EN 50325-2:2000
(Main)Industrial communications subsystem based on ISO 11898 (CAN) for controller-device interfaces - Part 2: DeviceNet
- BACK
- 29-Oct-2000
- 31-Dec-2002
- 43.180
- CLC/TC 65X
Industrial communications subsystem based on ISO 11898 (CAN) for controller-device interfaces - Part 2: DeviceNet
Standard exists in English only * Superseded by EN 62026-3:2009
Industrial communications subsystem based on ISO 11898 (CAN) for controller-device interfaces - Part 2: DeviceNet
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-2001
Industrial communications subsystem based on ISO 11898 (CAN) for controller-
device interfaces - Part 2: DeviceNet
Industrial communications subsystem based on ISO 11898 (CAN) for controller-device
interfaces -- Part 2: DeviceNet
Ta slovenski standard je istoveten z: EN 50325-2:2000
ICS:
35.240.50 Uporabniške rešitve IT v IT applications in industry
industriji
43.040.15 $YWRPRELOVNDLQIRUPDWLND Car informatics. On board
9JUDMHQLUDþXQDOQLãNLVLVWHPL computer systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...
This May Also Interest You
This European Standard applies to controller device interfaces that provide defined interfaces between low voltage switchgear, controlgear, control circuit devices, switching elements and controlling devices (e.g. programmable controllers, personal computers, etc.). It may also be applied for the interfacing of other devices and elements to a controller device interface. This standard specifies requirements for controllers and devices utilising these interfaces, including not only the communication protocol specification, but also associated relevant electrical and mechanical characteristics. It also specifies the electrical and EMC tests required to verify the performance of each controller device interface when connected to the appropriate controllers and devices. This part 1 establishes a consistent terminology and format for the subsequent interfaces. It also harmonises requirements of a general nature in order to reduce the need for testing to different standards, increase understanding and facilitate comparisons of controller device interface standards. Those requirements of the various controller device interface standards which can be considered as general have therefore been gathered in this part 1. In addition to meeting the specific requirements stated in this part 1, the controller device interfaces included in this standard are documented in the English language in accordance with the requirements specified in this part 1, are already in use in commercial products and running in industrial plants, are available in quantity and at low price, are available from several sources and commercialised openly, to satisfy the tests specified, amongst others, in EN 61000 4 2, EN 61000 4 3, EN 61000 4 4, EN 61000 4 5, and EN 61000 4 6 against the test levels specified in EN 50082 2, have appropriate mechanisms for transmission error detection, are open, widely accepted, well documented, stable and support inter operability, are complete and describe the necessary interfaces in sufficient detail to enable error free implementation, are free of any restriction related to testing the implementation. For each controller device interface only two documents are necessary to determine all requirements and tests: the general requirements of this standard, referred to as "part 1" in the relevant parts covering the various types of controller device interfaces; the relevant controller device interface standard hereinafter referred to as the "relevant controller device interface standard" or "controller device interface standard". The solutions described in this standard have been used for many years by industry to solve application requirements involving low voltage switchgear and controlgear. They are characterised by: their ability to power connected devices directly from the network; their ability to operate in harsh environments typified by those encountered at the machine level by controls in industrial applications; usage of the sophisticated medium access rules of CAN which allows both organisation of traffic based on user assigned priorities and efficient resolution of occasional access conflict; a wide range of exchange services allowing precise tailoring of data exchange to the actual application needs as well as simultaneous distribution of data to a selected set of connected devices; their capability to simultaneously support data acquisition, diagnostics, messaging and programming/configuration as required, amongst others, for systems interfacing controllers to low voltage switchgear and controlgear in industrial applications. NOTE The controller device interface standards currently part of this series are: EN 50325 2: DeviceNet EN 50325 3: Smart Distributed System (SDS) EN 50325-4: CANopen EN 50325-5 : Functional safety communication based on EN 50325-4
- Standard14 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2019
- 31-Oct-2022
- 43.180
- CLC/TC 65X
EN 50325-4 specifies the following particular requirements for CANopen: • requirements for interfaces between programmable controllers and devices with input/output capabilities; • normal service conditions for devices; • constructional and performance requirements.
