Home and Building Electronic Systems (HBES) - Part 4-1: Media independent layers - Application layer for HBES Class 1

This part of the EN 50090 specifies the services and protocol of the application layer for usage in Home and Building Electronic Systems. It provides the services and the interface to the user process as defined in EN 50090 3 2. This procedure is based on the services and the protocol is provided by the Transport Layer, Network Layer and Data Link Layer as specified in EN 50090 4 2.

Elektrische Systemtechnik für Heim und Gebäude (ESHG) - Teil 4-1: Medienunabhängige Schicht - Anwendungsschicht für ESHG Klasse 1

Systèmes électroniques pour les foyers domestiques et les bâtiments (HBES) - Partie 4-1: Couches indépendantes des media - Couche application pour HBES Classe 1

Stanovanjski in stavbni elektronski sistemi (HBES) – 4-1. del: Nivoji, neodvisni od medijev – Aplikacijski nivo za HBES razreda 1

General Information

Status
Published
Publication Date
19-Feb-2004
Withdrawal Date
30-Nov-2006
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
04-Oct-2023

Buy Standard

Standard
EN 50090-4-1:2005
English language
80 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI SIST EN 50090-4-1:2005

STANDARD
september 2005
Stanovanjski in stavbni elektronski sistemi (HBES) – 4-1. del: Nivoji,
neodvisni od medijev – Aplikacijski nivo za HBES razreda 1
Home and Building Electronic Systems (HBES) – Part 4-1: Media independent
layers – Application layer for HBES Class 1
ICS 97.120 Referenčna številka
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

EUROPEAN STANDARD EN 50090-4-1
NORME EUROPÉENNE
EUROPÄISCHE NORM February 2004

ICS 35.100.70; 97.120 Supersedes R205-007:1996

English version
Home and Building Electronic Systems (HBES)
Part 4-1: Media independent layers –
Application layer for HBES Class 1

Systèmes électroniques pour les foyers Elektrische Systemtechnik für Heim
domestiques et les bâtiments (HBES) und Gebäude (ESHG)
Partie 4-1: Couches indépendantes Teil 4-1: Medienunabhängige Schicht –
des media – Anwendungsschicht für ESHG Klasse 1
Couche application pour HBES Classe 1

This European Standard was approved by CENELEC on 2003-12-02. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in one official version (English). A version in any other language made by
translation under the responsibility of a CENELEC member into its own language and notified to the Central
Secretariat has the same status as the official version.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 50090-4-1:2004 E
Contents
Foreword.4
Introduction.5
1 Scope .5
2 Normative references .5
3 Terms, definitions and abbreviations .5
3.1 Terms and definitions.5
3.2 Abbreviations .6
4 Services of the application layer .6
4.1 Communication modes .6
4.2 Service primitives of the application layer.7
5 Application layer Protocol Data Unit (APDU) .8
6 Application layer services.11
6.1 Application layer services on multicast communication mode.11
6.2 Application layer services on broadcast communication mode .17
6.3 Application layer services on point-to-point connection-less communication mode.36
6.4 Application layer services on point-to-point connection-oriented communication mode .51
6.5 Router-specific application layer services on point-to-point connection-oriented
communication mode.79
7 Parameters of application layer.80
7.1 Association table.80
7.2 Verify flag .80
Figure 1 – Interaction of the application layer for services that are not remote confirmed .7
Figure 2 – Interaction of the application layer for services that are remote confirmed .8
Figure 3 – APDU (example) .8
Figure 4 – Mapping the ASAP to the TSAP (example) .11
Figure 5 – Mapping a TSAP to an ASAP .11
Figure 6 – Handling requests and responses.11
Figure 7 – Message flow for the A_Group_Value_Read service .12
Figure 8 – A_GroupValue_Read-PDU (example) .12
Figure 9 – A_GroupValue_Response-PDU (example), length of ASAP data is more than 6 bit .13
Figure 10 – A_GroupValue_Response-PDU (example) length of ASAP data is 6 bit or less.13
Figure 11 – Message flow for the A_Group_Value_Write service .15
Figure 12 – A_GroupValue_Write-PDU (example), length of ASAP data is more than 6 bit.16
Figure 13 – A_GroupValue_Write-PDU (example), length of ASAP data is 6 bit or less .16
Figure 14 – A_IndividualAddress_Write-PDU (example).17
Figure 15 – A_IndividualAddress_Read-PDU (example).19
Figure 16 – A_IndividualAddress_Response-PDU (example) .19
Figure 17 – Message flow for the A_IndividualAddressSerialNumber_Read service.21
Figure 18 – A_IndividualAddressSerialNumber_Read-PDU (example).22
Figure 19 – A_IndividualAddressSerialNumber_Response-PDU (example).22
Figure 20 – A_IndividualAddressSerialNumber_Write-PDU (example).24
Figure 21 – A_ServiceInformation_Indication_Write-PDU (example).26

