EN 61000-4-19:2014
(Main)Electromagnetic compatibility (EMC) - Part 4-19: Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports
Electromagnetic compatibility (EMC) - Part 4-19: Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports
IEC 61000-4-19:2014 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, differential mode disturbances and signalling in the range 2 kHz up to 150 kHz at a.c. power ports. The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of differential mode disturbances and signalling to a.c. power ports. This standard defines: - test waveforms; - range of test levels; - test equipment; - test setup; - test procedures; - and verification procedures. These tests are intended to demonstrate the immunity of electrical and electronic equipment operating at a mains supply voltage up to 280 V (from phase to neutral or phase to earth, if no neutral is used) and a frequency of 50 Hz or 60 Hz when subjected to conducted, differential mode disturbances such as those originating from power electronics and power line communication systems. The immunity to harmonics and interharmonics, including mains signalling, on a.c. power ports up to 2 kHz in differential mode is covered by IEC 61000-4-13. Emissions in the frequency range 2 kHz to 150 kHz often have both differential mode and common mode components. This standard provides immunity tests only for differential mode disturbances and signalling. It is recommended to perform common mode tests as well, which are covered by IEC 61000-4-16. Key words: electromagnetic compatibility, EMC
Elektromagnetische Verträglichkeit (EMV) - Teil 4-19: Prüf- und Messverfahren - Prüfung der Störfestigkeit an Wechselstrom-Netzanschlüssen gegen leitungsgeführte symmetrische Störgrößen und Störgrößen aus der Signalübertragung im Frequenzbereich von 2 kHz bis 150 kHz
Compatibilité électromagnétique (CEM) - Partie 4-19: Techniques d'essai et de mesure - Essai pour l'immunité aux perturbations conduites en mode différentiel et à la signalisation dans la gamme de fréquences de 2 kHz à 150 kHz, aux accès de puissance à courant alternatif
L'IEC 61000-4-19:2014 traite des exigences en matière d'immunité et des méthodes d'essai relatives aux matériels électriques et électroniques soumis à des perturbations et des signaux par conduction en mode différentiel dans la bande de fréquences de 2 kHz à 150 kHz, aux accès de puissance à courant alternatif. L'objet de la présente norme est d'établir une base commune et reproductible destinée à soumettre à essai les performances des matériels électriques et électroniques lorsque ceux-ci sont soumis à des perturbations et des signaux par conduction en mode différentiel sur les accès de puissance en courant alternatif. La présente norme définit: - les formes d'onde d'essai; - les plages de niveaux d'essai; - le matériel d'essai; - l'installation d'essai; - les procédures d'essai; - et les procédures de vérification. Ces essais sont destinés à démontrer l'immunité des équipements électriques et électroniques fonctionnant sous une tension d'alimentation du réseau jusqu'à 280 V (phase-neutre ou phase-terre, si le neutre n'est pas utilisé) et une fréquence de 50 Hz ou 60 Hz lorsqu'ils sont soumis à des perturbations conduites en mode différentiel, telles que celles provenant de l'électronique de puissance et des systèmes de communication par courants porteurs en ligne. L'immunité aux harmoniques et interharmoniques, incluant les signaux transmis sur le réseau électrique, sur les accès de puissance jusqu'à 2 kHz en mode différentiel est traitée par l'IEC 61000-4-13. Les émissions dans la gamme de fréquences de 2 kHz à 150 kHz ont souvent des composantes en mode différentiel et en mode commun. La présente norme fournit les essais d'immunité pour les signaux et perturbations en mode différentiel uniquement. Il est recommandé d'effectuer aussi des essais en mode commun, qui sont traités par l'IEC 61000-4-16. Mots clé: compatibilité électromagnétique, CEM, EMC
Elektromagnetna združljivost (EMC) – 4-19. del: Preskušanje in merilne tehnike – Preskus odpornosti proti prevajanim motnjam skupne zvrsti v frekvenčnem območju od 2 kHz do 150 kHz na izmeničnih napajalnih vhodih (IEC 61000-4-19:2014)
Standard EN IEC 61000-4-19 obravnava zahteve po odpornosti proti prevajanim motnjam skupne zvrsti v frekvenčnem območju od 2 kHz do 150 kHz na izmeničnih napajalnih vhodih. Namen tega standarda je oblikovati skupno in ponovljivo podlago za preskušanje električne in elektronske opreme z uporabo motenj in signalov diferenčnega načina na izmeničnih napajalnih vhodih. Ta standard določa: – preskusne valovne oblike, – razpon preskusnih ravni, – preskusno opremo, – preskusne nastavitve, – preskusne postopke, – postopke preverjanja. Ti preskusi so namenjeni prikazu odpornosti električne in elektronske opreme, ki delujeta pri omrežni napetosti napajalnega omrežja do 280 V (faza z nevtralnim ali faza z ozemljenim vodnikom, če nevtralen ni uporabljen) in frekvenci od 50 Hz do 60 Hz, kadar sta izpostavljeni prevajanim motnjam skupne zvrsti, kot so motnje, ki jih proizvajajo močnostna elektronika in sistemi komunikacije prek elektroenergetskih vodov (PLC). Odpornost na harmonike in medharmonike, vključno z napetostnimi signali v omrežju, na vhodih za izmenično napajanje do 2 kHz v diferenčnem načinu, obravnava standard IEC 61000-4-13. Motnje v frekvenčnem razponu od 2 kHz do 150 kHz imajo pogosto sestavne dele diferenčnega in skupnega načina. Ta standard zagotavlja preskuse odpornosti samo za motnje in signale v diferenčnem načinu. Priporoča se izvajanje preskusov skupnega načina, ki jih zajema standard IEC 61000-4-16.