- Standard115 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Dec-2002
- 30-Jun-2005
- 43.180
- CLC/TC 65X
This European Standard applies to controller device interfaces that provide defined interfaces between low voltage switchgear, controlgear, control circuit devices, switching elements and controlling devices (e.g. programmable controllers, personal computers, etc.). It may also be applied for the interfacing of other devices and elements to a controller device interface. This standard specifies requirements for controllers and devices utilising these interfaces, including not only the communication protocol specification, but also associated relevant electrical and mechanical characteristics. It also specifies the electrical and EMC tests required to verify the performance of each controller device interface when connected to the appropriate controllers and devices. This part 1 establishes a consistent terminology and format for the subsequent interfaces. It also harmonises requirements of a general nature in order to reduce the need for testing to different standards, increase understanding and facilitate comparisons of controller device interface standards. Those requirements of the various controller device interface standards which can be considered as general have therefore been gathered in this part 1. In addition to meeting the specific requirements stated in this part 1, the controller device interfaces included in this standard are documented in the English language in accordance with the requirements specified in this part 1, are already in use in commercial products and running in industrial plants, are available in quantity and at low price, are available from several sources and commercialised openly, to satisfy the tests specified, amongst others, in EN 61000 4 2, EN 61000 4 3, EN 61000 4 4, EN 61000 4 5, and EN 61000 4 6 against the test levels specified in EN 50082 2, have appropriate mechanisms for transmission error detection, are open, widely accepted, well documented, stable and support inter operability, are complete and describe the necessary interfaces in sufficient detail to enable error free implementation, are free of any restriction related to testing the implementation. For each controller device interface only two documents are necessary to determine all requirements and tests: the general requirements of this standard, referred to as "part 1" in the relevant parts covering the various types of controller device interfaces; the relevant controller device interface standard hereinafter referred to as the "relevant controller device interface standard" or "controller device interface standard". The solutions described in this standard have been used for many years by industry to solve application requirements involving low voltage switchgear and controlgear. They are characterised by: their ability to power connected devices directly from the network; their ability to operate in harsh environments typified by those encountered at the machine level by controls in industrial applications; usage of the sophisticated medium access rules of CAN which allows both organisation of traffic based on user assigned priorities and efficient resolution of occasional access conflict; a wide range of exchange services allowing precise tailoring of data exchange to the actual application needs as well as simultaneous distribution of data to a selected set of connected devices; their capability to simultaneously support data acquisition, diagnostics, messaging and programming/configuration as required, amongst others, for systems interfacing controllers to low voltage switchgear and controlgear in industrial applications. NOTE The controller device interface standards currently part of this series are: EN 50325 2: DeviceNet EN 50325 3: Smart Distributed System (SDS) EN 50325-4: CANopen EN 50325-5 : Functional safety communication based on EN 50325-4
- Standard14 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2019
- 31-Oct-2022
- 43.180
- CLC/TC 65X
EN 50325-4 specifies the following particular requirements for CANopen: • requirements for interfaces between programmable controllers and devices with input/output capabilities; • normal service conditions for devices; • constructional and performance requirements.
