EN 112000:1992
(Main)Generic Specification: Image converter and image intensifier tubes
- BACK
- 23-Nov-1992
- 07-Jun-1993
- CLC/SR 110
Generic Specification: Image converter and image intensifier tubes
This document applies to image converter and image intensifier tubes of assessed quality.
Fachgrundspezifikation: Bildwandler- und Bildverstärkerröhren
Spécification générique: Tubes convertisseurs d'image et tubes intensificateurs d'image
Le présent document s'applique aux tubes convertisseurs d'image et tubes intensificateurs d'image de qualité contrôlée.
Generic specification: Image converter and image intensifier tubes
General Information
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Generic specification: Image converter and image intensifier tubesFachgrundspezifikation: Bildwandler- und BildverstärkerröhrenSpécification générique: Tubes convertisseurs d'image et tubes intensificateurs d'imageGeneric Specification: Image converter and image intensifier tubes31.120Elektronske prikazovalne napraveElectronic display devicesICS:Ta slovenski standard je istoveten z:EN 112000:1992SIST EN 112000:2002en01-september-2002SIST EN 112000:2002SLOVENSKI
STAN
...
This May Also Interest You
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for×1 day
- 06-Jun-2024
- 19.040
- CLC/SR 104
This part of EN 62841 applies to reciprocating saws such as jig saws and sabre saws.
- Amendment6 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft4 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-May-2024
- 25.140.20
- 25.140.30
- 2006/42/EC
- M/396
- CLC/TC 116
IEC 62057-3:2024 applies to an automatic meter testing system (AMTS) permanently installed in a controlled environment. It covers the functions, technical requirements and acceptance methods of an AMTS. It also applies to a newly manufactured AMTS to test static active or reactive energy meters on 50 Hz or 60 Hz networks with an AC voltage up to 600 V (phase to neutral). This document defines the kind of AMTS that can continuously and automatically carry out all the test items specified in IEC 62058-31, including visual inspection, AC voltage test, no-load condition, starting current, accuracy and meter constant test. This document does not apply to: • data interfaces to the meter and test procedures of data interface; • industrial controllers, industrial personal computers, and servers supplied along with the AMTS.
- Standard17 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft12 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60793-1-41:2024 is available as IEC 60793-1-41:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60793-1-41:2024 describes three methods for determining and measuring the modal bandwidth of multimode optical fibres (see IEC 60793-2-10, IEC 60793-2-30, and the IEC 60793‑2‑40 series). The baseband frequency response is directly measured in the frequency domain by determining the fibre response to a sinusoidaly modulated light source. The baseband response can also be measured by observing the broadening of a narrow pulse of light. The calculated response is determined using differential mode delay (DMD) data. The three methods are: Method A – Time domain (pulse distortion) measurement Method B – Frequency-domain measurement Method C – Overfilled launch modal bandwidth calculated from differential mode delay (OMBc) Method A and method B can be performed using one of two launches: an overfilled launch (OFL) condition or a restricted mode launch (RML) condition. Method C is only defined for A1-OM3 to A1-OM5 multimode fibres and uses a weighted summation of DMD launch responses with the weights corresponding to an overfilled launch condition. The relevant test method and launch condition is chosen according to the type of fibre. NOTE 1 These test methods are commonly used in production and research facilities and are not easily accomplished in the field. NOTE 2 OFL has been used for the modal bandwidth value for LED-based applications for many years. However, no single launch condition is representative of the laser (e.g. VCSEL) sources that are used for gigabit and higher rate transmission. This fact drove the development of IEC 60793-1-49 for determining the effective modal bandwidth of laser optimized 50 µm fibres. See IEC 60793-2-10 and IEC 61280-4-1 for more information. This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) the addition of a direct reference for method A and method B.
- Standard33 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft28 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-May-2024
- 33.180.10
- CLC/TC 86A
- Amendment18 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft17 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-May-2024
- 33.180.20
- CLC/TC 86BXA
IEC 61757-7-3:2024 defines the terminology, structure, and performance characteristics of fibre optic voltage sensors using a polarimetric measurement method. The document specifies test methods and procedures for measuring key performance parameters of these sensors. It addresses only the voltage sensing element and not the additional devices that are unique to each application. The document does not specify the required performance values of optical polarimetric fibre optic voltage sensors, because these specifications depend on the designated application of the sensor and are typically defined by the user of the sensor. The required performance values are usually defined when designing a sensor for a specific application.
- Standard45 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft46 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-May-2024
- 33.180.99
- CLC/SR 86C
IEC 60793-1-45:2024 is available as IEC 60793-1-45:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60793-1-45:2024 establishes uniform requirements for measuring the mode field diameter (MFD) of single-mode optical fibre, thereby assisting in the inspection of fibres and cables for commercial purposes. This third edition cancels and replaces the second edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) modification of the minimum distance between the fibre end and the detector for the direct far field scan (Annex A). b) generalization of the requirement for the minimum dynamic range for all fibre types (Annex A).
- Standard34 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft30 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-May-2024
- 33.180.10
- CLC/TC 86A
IEC 61753-082-02:2024 contains the minimum initial test, measurement requirements and severities which a fibre optic 1,31/1,55 µm wide wavelength division multiplexing (WWDM) device satisfies in order to be categorised as meeting the requirements of category C (indoor controlled environment), as defined in IEC 61753-1:2018, Annex A. WWDM is defined in IEC 62074-1. This first edition cancels and replaces the first edition of IEC 61753-082-2 published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) change of test conditions harmonizing with IEC 61753-1.
- Standard18 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft13 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-May-2024
- 33.180.10
- CLC/TC 86BXA
IEC 61189-2-808:2024 describes the thermal transient method to characterize the thermal resistance of an assembly consisting of a heat source (e.g. power device), an attachment material (e.g. solder) and a dielectric layer with electrode. This method is suitable to determine the thermal resistance of materials and assembly methods as well as to optimize the thermal flux to a heat sink. NOTE: This method is not intended to measure and specify the value of the thermal resistance of a dielectric material. For that purpose, other standards exist. Examples are given in Annex A.
- Draft18 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 61978-1:2024 is available as IEC 61978-1:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61978-1:2024 applies to fibre optic passive chromatic dispersion compensators, all exhibiting the following features: - they are optically passive; - they have an optical input and an optical output for transmitting optical power; - the ports are optical fibres or optical fibre connectors; - they are wavelength sensitive; - they can be polarization sensitive. This document establishes uniform requirements for the passive chromatic dispersion compensator. This fourth edition cancels and replaces the third edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) harmonization of terms and definitions with IEC TS 62627-09; b) change of Clause 4 regarding requirements.
- Standard28 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft25 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-May-2024
- 33.180.01
- CLC/TC 86BXA
Questions, Comments and Discussion