General Information
Overview
EN 61000-4-19:2014 (CLC / IEC 61000-4-19:2014) is an EMC standard that specifies immunity testing and measurement techniques for conducted, differential‑mode disturbances and signalling on a.c. power ports in the frequency range 2 kHz to 150 kHz. It defines a common, reproducible basis for testing electrical and electronic equipment powered from mains supplies up to 280 V (phase‑to‑neutral or phase‑to‑earth) at 50 Hz or 60 Hz, focusing on disturbances originating from power electronics and power‑line communication systems.
Key topics and technical requirements
The standard establishes detailed, testable requirements including:
- Test waveforms - prescribed profiles (e.g., CW pulses with pause, rectangularly modulated pulses) for both differential voltage and differential current tests.
- Range of test levels - frequency‑dependent amplitude tables for 2 kHz–150 kHz to determine immunity levels.
- Test equipment - characteristics and performance requirements for signal generators, coupling/decoupling networks (CDNs) and verification instruments.
- Test setup - recommended wiring, auxiliary equipment connections and laboratory reference conditions to ensure reproducibility.
- Test procedures - step‑by‑step execution, frequency stepping and modulation approaches for applying disturbances to a.c. power ports.
- Verification procedures - methods to verify generator performance and CDN damping characteristics; guidance on evaluating and reporting test results.
- Scope limits - covers differential‑mode only; common‑mode immunity tests are recommended separately (see IEC 61000‑4‑16). Immunity to harmonics/interharmonics up to 2 kHz is covered by IEC 61000‑4‑13.
Applications and practical use
EN 61000‑4‑19 is used to assess and demonstrate the immunity of products to conducted disturbances in the 2 kHz–150 kHz band. Typical applications include:
- Protection of consumer, industrial and utility equipment from interference caused by power electronics (inverters, drives) and power‑line communication (PLC) systems.
- EMC compliance testing of meters, household appliances, industrial controllers, and UPS/power systems whose mains connections can receive differential signalling.
- Development and verification activities in design, production and conformity assessment carried out by EMC engineers, test laboratories, manufacturers, and compliance officers.
Practical benefits: consistent test methodology, repeatable results across labs, and clearer pass/fail criteria for differential conduction immunity.
Related standards
- IEC 61000‑4‑13 - immunity to harmonics and interharmonics (including mains signalling) up to 2 kHz.
- IEC 61000‑4‑16 - immunity tests for conducted common‑mode disturbances 0 Hz–150 kHz.
Keywords: electromagnetic compatibility, EMC, immunity testing, conducted differential mode, a.c. power ports, 2 kHz to 150 kHz, power‑line communication, power electronics.
Standards Content (Sample)
SLOVENSKI STANDARD
01-november-2014
(OHNWURPDJQHWQD]GUXåOMLYRVW(0&±GHO3UHVNXãDQMHLQPHULOQHWHKQLNH±
3UHVNXVRGSRUQRVWLSURWLSUHYDMDQLPPRWQMDPVNXSQH]YUVWLYIUHNYHQþQHP
REPRþMXRGN+]GRN+]QDL]PHQLþQLKQDSDMDOQLKYKRGLK,(&
Electromagnetic compatibility (EMC) -- Part 4-19: Testing and measurement techniques -
Test for immunity to conducted, differential mode disturbances and signalling in the
frequency range 2 kHz to 150 kHz at a.c. power ports
Compatibilité Électromagnétique (CEM) - Partie 4-19: Techniques d'essai et de mesure -
Essai pour l'immunité aux perturbations conduites en mode différentiel et à la
signalisation dans la bande de fréquence de 2 kHz à 150 kHz, aux entrée de puissance
à courant alternatif
Ta slovenski standard je istoveten z: EN 61000-4-19:2014
ICS:
33.100.20 Imunost Immunity
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN 61000-4-19
NORME EUROPÉENNE
EUROPÄISCHE NORM
August 2014
ICS 33.100.20
English Version
Electromagnetic compatibility (EMC) - Part 4-19: Testing and
measurement techniques - Test for immunity to conducted,
differential mode disturbances and signalling in the frequency
range 2 kHz to 150 kHz at a.c. power ports
(IEC 61000-4-19:2014)
Compatibilité électromagnétique (CEM) - Partie 4-19: Elektromagnetische Verträglichkeit (EMV) - Teil 4-19: Prüf-
Techniques d'essai et de mesure - Essai pour l'immunité und Messverfahren - Prüfung der Störfestigkeit an
aux perturbations conduites en mode différentiel et à la Wechselstrom-Netzanschlüssen gegen leitungsgeführte
signalisation dans la gamme de fréquences de 2 kHz à symmetrische Störgrößen und Störgrößen aus der
150 kHz, aux accès de puissance à courant alternatif Signalübertragung im Frequenzbereich von 2 kHz bis
(CEI 61000-4-19:2014) 150 kHz
(IEC 61000-4-19:2014)
This European Standard was approved by CENELEC on 2014-06-11. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 61000-4-19:2014 E
Foreword
The text of document 77A/845/FDIS, future edition 1 of IEC 61000-4-19, prepared by SC 77A "EMC –
Low frequency phenomena", of IEC/TC 77 "Electromagnetic compatibility" was submitted to the IEC-
CENELEC parallel vote and approved by CENELEC as EN 61000-4-19:2014.
