Low-voltage switchgear and controlgear assemblies - Part 8: Assemblies for use in photovoltaic installations

Sestavi nizkonapetostnih stikalnih in krmilnih naprav - 8. del: Sestavi za uporabo v fotonapetostnih inštalacijah

General Information

Status
Not Published
Publication Date
14-Dec-2025
Current Stage
4020 - Enquiry circulated - Enquiry
Start Date
24-May-2024
Due Date
30-Aug-2024
Completion Date
24-May-2024

Buy Standard

Draft
prEN IEC 61439-8:2024 - BARVE
English language
47 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
oSIST prEN IEC 61439-8:2024
01-julij-2024
Sestavi nizkonapetostnih stikalnih in krmilnih naprav - 8. del: Sestavi za uporabo v
fotonapetostnih inštalacijah
Low-voltage switchgear and controlgear assemblies - Part 8: Assemblies for use in
photovoltaic installations
Ta slovenski standard je istoveten z: prEN IEC 61439-8:2024
ICS:
29.130.20 Nizkonapetostne stikalne in Low voltage switchgear and
krmilne naprave controlgear
oSIST prEN IEC 61439-8:2024 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN IEC 61439-8:2024

---------------------- Page: 2 ----------------------
oSIST prEN IEC 61439-8:2024
121B/199/CDV

COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 61439-8 ED1
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2024-05-24 2024-08-16
SUPERSEDES DOCUMENTS:
121B/185/CD, 121B/198/CC

IEC SC 121B : LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES
SECRETARIAT: SECRETARY:
Germany Mr Jörg Hußmann
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:

TC 23,SC 23E,TC 64,TC 82,SC 121A
Other TC/SCs are requested to indicate their interest, if
any, in this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.

This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of
which they are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some
Countries” clauses to be included should this proposal proceed. Recipients are reminded that the CDV stage is
the final stage for submitting ISC clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).

TITLE:
Low-voltage switchgear and controlgear assemblies - Part 8: Assemblies for use in
photovoltaic installations

PROPOSED STABILITY DATE: 2028

NOTE FROM TC/SC OFFICERS:


Copyright © 2024 International Electrotechnical Commission, IEC. All rights reserved. It is permitted to
download this electronic file, to make a copy and to print out the content for the sole purpose of preparing National
Committee positions. You may not copy or "mirror" the file or printed version of the document, or any part of it,
for any other purpose without permission in writing from IEC.

---------------------- Page: 3 ----------------------
oSIST prEN IEC 61439-8:2024
IEC CDV 61439-8 © IEC 2024 2 121B/199/CDV

1 CONTENTS
2 CONTENTS . 2
3 FOREWORD . 5
4 INTRODUCTION . 7
5 1 Scope . 8
6 2 Normative references . 8
7 3 Terms and definitions . 9
8 3.1 General terms . 10
9 3.1.101 photovoltaic assembly . 10
10 3.1.102 PV string . 10
11 3.1.103 photovoltaic string combiner box. 10
12 3.1.104 photovoltaic array combiner box . 10
13 3.1.105 test situation . 10
14 3.1.106 form of internal separation . 10
15 3.1.107 Solar irradiance . 10
16 3.2 Constructional units of assemblies . 10
17 3.2 Constructional units of PVAs
...

Questions, Comments and Discussion