EN 190103:1994
(Main)Family Specification: Digital integrated TTL low power Schottky circuits - Series 54LS, 64LS, 74LS, 84LS
- BACK
- 14-May-1994
- 29-Feb-1996
- CLC/SR 47A
Family Specification: Digital integrated TTL low power Schottky circuits - Series 54LS, 64LS, 74LS, 84LS
Supersedes CECC 90 103:1988 (with A1 and A2) * CECC WG 9 work handled by SR 47A
Familienspezifikation: Digitale integrierte TTL low power Schottky-Schaltungen - Serien 54LS, 64LS, 74LS, 84LS
Spécification de famille : circuits intégrés digitaux TTL low power Schottky - Séries 54LS, 64LS, 74LS, 84LS
Family specification: Digital TTL low power Schottky circuits - Series 54LS, 64LS, 74LS, 84LS
General Information
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Family specification: Digital TTL low power Schottky circuits - Series 54LS, 64LS, 74LS, 84LSFamilienspezifikation: Digitale integrierte TTL low power Schottky-Schaltungen - Serien 54LS, 64LS, 74LS, 84LSSpécification de famille: Circuits intégrés digitaux TTL low power Schottky - Séries 54LS, 64LS, 74LS, 84LSFamily Specification: Digital integrated TTL low power Schottky circuits - Series 54LS, 64LS, 74LS, 84LS31.200Integrirana vezja, mi
...
This May Also Interest You
IEC 60947-5-7:2024 states the requirements for proximity devices that correspond to the scope of IEC 60947-5-2:2019 with analog output (PDAO) and/or a digital output to transmit a corresponding digital value representing the detected sensing input. These devices can provide additional parameters. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) New structure; b) Update and expansion of definitions on analog output properties; c) Expanded performance requirements on analog output; d) Update and new normative references; e) Update of EMC requirements; f) Harmonization with IEC 62828 series; g) Harmonization with IEC 62683 and IEC 61987 definitions; h) Harmonization with IEC 61131-2 requirements; i) Update of the Annex A (former Annex G), Example of the determination of the conformity; j) New Annex B, Overview tests and influence quantities; k) New Annex C, Additional requirements for proximity switches with analog output incorporating a built-in communication interface complying with IEC 61131-9; l) New Annex D, Main characteristics for proximity devices with analog output.
- Draft45 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60947-4-1:2023 is applicable to the following equipment: - electromechanical contactors and starters including motor protective switching devices (MPSD and IMPSD); - actuators of contactor relays; - contacts dedicated exclusively to the coil circuit of the contactor or the contactor relay; - dedicated accessories (e.g. dedicated wiring, dedicated latch accessory); intended to be connected to distribution circuits, motors circuits and other load circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC. This fifth edition cancels and replaces the fourth edition published in 2018. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) objective in the scope; b) instantaneous only motor protective switching device IMPSD (3.5.33); c) kinds of equipment (5.2.1); d) methods of overload protection of motors (5.2.6); e) adoption of the AC-7d from IEC 61095:2023 (in 5.4.2); f) separately mounted overload relay of a starter (in 5.7.3 b)); g) starter and contactor suitable for use downstream to basic drive module (6.1.2 w)); h) reference to IEC TS 63058 for environmental aspects (in 6.4); i) wiring subject to movement (in 8.1.3); j) use of voltage transient limiting device (8.1.18); k) accessible parts subject to temperature limits (in 8.2.2.3); l) reference to Annex X of IEC 60947-1:2020 for the co-ordination of MPSD with SCPD (8.2.5.4); m) reference to IEC TR 63216 with different EMC environments (8.3.1); n) reference to IEC TR 63201 for the embedded software design (8.4); o) reference to IEC TS 63208 for cybersecurity aspects (8.5); p) update and completion of the measurement method of the power consumption of the electromagnet (9.3.3.2.1.2); q) update of Annex C including rational about AC-3e; r) determination of the critical load current for photovoltaic applications (M.8.7).
- Draft179 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 62626-1:2023 is available as IEC 62626-1:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62626-1:2023 applies to enclosed switches-disconnectors with rated voltages up to 1 000 V AC for repair and maintenance work or cleaning work in load circuits. Devices within the scope of this document are switch-disconnectors in accordance with IEC 60947-3 with specific additional requirements. Enclosed switch-disconnectors in this document are suitable for isolation in accordance with the IEC 60947 series and are not equipped with means for remote control or automatic switching to avoid unexpected or accidental start. These devices are not used for operational switching, for example quick start and stop, jogging. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) update of this document based on IEC 60947-1:2020.