The following dates are fixed:
– latest date by which the document has to be implemented at (dop) 2015-03-11
national level by publication of an identical national
standard or by endorsement
– latest date by which the national standards conflicting with (dow) 2017-06-11
the document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 61000-4-19:2014 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60068-1 NOTE Harmonized as EN 60068-1.
IEC 61000-2-2:2002 NOTE Harmonized as EN 61000-2-2:2002 (not modified).
IEC 61000-2-12:2003 NOTE Harmonized as EN 61000-2-12:2003 (not modified).
CISPR 14-1:2005 NOTE Harmonized as EN 55014-1:2006 (not modified)
+ A1:2008 + A1:2009 (not modified)
+ A2:2011 + A2:2011 (not modified).
CISPR 15:2013 NOTE Harmonized as EN 55015:2013 (not modified).
- 3 - EN 61000-4-19:2014
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is
available here: www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 61000-4-13 2002 Electromagnetic compatibility (EMC) - EN 61000-4-13 2002
+ A1 2009 Part 4-13: Testing and measurement + A1 2009
techniques - Harmonics and interharmonics
including mains signalling at a.c. power
port, low frequency immunity tests
IEC 61000-4-16 1998 Electromagnetic compatibility (EMC) - EN 61000-4-16 1998
+ A1 2001 Part 4-16: Testing and measurement + A1 2004
+ A2 2009 techniques - Test for immunity to + A2 2011
conducted, common mode disturbances in
the frequency range 0 Hz to 150 kHz
IEC 61000-4-19 ®
Edition 1.0 2014-05
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
BASIC EMC PUBLICATION
PUBLICATION FONDAMENTALE EN CEM
Electromagnetic compatibility (EMC) –
Part 4-19: Testing and measurement techniques – Test for immunity to
conducted, differential mode disturbances and signalling in the frequency range
2 kHz to 150 kHz at a.c. power ports
Compatibilité électromagnétique (CEM) –
Partie 4-19: Techniques d’essai et de mesure – Essai pour l'immunité aux
perturbations conduites en mode différentiel et à la signalisation dans la gamme
de fréquences de 2 kHz à 150 kHz, aux accès de puissance à courant alternatif
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX V
ICS 33.100.20 ISBN 978-2-8322-1565-4
– 2 – IEC 61000-4-19:2014 © IEC 2014
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 8
3.1 Terms and definitions. 8
3.2 Abbreviations . 9
4 General . 9
5 Test levels and wave profiles in the frequency range 2 kHz to 150 kHz . 10
5.1 Test levels for differential voltage testing . 10
5.1.1 General . 10
5.1.2 Test wave profile with CW pulses with pause . 11
5.1.3 Test wave profile with rectangularly modulated pulses . 12
5.2 Test levels for differential current testing . 12
5.2.1 General . 12
5.2.2 Test wave profile with CW pulses with pause . 13
5.2.3 Test wave profile with rectangularly modulated pulses . 13
6 Test equipment . 13
6.1 Test generators . 13
6.1.1 General . 13
6.1.2 Characteristics and performance of the generator for the differential
voltage test . 14
6.1.3 Characteristics and performance of the generator for the differential
current test . 14
6.2 Verification of the characteristics of the test generators . 15
6.2.1 General . 15
6.2.2 Verification of the generators . 15
6.2.3 Verification of the coupling/decoupling network . 16
7 Test setups . 17
7.1 Test setup for differential mode voltage testing . 17
7.2 Test setup for differential mode current test . 18
8 Test procedure . 18
8.1 General . 18
8.2 Laboratory reference conditions . 19
8.2.1 Climatic conditions . 19
8.2.2 Electromagnetic conditions . 19
8.3 Execution of the test . 19
9 Evaluation of test results . 19
10 Test report . 20
Annex A (informative) Interference sources, victims and effects . 21
Annex B (informative) Selection of test levels . 25
Annex C (informative) Testing electricity meters guideline . 27
C.1 Example of the basic structure of a test generator for differential current
testing. 27
C.2 Example of a test circuit . 28
IEC 61000-4-19:2014 © IEC 2014 – 3 –
C.3 Example of a realized setup including schematics . 29
Annex D (informative) Test wave profiles . 30
Bibliography . 31
Figure 1 – Frequency vs. amplitude profile for differential voltage testing . 11
Figure 2 – Test wave profile with CW pulses with pause . 12
Figure 3 – Test wave profile with rectangularly modulated pulses for differential
voltage testing . 12
Figure 4 – Example of a simplified circuit diagram with the major elements of the
differential voltage test generator . 14
Figure 5 – Test setup for verification of the CDN in a 10 Ω measurement system. 16
Figure 6 – Limit for the damping characteristics measured in a 10 Ω measurement
system . 17
Figure 7 – Example of test setup for differential mode voltage testing with auxiliary
equipment . 17
Figure 8 – Example of test setup for differential mode current testing . 18
Figure A.1 – Standards dealing with voltage levels due to non-intentional emissions in
the frequency range 2 kHz to 150 kHz . 23
Figure A.2 – Standards dealing with voltage levels due to intentional emissions in the
frequency range 2 kHz to 150 kHz . 24
Figure C.1 – Simplified circuit of a differential current test generator . 27
Figure C.2 – Example of a test circuit . 28
Figure C.3 – Example for a realized test set up . 29
Table 1 – Test levels in the 2 kHz to 150 kHz frequency range for differential voltage
testing . 10
Table 2 – Test levels in the 2 kHz to 150 kHz frequency range for differential current
testing . 13
– 4 – IEC 61000-4-19:2014 © IEC 2014
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
ELECTROMAGNETIC COMPATIBILITY (EMC) –
Part 4-19: Testing and measurement techniques – Test for immunity
to conducted, differential mode disturbances and signalling in the
frequency range 2 kHz to 150 kHz at a.c. power ports
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61000-4-19 has been prepared by subcommittee 77A: EMC – Low
frequency phenomena, of IEC technical committee 77: Electromagnetic compatibility.
