Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 3-2: Singlemode mechanical fibre splice

1.1 Product definition This European Standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements, which a singlemode mechanical splice shall meet in order for it to be categorised as an EN standard product. Since different variants and grades of performance are permitted, product marking and identification details are given in 3.5. Although in this document the product is qualified for EN 60793-2-50 types B1.1 and B1.3 singlemode fibres, it may also be suitable for other fibre types. 1.2 Interoperability The installed mechanical splice fits into a fibre management system with optical fibre splice cassettes or splice trays. This European Standard specifies the following two physical interface dimensions: a) cross sectional profile with width, height or diameter (in millimetres); b) length (in millimetres). 1.3 Expected performance In this document, the performance of a mechanical splice is given with identical fibres only. Losses associated with fibre cladding diameter and mode field mismatch are not taken into account. The measured attenuation is a function of the core concentricity, cladding non-circularity and alignment capability. The optical return loss performance is a function of the index matching gel and the fibre end face preparation. 1.4 Operating environment The tests selected combined with the severities and durations are representative of an outdoor enclosed environment defined as category U in EN 61753-1. To ensure that the product can be used in closures, boxes or street cabinet for categories A, G and S (as defined EN 61753-1) the specified lower temperature is extended to - 40 °C and requirements for temporary flooding have been added. 1.5 Reliability Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with this specification does not guarantee the reliability of the product. This should be predicted using a recognised reliability assessment programme. 1.6 Quality assurance Compliance with this specification does not guarantee the manufacturing consistency of the product. This standard does not cover quality insurance.

LWL-Spleißkassetten und -Muffen für die Anwendung in LWL Kommunikationssystemen - Produktnorm - Teil 3-2: Mechanische Spleiße für Einmodenfasern

Organiseurs et boîtiers de fibres destinés à être utilisés dans les systèmes de communication par fibres optiques - Spécifications de produit - Partie 3-2: Epissures mécaniques de fibres unimodales

Delilniki za optična vlakna in kabelske spojnice za optične komunikacijske sisteme - Specifikacije izdelka - 3-2. del: Enorodna mehanska optična spojnica

1.1 Opredelitev izdelka
Ta standard vsebuje začetne zahteve za dimenzije, optične in mehanske zahteve ter zahteve za okoljsko učinkovitost, ki jim mora ustrezati enorodna mehanska spojnica, da bi bila opredeljena kot izdelek standarda EN.
Ker so dovoljene različice in različne stopnje zmogljivosti, so podrobnosti o označevanju in identifikaciji izdelka navedene v 3.5.
Čeprav je v tem dokumentu izdelek kvalificiran za vrste B1.1 in B1.3 enorodnih vlaken po EN 60793-2-50, je lahko primeren tudi za druge vrste vlaken.
1.2 Medobratovalnost
Nameščena mehanska spojnica se prilega v sistem upravljanja vlaken s kasetami ali pladnji za optične spojnice. Ta evropski standard določa mere naslednjih dveh fizičnih vmesnikov:
a) prečni profil s širino, višino ali premerom (v milimetrih);
b) dolžina (v milimetrih).
1.3 Predvideno delovanje
V tem dokumentu je delovanje mehanske spojnice podano le z identičnimi vlakni. Izgube, povezane s premerom plašča vlakna in neskladjem rodovnega polja, niso upoštevane. Izmerjeno slabljenje je funkcija koncentričnosti sredice, nekrožnosti plašča in zmožnosti poravnave.
Optična povratna izguba je funkcija gela za indeksno združljivost in priprave zaključne strani vlakna.
1.4 Delovno okolje
Izbrani preskusi v kombinaciji s strogostjo in trajanjem predstavljajo zaprto okolje na prostem, opredeljeno kot kategorija U v EN 61753-1. Da bi zagotovili, da se izdelek lahko uporablja v ohišjih, škatlah ali uličnih omaricah za kategorije A, G in S (kot jih opredeljuje EN 61753-1), se je opredelitev za spodnjo temperaturo razširila do -40 °C in dodane so zahteve za začasno poplavo.
1.5 Zanesljivost
Medtem ko je pričakovana življenjska doba izdelka v tem okolju 20 let, skladnost s to specifikacijo ne jamči zanesljivosti izdelka. Ta se mora predvideti z uporabo priznanega programa za ocenjevanje zanesljivosti.
1.6 Zagotavljanje kakovosti
Skladnost s to specifikacijo ne jamči skladnosti izdelave izdelka. Ta standard ne zajema zagotavljanja kakovosti.

