EN 175301-803:1999
(Main)Detail Specification: Rectangular connectors - Flat contacts, 0,8 mm thickness, locking screw not detachable
- BACK
- 22-Nov-1999
- 22-May-2000
- 31.220.10
- CLC/SR 48B
Detail Specification: Rectangular connectors - Flat contacts, 0,8 mm thickness, locking screw not detachable
Former CECC 75 301-803 * D117/123: BTWG 117-1 set up to revise EN * Superseded by EN 175301-803:2006
Spécification particulière: Connecteurs rectangulaires - Contacts plats, épaisseur de 0,8 mm, vis d'arrêt non détachable
Detail specification: Rectangular connectors - Flat contacts, 0,8 mm thickness, locking screw not detachable
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Detail specification: Rectangular connectors - Flat contacts, 0,8 mm thickness, locking screw not detachableSpécification particulière: Connecteurs rectangulaires - Contacts plats, épaisseur de 0,8 mm, vis d'arrêt non détachableDetail Specification: Rectangular connectors - Flat contacts, 0,8 mm thickness, locking screw not detachable31.220.10Plug-and-socket devices. ConnectorsICS:Ta slovenski standard je istoveten z:EN 175301-803:1999SIST EN 175301-803:2002en01-september-2002SIST EN 175301-803:2002SLOVENSKI
STANDARD
SIST EN 175301-803
...
This May Also Interest You
IEC 61076-2-101:2024 describes M12 screw-locking circular connectors with 2-way up to 17‑way, for data transmission with frequencies up to 100 MHz and signal and power transmission at up to 250 V rated voltage and up to 4 A rated current per contact. These connectors consist of fixed and free connectors, either rewirable or non-rewirable. Male connectors have round contacts, Ø 0,6 mm, Ø 0,76 mm, Ø 0,8 mm or Ø 1,0 mm according to number of ways and coding, all contacts with the same size. The different codings prevent the mating of differently coded male and female connectors. This fourth edition cancels and replaces the third edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Technical specifications regarding dimensional information (Clause 5) and characteristics (Clause 6) have been updated, and new subclauses have been added. b) New style NF (free connectors) has been added. c) Fixed connectors with glass to metal seals (former styles WM, XM, YM, ZM and WF, XF, TF and ZF) are no longer covered by this document: relevant definitions and requirements have been removed. d) The P-coding has been eliminated. e) Annex B (informative) Steel conduit thread, sizes has been deleted and a new Annex B (informative) Orientation of cable outlet in relation to coding has been added. f) The dimension specification of former styles AM and BM have been moved into a new Annex C (normative).
- Standard77 pagesEnglish languagesale 10% offe-Library read for×1 day
- 09-Jan-2025
- 31.220.10
- CLC/SR 48B
IEC 60352-2:2024 is applicable to solderless crimped connections made with: - appropriately designed uninsulated or pre-insulated crimp barrels as parts of crimp contacts, terminal ends or splices, and - stranded wires of 0,05 mm2 to 10 mm2 cross-section or - solid wires of 0,25 mm to 3,6 mm diameter; for use in electrical and electronic equipment. Information on the materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. This part of IEC 60352 is not applicable to crimping of coaxial cables. This part of IEC 60352 determines the suitability of solderless crimped connections as described above, under specified mechanical, electrical and atmospheric conditions and provides a means of comparing test results when the tools used to make the connections are of different designs or manufacture.