It forms Part 4-19 of IEC 61000. It has the status of a basic EMC publication in accordance
with IEC Guide 107.
IEC 61000-4-19:2014 © IEC 2014 – 5 –
The text of this standard is based on the following documents:
FDIS Report on voting
77A/845/FDIS 77A/854/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts in the IEC 61000 series, published under the general title Electromagnetic
compatibility (EMC), can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
– 6 – IEC 61000-4-19:2014 © IEC 2014
INTRODUCTION
IEC 61000 is published in separate parts, according to the following structure:
Part 1: General
General considerations (introduction, fundamental principles)
Definitions, terminology
Part 2: Environment
Description of the environment
Classification of the environment
Compatibility levels
Part 3: Limits
Emission limits
Immunity limits (in so far as they do not fall under the responsibility of the product
committees)
Part 4: Testing and measurement techniques
Measurement techniques
Testing techniques
Part 5: Installation and mitigation guidelines
Installation guidelines
Mitigation methods and devices
Part 6: Generic standards
Part 9: Miscellaneous
Each part is further subdivided into several parts, published either as international standards
or as technical specifications or technical reports, some of which have already been published
as sections. Others are published with the part number followed by a dash and a second
number identifying the subdivision (example: IEC 61000-6-1).
IEC 61000-4-19:2014 © IEC 2014 – 7 –
ELECTROMAGNETIC COMPATIBILITY (EMC) –
Part 4-19: Testing and measurement techniques – Test for immunity
to conducted, differential mode disturbances and signalling in the
frequency range 2 kHz to 150 kHz at a.c. power ports
1 Scope
This part of IEC 61000 relates to the immunity requirements and test methods for electrical
and electronic equipment to conducted, differential mode disturbances and signalling in the
range 2 kHz up to 150 kHz at a.c. power ports.
The object of this standard is to establish a common and reproducible basis for testing
electrical and electronic equipment with the application of differential mode disturbances and
signalling to a.c. power ports. This standard defines:
– test waveforms;
– range of test levels;
– test equipment;
– test setup;
– test procedures;
– verification procedures.
These tests are intended to demonstrate the immunity of electrical and electronic equipment
operating at a mains supply voltage up to 280 V (from phase to neutral or phase to earth, if no
neutral is used) and a frequency of 50 Hz or 60 Hz when subjected to conducted, differential
mode disturbances such as those originating from power electronics and power line
communication systems (PLC).
NOTE In some countries, the maximum voltage can be as much as 350 V from phase to neutral.
The immunity to harmonics and interharmonics, including mains signalling, on a.c. power
ports up to 2 kHz in differential mode is covered by IEC 61000-4-13.
Emissions in the frequency range 2 kHz to 150 kHz often have both differential mode and
common mode components. This standard provides immunity tests only for differential mode
disturbances and signalling. It is recommended to perform common mode tests as well, which
are covered by IEC 61000-4-16.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 61000-4-13:2002, Electromagnetic compatibility (EMC) – Part 4-13: Testing and
measurement techniques – Harmonics and interharmonics including mains signalling at a.c.
power port, low frequency immunity tests
Amendment 1:2009
IEC 61000-4-16:1998, Electromagnetic compatibility (EMC) – Part 4-16: Testing and
measurement techniques – Test for immunity to conducted, common mode disturbances in
– 8 – IEC 61000-4-19:2014 © IEC 2014
the frequency range 0 Hz to 150 kHz
Amendment 1:2001
Amendment 2:2009
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
NOTE The terms apply to the restricted field of conducted, differential mode disturbances and signalling in the
range of 2 kHz up to 150 kHz (not all of these definitions are included in IEC 60050-161).
3.1 Terms and definitions
3.1.1
auxiliary equipment
AE
equipment that is necessary for setting up all functions and assessing the correct
performance (operation) of the EUT (equipment under test) during the test
3.1.2
port
particular interface of the specified equipment with the external electromagnetic environment
3.1.3
a.c. power port
port of connection to power supply networks
3.1.4
coupling
interaction between circuits, transferring energy from one circuit to another
3.1.5
coupling network
electrical circuit for the purpose of transferring energy from one circuit to another
3.1.6
immunity (to a disturbance)
ability of a device, equipment or system to perform without degradation in the presence of an
electromagnetic disturbance
[SOURCE: IEC 60050-161:1990, 161-01-20]
3.1.7
differential mode voltage
symmetrical voltage
voltage between any two of a specified set of active conductors
[SOURCE: IEC 60050-161:1990, 161-04-08]
3.1.8
differential mode current
I
Diff
in a two-conductor cable, or for two particular conductors in a multi-conductor cable, half the
magnitude of the difference of the phasors representing the currents in each conductor
[SOURCE: IEC 60050-161:1990, 161-04-38]
IEC 61000-4-19:2014 © IEC 2014 – 9 –
3.1.9
load current
I
Load
for the EUT which has a dedicated a.c. current measurement port, this is the current at power
frequency flowing through the current path of the EUT, e.g. in an electricity meter, typically
the load current I is flowing through the live wires L to L of the meter
Load IN OUT
3.2 Abbreviations
BB Broadband
CDN Coupling/decoupling network
CW Continuous wave
EUT Equipment under test
LV Low voltage
MV Medium voltage
NB Narrowband
PLC Power line communications
4 General
Conducted, differential mode disturbances and signalling in the frequency range 2 kHz up to
150 kHz may influence the performance of equipment and systems installed in all
electromagnetic environments. Therefore in this frequency range, differential mode
disturbances and signalling are to be taken into account.