- Draft11 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Sep-2025
- 29.120.40
- 29.130.20
- 2014/35/EU
- M/511
- CLC/TC 121A
IEC 61095:2023 is available as IEC 61095:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61095:2023 applies to electromechanical air break contactors for household and similar purposes provided with main contacts intended to be connected to circuits the rated voltage of which does not exceed 440 V AC (between phases) with rated operational currents less than or equal to 63 A for utilization category AC-7a, and 32 A for utilization categories AC‑7b, AC‑7c and AC-7d (expressed in rated power), and rated conditional short-circuit current less than or equal to 6 kA. This third edition cancels and replaces the second edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of requirements for screwless terminals; b) addition of requirements for the switching of LED lamps. Contactors for domestic and similar applications can be used for controlling lighting loads which is increasingly using LED lamp technology. A specific category for contactors is created: AC-7d. Requirements and tests are added to cover this market development, mainly for making and breaking and conventional operational performance; c) addition of requirements for contactors with electronically controlled electromagnet. Household contactors with electronically controlled electromagnet are available for years on the market. To fully cover such device, requirements and tests are added, dealing mainly with operating limits, behaviour in abnormal conditions, breakdown of components, EMC tests, etc. d) embedded software. More and more contactors are incorporating electronic circuits with embedded software. A reference is provided to guide the design of the software.
- Draft141 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60931-1:2025 is applicable to both non-self-healing capacitor units and non-self-healing capacitor banks intended to be used, particularly, for power-factor correction of AC power systems having a rated voltage up to and including 1 000 V and frequencies 15 Hz to 60 Hz. This document also applies to capacitors intended for use in power filter circuits.
- Standard43 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 63402-1:2025 specifies general requirements and the architecture between the Point of Common Coupling (PCC) and smart devices (SD) operating within the Smart Grid premises-side system (i.e. residential or commercial but not industrial premises). This document does not include requirements for: - safety - electromagnetic compatibility (EMC); - data security, as it is assumed that the underlying protocols will take the data security aspect into account - special equipment (e.g. legacy heat pumps) with a direct physical connection to the grid, as such equipment bypasses the customer energy manager (CEM) and is not HBES/BACS enabled (covered by other standards than the IEC 63402 series). This group EE publication is primarily intended to be used as an EE standard for the products mentioned in the scope, but is also intended to be used by TCs in the preparation of publications for products which are included in the boundary mentioned in the scope of this document. It has the status of a group energy efficiency publication in accordance with IEC Guide 118.
- Standard35 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-Aug-2025
- 03.100.70
- 27.015
- 29.020
- CLC/TC 205
IEC 63297:2025 provides a classification of NILM sensing devices for use in NILM systems, according to the state of the art of NILM technologies.
- Draft22 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-Aug-2025
- 17.220.20
- CLC/TC 85X
IEC 63267-3-61: 2025 defines the dimensional limits of an optical interface for reference connectors with 2,5 mm or 1,25 mm diameter cylindrical zirconia (ZrO2) ferrules necessary to meet specific requirements for fibre-to-fibre interconnection of non-angled polished multimode reference connections as defined in IEC 63267-2-2. Ferrule dimensions and features are contained in the IEC 61754 series of fibre optic connector interface standards. One grade of reference connector, Rm1, is defined in this document. The reference connector is terminated to restricted IEC 60793-2-10 using A1-OM2b to A1‑OM5b fibre in 850 nm band only. The geometrical dimensions and tolerances of the specified reference connector have been developed primarily to limit the variation in measured attenuation between multiple sets of reference connectors, and therefore to reduce the variation in measured attenuation between an arbitrarily chosen reference connector when mated with a connector in the field or factory. This first edition and the first edition of IEC 63267-2-2 cancel and replace the first edition of IEC 61755-6-2 published in 2018. This edition constitutes a technical revision. The document includes the following significant technical changes with respect to the previous edition: a) Definition of a reference grade, Rm1 interface; b) Inclusion of A1-OM2b to A1-OM5b fibres; c) Updates to normative references; d) The addition of Annex A, which describes the attenuation test limits of reference grade Rm1 connectors to grade Bm connectors; e) A new Annex B that describes the allowable fibre undercut.
- Draft13 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-Aug-2025
- 33.180.20
- CLC/TC 86BXA
IEC 60931-2:2025 applies to capacitors according to IEC 60931-1 and gives the requirements for the ageing test and destruction test for these capacitors.
- Standard12 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-Aug-2025
- 29.120.99
- 31.060.70
- 2014/35/EU
- M/511
- CLC/SR 33
IEC 63267-3-81: 2025 defines the dimensional limits of an optical interface for reference connectors with rectangular ferrules necessary to meet specific requirements for fibre-to-fibre interconnection of non-angled polished multimode reference connectors with rectangular ferrules intended to be used for attenuation measurements as defined in IEC 63267‑2‑2. Ferrule dimensions and features are contained in the IEC 61754 series of fibre optic interface standards.One grade of reference connector is defined in this document. The reference connector is terminated to restricted IEC 60793-2-10 A1-OM2b to A1-OM5b fibre at 850 nm band only. The geometrical dimensions and tolerances of the specified reference connector have been developed primarily to limit the variation in measured attenuation between multiple sets of two reference connectors, and therefore to limit the variation in measured attenuation between randomly chosen reference connectors when mated with connectors in the field or factory.
- Draft17 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-Aug-2025
- 33.180.20
- CLC/TC 86BXA
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.