EN 50411-4-1:2019
(Main)Fibre management systems and protective housings to be used in optical fibre communication systems - Product specifications - Part 4-1: Passive optical street cabinet for category A
Fibre management systems and protective housings to be used in optical fibre communication systems - Product specifications - Part 4-1: Passive optical street cabinet for category A
This European Standard covers street cabinets for up to 1440 fibre connections for use in outside plant environments under category A according to EN 61753-1:Ed2. This document contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements of a fully installed passive optical fibre street cabinet, in order for it to be categorised as an EN standard product. The street cabinet is a housing containing modular fibre management systems with splice trays for various fibre separation levels and connector mounting plates. The street cabinet may contain one or more of the following: storage and/or routing of cable; through-box/uncut fibre, cable storage; connectors passive optical devices.
LWL-Spleißkassetten und -Muffen für die Anwendung in LWL-Kommunikationssystemen - Produktnormen - Teil 4-1: Passiver Straßenverteilerschrank für die Kategorie A
1 Anwendungsbereich 1.1 Produktdefinition Dieses Dokument behandelt passive Straßen-Verteilerschränke zur Verwendung in Außenanlagen unter Kategorie A nach EN 61753-1. Dieses Dokument enthält die maßbezogenen, optischen, mechanischen und umgebungsbezogenen Anforderungen an das Betriebsverhalten eines installierten passiven Straßen-Verteilerschranks, um dieses Produkt als ein Produkt nach einer Europäischen Norm einstufen zu können. Der Straßen-Verteilerschrank ist ein Schutzgehäuse, das ein modulares Fasermanagementsystem mit Spleißkassetten für unterschiedliche Fasertrennungsebenen und Steckverbinder-Montageplatten enthält. Der Straßen-Verteilerschrank darf enthalten: – Ablage und Führung für Fasern und Kabel; – Ablage für Kabel(-schleifen) mit ungeschnittener Faser; – Spleißkassetten; – Adapter und Steckverbinder; – passive optische Bauteile (optische Leistungsteiler und Wellenlängenmultiplexer). Straßen-Verteilerschränke können außerdem aktive optische Bauteile enthalten (Verstärker, Wandler, Stromversorgungen), diese Anwendungen sind jedoch nicht Teil dieses Dokuments. 1.2 Betriebsumgebung Die ausgewählten Prüfungen, zusammen mit Schärfegrad und Dauer, sind repräsentativ für oberirdische Anlagen im Freien, festgelegt in EN 61753-1, Kategorie A: Oberirdische Umgebung. 1.3 Zuverlässigkeit Obwohl die erwartete Betriebsdauer des Produkts in dieser Umgebung 20 Jahre beträgt, garantiert die Übereinstimmung mit diesem Dokument nicht die Zuverlässigkeit des Produkts. Diese sollte unter Verwendung eines anerkannten Programms zur Bewertung der Zuverlässigkeit vorausgesagt werden. 1.4 Qualitätssicherung Übereinstimmung mit diesem Dokument garantiert nicht die Fertigungskonsistenz des Produkts. Diese sollte mit einem anerkannten Qualitätssicherungsprogramm sichergestellt werden. 1.5 Zulässige Faser- und Kabeltypen Diese Norm für Straßen-Verteilerschränke erlaubt die Verwendung von Einmodenfasern nach EN 60793-2-50 und A1-OM1- und A1-OM5-Mehrmodenfasern nach EN 60793-2-10 und sie eignet sich für alle LWL-Kabel der Normenreihe EN 60794 mit ihren verschiedenen Faserfassungsvermögen, Typen und Konstruktionen, solange ihre Befestigung im Schrank nicht dem Mindestbiegeradius von Faser oder Kabel widerspricht.
