EN 62612:2013/A11:2017
(Amendment)Self-ballasted LED lamps for general lighting services with supply voltages > 50 V - Performance requirements
Self-ballasted LED lamps for general lighting services with supply voltages > 50 V - Performance requirements
IEC 62612:2013 specifies the performance requirements, together with the test methods and conditions, required to show compliance of LED lamps with integral means for stable operation, intended for domestic and similar general lighting purposes, having: - a rated power up to 60 W; - a rated voltage of > 50 V a.c. up to 250 V a.c.; - a lamp cap as listed in IEC 62560. This first edition of IEC 62612 cancels and replaces IEC/PAS 62612. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC/PAS 62612. a) The standard explicitly states that real life time tests are not part of the test regime. Instead, a period of up to 6 000 h is chosen in order to assess manufacturers' claims of maintenance. b) Technical features have been adapted to IEC/PAS 62717 (performance of LED modules) as far as possible. Examples are the family approach and the temperature measuring point. c) Marking requirements are shifted from the product to the packaging. d) The number of lamps to be tested is made test specific, not general. e) First requirements are given for setting the colour for colour adjustable lamps and the luminous flux level of dimmable lamps. f) The structure of tests is clearly divided between requirement and compliance. g) Statistical compliance is separated into individual and average. h) Light output requirements are extended to luminous intensity distribution, peak intensity, beam angle and efficacy. i) The use of the terms 'correlated colour temperature' and 'chromaticity coordinates' is corrected. j) The number of tolerance categories is reduced from 8 to 4, and split between initial and maintained values. k) Colour rendering is differently assessed at initial and maintained state. l) Three lumen maintenance categories are given instead of five. m) The endurance tests are completely re-established. n) The verification (formerly: assessment) clause is completed. o) Information for luminaire design is added. p) Stabilisation is more precise (Annex A on the method of measuring lamp characteristics) and extension is made for the additional photometric and colorimetric parameters. q) Annex B on measuring luminous flux is contained in Annex A. New Annex B provides the photometric code. r) Further annexes are added: Annex C and D for displacement factor, Annex E for life time metrics/reliability and Annex F for examples of LED dies and LED packages.
LED-Lampen mit eingebautem Vorschaltgerät für Allgemeinbeleuchtung mit Versorgungsspannungen > 50 V - Anforderungen an die Arbeitsweise
Lampes à LED autoballastées pour l'éclairage général avec des tensions d'alimentation > 50 V - Exigences de performances
La CEI 62612:2013 spécifie les exigences de performances, ainsi que les conditions et les méthodes d'essais, requises pour assurer la conformité des lampes à LED à dispositif de stabilisation incorporé, destinées à l'éclairage domestique et à l'éclairage général similaire, ayant: - une puissance assignée pouvant atteindre 60 W; - une tension assignée comprise entre 50 V c.a. et 250 V c.a.; - un culot de lampe tel qu'indiqué dans la CEI 62560. Cette première édition de la CEI 62612 annule et remplace la CEI/PAS 62612. Cette édition constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à la CEI/PAS 62612. a) La norme indique explicitement que les essais de durée de vie réelle ne font pas partie du régime d'essais. Au lieu de cela, on choisit une période pouvant atteindre 6 000 h pour évaluer les déclarations de maintien données par un fabricant. b) Des caractéristiques techniques ont été adaptées autant que possible à la CEI/PAS 62717 (performances des modules de LED). Des exemples incluent l'utilisation de familles et le point de mesure de la température. c) Les exigences de marquage s'appliquent au boîtier et non au produit. d) Le nombre de lampes à soumettre aux essais est spécifique aux essais. e) Les premières exigences sont données pour régler la couleur des lampes à couleur ajustable et le niveau de flux lumineux des lampes à variation d'intensité. f) La structure des essais est divisée entre exigences et conformité. g) La conformité statistique est divisée en individuelle et moyenne. h) Les exigences sur la lumière de sortie sont étendues à la distribution d'intensité lumineuse, l'intensité de crête, l'angle de faisceau et l'efficacité. i) L'utilisation des termes 'température de couleur proximale' et 'coordonnées trichromatiques' est corrigée. j) Le nombre de catégories de tolérance est réduit de 8 à 4 et divisé entre les valeurs initiales et valeurs de maintien. k) Le rendu des couleurs est évalué différemment à l'état initial et à l'état de maintien. l) Trois catégories de maintien de flux lumineux sont données au lieu de cinq. m) Les essais d'endurance sont entièrement rétablis. n) L'article sur la vérification (auparavant appelée évaluation) est complété. o) Des informations pour la conception de luminaires sont ajoutées. p) La stabilisation est plus précise (Annexe A sur la méthode de mesure des caractéristiques des lampes) et des paramètres photométriques et colorimétriques supplémentaires ont été ajoutés. q) L'Annexe B sur la mesure du flux lumineux est incluse dans l'Annexe A. Une nouvelle Annexe B fournit le code photométrique. r) D'autres annexes ont été ajoutées. L'Annexe C et l'Annexe D sur le facteur de déplacement, l'Annexe E sur les valeurs et la fiabilité de la durée de vie et l'Annexe F qui donne des exemples de puces de LED et de boîtier de LED.
