Solderless connections - Part 4: Solderless non-accessible insulation displacement connections - General requirements, test methods and practical guidance

Is applicable to non-accessible ID connections which are made with: appropriately designed ID terminations; -wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter; -wires having stranded conductors of 0,05 mm2 to 10 mm2 cross section.

Lötfreie elektrische Verbindungen - Teil 4: Lötfreie nichtzugängliche Schneidklemmverbindungen - Allgemeine Anforderungen, Prüfverfahren und Anwendungshinweise

Connexions sans soudure - Partie 4: Connexions autodénudantes, non accessibles sans soudure - Règles générales, méthodes d'essai et guide pratique

S'applique aux connexions CAD qui sont non accessibles et qui sont composées de: - contacts CAD de conception appropriées; - fils à conducteur cylindrique massif de diamètre nominal 0,25 mm à 3,6 mm; - fils à conducteur divisé de section 0,05 mm2 à 10 mm2.

Solderless connections - Part 4: Solderless non-accessible insulation displacement connections - General requirements, test methods and practical guidance (IEC 60352-4:1994)

General Information

Status
Withdrawn
Publication Date
19-Oct-1994
Withdrawal Date
30-Sep-1995
Technical Committee
Drafting Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
16-Jul-2023
Completion Date
16-Jul-2023

Relations

Buy Standard

Standard
EN 60352-4:2002
English language
40 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2002
Solderless connections - Part 4: Solderless non-accessible insulation
displacement connections - General requirements, test methods and practical
guidance (IEC 60352-4:1994)
Solderless connections -- Part 4: Solderless non-accessible insulation displacement
connections - General requirements, test methods and practical guidance
Lötfreie elektrische Verbindungen -- Teil 4: Lötfreie nichtzugängliche
Schneidklemmverbindungen - Allgemeine Anforderungen, Prüfverfahren und
Anwendungshinweise
Connexions sans soudure -- Partie 4: Connexions autodénudantes, non accessibles
sans soudure - Règles générales, méthodes d'essai et guide pratique
Ta slovenski standard je istoveten z: EN 60352-4:1994
ICS:
29.120.20 Spojni elementi Connecting devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

CEI
NORME
IEC
INTERNATIONALE
352-4
INTERNATIONAL
Première édition
STANDARD
First edition
1994-08
Connexions sans soudure –
Partie 4:
Connexions autodénudantes, non accessibles
sans soudure –
Règles générales, méthodes d'essai et
guide pratique
Solderless connections –
Part 4:
Solderless non-accessible insulation
displacement connections –
General requirements, test methods
and practical guidance
© CEI 1994 Droits de reproduction réservés — Copyright — all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun pro- any form or by any means, electronic or mechanical,
cédé, électronique ou mécanique, y compris la photocopie et including photocopying and microfilm, without permission
les microfilms, sans l'accord écrit de l'éditeur. in writing from the publisher.
Bureau Central de la Commission Electrotechnique Internationale 3, rue de Varembé Genève, Suisse
Commission Electrotechnique Internationale CODE PRIX , A'
International Electrotechnical Commission
PRICE CODE VV
MemnyHapopitaa 3neKrporexmoiecKae KOMKCCKa
IEC
Pour prix, voir catalogue en vigueur
• •
For price, see current catalogue

352-4 © IEC:1994 – 3 –
CONTENTS
Page
FOREWORD 5
INTRODUCTION 9
SECTION 1: GENERAL
Clause
1 Scope 11
2 Object 11
3 Normative references 11
4 Definitions 15
5 IEC type designation 19
SECTION 2: REQUIREMENTS
6 Workmanship
7 Tools
8 Insulation displacement termination (ID termination)
9 Wires 23
10 Non-accessible insulation displacement connections (ID connections) 25
SECTION 3: TESTS
11 Testing 27
12 Type tests 29
13 Test schedules 45
SECTION 4: PRACTICAL GUIDANCE
14 Current-carrying capacity 63
15 Tool information 63
16 Termination information 63
17 Wire information 65
18 Connection information 67