- Standard134 pagesEnglish languagesale 10% offe-Library read for×1 day
- 05-Dec-2024
- 29.120.20
- 31.220.10
- CLC/SR 48B
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-Nov-2024
- 31.220.10
- CLC/SR 48B
IEC 60512-28-100:2024 specifies the test methods for signal integrity and transmission performance for connectors specified in respective parts of IEC 60603-7, IEC61076-1, IEC 61076-2, IEC 61076-3 and IEC 63171 series of standards for connecting hardware applications from 0,1 MHz up to 2 000 MHz, with reference to this document. Note: This document is also suitable for testing signal integrity and transmission performance of connectors up to a lower value of maximum frequency; however, the test methodology specified in the detail specification for any given connector remains the reference conformance test for that connector. The list of connector series of standards does not preclude referencing this document in other connector manufacturer’s specifications or published standards. Test procedures provided herein are: - insertion loss, test 28a; - return loss, test 28b; - near-end crosstalk (NEXT) test 28c; - far-end crosstalk (FEXT), test 28d; - transverse conversion loss (TCL), test 28f; - transverse conversion transfer loss (TCTL), test 28g. Other test procedures referenced herein are: - shield transfer impedance (ZT), see IEC 60512‑26‑100, test 26e. - coupling attenuation (aC), see IEC 62153-4-7 and IEC 62153‑4‑12. - low frequency coupling attenuation (aCLF) see IEC 62153-4-7 and IEC 62153-4-15 This edition includes the following significant technical changes with respect to the previous edition: -The frequency range has been modified to start at 0,1 MHz instead of 1 MHz, to include single-pair connectors. -All tables and requirements have been revised down to 0,1 MHz, and partially improved to reduce the impact of the test fixture. -Formulae to calculate the S-parameters from single-ended parameters have been added. -A note was added for those parameters which are not applicable to single-pair connectors.
- Standard52 pagesEnglish languagesale 10% offe-Library read for×1 day
- 14-Nov-2024
- 31.220.10
- CLC/SR 48B
IEC 60352-9:2024 provides guidelines for welding and testing of ultrasonically welded connections and includes requirements, tests and practical guidance information. Ultrasonic welding is a form of cold friction welding that is becoming increasingly popular in many industries. This type of welding uses ultrasonic vibration to join materials together, creating a bond that is both strong and reliable. Ultrasonic welding has been identified as a process in ISO 4063-41 by the International Organization for Standardization (ISO). The process of ultrasonic welding relies on high frequency ultrasound waves being used to create frictional heat at the connection point. High temperature is not required for this special method of welding, making it one of the most cost-effective ways to join two materials together. It also requires fewer steps than traditional methods, meaning it can be completed quickly and with minimal resources. Ultrasonic welding has been around for decades but only recently has become more widely utilized due to advances in technology and its availability at lower cost. It can be used on many different materials including plastics, rubbers, metals, textiles, and composites. Due to its precision and strong bonds it creates, it has become extremely popular in manufacturing processes such as automotive industry, electronics industry, furniture production and even medical device production. This document covers ultrasonically welded connections made with stranded or flexible wires (class 2, 5 or 6 per IEC 60228) of copper or copper alloy, as well as of aluminium or aluminium alloy. These welded metal-to-metal connections shall employ wires with cross-sectional area of 0,08 mm2 to 160 mm2 and shall not exceed a total cross-sectional area, in case of wire bundle, of 200 mm2. For aluminium or aluminium alloy wires, the minimum required cross-sectional area is 2,5 mm2. Additionally, information on materials, data from industrial experience and test procedures are included to ensure electrically stable connections under prescribed environmental conditions. Lastly, this document aims to achieve comparable results when using ultrasonic welding equipment with similar performance and specifications as specified by the termination manufacturer.
- Standard71 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-Mar-2024
- 29.120.20
- 31.220.10
- CLC/SR 48B
IEC 61076-3-106:2023 constitutes a detail product specification for 8-way connectors for data transmission with frequencies up to 600 MHz. It covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in the IEC 60603-7 series to IP65/IP67 rating according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms according to this document and a variety of different mounting configurations and termination types which are detailed in the IEC 60603-7 series. Common mating configurations for all variants are defined in IEC 60603-7. The mating dimensions for the housings under Clause 3 allow the mating conditions under IEC 60603-7 to be fulfilled. The fully assembled variants (connectors) described in this document incorporate fully compliant IEC 60603-7 series fixed and free connectors.
- Standard41 pagesEnglish languagesale 10% offe-Library read for×1 day
- 31-Aug-2023
- 12-Jun-2022
- 31.220.10
- CLC/SR 48B
IEC 61076-2-115:2023 describes free and fixed 12P shielded circular connectors with 2 A rated current, rated voltage up to and including 50 V AC/DC, IP65/IP67 metal housing with push-pull locking (hereinafter referred to as a connectors) for use in electrical and electronic equipment. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.