LED-sijalke za splošno razsvetljavo z vgrajeno predstikalno napravo pri napajalni napetosti nad 50 V - Tehnične zahteve
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2017
/('VLMDONH]DVSORãQRUD]VYHWOMDYR]YJUDMHQRSUHGVWLNDOQRQDSUDYRSULQDSDMDOQL
QDSHWRVWLQDG97HKQLþQH]DKWHYH
Self-ballasted LED lamps for general lighting services with supply voltages > 50 V -
Performance requirements
LED-Lampen mit eingebautem Vorschaltgerät für Allgemeinbeleuchtung mit
Versorgungsspannungen > 50 V - Anforderungen an die Arbeitsweise
Lampes à LED autoballastées pour l'éclairage général avec des tensions d'alimentation
> 50 V - Exigences de performances
Ta slovenski standard je istoveten z: EN 62612:2013/A11:2017
ICS:
29.140.01 Žarnice na splošno Lamps in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN 62612:2013/A11
NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2017
ICS 29.140.01
English Version
Self-ballasted LED lamps for general lighting services with
supply voltages > 50 V - Performance requirements
Lampes à LED autoballastées pour l'éclairage général avec LED-Lampen mit eingebautem Vorschaltgerät für
des tensions d'alimentation > 50 V - Exigences de Allgemeinbeleuchtung mit Versorgungsspannungen > 50 V
performances - Anforderungen an die Arbeitsweise
This amendment A11 modifies the European Standard EN 62612:2013; it was approved by CENELEC on 2017-02-20. CENELEC members
are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the status of a
national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 62612:2013/A11:2017 E
European foreword
This document (EN 62612:2013/A11:2017) has been prepared by CLC/TC 34A,"Lamps".
The following dates are fixed:
(dop) 2018-02-20
• latest date by which the document has to be implemented at
national level by publication of an identical national
standard or by endorsement
(dow) 2020-02-20
• latest date by which the national standards conflicting with
the document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Clauses, subclauses, notes, tables, figures and annexes which are additional to those in
IEC 62612:2013 and IEC 62612:2013/A1:2015 are prefixed “Z”.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association, and supports essential requirements of EU Directive(s).
For the relationship with EU Directive(s), see informative Annexes ZZA, ZZB and ZZC, which are an
integral part of this document.
This standard provides test methods related to parameters as prescribed by Commission Regulation
(EC) 244/2009, Commission Regulation (EU) 1194/2012 and Commission Regulation (EU) 874/2012
while conformity assessment (sampling, conformity procedures as well as limits) for market
surveillance are specified in the text of the above Regulations.
CONTENTS Add the following annexes:
Annex ZA (normative) Normative references to international publications with their
corresponding European publications
Annex ZZA (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EC) No 244/2009
Annex ZZB (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EC) No 1194/2012
Annex ZZC (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EC) No 874/2012
1.0.Z1 Add the following clause before Clause 2
1.0.Z1 Overall statement
Where a Commission Regulation specifies limits for parameters these limits shall be
used instead of the limits specified in this standard.
