Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-30: Examinations and measurements - Endface geometry of rectangular ferrule

IEC 61300-3-30:2020 is available as IEC 61300-3-30:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61300-3-30:2020 describes a method of measuring the end face geometry of rectangular multifibre ferrules having an IEC defined optical interface. The primary attributes are fibre position relative to the end face, either withdrawal or protrusion, end face angle relative to the guide pin bores, fibre tip radii and core dip for multimode fibres. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision.This edition includes the following significant technical changes with respect to the previous edition: - measurement of the individual fibre tip radii; - introduction of the geometry limit (GL) metric; - introduction of the minus coplanarity metric; - new method for measuring the core dips; - all measurement regions are now identical for MM and SM fibres; - the ferrule surface angle sign convention has been changed.

Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prüf- und Messverfahren - Teil 3-30: Untersuchungen und Messungen - Endflächen-Geometrie einer rechteckigen Ferrule

Dispositifs d’interconnexion et composants passifs fibroniques - Procédures fondamentales d’essais et de mesures - Partie 3-30: Examens et mesures - Géométrie de la face terminale de la ferrule rectangulaire

IEC 61300-3-30:2020 est disponible sous forme de IEC 61300-3-30:2020 RLV qui contient la Norme internationale et sa version Redline, illustrant les modifications du contenu technique depuis l'�dition pr�c�dente.IEC 61300-3-30:2020 décrit une méthode de mesure de la géométrie de la face terminale des ferrules rectangulaires multifibres ayant une interface optique définie par l’IEC. Les attributs primaires sont la position relative de la fibre par rapport à la face terminale, soit en enfoncement, soit en excroissance, et l’angle relatif de la face terminale par rapport aux forages de la broche de guidage, les rayons des pointes des fibres et l’inclinaison du cœur pour des fibres multimodales. Cette deuxième édition annule et remplace la première édition parue en 2003. Cette édition constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l’édition précédente: mesurage des rayons des pointes individuelles des fibres; - introduction de la métrique de limite de géométrie (GL); - introduction de la métrique de coplanarité négative; - nouvelle méthode de mesure de l’inclinaison du cœur; - toutes les régions de mesurage sont désormais identiques pour les fibres MM et SM; - la convention du signe de l’angle de surface de la ferrule a été modifiée.

Optični spojni elementi in pasivne komponente - Postopki osnovnega preskušanja in meritev- 3-30. del: Preiskave in meritve - Geometrija čela za pravokotne tulce (IEC 61300-3-30:2020)

General Information

Status
Published
Publication Date
04-Feb-2021
Current Stage
6060 - Document made available - Publishing
Start Date
05-Feb-2021
Completion Date
05-Feb-2021

Relations

Buy Standard

Standard
EN IEC 61300-3-30:2021
English language
22 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-april-2021
Nadomešča:
SIST EN 61300-3-30:2004
Optični spojni elementi in pasivne komponente - Postopki osnovnega preskušanja
in meritev- 3-30. del: Preiskave in meritve - Geometrija čela za pravokotne tulce
(IEC 61300-3-30:2020)
Fibre optic interconnecting devices and passive components - Basic test and
measurement procedures - Part 3-30: Examinations and measurements - Endface
geometry of rectangular ferrule (IEC 61300-3-30:2020)
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prüf- und
Messverfahren - Teil 3-30: Untersuchungen und Messungen - Endflächen-Geometrie
einer rechteckigen Ferrule (IEC 61300-3-30:2020)
Dispositifs d’interconnexion et composants passifs fibroniques - Procédures
fondamentales d’essais et de mesures - Partie 3-30: Examens et mesures - Géométrie
de la face terminale de la ferrule rectangulaire (IEC 61300-3-30:2020)
Ta slovenski standard je istoveten z: EN IEC 61300-3-30:2021
ICS:
33.180.20 Povezovalne naprave za Fibre optic interconnecting
optična vlakna devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN IEC 61300-3-30