As coupling of these disturbances and signalling could be very strong for a.c. power ports but
is only relatively weak for all the other ports, the requirements of this standard apply to a.c.
power ports only.
The disturbances and signalling are typically generated by:
– power line communication systems;
– power electronic equipment (e.g. power converters, lighting).
Annex A contains information on the interference sources, victims and effects.
Annex D provides the rationale for the test wave profiles and some recommendations for the
choice of the tests.
Adequate immunity to these differential mode disturbances and signalling is necessary. To
verify such immunity, two tests for voltage and current are defined in this standard, both in the
frequency range from 2 kHz to 150 kHz:
– a sweep test performed with CW (continuous wave) pulses with pauses between each
pulse;
– a test performed with blocks of rectangularly modulated pulses with four different
modulation frequencies.
Typically, voltage tests apply to all equipment, while current tests are intended for equipment
with an a.c. current measurement port, such as an electricity meter.
Product committees are free to choose between voltage and current tests, test levels, type of
modulation and modulation frequencies.
Nevertheless, it is recommended to perform immunity tests including at least a sweep test
performed with CW pulses with pause and another test with rectangularly modulated pulses
– 10 – IEC 61000-4-19:2014 © IEC 2014
with modulation frequencies of 3 Hz and 101 Hz for power frequency at 50 Hz (or 4 Hz and
121 Hz at 60 Hz) which reflect the interference due to inverters and mains communication
systems.
NOTE Test levels proposed in Clause 5 may be revised in the future in order to take into account work underway
on compatibility levels (IEC 61000-2-2 and IEC 61000-2-12).
5 Test levels and wave profiles in the frequency range 2 kHz to 150 kHz
5.1 Test levels for differential voltage testing
5.1.1 General
Test levels for differential voltage testing to a.c. power ports in the frequency range from
2 kHz up to 150 kHz are given in Table 1.
A guide for the selection of the test level is given in Annex B.
The level in column 1 of Table 1 makes reference to the environment class (Class 1, Class 2,
etc.) defined in Annex B. Table 1 gives the preferred values of test voltage levels for
equipment used in the corresponding environment class.
Table 1 – Test levels in the 2 kHz to 150 kHz
frequency range for differential voltage testing
Open circuit unmodulated test voltage
V (r.m.s.)
Level
2 kHz to 9 kHz 9 kHz to 95 kHz 95 kHz to 150 kHz
1 0,5 0,5 to 0,1 0,1
2 3 3 to 0,6 0,6
3 12 12 to 2,4 2,4
4 20 20 to 10 10
a
X Special Special Special
a
"X" can be any level, above, below or in between the others. The level shall be specified by the product
standard.
As shown in Figure 1, where the profile for each of the open circuit test voltage defined in
Table 1 in relation to the frequency is given, the test voltage varies with frequency as follows:
• the level is constant from 2 kHz to 9 kHz;
• the logarithm of the level decreases linearly with the logarithm of the frequency from 9 kHz
to 95 kHz;
• the level is constant from 95 kHz to 150 kHz.
IEC 61000-4-19:2014 © IEC 2014 – 11 –
Level 4
Level 3
Level 2
Level 1
0,1
1 10 100
Frequency (kHz)
IEC 1447/14
Figure 1 – Frequency vs. amplitude profile for differential voltage testing
On the basis of investigations currently available (see Annex A), differential mode tests with
two types of modulation are required: one with CW pulses with pauses between each pulse
(5.1.2, respectively 5.2.2), and another with blocks of rectangularly modulated pulses (5.1.3,
respectively 5.2.3 ).
5.1.2 Test wave profile with CW pulses with pause
The test is carried out by applying a sequence of pulses of a sinusoidal signal (CW) with an
increasing frequency f ranging from 2 kHz to 150 kHz and pauses of a defined duration as
i
follows (see also Figure 2):
• Each CW pulse has a duration (dwell time) of T .
pulse
• Between each CW pulse the level of the test signal (voltage or current) is zero for a period
of T = 300 ms with a tolerance of ± 200 ms.
pause
• The dwell time T shall not be less than the time necessary for the EUT to be exercized
pulse
and to respond, but shall not be less than 3 s. Product committees may consider requiring
longer dwell times.
• The duration of one test cycle for a specific CW test frequency is T + T
.
pulse pause
• The start frequency of the CW test signal shall be 2 kHz and the frequency of the
successive CW test signals shall be increased by 2 % with respect to the previous test
frequency: f = 1,02 f
.
i i-1
• The turn-off times at the end of a CW pulse (start of the pause) and the turn-on times at
the beginning of a CW pulse (end of the pause) of the test voltages (at frequencies f , f ,
i i+1
….) need not be synchronized with the zero crossings of the CW test signal.
Voltage rms (V)
– 12 – IEC 61000-4-19:2014 © IEC 2014
f f = f x 1,02
i i+1 i
t
T
T
pulse
pulse
T T
pause
pause
IEC 1448/14
Figure 2 – Test wave profile with CW pulses with pause
5.1.3 Test wave profile with rectangularly modulated pulses
The test is performed by applying a sequence of pulses with an increasing frequency ranging
from 2 kHz to 150 kHz that is pulse-modulated with four different modulation frequencies with
a duty cycle of 50 % as follows (see also Figure 3):
• The sequence of pulses at frequency f for a chosen modulation frequency has a duration
i
(dwell time) of T = 3 s.
dwell
• The start frequency of the pulses shall be 2 kHz and the frequency of the successive
sequence of pulses shall be increased by 2 % with respect to the previous frequency: f =
i
. Between two dwell times there is a pause of 300 ms with a tolerance of ± 200 ms.