- Standard39 pagesEnglish languagesale 10% offe-Library read for×1 day
- 29-Jun-2023
- 31.220.10
- CLC/SR 48B
IEC 61076-2-116:2022 specifies circular connectors size 15 with bayonet-locking, with up to 3 power contacts with rated insulation voltage up to 630 V AC/DC and rated current up to 20 A, plus PE, and up to 3 auxiliary contacts with rated insulation voltage up to 63 V AC/DC and rated current up to 10 A, that are typically used for industrial power supply and power applications, such as the feeding and control of 3-phase asynchronous motors. These connectors consist of both fixed and free connectors either rewireable or non-rewireable, with bayonet-locking. Male connectors have round contacts, either power or signal, Ø1,6 mm.
- Standard48 pagesEnglish languagesale 10% offe-Library read for×1 day
- 26-Jan-2023
- 31.220.10
- CLC/SR 48B
IEC 60512-27-200:2022 is primarily intended for use in signal integrity and transmission performance testing up to 2 000 MHz of IEC 60603-7 series 8-way connector type IEC 60603‑7‑81, according to connector test method IEC 60512‑28‑100. This part of IEC 60512 covers additional, supplemental test method specifications to extend the upper frequency for the test connectors and associated indirect-reference test fixtures used in the signal integrity and transmission performance tests specified in IEC 60512‑27‑100. In support of de-embedded crosstalk and related transmission requirements specified in IEC 60603‑7‑81, for frequencies up to 2 000 MHz, these supplemental specifications extend the upper test frequency from IEC 60512‑27‑100 up to 500 MHz to the upper test frequency of IEC 60512‑28‑100 up to 2 000 MHz. This document covers measurements of connector signal integrity and transmission performance of 8-way connector types defined in these published connector series standards: - IEC 60603‑7‑2 - IEC 60603‑7‑3 - IEC 60603‑7‑4 - IEC 60603‑7‑5 - IEC 60603‑7‑41 - IEC 60603‑7‑51 - IEC 60603‑7‑81. This document covers respective performance test procedures of connector signal integrity and transmission performance defined in these published connector test method series standards: - IEC 60512‑26‑100 - IEC 60512‑27‑100 - IEC 60512‑28‑100.
- Standard32 pagesEnglish languagesale 10% offe-Library read for×1 day
- 20-Oct-2022
- 31.220.10
- CLC/SR 48B
This part of IEC 63171 describes shielded or unshielded circular connectors with 2 ways and M8 or M12 Styles, typically used for data transmission up to 600 MHz and with current carrying capacity up to 4 A, for use in areas with harsh environmental conditions. These connectors consist of fixed and free connectors either rewirable or non-rewirable. Male connectors have square cross- section contacts, for data and power transmission. M12 describes the dimensions of the styles and thread of the screw-locking mechanism according IEC 61076-2-101 of this size of circular connectors. M8 describes the dimensions of the styles and thread of the screw-locking mechanism according IEC 61076-2-104. The use of alternative locking mechanisms according to IEC 61076-2-010 or IEC 61076-2-011 are possible. The coding provided by this standard prevents the mating of accordingly coded male or female connectors to other similarly sized interfaces covered by this or other standards. These Type 5 connectors are interoperable with Type 2 connectors according IEC 63171-2, except the locking and sealing system provided by the outer shell. The shielded and unshielded connectors are interoperable for their internal transmission performance and can be exchanged. The shielded version has improved EMC and coupling properties. This part of IEC 63171 covers Type 5 connectors. Each part of this series has the associated type number equal to the number of the part in the series. All connectors in the IEC 63171 series are deemed to provide the same functions as defined in IEC 63171:2021, using different mechanical interfaces.
- Standard36 pagesEnglish languagesale 10% offe-Library read for×1 day
- 20-Oct-2022
- 31.220.10
- CLC/SR 48B
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.