NORME EUROPÉENNE
EUROPÄISCHE NORM
February 2021
ICS 33.180.20 Supersedes EN 61300-3-30:2003 and all of its
amendments and corrigenda (if any)
English Version
Fibre optic interconnecting devices and passive components -
Basic test and measurement procedures - Part 3-30:
Examinations and measurements - Endface geometry of
rectangular ferrule
(IEC 61300-3-30:2020)
Dispositifs d'interconnexion et composants passifs Lichtwellenleiter - Verbindungselemente und passive
fibroniques - Procédures fondamentales d'essais et de Bauteile - Grundlegende Prüf- und Messverfahren - Teil 3-
mesures - Partie 3-30: Examens et mesures - Géométrie de 30: Untersuchungen und Messungen - Endflächen-
la face terminale de la ferrule rectangulaire Geometrie einer rechteckigen Ferrule
(IEC 61300-3-30:2020) (IEC 61300-3-30:2020)
This European Standard was approved by CENELEC on 2021-01-18. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 61300-3-30:2021 E

European foreword
The text of document 86B/4357/FDIS, future edition 2 of IEC 61300-3-30, prepared by SC 86B "Fibre
optic interconnecting devices and passive components" of IEC/TC 86 "Fibre optics" was submitted to
the IEC-CENELEC parallel vote and approved by CENELEC as EN IEC 61300-3-30:2021.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2021-10-18
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2024-01-18
document have to be withdrawn
This document supersedes EN 61300-3-30:2003 and all of its amendments and corrigenda (if any).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Endorsement notice
The text of the International Standard IEC 61300-3-30:2020 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards
indicated:
IEC 61300 (series) NOTE Harmonized as EN 61300 (series)
IEC 61755-3-31:2015 NOTE Harmonized as EN 61755-3-31:2015 (not modified)
IEC 61755-3-32:2015 NOTE Harmonized as EN 61755-3-32:2016 (not modified)

IEC 61300-3-30 ®
Edition 2.0 2020-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Fibre optic interconnecting devices and passive components – Basic test and

measurement procedures –
Part 3-30: Examinations and measurements – Endface geometry of rectangular

ferrule
Dispositifs d’interconnexion et composants passifs fibroniques – Procédures

fondamentales d’essais et de mesures –

Partie 3-30: Examens et mesures – Géométrie de la face terminale de la ferrule

rectangulaire
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.180.20 ISBN 978-2-8322-9121-4

– 2 – IEC 61300-3-30:2020 © IEC 2020
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 General description . 6
5 Measurement regions . 7
6 Apparatus . 8
6.1 General . 8
6.2 Ferrule holder . 8
6.3 Positioning stage . 9
6.4 Three-dimensional interferometry analyser . 9
7 Procedure . 9
8 Details to be specified . 11
Annex A (normative) Formulae for approximating the end face geometry . 12
A.1 Approximation of the ferrule surface. 12
A.2 Approximation of the fibre tip radii. 12
Annex B (normative) Surface angle sign convention (shown graphically) . 13
Annex C (normative) Fibre counting convention (shown graphically) . 14
Annex D (normative) Minus coplanarity and fibre plane angle determination . 15
D.1 Overview. 15
D.1.1 General . 15
D.1.2 Minus coplanarity. 15
D.1.3 Fibre plane x-axis and y-axis angles . 15
D.2 Method for analysis . 15
D.2.1 Single row ferrules . 15
D.2.2 Multi-row ferrules . 15
D.3 Documentation . 16
Annex E (normative) Calculation of core dip using the paraboloid method. 17
E.1 General . 17
E.2 Method for analysis . 17
Annex F (normative) Calculation of GL parameter . 18
F.1 General . 18
F.2 Method for analysis . 18
Bibliography . 20

Figure 1 – Measurement regions on ferrule and fibre . 7
Figure 2 – Measurement setup . 8
Figure B.1 – Surface angle sign convention . 13
Figure C.1 – Fibre counting convention . 14
Figure E.1 – Paraboloid fit to a fibre endface exhibiting core dip . 17

Table 1 – Ferrule measurement areas and parameters . 8
Table F.1 – Parameter constants for 4-fibre ferrules . 19

IEC 61300-3-30:2020 © IEC 2020 – 3 –
Table F.2 – Parameter constants for 8-fibre ferrules . 19
Table F.3 – Parameter constants for 12-fibre ferrules . 19

– 4 – IEC 61300-3-30:2020 © IEC 2020
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FIBRE OPTIC INTERCONNECTING DEVICES
AND PASSIVE COMPONENTS –
BASIC TEST AND MEASUREMENT PROCEDURES –

Part 3-30: Examinations and measurements –
Endface geometry of rectangular ferrule

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC Publication(s)"). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.