3.Z1 After 3.21 add new definitions 3.Z1 up to 3.Z2:
3.Z1
partial luminous flux (of a light source, within a specified cone angle)
luminous flux emitted from a light source within a specified cone angle α, determined
from the luminous intensity distribution I(θ, ϕ) of the source:
2π α /2
Φ = I(θ,ϕ) sinθ dθ dϕ
α
∫∫
ϕθ00
(2)
Note 1 to entry: Partial luminous flux is expressed in lumen (lm)
Note 2 to entry: (θ, ϕ)=(0,0) is the direction of the cone axis
Note 3 to entry: The cone angle α is the full angle (diameter) of the cone
[SOURCE: EN 13032-4, 3.41, modified, – Notes 4 and 5 removed]
3.Z2
useful luminous flux
Φ
use
partial luminous flux of a LED lamp falling within the cone used for calculating the LED
lamp’s energy efficiency according Annex III, point 1.1 of regulation (EU) No
1194/2012
Note 1 to entry: Useful luminous flux is expressed in lumen (lm)
Note 2 to entry: The regulation specifies 90° or 120° cones according to the product characteristics
Note 3 to entry: useful luminous flux is similar to partial luminous flux. It is determined with the cone axis
coincident with the observed optical beam axis of the light source, the axis about which
the luminous intensity is substantially symmetrical
Z1 After Clause 12 add the following new clauses:
Z1 Requirements for directional LED lamps
Z1.1 Correlated colour temperature
Correlated colour temperature of a LED lamp shall be measured in accordance with
7.1, Colorimetric Measurements of EN 13032-4.
==
Z1.2 Useful luminous flux
The useful luminous flux of a directional LED lamp shall be measured according
Annex A together with the following:
- useful luminous flux of a directional LED lamp with a rated beam angle ≥ 90° shall
be measured in a 120° cone;
- otherwise the useful luminous flux of a directional LED lamp shall be measured in
90° cone.
If no rated beam angle is provided the useful luminous flux shall be measured in a 90°
cone.
Z1.3 - Functionality requirements
Z1.3.1 - Spectral power distribution
The measurement of the spectral power distribution shall be made under the
conditions of A.1 and in accordance with CIE 63.
Z1.3.2 Lamp starting and warm-up time
The starting time requirements for LED lamps that are intended to be switched on and
off via a communication protocol (and normally not by switching the mains supply on
and off) shall be determined from the time that the lamp receives an “on” signal
Starting and warm-up times shall be carried out as follows:
The test for starting and warm-up times shall be carried out in accordance with
FprEN 60969:2016, B.3.
Starting time is determined as the period from the start of the test to when the LED
lamp has fully completed the starting sequence (LED lamp has started and remains
alight).
Warm-up time is the time taken from the start of the test to when the LED lamp
achieves the required percentage of its stable luminous flux.
Z1.3.3 - Colour rendering (R )
a
Measurement of colour rendering indices shall be made in accordance with Annex A.
Z1.3.4 - Colour consistency
The requirements of 10.1 apply.
Compliance:
The variation of the chromaticity coordinates values of the LED lamp shall be within
colour variation category 6.
NOTE Category 6 implies a 6-step MacAdam ellipse centred on the rated colour target.
Z1.3.5 - Power factor
LED lamps operating on direct mains shall be in accordance with 8.1 and 8.2. The
distortion shall be measured according EN 61000-3-2 and the power factor λ be
calculated according to the relation given in D.1.
NOTE In view of future regulations, EN 62612 defines - the primary metric displacement factor and its
associated measurement method and recommended values – instead of the composite power factor metric.
Definitions related to power quantities are given in Table 2 of IEC/TR 61000-1-7:2016.
Z2 Requirements for non-directional LED lamps
Z2.1 Lamp efficacy requirements for non-directional LED lamps
The requirements of 8.1 and 9.1 apply in combination with the limits in Annex II, article
1 of commission regulation (EU) No 244/2009.