352-4 – 5 –
© IEC:1994
INTERNATIONAL ELECTROTECHNICAL COMMISSION
SOLDERLESS CONNECTIONS –
Part 4: Solderless non-accessible insulation
displacement connections –
General requirements, test methods and practical guidance
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization
comprising all national electrotechnical committees (IEC National Committees). The object of the IEC is to
promote international cooperation on all questions concerning standardization in the electrical and
electronic fields. To this end and in addition to other activities, the IEC publishes International Standards.
Their preparation is entrusted to technical committees; any IEC National Committee interested in
the subject dealt with may participate in this preparatory work. International, governmental and
non-governmental organizations liaising with the IEC also participate in this preparation. The IEC
collaborates closely with the International Organization for Standardization (ISO) in accordance with
conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of the IEC on technical matters, prepared by technical committees on
which all the National Committees having a special interest therein are represented, express, as nearly as
possible, an international consensus of opinion on the subjects dealt with.
3) They have the form of recommendations for international use published in the form of standards, technical
reports or guides and they are accepted by the National Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
International Standard IEC 352-4 has been prepared by IEC sub-committee 48B: Con-
nectors, of IEC technical committee 48: Electromechanical components and mechanical
structures for electronic equipment.
The text of this standard is based on the following documents:
DIS Report on voting
48B(CO)251 48B(CO)256
Full information on the voting for the approval of this standard can be found in the report
on voting indicated in the above table.
IEC 352 consists of the following parts, under the general title: Solderless connections:
– Part 1: 1983, Solderless wrapped connections – General requirements, test
methods and practical guidance
– Part 2: 1990, Solderless crimped connections – General requirements, test methods
and practical guidance
352-4 © IEC:1994 - 7 -
- Solderless accessible insulation displacement connections - General
Part 3: 1993,
requirements, test methods and practical guidance
- rt 4: 1994, Solderless non-accessible insulation displacement connections -
Pa
General requirements, test methods and practical guidance

352-4 © IEC:1994 – 9 –
INTRODUCTION
The two following parts of IEC 352 are available on solderless insulation displacement
connections:
Part 3: Solderless accessible insulation displacement connections – General

requirements, test methods and practical guidance;
Part 4: Solderless non-accessible insulation displacement connections – General

requirements, test methods and practical guidance.
These parts include requirements, tests and practical guidance information.
Two test schedules are provided:
basic test schedule which applies to insulation displacement connections which
– the
of section 2 of this standard;
conform to all requirements
These requirements are derived from experience with successful applications of such
connections.
full which applies to insulation displacement connections which do
– the test schedule
section 2, for example which are manufactured
not fully conform to all requirements of
using materials or finishes not included in section 2.
This philosophy permits cost and time effective performance verification using a limited
basic test schedule for established insulation displacement connections and an
expanded full test schedule for connections requiring more extensive performance
validation.
NOTE — In this standard the term "insulation displacement" is abbreviated to "ID", for example "ID connec-
tion", 'ID termination".
Non-accessible ID
Accessible ID
connection
connection
/EC 026/93
!EC 025/93
and non-accessible insulation
Figure 1 – Examples of accessible
displacement connections
352-4 ©IEC:1994 — 11 —
SOLDERLESS CONNECTIONS –
Part 4: Solderless non-accessible insulation
displacement connections –
General requirements, test methods and practical guidance
Section 1: General
1 Scope
This part of IEC 352 is applicable to non-accessible ID connections for which the tests and
measurements of section 3 are suitable and which are made with:
appropriately designed ID terminations;

wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter;

2 to 10 mm 2 cross-section;
— wires having stranded conductors of 0,05 mm
for use in telecommunication equipment and in electronic devices employing similar
techniques.
Information on materials and data from industrial experience is included in addition to the
test procedures to provide electrically stable connections under prescribed environmental
conditions.
2 Object
The object of this part of IEC 352 is to:
determine the suitability of non-accessible ID connections under specified mech-

anical, electrical and atmospheric conditions;
— provide a means of comparing test results when the tools used to make the
connections are of different designs or manufacture.
There are different designs and materials for ID terminations in use. For this reason only
fundamental parameters of the termination are specified while the performance require-
ments of the wire and the complete connection are specified in full detail.
3 Normative references
The following normative documents contain provisions which, through reference in this
text, constitute provisions of this part of IEC 352. At the time of publication, the editions
rties to
indicated were valid. All normative documents are subject to revision, and pa
agreements based on this part of IEC 352 are encouraged to investigate the possibility
of applying the most recent editions of the normative documents indicated below.
Members of IEC and ISO maintain registers of currently valid International Standards.