1,02 f
i-1
For the four specified tests with rectangularly modulated pulses, the modulation
frequencies f depend on the applicable mains power frequency as follows:
mod
50 Hz: 3 Hz; 101 Hz; 301 Hz; 601 Hz,
60 Hz: 4 Hz; 121 Hz; 361 Hz; 721 Hz.
• The modulation period T for a certain modulation frequency f has the following
mod mod
relation: T =1/ f
mod mod
• The turn-off times at the end of a pulse and the turn-on times at the beginning of a pulse
need not be synchronized with the zero crossings of the pulses.
f f = f x 1,02
i i+1 i
t
T
mod
T T T
dwell pause dwell
IEC 1449/14
Figure 3 – Test wave profile with rectangularly modulated pulses
for differential voltage testing
5.2 Test levels for differential current testing
5.2.1 General
Table 2 shows the test levels in the 2 kHz to 150 kHz frequency range for differential current
testing.
IEC 61000-4-19:2014 © IEC 2014 – 13 –
A guide for the selection of the test level is given in Annex B.
The level in column 1 of Table 2 makes reference to the class environment (Class 1, Class 2,
etc.) defined in Annex B. Table 2 gives the preferred values of test current levels for
equipment used in the corresponding class environment.
Table 2 – Test levels in the 2 kHz to 150 kHz
frequency range for differential current testing
Unmodulated current in A (r.m.s.)
Level
2 kHz to 30 kHz 30 kHz to 150 kHz
1 1
0,5
2 2 1
3 3 1,5
4 4 2
a
X
Special Special
At the transition frequency, the higher level applies.
a
"X" can be any level, above, below or in between the others. The level shall be specified by the product
standard.
Two types of differential current test modulation are defined, one with CW pulses with pauses
between each pulse (5.2.2), and another with blocks of rectangularly modulated pulses (5.2.3).
Product committees shall define if only one or both modulation types shall be applied.
5.2.2 Test wave profile with CW pulses with pause
The same test wave profile as defined for differential voltage testing in 5.1.2 is applicable.
Product committees may define frequency step sizes smaller than specified in 5.1.2. As an
example, this test profile is applied for electricity meters.
5.2.3 Test wave profile with rectangularly modulated pulses
The same test wave profile as defined for differential voltage testing in 5.1.3 is applicable.
Product committees may define frequency step sizes smaller than specified in 5.1.3.
6 Test equipment
6.1 Test generators
6.1.1 General
The features of the test generator for differential voltage testing are given in 6.1.2. The
features of the test generator for differential current testing are given in 6.1.3.
All the generators shall have provisions to prevent emissions which, if injected in the power
supply network, may influence the test results.
A single electronic a.c. power source for both the differential voltage test and for the
differential current test can be used as test generator. For the differential test voltage
generator, the values of C and L included in Figure 4 are determined by the performance
requirements.
– 14 – IEC 61000-4-19:2014 © IEC 2014
6.1.2 Characteristics and performance of the generator for the differential voltage
test
The differential voltage test generator typically consists of a waveform generator capable of
covering the frequency band of interest and to provide CW pulses as shown in Figure 2 and
modulated pulses as shown in Figure 3.
Differential mode voltage generator:
– waveform: sinusoidal, total harmonic distortion less
than 5 % for all the frequencies in the
range;
– open circuit output voltage range (r.m.s.): 0,1 V (–10 %) to 20 V (+10 %);
– impedance at EUT connection terminals: 10 Ω; ± 30 % across the range 2 kHz to
150 kHz;
– frequency range: 2 kHz to 150 kHz;
– on/off switching of the output voltage: no synchronization to mains of power
source;
– tolerance of differential voltage test level: ± 5 %.
These parameters shall be verified on the EUT port of the coupling network with a short circuit
on the mains port.
An example of the schematic in principle of the differential mode test generator is given in
Figure 4.
L
C
L1 d
Components:
Mains or
Generator: 2 – 150 kHz
power source
L
C = Coupling capacitor
c
N C = Decoupling capacitor
d
L = Decoupling inductance
CDN = Coupling/Decoupling network
PE CDN
C
c
L1'
EUT
N'
Generator
PE
IEC 1450/14
Figure 4 – Example of a simplified circuit diagram with
the major elements of the differential voltage test generator
6.1.3 Characteristics and performance of the generator for the differential current
test
The differential current test generator typically consists of a waveform generator capable of
covering the frequency band of interest and to provide CW pulses as shown in Figure 2 and
modulated pulses as shown in Figure 3.
– waveform: sinusoidal, total harmonic distortion less
than 5 % for all the frequencies in the
range;
– short circuit output current range (r.m.s.): 0,5 A (–10 %) to 4 A (+10 %), see Note;
IEC 61000-4-19:2014 © IEC 2014 – 15 –
– impedance: 1 Ω; ± 30 % across the range 2 kHz to
150 kHz;
– frequency range: 2 kHz to 150 kHz;
– on/off switching of the output current: no synchronization to mains of power
source;
– tolerance of differential current test level ± 5 %.
NOTE A value of 0,01 A instead of 0,5 A of short circuit output current can be necessary for testing transformer
connected electricity meters.
