Radio-frequency connectors - Part 71: Sectional specification for RF coaxial connectors with inner diameter of outer conductor 5 mm - Characteristic impedance 50 Ohms - type NEX10®

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial connector, typically for use in 50 Ω radio communication systems, type NEX10®. This document describes mating face dimensions for general purpose connectors - grade 2, dimensional details of standard test connectors-grade 1, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to type NEX10® RF coaxial connectors. This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. The type NEX10® RF coaxial connectors are used with all kinds of RF cables and microstrip circuits in radio frequency transmission systems with operating frequencies up to 20 GHz. NOTE Metric dimension are original dimensions. All undimensioned pictorial configurations are for reference purpose only.

Hochfrequenz-Steckverbinder - Teil 71: Rahmenspezifikation für koaxiale HF-Steckverbinder mit 5,0 mm Innendurchmesser des Außenleiters - Wellenwiderstand 50 Ω (Typ NEX10®)

Connecteurs pour fréquences radioélectriques - Partie 71: Spécification intermédiaire pour connecteurs RF coaxiaux avec conducteur extérieur présentant un diamètre intérieur de 5 mm - Impédance caractéristique de 50 ohms (type NEX10®)

IEC 61169-71:2022, qui est une spécification intermédiaire (SI), fournit des informations et des règles pour l’établissement de spécifications particulières (SP) relatives aux connecteurs RF coaxiaux, généralement utilisés dans les systèmes de radiocommunication de 50 Ω, de type NEX10® [1]. Le présent document décrit les dimensions des interfaces d’accouplement pour les connecteurs à usage général (grade 2), les détails dimensionnels des connecteurs d’essai normalisés (grade 1), les informations relatives aux calibres et les essais choisis à partir de l’IEC 61169-1, applicables à toutes les spécifications particulières relatives aux connecteurs RF coaxiaux de type NEX10®. Le présent document indique les caractéristiques de performance recommandées à prendre en considération pour la rédaction d’une spécification particulière et elle couvre les programmes d’essai et les exigences de contrôle pour les niveaux d’assurance M et H.

Radiofrekvenčni konektorji - 71. del: Področna specifikacija za radiofrekvenčne (RF) koaksialne konektorje z notranjim premerom zunanjega vodnika 5 mm - Karakteristična impedanca 50 ohm (tip NEX10®) (IEC 61169-71:2022)

Ta del standarda IEC 61169, ki je področna specifikacija (SS), podaja informacije in določa pravila za pripravo podrobnih specifikacij (DS) za radiofrekvenčne koaksialne konektorje, običajno za uporabo v 50-ohmskih sistemih radijske komunikacije (tip NEX10®).
Ta dokument opisuje mere spojne površine za konektorje za splošni namen tipa 2, podrobnosti o merah standardnih preskusnih konektorjev tipa 1, informacije o merjenju in preskuse, izbrane iz standarda IEC 61169-1, ki veljajo za vse podrobne specifikacije v zvezi z radiofrekvenčnimi koaksialnimi konektorji tipa NEX10®.
Ta specifikacija navaja priporočene lastnosti, ki jih je treba upoštevati pri sestavljanju podrobne specifikacije, ter zajema razporede preskusov in zahteve za pregled za ravni vrednotenja M in H.
Radiofrekvenčni koaksialni konektorji tipa NEX10® se uporabljajo z različnimi radiofrekvenčnimi kabli in mikrotrakovnimi vezji v sistemih radiofrekvenčnega prenosa s frekvenčnim območjem delovanja do 20 GHz.
OPOMBA: Izvirne mere so podane v metričnih merah. Vse nedimenzionirane slikovne konfiguracije so podane samo v referenčne namene.

General Information

Status
Published
Publication Date
21-Jul-2022
Current Stage
6060 - Document made available - Publishing
Start Date
22-Jul-2022
Due Date
30-Nov-2021
Completion Date
22-Jul-2022

Buy Standard

Standard
EN IEC 61169-71:2022
English language
35 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2022
Radiofrekvenčni konektorji - 71. del: Področna specifikacija za radiofrekvenčne
(RF) koaksialne konektorje z notranjim premerom zunanjega vodnika 5 mm -
Karakteristična impedanca 50 ohm (tip NEX10®) (IEC 61169-71:2022)
Radio-frequency connectors - Part 71: Sectional specification for RF coaxial connectors
with inner diameter of outer conductor 5 mm - Characteristic impedance 50 Ohms - type
NEX10® (IEC 61169-71:2022)
Hochfrequenz-Steckverbinder - Teil 71: Rahmenspezifikation für koaxiale HF-
Steckverbinder mit 5,0 mm Innendurchmesser des Außenleiters - Wellenwiderstand 50
Ω (Typ NEX10®) (IEC 61169-71:2022)
Connecteurs pour fréquences radioélectriques - Partie 71: Spécification intermédiaire
pour connecteurs RF coaxiaux avec conducteur extérieur présentant un diamètre
intérieur de 5 mm - Impédance caractéristique de 50 ohms (type NEX10®) (IEC 61169-
71:2022)
Ta slovenski standard je istoveten z: EN IEC 61169-71:2022
ICS:
33.120.30 Radiofrekvenčni konektorji RF connectors
(RF)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN IEC 61169-71