General Information

Status
Withdrawn
Publication Date
24-Mar-2011
Withdrawal Date
01-Jan-2014
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
21-Jul-2024
Completion Date
21-Jul-2024

Relations

Buy Standard

Standard
EN 50411-3-2:2011
English language
19 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-junij-2011
'HOLOQLNL]DRSWLþQDYODNQDLQNDEHOVNHVSRMQLFH]DRSWLþQHNRPXQLNDFLMVNHVLVWHPH
6SHFLILNDFLMHL]GHONDGHO(QRURGQDPHKDQVNDRSWLþQDVSRMQLFD
Fibre organisers and closures to be used in optical fibre communication systems -
Product specifications - Part 3-2: Singlemode mechanical fibre splice
LWL-Spleißkassetten und -Muffen für die Anwendung in LWL Kommunikationssystemen
- Produktnorm - Teil 3-2: Mechanische Spleiße von Einmodenfasern
Organiseurs et boîtiers de fibres destinés à être utilisés dans les systèmes de
communication par fibres optiques - Spécifications de produit - Partie 3-2 : Epissures
mécaniques de fibres unimodales
Ta slovenski standard je istoveten z: EN 50411-3-2:2011
ICS:
33.180.20 3RYH]RYDOQHQDSUDYH]D Fibre optic interconnecting
RSWLþQDYODNQD devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 50411-3-2
NORME EUROPÉENNE
March 2011
EUROPÄISCHE NORM
ICS 33.180.20
English version
Fibre organisers and closures to be used in optical fibre communication
systems -
Product specifications -
Part 3-2: Singlemode mechanical fibre splice

Organiseurs et boîtiers de fibres destinés LWL-Spleißkassetten und -Muffen für die
à être utilisés dans les systèmes de Anwendung in LWL
communication par fibres optiques - Kommunikationssystemen -
Spécifications de produit - Produktnorm -
Partie 3-2: Epissures mécaniques de Teil 3-2: Mechanische Spleiße für
fibres unimodales Einmodenfasern

This European Standard was approved by CENELEC on 2011-01-02. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50411-3-2:2011 E
Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 86BXA, Fibre optic
interconnect, passive and connectorised components.
The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50411-3-2 on
2011-01-02.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights.
The following dates were fixed:

– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2012-01-02

– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-01-02
__________
– 3 – EN 50411-3-2:2011
Fibre organisers and closures to be used in optical fibre communication systems –
Product specifications
Part 3-2: Singlemode mechanical fibre splice
Description Performance
Type: Fibre splice Application: EN 61753-1:2007, Category U
with extension of lower
Style: Mechanical
temperature to - 40 °C
Operating wavelength: 1 260 nm to 1 625 nm Attenuation grades Grade B:
≤ 0,25 dB maximum (97 %)
Grade C:
≤ 0,50 dB maximum (97 %)
Fibre category EN 60793-2-50 Return loss grades
Grade 1: ≥ 60 dB
Types B1.1 and B1.3
Grade 2: ≥ 45 dB
Grade 3: ≥ 35 dB
Related documents:
EN 60793-2-50 Optical fibres – Part 2-50: Product specifications – Sectional specification for
class B single-mode fibres (IEC 60793-2-50)
EN 60794-2-50 Optical fibre cables – Part 2-50: Indoor cables – Family specification for simplex
and duplex cables for use in terminated cable assemblies (IEC 60794-2-50)
EN 61300 series Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures (IEC 61300 series)
EN 61753-1:2007 Fibre optic interconnecting devices and passive components performance
standard – Part 1: General and guidance for performance standards
(IEC 61753-1:2007)
Outline and maximum dimensions:

Variant Dimension Dimension Dimension
W H L
mm mm mm
L
Type M1 3,8 6,4 38
H
4,0 4,0 36
Type M2
W
Type M3 3,2 3,2 45
Type M4 4,2 4,2 44
Type M5 4,0 4,0 40
Type M6 Ø 5,0 65
Contents
1 Scope . 5
1.1 Product definition . 5
1.2 Interoperability . 5
1.3 Expected performance . 5
1.4 Operating environment . 5
1.5 Reliability . 5
1.6 Quality assurance . 5
2 Normative references . 6
3 Description . 6
3.1 G ener al . 6
3.2 Mechanical splice . 7
3.3 Materials . 7
3.4 Dimensions . 7
3.5 Colour and marking . 7
4 Variants . 8
5 Dimensional requirements . 9
6 Tests . 9
6.1 Introduction . 9
6.2 Test sample preparation . 9
6.3 Test and measurement methods . 10
6.4 Pass/fail criteria . 10
7 Test report . 10
8 Performance requirements . 10
8.1 Dimensional and marking requirements . 10
8.2 Installation yield requirement . 10
8.3 Optical performance requirements . 11
Annex A (normative) Fibre type . 17
Annex B (normative) Sample size and product sourcing requirements . 18
Bibliography . 19

