Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power

This part of CISPR 16 is designated a basic standard, which specifies the characteristics and calibration of the absorbing clamp for the measurement of radio disturbance power in the frequency range 30 MHz to 1 GHz. This second edition cancels and replaces the first edition published in 2003. It constitutes a technical revision. In this edition a more detailed calibration method for the absorbing clamp is specified. Furthermore, new alternative calibration methods are introduced which are more practicable than the one which was specified previously. Additional parameters to describe the absorbing clamp are defined, like the decoupling factor for the broadband absorber (DF) and the decoupling factor for the current transformer (DR), along with their validation methods. A procedure for the validation of the absorbing clamp test site (ACTS) is also included in the document.

Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 1-3: Geräte und Einrichtungen zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Zusatz-/Hilfseinrichtungen - Störleistungsmessung

Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Partie 1-3: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Matériels auxiliaires - Puissance perturbatrice

La présente partie de la CISPR 16 est une norme fondamentale qui spécifie les caractéristiques et l'étalonnage de la pince absorbante pour la mesure de la puissance perturbatrice radioélectrique dans la gamme de fréquences de 30 MHz à 1 GHz. Cette deuxième édition annule et remplace la première édition parue en 2003. Elle constitue une révision technique. Cette édition spécifie une méthode d'étalonnage plus détaillée pour la pince absorbante. De plus, de nouvelles méthodes d'étalonnage possibles sont introduites, qui sont plus praticables que celle qui était spécifiée auparavant. Des paramètres additionnels pour décrire la pince absorbante sont définis, tels le facteur de découplage pour l'absorbeur large bande DF et le facteur de découplage pour le transformateur de courant DR

Specifikacija za merilne naprave in metode za merjenje radijskih motenj in odpornosti - 1-3. del: Merilne naprave za merjenje radijskih motenj in odpornosti - Pomožna oprema - Moč motenj - Dopolnilo A1

General Information

Status
Published
Publication Date
05-May-2016
Withdrawal Date
04-May-2019
Current Stage
6060 - Document made available - Publishing
Start Date
06-May-2016
Completion Date
06-May-2016

Relations

Buy Standard

Amendment
EN 55016-1-3:2007/A1:2016
English language
10 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 55016-1-3:2007/A1:2016
01-julij-2016
6SHFLILNDFLMD]DPHULOQHQDSUDYHLQPHWRGH]DPHUMHQMHUDGLMVNLKPRWHQMLQ
RGSRUQRVWLGHO0HULOQHQDSUDYH]DPHUMHQMHUDGLMVNLKPRWHQMLQRGSRUQRVWL
3RPRåQDRSUHPD0RþPRWHQM'RSROQLOR$
Specification for radio disturbance and immunity measuring apparatus and methods -
Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment -
Disturbance power
Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur
Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil
1-3: Geräte und Einrichtungen zur Messung der hochfrequenten Störaussendung
(Funkstörungen) und Störfestigkeit - Zusatz-/Hilfseinrichtungen - Störleistungsmessung
Spécifications des méthodes et des appareils de mesure des perturbations
radioélectriques et de l'immunité aux perturbations radioélectriques - Partie 1-3:
Appareils de mesure des perturbations radioélectriques et de l'immunité aux
perturbations radioélectriques - Matériels auxiliaires - Puissance perturbatrice
Ta slovenski standard je istoveten z: EN 55016-1-3:2006/A1:2016
ICS:
17.220.20 0HUMHQMHHOHNWULþQLKLQ Measurement of electrical
PDJQHWQLKYHOLþLQ and magnetic quantities
33.100.20 Imunost Immunity
SIST EN 55016-1-3:2007/A1:2016 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 55016-1-3:2007/A1:2016

---------------------- Page: 2 ----------------------

SIST EN 55016-1-3:2007/A1:2016


EUROPEAN STANDARD EN 55016-1-3:2006/A1

NORME EUROPÉENNE

EUROPÄISCHE NORM
May 2016
ICS 33.100.10; 33.100.20

English Version
Specification for radio disturbance and immunity measuring
apparatus and methods -
Part 1-3: Radio disturbance and immunity measuring apparatus -
Ancillary equipment - Disturbance power
(CISPR 16-1-3:2004/A1:2016)
Spécifications des méthodes et des appareils de mesure Anforderungen an Geräte und Einrichtungen sowie
des perturbations radioélectriques et de l'immunité aux Festlegung der Verfahren zur Messung der hochfrequenten
perturbations radioélectriques - Störaussendung (Funkstörungen) und Störfestigkeit -
Partie 1-3: Appareils de mesure des perturbations Teil 1-3: Geräte und Einrichtungen zur Messung der
radioélectriques et de l'immunité aux perturbations hochfrequenten Störaussendung (Funkstörungen) und
radioélectriques - Matériels auxiliaires - Puissance Störfestigkeit - Zusatz-/Hilfseinrichtungen -
perturbatrice Störleistungsmessung
(CISPR 16-1-3:2004/A1:2016) (CISPR 16-1-3:2004/A1:2016)
This amendment A1 modifies the European Standard EN 55016-1-3:2006; it was approved by CENELEC on 2016-05-05. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 55016-1-3:2006/A1:2016 E

---------------------- Page: 3 ----------------------

SIST EN 55016-1-3:2007/A1:2016
EN 55016-1-3:2006/A1:2016
European foreword
The text of document CIS/A/1111/CDV, future CISPR 16-1-3:2004/A1, prepared by SC A “Radio
interference measurements and statistical methods" of IEC/TC CISPR “International special
committee on radio interference” was submitted to the IEC-CENELEC parallel vote and approved by
CENELEC as EN 55016-1-3:2006/A1:2016.

The following dates are fixed:
• latest date by which the document has to be (dop) 2017-02-05
implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2019-05-05
• latest date by which the national
standa
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.