352-4 ©IEC:1994 - 13 -
International Electrotechnical Vocabulary (IEV) - Chapter 581: Electro-
IEC 50 (581): 1978,
mechanical components for electronic equipment
1: General and guidance
IEC 68-1: 1988, Environmental testing - Pa rt
Environmental testing - Part 2: Tests - Test Ke: Corrosion tests
IEC 68-2-60 TTD: 1990,
in artificial atmosphere at very low concentration of polluting gas(es)
Low-frequency cables and wires with PVC insulation and PVC sheath -
IEC 189-3: 1988,
Part 3: Equipment wires with solid or stranded conductor, PVC insulated, in singles, pairs
and triples
Amendment 1 (1989)
Printed boards - Part 2: Test methods
IEC 326-2: 1990,
Amendment 1 (1992)
Solderless connections - Part 3: Solderless accessible insulation
IEC 352-3: 1993,
displacement connections - General requirements, tests methods and practical guidance
Electromechanical components for electronic equipment; basic testing
IEC 512-1: 1984,
procedures and measuring methods - Part 1: General
Amendment 1 (1988)
Electromechanical components for electronic equipment; basic testing
IEC 512-2: 1985,
2: General examination, electrical continuity
rt
procedures and measuring methods - Pa
and contact resistance tests, insulation tests and voltage stress tests
Electromechanical components for electronic equipment; basic testing
IEC 512-4: 1976,
4: Dynamic stress tests
procedures and measuring methods - Part
Electromechanical components for electronic equipment; basic testing
IEC 512-5: 1992,
procedures and measuring methods - Part 5: Impact tests (free components), static load
tests(fixed components), endurance tests and overload tests
IEC 512-6: 1984, Electromechanical components for electronic equipment; basic testing
rt 6: Climatic tests and soldering tests
procedures and measuring methods - Pa
IEC 673: 1980, Low-frequency miniature equipment wires with solid or stranded conductor,
fluorinated polyhydrocarbon type insulation, single
Amendment 3 (1989)
PVC insulated ribbon cable with a pitch of 1,27 mm suitable for insulation
IEC 918: 1987,
displacement termination
Metallic and oxide coatings - Measurement of coating thickness - Micro-
ISO 1463: 1982,
scopical method
352-4 © IEC:1994 — 15 —
4 Definitions
of IEC 352 are included in
Terms and definitions used in and applicable to this pa rt
IEC 50(581). IEC 512-1 also contains some applicable terms and definitions.
For the purpose of this part of IEC 352, the following additional terms and definitions
apply.
4.1 Insulation displacement connection (ID connection)
A solderless electrical connection made by inserting a single wire into a precisely
controlled slot in a termination such that the sides of the slot displace the insulation and
deform the conductor of a solid wire or strands of stranded wire to produce a gas-tight
connection.
Ribbon cable with
stranded conductors
IEC 027/93
Figure 2 – Insulation displacement connections
Accessible insulation displacement connection (accessible ID connection)
4.1.1
(See IEC 352-3).
An ID connection in which it is possible to access test points for carrying out mechanical
tests (for example transverse extraction force) and electrical measurements (for example
contact resistance) without deactivation of any design feature intended to establish and/or
maintain the ID connection.
(non-accessible ID connection)
4.1.2 Non-accessible insulation displacement connection
An ID connection in which it is not possible to access test points for carrying out mech-
anical tests such as transverse extraction force and some electrical measurements (for
example contact resistance) without deactivation of any design feature intended to
establish and/or maintain the ID connection, mainly where the ID connection is enclosed in
a component.
4.2 Insulation displacement termination (ID termination)
A termination designed to accept a wire for the purpose of establishing an ID connection.
4.2.1 Reusable insulation displacement termination (reusable ID termination)
An ID termination that can be used more than once.

352-4 ©IEC:1994 - 17 -
4.2.2 Non-reusable insulation displacement termination (non -reusable ID termination)
An ID termination that can only be used once.
4.3 Slot
Strain relief slot or second
connection slot
IEC 028193
Figure 3 - Slot
4.3.1 Connection slot
The specially shaped opening in an ID termination suitable to displace the insulation of a
wire and to ensure a gas-tight connection between the termination and the conductor(s) of
the wire.
In certain cases, a second connection slot is used to provide for a double connectio
...

Questions, Comments and Discussion