Z2.2 Functionality requirements for non-directional LED lamps
The requirements of Z1.3 apply.
Annex A.1 Replace the entire A.1 in EN 62612:2013 and EN 62612:2013/A1:2017 by:
A.1 General
Unless otherwise specified, all measurements shall be made in a draught-free room at
a temperature of 25 °C with a tolerance of ± 1 °C, a relative humidity of 65 %
maximum and steady state operation of the LED lamp.
If not exempted by specific clause, lamps shall be operated free burning in a vertical
position, cap-up, unless otherwise specified by the manufacturer or responsible
vendor.
The test voltage shall be the voltage as determined in A.2.4.
LED lamps do not require any ageing prior to testing. However, the manufacturer may
define an aging period up to 1 000 h.
For general conditions of photometric measurements see EN 13032-4.
For directional LED lamps the useful luminous flux is obtained by luminous intensity
integration according to EN 13032-4:2015, 6.3 "Partial luminous flux". Alternative
measurement methods may be used if they can be shown to give equivalent results
for the product being tested, if necessary by applying correction factors. However, the
lamp reference measurement position is vertical base-up operated in free air. In case
of doubt a goniophotometry measurement in accordance with EN 13032-4:2015, 6.3
shall be leading.
NOTE 1 Useful luminous flux measurements with lamps operating horizontally are often easier to carry
out. Examples of alternative measurement methods are.
• For small beam angles shine into integrating sphere.
• Mount lamp on internal surface of integrating sphere.
• Mount lamp inside integrating sphere with screening (LM-20 technique).
• Illuminate a surface and measure the illuminance across the surface with a photometer.
• Illuminate a surface and measure the surface luminance with a luminance camera.
• Illuminate a translucent screen and measure the surface luminance of the rear side with a luminance
camera.
For non-directional LED lamps the total luminous flux shall be measured according to
EN 13032-4. Also the partial luminous flux within a solid angle of π sr of the LED
lamps shall be evaluated to check the non-directionality.
Once the non-directionality is verified for one lamp, for lamps of the same type, only
the total luminous flux has to be measured.
Luminous intensity distribution shall be measured in accordance with EN 13032-4 and
EN 61341.
NOTE 2 EN13032-4 refers to EN 61341 for beam angle evaluation.
Chromaticity coordinates of a LED lamps shall be measured in accordance with 7.1,
Colorimetric Measurements of EN 13032-4:2015.
Annex A.3 Delete the entire A.3.
Bibliography Add the following documents:
COMMISSION REGULATION (EU) No 1194/2012 of 12 December 2012
implementing Directive 2009/125/EC of the European Parliament and of the Council
with regard to ecodesign requirements for directional lamps, light emitting diode lamps
and related equipment
COMMISSION REGULATION (EC) No 874/2012 of 12 December 2012
supplementing Directive 2010/30/EU of the European Parliament and of the Council
with regard to energy labelling of electrical lamps and luminaires
COMMISSION REGULATION (EC) No 244/2009 of 18 March 2009 implementing
Directive 2009/125/EC of the European Parliament and of the Council with regard to
ecodesign requirements for non-directional household lamps
IEC TR 61000-1-7 2016-02 Electromagnetic compatibility (EMC). Part 1-7: General.
Power factor in single-phase systems under non-sinusoidal conditions
Replace Annex ZA of EN 62612:2013 by:
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is
available here: www.cenelec.eu.
Publication Year Title EN/HD Year
Light and lighting - Measurement and EN 13032-1 2004
presentation of photometric data of + A1 2012
lamps and luminaires - Part 1:
Measurement and file format
Light and lighting - Measurement and EN 13032-4 2015
presentation of photometric data -
Part 4: LED lamps, modules and
luminaires
IEC 60050 series International Electrotechnical - -
Vocabulary (IEV)
IEC 60068-2-14 2009 Environmental testing - Part 2-14: EN 60068-2-14 2009
Tests - Test N: Change of temperature
IEC 60081 1997 Double-capp
...