- Standard115 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Dec-2002
- 30-Jun-2005
- 43.180
- CLC/TC 65X
This document specifies the main characteristics of the voltage at a network user's supply terminals in public low voltage, medium, high, and extra-high voltage AC electricity networks under normal operating conditions. This document specifies the limits or values within which the voltage characteristics can be expected to remain at any supply terminal in public European electricity networks, only. Industrial networks are excluded from the scope of EN 50160. NOTE 1 If non-public networks (e.g. residential quarters, energy communities, office centres, shopping centres) have similar end-users as public networks, it is strongly advised to apply the same requirements as for public networks. This document does not apply under abnormal operating conditions, including the following: a) a temporary supply arrangement to keep network users supplied during conditions arising as a result of a fault, maintenance and construction work, or to minimize the extent and duration of a loss of supply; b) in the case of non-compliance of a network user's installation or equipment with the relevant standards or with the technical requirements for connection, established either by the public authorities or the network operator, including the limits for the emission of conducted disturbances; NOTE 2 A network user’s installation can include load and generation. c) in exceptional situations, in particular: 1) exceptional weather conditions and other natural disasters; 2) third party interference; 3) acts by public authorities, 4) industrial actions (subject to legal requirements); 5) force majeure; 6) power shortages resulting from external events. The voltage characteristics given in this document refer to conducted disturbances in public electric power networks. They are not intended to be used as electromagnetic compatibility (EMC) levels or product emission limits. Power quality is related to EMC in several ways - especially because compliance with power quality requirements depends on the control of cumulative effect of electromagnetic emissions from all/multiple equipment and/or installations. Therefore, the voltage characteristics given in this document gives guidance for specifying requirements in equipment product standards and in installation standards. NOTE 3 The performance of equipment might be impaired if it is subjected to supply conditions which are not specified in the equipment product standard. NOTE 4 This document can be superseded in total or in part by the terms of a contract between the individual network user and the network operator. The sharing of complaint management and problem mitigation costs between the involved parties is outside the scope of EN 50160. Measurement methods to be applied in this document are described in EN 61000-4-30.
- Draft7 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft10 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 63261:2024 provides requirements for the E&I objects of a digital 3D plant model, used in the engineering phase to design and construct a process plant and its instrumentation. It provides guidance how to model plants and their electrical and instrumentation equipment. This document also specifies the content and the possible output of the 3D plant model at project milestones. This document can be used by the contractual partners to agree upon the content of the 3D plant model to be delivered at specified milestones. This document does not specify the transfer and format of digital 3D plant models. This document does not specify definitions or instructions to equipment representations and details of elements in the 3D plant model not belonging to electrical and instrumentation domains.
- Draft9 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2024
- 25.040.40
- CLC/TC 65X
IEC 62683-2:2024 specifies the functional safety and reliability data model descriptions for low‑voltage switchgear and controlgear to be used by engineering tools for the design of safety related control systems according to IEC 62061, IEC 61508-2 and ISO 13849-1, and for dependability analysis of electrotechnical systems. This dictionary is used to facilitate the exchange between computers of data characterizing low-voltage switchgear and controlgear. Each property has an unambiguously defined meaning and naming, and where relevant, a defined value list, a defined format and a defined unit. The data models described in this document are intended to complement the product catalogue data defined by IEC 62683-1. This document does not cover: - exchange format such as defined in VDMA 66413, - explosive atmosphere applications, - manufacturer specific features.
- Draft15 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2024
- 29.130.20
- CLC/SR 121
IEC 60601-2-34:2024 applies to BASIC SAFETY and ESSENTIAL PERFORMANCE of INVASIVE BLOOD PRESSURE MONITORING EQUIPMENT as defined in 201.3.63, hereinafter also referred to as ME EQUIPMENT. This document applies to INVASIVE BLOOD PRESSURE MONITORING EQUIPMENT intended for use in professional healthcare facilities and in the EMERGENCY MEDICAL SERVICE ENVIRONMENT. This document does not apply to catheter tubing, catheter needles, Luer locks, taps and tap tables that connect to the DOME. This document does not apply to non-invasive blood pressure monitoring equipment. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as follows: The clause or subclause applies to ME EQUIPMENT, as default and, only if the corresponding safety measure or function is not completely integrated into the ME EQUIPMENT but implemented as part of an ME SYSTEM, the clause or subclause applies to the ME SYSTEM. IEC 60601-2-34:2024 cancels and replaces the third edition of IEC 60601-2-34 published in 2011 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) revision to align with IEC 60601-1:2005, IEC 60601-1:2005/AMD1:2012 and IEC 60601-1:2005/AMD2:2020, as well as new versions of collateral standards and amendments thereto; b) expansion of the scope to the emergency medical service environment; c) changed essential performance in Table 201.101; d) changed requirement for ingress protection; e) added primary operating functions; f) deleted Annex BB Alarm diagrams.
- Draft59 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft3 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion