contre l’intrusion et les hold-up - Partie 2-8:
Détecteurs d’intrusion - Détecteurs de chocs
Ta slovenski standard je istoveten z: EN 50131-2-8:2016
ICS:
13.310 Varstvo pred kriminalom Protection against crime
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 50131-2-8

NORME EUROPÉENNE
EUROPÄISCHE NORM
December 2016
ICS 13.320 Supersedes CLC/TS 50131-2-8:2012
English Version
Alarm systems - Intrusion and hold-up systems - Part 2-8:
Intrusion detectors - Shock detectors
Systèmes d'alarme - Systèmes d'alarme contre l'intrusion et Alarmanlagen - Einbruchmeldeanlagen - Teil 2-8:
les hold-up - Partie 2-8: Détecteurs d'intrusion - Détecteurs Anforderungen an Erschütterungsmelder
de chocs
This European Standard was approved by CENELEC on 2016-10-03. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 50131-2-8:2016 E
Contents Page
European foreword . 6
Introduction . 7
1 Scope . 8
2 Normative references . 8
3 Terms, definitions and abbreviations . 8
3.1 Terms and definitions . 8
3.2 Abbreviations . 9
4 Functional requirements . 9
4.1 General . 9
4.2 Event Processing . 10
4.3 Detection . 11
4.3.1 Detection performance . 11
4.3.2 Indication of detection . 12
4.4 Immunity to false alarm sources . 12
4.4.1 General . 12
4.4.2 Immunity to Small objects hitting a framed window . 12
4.4.3 Immunity to Hard objects hitting a framed window . 13
4.4.4 Immunity to Static pressure . 13
4.4.5 Immunity to Dynamic pressure . 13
4.4.6 Standard Immunity Test . 13
4.5 Operational requirements . 13
4.5.1 Time interval between intrusion signals or messages . 13
4.5.2 Switch on delay . 13
4.5.3 Self-tests . 13
4.6 Tamper security . 14
4.6.1 General . 14
Resistance to and detection of unauthorised access to components and means of
4.6.2
adjustment . 14
4.6.3 Detection of removal from the mounting surface . 14
4.6.4 Resistance to magnetic field interference . 15
4.6.5 Detection of masking . 15
4.7 Electrical requirements . 15
4.7.1 General . 15
4.7.2 Shock detectors current consumption . 16
4.7.3 Slow input voltage change and voltage range limits . 16
4.7.4 Input voltage ripple . 16
4.7.5 Input voltage step change . 16
4.8 Environmental classification and conditions . 16
4.8.1 Environmental classification . 16
4.8.2 Immunity to environmental conditions . 16
5 Marking, identification and documentation . 16
5.1 Marking and/or identification . 16
5.2 Documentation . 16
6 Testing . 17
6.1 General . 17
6.2 General test conditions . 17
6.2.1 Standard conditions for testing . 17
6.2.2 General detection testing environment and procedures . 17
6.3 Basic Detection Test . 18
6.3.1 General . 18
6.3.2 Basic Detection Test Method . 18
6.4 Performance tests . 18
6.4.1 General . 18
6.4.2 Verification of detection performance . 18
6.5 Switch-on delay, time interval between signals and indication of detection . 20
Self-tests . 20
6.6
6.7 Immunity to incorrect operation . 20
6.7.1 General . 20
6.7.2 Immunity to Small objects hitting the glass . 21
6.7.3 Immunity to Hard objects hitting a framed window . 21
6.7.4 Immunity to Static pressure . 22
6.7.5 Immunity to Dynamic pressure . 22
6.7.6 Standard Immunity Test . 23
6.8 Tamper security . 23
6.8.1 General . 23
6.8.2 Resistance to and detection of unauthorised access to the inside of the shock detector

through covers and existing holes . 23
6.8.3 Detection of removal from the mounting surface . 23
6.8.4 Resistance to magnetic field interference . 23
6.8.5 Detection of shock detector masking . 24
6.9 Electrical tests . 24
6.9.1 General . 24
6.9.2 Shock detector current consumption . 24
6.9.3 Slow input voltage change and input voltage range limits . 25
6.9.4 Input voltage ripple . 25
6.9.5 Input voltage step change . 25
6.9.6 Total loss of power supply . 26
6.10 Environmental classification and conditions . 26
6.11 Marking, identification and documentation . 27
6.11.1 Marking and/or identification .
...

Questions, Comments and Discussion