These parameters shall be verified on the EUT port of the test configuration. The value 1 Ω of
the impedance is obtained from the open circuit voltage divided by the short circuit output
current measured at the same frequency.
More detailed information for testing particular equipment such as electricity meters is
included in Annex C.
6.2 Verification of the characteristics of the test generators
6.2.1 General
In order to make it possible to compare the results dealing with different test generators, they
shall be calibrated or verified for the most essential characteristics.
The following generator characteristics shall be verified:
– output voltage waveform in open circuit,
– output current waveform in short circuit,
– output voltage/current accuracy,
– generator impedance,
– frequency accuracy.
6.2.2 Verification of the generators
The verification of the generators shall be carried out in open circuit for the differential voltage
generator with a differential probe of minimum 1 MΩ and in short circuit for the differential
current generator with a shunt of maximum 0,01 Ω using an oscilloscope or other equivalent
measurement instrumentation with 10 MHz minimum bandwidth.
The accuracy shall be sufficient to comply with voltage, current and impedance requirements.
For the correct setting of the generator and modulated pulse test level, the procedures given
in 5.1.2 and 5.1.3 shall be applied.
The generator for voltage testing shall comply with 6.1.2 and test levels of Table 1 in 5.1.1.
The generator for current testing shall comply with 6.1.3 and test levels of Table 2 in 5.2.1.
The coupling/decoupling network (CDN) shall comply with the requirements of 6.2.3.
For differential voltage verification, the open circuit voltage at the EUT port of the CDN shall
be measured with the voltage differential probe.
For differential current verification, the short circuit current at the EUT port shall be measured
using the shunt.
– 16 – IEC 61000-4-19:2014 © IEC 2014
The impedance shall be verified measuring the values of the open circuit voltage divided by
the short circuit output current at 2 kHz and 150 kHz.
6.2.3 Verification of the coupling/decoupling network
The damping characteristics (mains to EUT) of the CDN shown in Figure 4 shall be verified in
a 10 Ω measurement system using impedance matching baluns and a network analyser. The
generator port should be terminated by 10 Ω or by the generator having 10 Ω output
impedance. Figure 5 shows the basic principle of the test setup.
NETWORK ANALYSER
Balun
50 Ω/10 Ω
Mains port
Balun
10 Ω/50 Ω
CDN
IEC 1451/14
Figure 5 – Test setup for verification of the CDN in a 10 Ω measurement system
The limit for the minimum damping of the coupling network and a measurement example are
shown in Figure 6. The limit decreases linearly with the log of the frequency from 10 dB at
2 kHz to 50 dB at 50 kHz and remains constant at 50 dB from 50 kHz to 150 kHz.
10 Ω
Generator port
EUT port
IEC 61000-4-19:2014 © IEC 2014 – 17 –
dB
Decoupling attenuation (EUT – mains)
f (kHz)
Measurement example Limit
IEC 1452/14
Figure 6 – Limit for the damping characteristics
measured in a 10 Ω measurement system
7 Test setups
7.1 Test setup for differential mode voltage testing
A test setup for the differential voltage test defined in 5.1.2 and 5.1.3 is shown in Figure 7.
L
C
L1 d
Mains or
power source
auxiliary
L
equipment AE
N
PE
CDN
C
c
L1'
EUT
N' with
auxiliary
Generator
equipment AE
PE
IEC 1453/14
Figure 7 – Example of test setup for differential mode
voltage testing with auxiliary equipment
The EUT shall be connected to the earthing system in accordance with the manufacturer's
specifications. The equipment under test shall be arranged and connected according to the
equipment installation specifications.
The operating signals for exercising the EUT may be provided by the AE or simulator, e.g. a
PLC modem.
The cables specified by the equipment manufacturer shall be used; in the absence of
specifications, unshielded cables shall be adopted, of the type suitable for the signals
involved.
– 18 – IEC 61000-4-19:2014 © IEC 2014
7.2 Test setup for differential mode current test
The differential current test setup, shown in Figure 8, is used with EUTs such as e.g.
electricity meters having an a.c. current measurement port. One current is the load current
I at power frequency and the second i
...
Frequently Asked Questions
EN 61000-4-19:2014 is a standard published by CLC. Its full title is "Electromagnetic compatibility (EMC) - Part 4-19: Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports". This standard covers: IEC 61000-4-19:2014 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, differential mode disturbances and signalling in the range 2 kHz up to 150 kHz at a.c. power ports. The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of differential mode disturbances and signalling to a.c. power ports. This standard defines: - test waveforms; - range of test levels; - test equipment; - test setup; - test procedures; - and verification procedures. These tests are intended to demonstrate the immunity of electrical and electronic equipment operating at a mains supply voltage up to 280 V (from phase to neutral or phase to earth, if no neutral is used) and a frequency of 50 Hz or 60 Hz when subjected to conducted, differential mode disturbances such as those originating from power electronics and power line communication systems. The immunity to harmonics and interharmonics, including mains signalling, on a.c. power ports up to 2 kHz in differential mode is covered by IEC 61000-4-13. Emissions in the frequency range 2 kHz to 150 kHz often have both differential mode and common mode components. This standard provides immunity tests only for differential mode disturbances and signalling. It is recommended to perform common mode tests as well, which are covered by IEC 61000-4-16. Key words: electromagnetic compatibility, EMC
IEC 61000-4-19:2014 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, differential mode disturbances and signalling in the range 2 kHz up to 150 kHz at a.c. power ports. The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of differential mode disturbances and signalling to a.c. power ports. This standard defines: - test waveforms; - range of test levels; - test equipment; - test setup; - test procedures; - and verification procedures. These tests are intended to demonstrate the immunity of electrical and electronic equipment operating at a mains supply voltage up to 280 V (from phase to neutral or phase to earth, if no neutral is used) and a frequency of 50 Hz or 60 Hz when subjected to conducted, differential mode disturbances such as those originating from power electronics and power line communication systems. The immunity to harmonics and interharmonics, including mains signalling, on a.c. power ports up to 2 kHz in differential mode is covered by IEC 61000-4-13. Emissions in the frequency range 2 kHz to 150 kHz often have both differential mode and common mode components. This standard provides immunity tests only for differential mode disturbances and signalling. It is recommended to perform common mode tests as well, which are covered by IEC 61000-4-16. Key words: electromagnetic compatibility, EMC
EN 61000-4-19:2014 is classified under the following ICS (International Classification for Standards) categories: 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 61000-4-19:2014 is associated with the following European legislation: EU Directives/Regulations: 2004/108/EC, 2004/108/EU, 2014/30/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
You can purchase EN 61000-4-19:2014 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.