NORME EUROPÉENNE
EUROPÄISCHE NORM July 2022
ICS 33.120.30
English Version
Radio-frequency connectors - Part 71: Sectional specification for
RF coaxial connectors with inner diameter of outer conductor 5
mm - Characteristic impedance 50 Ohms - type NEX10®
(IEC 61169-71:2022)
Connecteurs pour fréquences radioélectriques - Partie 71: Hochfrequenz-Steckverbinder - Teil 71:
Spécification intermédiaire pour connecteurs RF coaxiaux Rahmenspezifikation für koaxiale HF-Steckverbinder mit 5,0
avec conducteur extérieur présentant un diamètre intérieur mm Innendurchmesser des Außenleiters -
de 5 mm - Impédance caractéristique de 50 ohms (type Wellenwiderstand 50 Ω (Typ NEX10®)
NEX10®) (IEC 61169-71:2022)
(IEC 61169-71:2022)
This European Standard was approved by CENELEC on 2022-07-04. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 61169-71:2022 E

European foreword
The text of document 46F/618/FDIS, future edition 1 of IEC 61169-71, prepared by SC 46F "RF and
microwave passive components" of IEC/TC 46 "Cables, wires, waveguides, RF connectors, RF and
microwave passive components and accessories" was submitted to the IEC-CENELEC parallel vote
and approved by CENELEC as EN IEC 61169-71:2022.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2023-04-04
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2025-07-04
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
Endorsement notice
The text of the International Standard IEC 61169-71:2022 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards
indicated:
IEC 62305-1 NOTE Harmonized as EN 62305-1
IEC 62037-1:2012 NOTE Harmonized as EN 62037-1:2012 (not modified)
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod), the
relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 61169-1 2013 Radio frequency connectors - Part 1: EN 61169-1 2013
Generic specification - General
requirements and measuring methods
IEC 62153-4-7 - Metallic cables and other passive EN IEC 62153-4-7 -
components test methods - Part 4-7:
Electromagnetic compatibility (EMC) -Test
method for measuring of transfer
impedance Z and screening attenuation
T
aS or coupling attenuation aC of connectors
and assemblies - Triaxial tube in tube
method
ISO 3290-1 - Rolling bearings - Balls - Part 1: Steel balls - -

IEC 61169-71 ®
Edition 1.0 2022-05
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Radio-frequency connectors –
Part 71: Sectional specification for RF coaxial connectors with inner diameter of

outer conductor 5 mm – Characteristic impedance 50 Ohms – type NEX10®

Connecteurs pour fréquences radioélectriques –

Partie 71: Spécification intermédiaire pour connecteurs RF coaxiaux avec

conducteur extérieur présentant un diamètre intérieur de 5 mm – Impédance

caractéristique de 50 ohms (type NEX10®)

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.120.30 ISBN 978-2-8322-1430-5

– 2 – IEC 61169-71:2022 © IEC 2022
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 7
4 Mating face and gauge information . 8
4.1 General purpose connector: Grade 2 . 8
4.1.1 Screw type connector with pin centre contact . 8
4.1.2 Quick lock type connector with pin centre contact . 9
4.1.3 Connector with socket centre contact . 11
4.2 Gauges . 13
4.2.1 Gauge pin for socket centre contact. 13
4.2.2 Gauge rings for plug outer contact . 14
4.3 Standard test connectors: Grade 1 . 15
4.3.1 Standard test connector with pin centre contact . 15
4.3.2 Standard test connector with socket centre contact . 17
5 Quality assessment procedures . 20
5.1 General . 20
5.2 Ratings and characteristics . 20
5.3 Test schedule and inspection requirements. 22
5.3.1 Acceptance tests . 22
5.3.2 Periodic tests . 23
5.4 Procedures for the quality conformance . 25
5.4.1 Quality conformance inspection . 25
5.4.2 Qualification approval and its maintenance . 25
6 Instructions for preparation of detail specifications . 26
6.1 General . 26
6.2 Identification of the component . 26
6.3 Performances . 26
6.4 Marking, ordering information and related matters . 26
6.5 Selection of tests, test conditions and severities . 26
6.6 Blank detail specification pro-forma for RF coaxial connector with inner
diameter of outer conductor 5 mm with screw coupling-characteristic
impedance 50 ohms (type NEX10®) . 27
Bibliography . 32

Figure 1 – Screw type connector with pin centre contact . 8
Figure 2 – Quick lock type connector with pin centre contact W . 10
Figure 3 – Connector with socket centre contact . 12
Figure 4 – Gauge pin for socket centre contact . 14
Figure 5 – Gauge rings for plug outer contact . 15
Figure 6 – Standard test connector with pin centre contact interface . 16
Figure 7 – Standard test connector with socket centre contact interface . 18

Table 1 – Dimensions of screw type connector with pin centre contact . 9

IEC 61169-71:2022 © IEC 2022 – 3 –
Table 2 – Dimensions of quick lock type connector with pin centre contact . 10
Table 3 – Dimensions of connector with socket centre contact . 13
Table 4 – Dimensions of gauge pin for socket centre contact . 14
Table 5 – Dimensions of gauge rings for plug outer contact . 15
Table 6 – Interface dimensions of standard test connector with pin centre contact . 17
Table 7 – Interface dimensions of standard test connector with socket centre contact . 19
Table 8 – Ratings and characteristics . 20
Table 9 – Acceptance tests . 23
Table 10 – Periodic tests . 24

– 4 – IEC 61169-71:2022 © IEC 2022
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 71: Sectional specification for RF coaxial connectors
with inner diameter of outer conductor 5 mm –
Characteristic impedance 50 Ohms – type NEX10®

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Av
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.