– 3 – EN 50090-4-1:2004
Figure 22 – A_DomainAddress_Write-PDU.27
Figure 23 – A_DomainAddress_Read-PDU (example).29
Figure 24 – A_DomainAddress_Response-PDU (example).29
Figure 25 – A_DomainAddressSelective_Read-PDU (example).31
Figure 26 – A_NetworkParameter_Read-PDU (example) .32
Figure 27 – A_NetworkParameter_Response-PDU (example).33
Figure 28 – A_NetworkParameter_Write-PDU (example) .35
Figure 29 – A_PropertyValue_Read-PDU (example) .37
Figure 30 – A_PropertyValue_Response-PDU (example).37
Figure 31 – A_PropertyValue_Write-PDU (example).40
Figure 32 – A_PropertyDescription_Read-PDU (example).43
Figure 33 – A_PropertyDescription_Response-PDU (example).43
Figure 34 – A_DeviceDescriptor_Read-PDU (example).46
Figure 35 – A_DeviceDescriptor_Response-PDU (example) .47
Figure 36 – Message flow for A_Link_Read Service .48
Figure 37 – A_Link_Read-PDU (example).49
Figure 38 – A_Link_Response-PDU .49
Figure 39 – Message flow for A_Link_Write Service .50
Figure 40 – A_Link_Write-PDU .50
Figure 41 – A_ADC_Read-PDU (example).52
Figure 42 – A_ADC_Response-PDU (example) .52
Figure 43 – A_Memory_Read-PDU (example) .54
Figure 44 – A_Memory_Response-PDU (example).55
Figure 45 – A_Memory_Write-PDU (example).57
Figure 46 – A_MemoryBit_Write-PDU .60
Figure 47 – A_UserMemory_Read-PDU (example).63
Figure 48 – A_UserMemory_Response-PDU .63
Figure 49 – A_UserMemory_Write-PDU .66
Figure 50 – A_UserMemoryBit_Write-PDU (example).69
Figure 51 – A_UserManufacturerInfo_Read-PDU (example) .72
Figure 52 – A_UserManufacturerInfo_Response-PDU.72
Figure 53 – A_Restart-PDU (example) .74
Figure 54 – A_Authorize_Request-PDU (example) .75
Figure 55 – A_Authorize_Response-PDU (example) .76
Figure 56 – A_Key_Write-PDU (example) .78
Figure 57 – A_Key_Response-PDU (example) .78
Table 1 – APCI overview.9
Table 2 – Function table for A_MemoryBit_Write-Services .59
Table 3 – Function table for A_UserMemoryBit_Write-Services.68
Table 4 – Association table of keys to access levels .77

Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 205, Home and
Building Electronic Systems (HBES) with the help of CENELEC co-operation partner Konnex Association
(formerly EHBESA).
The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC
as EN 50090-4-1 on 2003-12-02.
This European Standard supersedes R205-007:1996.
CENELEC takes no position concerning the evidence, validity and scope of patent rights.
Konnex Association as Cooperating Partner to CENELEC confirms that to the extent that the standard
contains patents and like rights, the Konnex Association's members are willing to negotiate licenses
thereof with applicants throughout the world on fair, reasonable and non-discriminatory terms and
conditions.
Konnex Association Tel.: + 32 2 775 85 90
Neerveldstraat, 105 Fax.: + 32 2 675 50 28
Twin House e-mail: info@konnex.org
B - 1200 Brussels www.konnex.org
Attention is drawn to the possibility that some of the elements of this standard may be the subject of
patent rights other than those identified above. CENELEC shall not be held responsible for identifying any
or all such patent rights.
The following dates were fixed:
– latest date by which the EN has to be implem
...

Questions, Comments and Discussion