Systèmes de gestion des fibres et enveloppes de protection à utiliser dans les systèmes de communication par fibres optiques - Spécifications de produits - Partie 4-1: Armoire située dans un environnement urbain pour fibres optiques passives, pour la catégorie A
1.1 Définition du produit La présente Norme européenne couvre les armoires situées dans un environnement urbain pour fibres optiques passives destinées à être utilisées dans des installations extérieures pour la catégorie A conformément à l'EN 61753-1. Le présent document contient les exigences de performances dimensionnelles, optiques, mécaniques et environnementales applicables à une armoire située dans un environnement urbain pour fibres optiques passives installée afin d'être classée comme un produit conforme à une Norme européenne. L'armoire située dans un environnement urbain est une enveloppe de protection qui contient des systèmes de gestion des fibres modulaires avec des plateaux d'épissures de différents niveaux de séparation de fibres et des plaques de montage des connecteurs. L'armoire située dans un environnement urbain peut contenir un ou plusieurs des éléments suivants: - élément pour le stockage et le cheminement des fibres et des câbles; - élément pour le stockage de câbles et fibres non découpés (en boucle); - plateau d'épissures; - raccords et connecteurs; - composants optiques passifs (séparateurs de puissance optique et multiplexeurs par répartition en longueurs d'onde). Les armoires situées dans un environnement urbain peuvent également contenir des composants optiques actifs (amplificateurs, convertisseurs, alimentations), mais ces applications ne font pas partie du présent document. 1.2 Environnement de fonctionnement Les essais sélectionnés combinés aux sévérités et aux durées sont représentatifs d'une installation extérieure pour des environnements au-dessus du niveau du sol définis par l'EN 61753-1 Catégorie A: environnement aérien. 1.3 Fiabilité Bien que l'espérance de vie en service anticipée du produit dans cet environnement soit de 20 ans, la conformité à la présente Norme européenne ne garantit pas la fiabilité du produit. Il convient que celle-ci soit prédite en utilisant un programme reconnu d'évaluation de la fiabilité. 1.4 Assurance de la qualité La conformité à la présente Norme européenne ne garantit pas la cohérence de fabrication du produit. Il convient qu'elle soit maintenue en utilisant un programme reconnu d'assurance de la qualité. 1.5 Types de fibres et câbles autorisés La présente norme applicable aux armoires situées dans un environnement urbain concerne les fibres unimodales conformes à l'EN 60793-2-50, les fibres multimodales conformes à l'EN 60793-2-10 A1a et A1b et tous les câbles à fibres optiques des séries EN 60794 avec différentes capacités de fibres, différents types et différentes conceptions tant que l'installation dans l'armoire ne remet pas en cause le rayon de courbure minimal de la fibre ou du câble.
Sistemi za upravljanje z optičnimi vlakni in zaščitna ohišja za optične komunikacijske sisteme - Specifikacije izdelka - 4-1. del: Pasivna optična ulična omarica za kategorijo A
Ta evropski standard zajema ulične omarice za do 1440 optičnih povezav za uporabo v okoljih zunanjih napeljav iz kategorije A v skladu s standardom EN 61753-1:Ed2.
Ta dokument vsebuje začetne dimenzijske, optične, mehanske in okoljske funkcionalne zahteve, ki jih mora na začetku življenjske dobe izpolnjevati v celoti nameščena ulična omarica s pasivnimi optičnimi vlakni, da se lahko kategorizira kot izdelek v skladu s standardom EN.
Ulična omarica je ohišje, ki vsebuje modularne sisteme za upravljanje optičnih elementov s pladnjem s spojnicami za različne ravni ločevanja vlaken in ploščami za namestitev konektorjev. Ulična omarica lahko vsebuje eno ali več naslednjih stvari:
shrambo in/ali traso za kable;
vlakna za omarico/nerezana vlakna, shrambo kablov;
konektorje
pasivne optične naprave.
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2019
Sistemi za upravljanje z optičnimi vlakni in zaščitna ohišja za optične
komunikacijske sisteme - Specifikacije izdelka - 4-1. del: Pasivna optična ulična
omarica za kategorijo A
Fibre management systems and protective housings to be used in optical fibre
communication systems - Product specifications - Part 4-1: Passive optical street cabinet
for category A
LWL-Spleißkassetten und -Muffen für die Anwendung in LWL-Kommunikationssystemen
- Produktnormen - Teil 4-1
Organiseurs et boîtiers de fibres à utiliser dans les systèmes de communication par
fibres optiques - Spécifications de produits - Partie 4-1
Ta slovenski standard je istoveten z: EN 50411-4-1:2019
ICS:
31.240 Mehanske konstrukcije za Mechanical structures for
elektronsko opremo electronic equipment
33.180.20 Povezovalne naprave za Fibre optic interconnecting
optična vlakna devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN 50411-4-1
NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2019
ICS 33.180.20; 33.180.99
English Version
Fibre management systems and protective housings to be used
in optical fibre communication systems - Product specifications -
Part 4-1: Passive optical street cabinet for category A
Organiseurs et boîtiers de fibres à utiliser dans les LWL-Spleißkassetten und -Muffen für die Anwendung in
systèmes de communication par fibres optiques - LWL-Kommunikationssystemen - Produktnormen - Teil 4-1
Spécifications de produits - Partie 4-1
This European Standard was approved by CENELEC on 2019-05-20. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 50411-4-1:2019 E
Contents
European foreword . 4
1 Scope . 6
1.1 Product definition . 6
1.2 Operating environment . 6
1.3 Reliability . 6
