Alarm systems - Intrusion and hold-up systems - Part 2-8: Intrusion detectors - Shock detectors

This Technical Specification is for shock detectors installed in buildings to detect the shock or series of shocks due to a forcible attack through a physical barrier (for example doors or windows). It provides for security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free detectors and uses Environmental Classes i-iv (see EN 50130-5). This Technical Specification does not include requirements for detectors intended to protect for example vaults and safes from penetration attacks from e.g. drilling, cutting or thermal lance. This Technical Specification does not include requirements for shock detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this Technical Specification may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions. This Technical Specification does not apply to system interconnections.

Alarmanlagen - Einbruchmeldeanlagen - Teil 2-8: Anforderungen an Erschütterungsmelder

Systèmes d'alarme - Systèmes d'alarme contre l’intrusion et les hold-up - Partie 2-8: Détecteurs d’intrusion - Détecteurs de chocs

Alarmni sistemi - Sistemi za javljanje vloma in ropa - 2-8. del: Javljalniki vloma - Javljalniki udara - Dopolnilo IS1

General Information

Status
Withdrawn
Publication Date
27-Feb-2014
Technical Committee
Drafting Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
03-Oct-2019

Relations

Buy Standard

Addendum
TS CLC/TS 50131-2-8:2012/IS1:2014
English language
6 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST-TS CLC/TS 50131-2-8:2012/IS1:2014
01-december-2014
Alarmni sistemi - Sistemi za javljanje vloma in ropa - 2-8. del: Javljalniki vloma -
Javljalniki udara - Dopolnilo IS1
Alarm systems - Intrusion and hold-up systems - Part 2-8: Intrusion detectors - Shock
detectors
Alarmanlagen - Einbruchmeldeanlagen - Teil 2-8: Anforderungen an
Erschütterungsmelder
Systèmes d'alarme - Systèmes d'alarme contre l’intrusion et les hold-up - Partie 2-8:
Détecteurs d’intrusion - Détecteurs de chocs
Ta slovenski standard je istoveten z: CLC/TS 50131-2-8:2012/IS1:2014
ICS:
13.310 Varstvo pred kriminalom Protection against crime
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
SIST-TS CLC/TS 50131-2- en,fr,de
8:2012/IS1:2014
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST-TS CLC/TS 50131-2-8:2012/IS1:2014

---------------------- Page: 2 ----------------------

SIST-TS CLC/TS 50131-2-8:2012/IS1:2014

INTERPRETATION SHEET
CLC/TS 50131-2-8/IS1

FEUILLE D'INTERPRETATION
February 2014
INTERPRETATIONSBLATT

ICS 13.320


English version


Alarm systems -
Intrusion and hold-up systems -
Part 2-8: Intrusion detectors -
Shock detectors



Systèmes d'alarme -  Alarmanlagen -
Systèmes d'alarme contre l’intrusion et les Einbruchmeldeanlagen -
hold-up - Teil 2-8: Anforderungen an
Partie 2-8: Détecteurs d’intrusion - Erschütterungsmelder
Détecteurs de chocs







This Technical Specification was approved by CENELEC on 2013-12-23.

CENELEC members are required to announce the existence of this TS in the same way as for an EN and to
make the TS available promptly at national level in an appropriate form. It is permissible to keep conflicting
national standards in force.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.



CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2014 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. CLC/TS 50131-2-8:2012/IS1:2014 E

---------------------- Page: 3 ----------------------

SIST-TS CLC/TS 50131-2-8:2012/IS1:2014
CLC/TS 50131-2-8:2012/IS1:2014 (E)
Contents Page

Foreword . 3
Clause: . 4
Question: . 4
Interpretation: . 4
Validity: . 4

2

---------------------- Page: 4 ----------------------

SIST-TS CLC/TS 50131-2-8:2012/IS1:2014
CLC/TS 50131-2-8:2012/IS1:2014 (E)
Foreword
This Interpretation Sheet to the European Standard CLC/TS 50131-2-8:2012 was prepared by CLC/TC 79
"Alarm systems".
3

---------------------- Page: 5 ----------------------

SIST-TS CLC/TS 50131-2-8:2012/IS1:2014
CLC/TS 50131-2-8:2012/IS1:2014 (E)
Text of IS1 to EN 50131-2-8:2012
Clause:
Annex B and Figure B.1
Question:
Would it be allowed for test purposes (for test houses and manufacturers) to use the NeoDym magnet listed
below instead of the AlNiCo version described in Annex B and Figure B.1 for reproducible tests ?
Interpretation:
Yes, because this will allow stable and reproducible test results, which is not guaranteed while using the
AlNiCo magnet due to the nature of the magnet material. Furthermore, the test magnet described below
allows a high-level degree of backward compatibility for already tested products, while it gives the stability
required.
Therefore, when the NeoDym magnet is used for test purposes (for test houses and manufacturers), the text
below may be used in place of Annex B.
Validity:
This interpretation remains valid until an amendment or updated standard de
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.