記事のタイトル:EN 61000-4-19:2014 - 電磁両立性(EMC)- 部分4-19:試験および測定技術- 直流電力ポートの2 kHzから150 kHzの周波数範囲での導入された差動モードの変動および信号への耐性試験 記事の内容:IEC 61000-4-19:2014は、直流電力ポートでの2 kHzから150 kHzの周波数範囲での導入された差動モードの変動および信号に対する電気および電子機器の耐性要件と試験方法に関連しています。この規格の目的は、差動モードの変動および信号を直流電力ポートに適用して電気および電子機器を試験するための共通かつ再現可能な基準を確立することです。この規格では次のものを定義しています:- 試験波形- 試験レベルの範囲- 試験機器- 試験設定- 試験手順- および検証手順。これらの試験は、直流電力エレクトロニクスや電力通信システムから発生するものなど、メイン供給電圧で動作する電気および電子機器の耐性を実証するために行われます(中性または地へ)および周波数50 Hzまたは60 Hz。 IEC 61000-4-13では、2 kHzまでの差動モードで動作する直流電力ポートの高調波および誘導モード、および直流電力ポートの信号に対する耐性が取り上げられています。周波数範囲2 kHz〜150 kHzの放射は、差動モードおよび共通モードの両成分を持つことがよくあります。この規格は差動モードの変動および信号に対する耐性試験情報のみを提供します。したがって、別途IEC 61000-4-16で取り上げられる共通モードテストも実施することが推奨されます。主要なキーワード:電磁両立性、EMC
The article discusses the EN 61000-4-19:2014 standard, which focuses on the immunity requirements and test methods for electrical and electronic equipment to conducted, differential mode disturbances and signalling in the frequency range of 2 kHz to 150 kHz at a.c. power ports. The standard aims to establish a common and reproducible basis for testing equipment in terms of their immunity to these disturbances. It defines various aspects such as test waveforms, test levels, test equipment, test setup, test procedures, and verification procedures. These tests are designed to demonstrate the immunity of equipment operating at a mains supply voltage of up to 280 V and a frequency of 50 Hz or 60 Hz when subjected to differential mode disturbances originating from power electronics and power line communication systems. The standard only covers differential mode disturbances and signalling, while common mode tests are recommended to be performed separately.
기사 제목: EN 61000-4-19:2014 - 전자기적 호환성 (EMC) - 파트 4-19: 시험 및 측정 기술 - 교류 전원 포트에서 2 kHz에서 150 kHz 주파수 범위의 전도형 차동 모드 간섭 및 신호에 대한 견뢰성 시험 기사 내용: IEC 61000-4-19:2014은 교류 전원 포트에서 2 kHz에서 150 kHz 주파수 범위의 전도형 차동 모드 간섭 및 신호에 대한 전기 및 전자 장비의 견뢰성 요구 사항과 시험 방법에 관련된 것입니다. 이 표준의 목적은 교류 전원 포트에 차동 모드 간섭 및 신호를 가하여 전기 및 전자 장비를 테스트하는 일반적이고 재현 가능한 기준을 수립하는 것입니다. 이 표준은 다음을 정의합니다: - 시험 파형; - 시험 수준의 범위; - 시험 장비; - 시험 설치; - 시험 절차; - 및 확인 절차. 이러한 시험은 전압이 280 V 이하 (상과 중성 또는 중성이 없는 경우 상과 땅 사이에서)이며 50 Hz 또는 60 Hz 주파수에서 작동하는 전기 및 전자 장비의 견뢰성을 증명하기 위해 전력 전자학 및 전력 통신 시스템에서 유래한 차동 모드 간섭과 같은 간섭에 노출될 때 사용됩니다. IEC 61000-4-13에서는 2 kHz까지의 주파수 범위에서 차동 모드로 작동하는 교류 전원 포트의 고조파 및 교조파, 포함하여 교류 전원 포트의 신호에 대한 견뢰성이 다루어집니다. 2 kHz에서 150 kHz 주파수 범위의 방출은 보편 모드 및 차동 모드 성분을 모두 가지고 있을 수 있습니다. 이 표준은 차동 모드 간섭과 신호에 대한 견뢰성 시험 정보만을 제공합니다. 따라서 별도로 국제 전기 표준회 (IEC) 61000-4-16에서 다루는 보편 모드 시험을 수행하는 것이 권장됩니다. 주요 키워드: 전자기적 호환성, EMC








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...