Figures
Figure 1 – Outline and maximum dimensions . 9

Tables
Table 1 – Optical fibre mechanical splice, for category U – variants . 8
Table 2 – Test details and requirements. 11
Table A.1 – Fibre type characteristics . 17
Table B.1 – Sample size per test . 18

– 5 – EN 50411-3-2:2011
1 Scope
1.1 Product definition
This European Standard contains the initial, start of life dimensional, optical, mechanical and environmental

performance requirements, which a singlemode mechanical splice shall meet in order for it to be categorised
as an EN standard product.
Since different variants and grades of performance are permitted, product marking and identification details
are given in 3.5.
Although in this document the product is qualified for EN 60793-2-50 types B1.1 and B1.3 singlemode fibres,
it may also be suitable for other fibre types.
1.2 Interoperability
The installed mechanical splice fits into a fibre management system with optical fibre splice cassettes or
splice trays. This European Standard specifies the following two physical interface dimensions:
a) cross sectional profile with width, height or diameter (in millimetres);
b) length (in millimetres).
1.3 Expected performance
In this document, the performance of a mechanical splice is given with identical fibres only. Losses
associated with fibre cladding diameter and mode field mismatch are not taken into account. The measured
attenuation is a function of the core concentricity, cladding non-circularity and alignment capability.
The optical return loss performance is a function of the index matching gel and the fibre end face preparation.
1.4 Operating environment
The tests selected combined with the severities and durations are representative of an outdoor enclosed
environment defined as category U in EN 61753-1. To ensure that the product can be used in closures,
boxes or street cabinet for categories A, G and S (as defined EN 61753-1) the specified lower temperature is
extended to - 40 °C and requirements for temporary flooding have been added.
1.5 Reliability
Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with
this specification does not guarantee the reliability of the product. This should be predicted using a
recognised reliability assessment programme.
1.6 Quality assurance
Compliance with this specification does not guarantee the manufacturing consistency of the product. This
standard does not cover quality insurance.

2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 60793-2-50 Optical fibres – Part 2-50: Product specifications – Sectional specification for class B
single-mode fibres (IEC 60793-2-50)
EN 61300 series Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures (IEC 61300 series)
EN 61300-2-1 Part 2-1: Tests – Vibration (sinusoidal) (IEC 61300-2-1)
EN 61300-2-4 Part 2-4: Tests – Fibre/cable retention (IEC 61300-2-4)
EN 61300-2-5 Part 2-5: Tests – Torsion/twist (IEC 61300-2-5)
EN 61300-2-7 Part 2-7: Tests – Bending moment (IEC 61300-2-7)
EN 61300-2-9 Part 2-9: Tests – Shock (IEC 61300-2-9)
EN 61300-2-17 Part 2-17: Tests – Cold (IEC 61300-2-17)
EN 61300-2-18 Part 2-18: Tests – Dry heat – High temperature endurance (IEC 61300-2-18)
EN 61300-2-22 Part 2-22: Tests – Change of temperature (IEC 61300-2-22)
EN 61300-2-26 Part 2-26: Tests – Salt mist (IEC 61300-2-26)
EN 61300-2-27 Part 2-27: Tests – Dust – Laminar flow (IEC 61300-2-27)
EN 61300-2-33 Part 2-33: Tests – Assembly and disassembly of fibre optic closures
(IEC 61300-2-33)
EN 61300-2-45 Part 2-45: Tests – Durability test by water immersion (IEC 61300-2-45)
EN 61300-2-46 Part 2-46: Tests – Damp heat cyclic (IEC 61300-2-46)
EN 61300-3-3:2009 Part 3-3: Examinations and measurements – Active monitoring of changes in
attenuation and return loss (IEC 61300-3-3:2009)
EN 61300-3-4:2001 Part 3-4: Examinations and measurements – Attenuation (IEC 61300-3-4:2001)
EN 61300-3-6:2009 Part 3-6: Examinations and measurements – Return loss (IEC 61300-3-6:2008)
EN 61300-3-7:2001 Part 3-7: Examinations and measurements – Wavelength dependence of attenuation
and return loss (IEC 61300-3-7:2000)
EN 61300-3-28:2002 Part 3-28: Examinations and measurements – Transient loss (IEC 61300-3-
...