1.4 Quality assurance . 6
1.5 Allowed fibre and cable types . 6
2 Normative references . 7
3 Terms, definitions and abbreviations. 8
3.1 Terms and definitions . 8
3.2 Abbreviations . 11
4 Description . 11
4.1 Optical fibre street cabinet . 11
4.2 Cable sealing . 14
4.3 Cable anchoring . 14
4.4 Fibre management system (FMS) . 14
4.5 Patchcords and pigtails . 15
4.6 Adapters . 15
4.7 Passive optical components . 15
4.8 Materials . 15
4.9 Marking and identification . 15
5 Variants . 16
6 Dimensional requirements . 18
7 Tests . 19
7.1 Sample size . 19
7.2 Test sample preparation . 19
7.2.1 Sealing performance test samples . 19
7.2.2 Optical performance test samples . 19
7.3 Test and measurement methods . 20
7.4 Test sequence . 20
7.5 Pass/fail criteria . 20
8 Test report . 21
9 Performance requirements . 21
9.1 Dimensional and marking requirements . 21
9.2 Sealing, optical and appearance acceptance criteria . 22
9.3 Mechanical sealing performance requirements . 23
9.4 Environmental sealing performance requirements . 26
9.5 Mechanical optical performance requirements . 27
9.6 Environmental optical performance requirements . 28
9.7 Material requirements . 28
Annex A (informative) Fibre details for test sample . 29
Annex B (informative) Sample size and product sourcing requirements . 30
Annex C (informative) Families of fibre management systems covered in this standard . 31
Annex D (informative) Dimensions of FMS for multiple elements and multiple ribbon . 32
Annex E (informative) Dimensions of S type fibre management system for single circuit, single
element and single ribbon . 33
Annex F (informative) Adapter, plug and cable assembly connector dimensions . 35
Bibliography . 36
European foreword
This document (EN 50411-4-1:2019) has been prepared by CLC/TC 86BXA “Fibre optic interconnect,
passive and connectorised components”.
The following dates are fixed:
• latest date by which this document has to be (dop) 2020-05-20
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards (dow) 2022-05-20
conflicting with this document have to be
withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Fibre management systems and protective housings to be used in optical fibre communication systems –
Product specifications
Part 4-1: Passive optical street cabinet for category A
Description Typical installation configuration Typical mounting options
Street Cabinet Outdoor Fibre Distribution Cabinet On the ground
Typical fibre management configurations
- Direct spliced fibres with and without branching devices
- Interconnect with and without branching devices
- Cross-connect with and without branching devices
Operating service environments
Applications:
Optical fibre cable networks EN 61753-1 category A
For outdoor above ground (aerial) applications
Modular adapter plates for the following connectors
Connector type Adapter size Standard
SC Simplex or duplex EN 61754-4
LC Simplex or duplex EN 61754-20
LSH Simplex or Duplex EN 61754-15
LF3 Simplex or Duplex EN 61754-28
MPO Simplex EN 61754-7
Fibre separation levels in Fibre Management System
Single circuit (1, 2 or 4 fibre splices per tray),
Single ribbon (1 ribbon splice per tray),
Single element (6, 8 or 12 fibre splices per tray),
Multiple ribbon (12 ribbon splices per tray)
Multiple element (up to 144 fibre splices per tray)
Street cabinet sizes and dimensions
Maximum outline dimensions
Maximum
Maximum
(mm)
connections
Size fibre splice
(adapters)
capacity
W H D
capacity
A 288 216 500 1 000 400
B
576 432 800 1 000 400
C 768 576 1 300 1 200 400
D 1 024 768 1 300 1 500 400
E 1 296 972 1 900 1 500 400
F 1 728 1 296 1 900 1 800 400
1 Scope
1.1 Product definition
This document covers passive optical fibre street cabinets for use in outside plant environments under
category A according to EN 61753-1.
This document contains the dimensional, optical, mechanical and environmental performance
requirements of an installed passive optical fibre street cabinet, in order for it to be categorised as an
European standard product.
The street cabinet is a protective housing containing a modular fibre management system with splice
trays for various fibre separation levels and connector mounting plates. The street cabinet may contain
one or more of the following:
– storage and routing of fibre and cable;
– uncut (looped) fibre and cable storage;
– splice trays;
– adapters and connectors;
– passive optical components (optical power splitters and wavelength division multiplexers).
Street cabinets can also contain active optical components (amplifiers, converters, power supplies),
but these applications are not part of this document.
1.2 Operating environment
The tests selected, combined with the severity and duration, are representative of outside plant above
ground environments defined by EN 61753-1 Category A: Aerial environment.
1.3 Reliability
Whilst the anticipated service life expectancy of the product in this environment is 20 years,
compliance with this document does not guarantee the reliability of the product. This should be
predicted using a recognised reliability assessment programme.
1.4 Quality assurance
Compliance with this document does not guarantee the manufacturing consistency of the product. This
should be maintained using a recognised quality assurance programme.
1.5 Allowed fibre and cable types
This street cabinet standard allows EN 60793-2-50 single-mode fibres and EN 60793-2-10 A1-OM1 to
A1-OM5 multimode fibres to be used and is suitable for all EN 60794 series optical fibre cables with
their various fibre capacities, types and designs as long as fitting in the cabinet does not contravene
the minimum bend radius.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
...