Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables

EN 50264-2-1 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: • 0,6/1 kV unscreened, unsheathed (1 mm² to 400 mm²); • 1,8/3 kV unscreened, unsheathed (1,5 mm² to 400 mm²); • 1,8/3 kV unscreened, sheathed (1,5 mm² to 400 mm²); • 3,6/6 kV unscreened, sheathed (2,5 mm² to 400 mm²). All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-2-1 should be read in conjunction with Part 1 “General requirements”.

Bahnanwendungen - Starkstrom- und Steuerleitungen für Schienenfahrzeuge mit verbessertem Verhalten im Brandfall - Teil 2-1: Leitungen mit vernetzter elastomerer Isolierung - Einadrige Leitungen

EN 50264-2-1 legt Anforderungen an und Aufbauten und Abmessungen von einadrigen Leitungen für folgende Bauarten und Nennspannungen fest: • 0,6/1 kV ohne Schirm, ohne Mantel (1 mm² bis 400 mm²); • 1,8/3 kV ohne Schirm, ohne Mantel (1,5 mm² bis 400 mm²); • 1,8/3 kV ohne Schirm, mit Mantel (1,5 mm² bis 400 mm²); • 3,6/6 kV ohne Schirm, mit Mantel (2,5 mm² bis 400 mm²). Alle Leitungen haben einen verzinnten Kupferleiter Klasse 5 nach EN 60228, eine halogenfreie Isolierung und gegebenenfalls einen halogenfreien Mantel. Sie sind für feste Verlegung im Schienenfahrzeug bestimmt oder für Verdrahtungen, bei denen im Betrieb begrenzt mit Bewegungen gerechnet werden muss. Die Anforderungen berücksichtigen eine dauernde Leitertemperatur von nicht mehr als 90 °C und eine maximale Kurzschlusstemperatur von 200 °C bei einer Dauer von 5 s. Unter Brandbedingungen zeigen die Leitungen besondere Leistungsmerkmale hinsichtlich der maximal zulässigen Weiterleitung der Flammen (Ausbreitung der Flammen) und der höchsten zulässigen Emission von Rauch und giftigen Gasen. EN 50264-2-1 sollte in Verbindung mit Teil 1 „Allgemeine Anforderungen“ gelesen werden.

Applications ferroviaires - Câbles de puissance et de contrôle à comportement au feu spécifié pour matériel roulant ferroviaire - Partie 2-1: Câbles à enveloppe isolante réticulée - Câbles monoconducteurs

La EN 50264-2-1 spécifie les prescriptions, les constructions et les dimensions des câbles monoconducteurs des types et tensions assignées suivants: • 0,6/1 kV sans blindage ni gaine (de 1 mm² à 400 mm²); • 1,8/3 kV sans blindage ni gaine (de 1,5 mm² à 400 mm²); • 1,8/3 kV gainé sans blindage (de 1,5 mm² à 400 mm²); • 3,6/6 kV gainé sans blindage (de 2,5 mm² à 400 mm²). Tous les câbles monoconducteurs possèdent une âme en cuivre étamé de classe 5 selon la EN 60228, une isolation et une gaine sans halogènes. Ils sont destinés aux installations fixes ou soumis à de faibles flexions en service des matériels roulants ferroviaires. Les prescriptions sont basées pour une température permanente à l’âme ne dépassant pas 90 °C et à une température maximale de 200 °C pour une durée de 5 s en cas de court-circuit. Les câbles monoconducteurs présentent, en cas d’incendie, des performances particulières de propagation maximale admissible de la flamme (longueur brûlée) et d’émission de fumées et de gaz toxiques. Il est recommandé de lire la EN 50264-2-1 conjointement avec la Partie 1 “Prescriptions générales”.

Železniške naprave - Energetski in krmilni kabli za železniška vozna sredstva, ki imajo posebne ognjevarne lastnosti - 2-1. del: Kabli z zamreženo elastomerno izolacijo - Enožilni kabli

General Information

Status
Published
Publication Date
26-Jun-2008
Withdrawal Date
28-Feb-2011
Technical Committee
Drafting Committee
Parallel Committee
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
29-Sep-2021

Relations

Buy Standard

Standard
EN 50264-2-1:2008
English language
25 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 50264-2-1:2008
01-september-2008
1DGRPHãþD
SIST EN 50264-2:2003
Železniške naprave - Energetski in krmilni kabli za železniška vozna sredstva, ki
imajo posebne ognjevarne lastnosti - 2-1. del: Kabli z zamreženo elastomerno
izolacijo - Enožilni kabli
Railway applications - Railway rolling stock power and control cables having special fire
performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core
cables
Bahnanwendungen - Starkstrom- und Steuerleitungen für Schienenfahrzeuge mit
verbessertem Verhalten im Brandfall -- Teil 2-1: Leitungen mit vernetzter elastomerer
Isolierung - Einadrige Leitungen
Applications ferroviaires - Câbles de puissance et de contrôle à comportement au feu
spécifié pour matériel roulant ferroviaire -- Partie 2-1: Câbles à enveloppe isolante
réticulée - Câbles monoconducteurs
Ta slovenski standard je istoveten z: EN 50264-2-1:2008
ICS:
13.220.20 3RåDUQD]DãþLWD Fire protection
29.060.20 Kabli Cables
45.060.01 Železniška vozila na splošno Railway rolling stock in
general
SIST EN 50264-2-1:2008 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 50264-2-1:2008

---------------------- Page: 2 ----------------------

SIST EN 50264-2-1:2008


EUROPEAN STANDARD
EN 50264-2-1

NORME EUROPÉENNE
June 2008
EUROPÄISCHE NORM

ICS 13.220.20; 29.060.20; 45.060.01 Supersedes EN 50264-2:2002


English version


Railway applications -
Railway rolling stock power and control cables
having special fire performance -
Part 2-1: Cables with crosslinked elastomeric insulation -
Single core cables




Applications ferroviaires - Bahnanwendungen -
Câbles de puissance et de contrôle Starkstrom- und Steuerleitungen
à comportement au feu spécifié für Schienenfahrzeuge
pour matériel roulant ferroviaire - mit verbessertem Verhalten im Brandfall -
Partie 2-1: Câbles à enveloppe Teil 2-1: Leitungen mit vernetzter
isolante réticulée - elastomerer Isolierung -
Câbles monoconducteurs Einadrige Leitungen




This European Standard was approved by CENELEC on 2008-03-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50264-2-1:2008 E

---------------------- Page: 3 ----------------------

SIST EN 50264-2-1:2008
EN 50264-2-1:2008 – 2 –
Foreword
This European Standard was prepared by Working Group 12, Railway cables, of the Technical Committee
CENELEC TC 20, Electric cables, as part of the overall programme of work in the Technical Committee
CENELEC TC 9X, Electrical and electronic applications for railways.
The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50264-2-1 on
2008-03-01.
This European Standard supersedes EN 50264-2:2002.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
(dop) 2009-03-01
national standard or by endorsement
– latest date by which the national standards conflicting
(dow) 2011-03-01
with the EN have to be withdrawn
__________

---------------------- Page: 4 ----------------------

SIST EN 50264-2-1:2008
– 3 – EN 50264-2-1:2008
Contents
Page

Introduction . 5
1 Scope .
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.