ETSI EN 300 386 V1.3.3 (2005-04)
Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements
Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements
REN/ERM-EMC-224-c1
Elektromagnetna združljivost in zadeve v zvezi z radijskim spektrom (ERM) – Oprema za telekomunikacijsko omrežje – Zahteve za elektromagnetno združljivost (EMC)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-marec-2006
Elektromagnetna združljivost in zadeve v zvezi z radijskim spektrom (ERM) –
Oprema za telekomunikacijsko omrežje – Zahteve za elektromagnetno združljivost
(EMC)
Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication
network equipment; ElectroMagnetic Compatibility (EMC) requirements
Ta slovenski standard je istoveten z: EN 300 386 Version 1.3.3
ICS:
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
Candidate Harmonized European Standard (Telecommunications series)
Electromagnetic compatibility
and Radio spectrum Matters (ERM);
Telecommunication network equipment;
ElectroMagnetic Compatibility (EMC) requirements
2 ETSI EN 300 386 V1.3.3 (2005-04)
Reference
REN/ERM-EMC-224-c1
Keywords
EMC, network, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, please send your comment to one of the following services:
http://portal.etsi.org/chaircor/ETSI_support.asp
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2005.
All rights reserved.
TM TM TM
DECT , PLUGTESTS and UMTS are Trade Marks of ETSI registered for the benefit of its Members.
TM
TIPHON and the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members.
TM
3GPP is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners.
ETSI
3 ETSI EN 300 386 V1.3.3 (2005-04)
Contents
Intellectual Property Rights.6
Foreword.6
1 Scope.7
2 References.8
3 Definitions and abbreviations.11
3.1 Definitions.11
3.2 Abbreviations.12
4 Installation environment.13
5 Immunity: test methods.13
5.1 Electrostatic discharge.13
5.2 Electrical fast transients/burst.13
5.3 Surges.14
5.3.1 Outdoor signal line ports.14
5.3.2 Indoor signal line ports .14
5.3.3 AC power ports.14
5.4 Immunity to continuous conducted signals .14
5.4.1 Low frequency ( ≤ 150 kHz).14
5.4.2 Radio frequency (> 150 kHz) .14
5.4.2.1 AC power port.14
5.4.2.2 DC power port.14
5.4.2.3 Signal line port.15
5.5 Immunity to radiated electromagnetic fields .15
5.6 Immunity to power supply disturbances: AC and DC power ports.15
5.6.1 Test of immunity to low frequency disturbances: AC power ports .15
6 Emission: test methods.15
6.1 AC power port.15
6.2 DC power port.15
6.3 Telecommunication Port.16
6.4 Radiated emission.16
7 Test levels and limits.17
7.1 Emission.17
7.1.1 Enclosure port, Radiated electromagnetic field emissions.17
7.1.2 AC ports.17
7.1.2.1 Conducted emissions.17
7.1.2.2 Current harmonics.17
7.1.2.3 Voltage fluctuations.17
7.1.3 DC ports; Conducted emissions.17
7.1.4 Telecommunication ports; Conducted emissions.17
7.2 Immunity.18
7.2.1 Equipment operating in telecommunication centres .18
7.2.1.1 Telecommunication centres, enclosure port.18
7.2.1.2 Telecommunication centres, ports for outdoor signal lines.19
7.2.1.3 Telecommunication centres, ports for indoor signal lines.20
7.2.1.4 Telecommunication centres, AC power ports .20
7.2.1.5 Telecommunication centres, DC power ports .21
7.2.2 Equipment operating in locations other than telecommunication centres.21
7.2.2.1 Other than telecommunication centres, enclosure port .21
7.2.2.2 Other than telecommunication centres, ports for outdoor signal lines .22
7.2.2.3 Other than telecommunication centres, ports for indoor signal lines .22
7.2.2.4 Other than telecommunication centres, AC power ports.23
7.2.2.5 Other than telecommunication centres, DC power ports.23
ETSI
4 ETSI EN 300 386 V1.3.3 (2005-04)
8 General test configuration.24
9 General operational conditions during testing.24
9.1 Equipment configuration.24
9.2 Operation of multimedia network equipment.25
10 General immunity conditions.25
10.1 General performance criteria.25
11 Switching equipment specific requirements.26
11.1 Test configuration.26
11.2 Operational conditions.27
11.2.1 Emission.27
11.2.2 Immunity.27
11.3 Specific immunity performance criteria.27
11.3.1 Digital port performance criteria .27
11.3.1.1 Performance criterion A (continuous phenomena).27
11.3.1.2 Performance criterion B (transient phenomena).28
11.3.1.3 Performance criterion C (interruptions) .28
11.3.2 Analogue port performance criteria .28
11.3.2.1 Performance criterion A (continuous phenomena).28
11.3.2.2 Performance criterion B (transient phenomena).28
11.3.2.3 Performance criterion C (interruptions) .28
12 Transmission equipment specific requirements .28
12.1 Test configuration.28
12.2 Operational conditions.29
12.2.1 Emission.29
12.2.2 Immunity.29
12.3 Specific immunity performance criteria.29
12.3.1 Digital signal ports.29
12.3.1.1 Performance criterion A (continuous phenomena).30
12.3.1.2 Performance criterion B (transient phenomena).30
12.3.1.3 Performance criterion C (interruptions) .30
12.3.2 Analogue voice frequency signal ports.30
12.3.2.1 Performance criterion A (continuous phenomena).30
12.3.2.2 Performance criterion B (transient phenomena).30
12.3.3 SDH and PDH interfaces .30
12.3.3.1 Tributary and aggregate interfaces.30
12.3.4 ISDN interfaces.31
12.3.4.1 Primary rate access ISDN interfaces.31
12.3.4.2 Network termination NT1 for ISDN "U" interfaces.31
12.3.4.3 Basic access ISDN interfaces.31
12.3.5 Analogue interfaces.31
12.3.5.1 Trunk interfaces and leased line interfaces .31
12.3.5.2 Subscriber interfaces.31
12.3.6 V.10, V.11, V.24, V.28, V.36, X.24 and similar V.- and X.- series interfaces .31
12.3.7 Ethernet and packet-data interfaces .31
12.3.7.1 Performance criterion A (continuous phenomena).31
12.3.7.2 Performance criterion B (transient phenomena).31
12.3.8 Service and maintenance interfaces .31
12.3.9 Synchronization interfaces.32
12.3.9.1 Performance criterion A (continuous phenomena).32
12.3.9.2 Performance criterion B (transient phenomena).32
12.3.10 Remote alarm interfaces .32
12.3.10.1 Performance criterion A (continuous phenomena).32
12.3.10.2 Performance criterion B (transient phenomena).32
13 Digital Subscriber Line (DSL) Access Systems.32
13.1 Test configuration.32
13.2 Operational conditions.33
13.2.1 Immunity.33
13.3 Specific Immunity performance criteria.33
ETSI
5 ETSI EN 300 386 V1.3.3 (2005-04)
13.3.1 Performance Criteria A (continuous phenomena).33
13.3.2 Performance Criteria B (transient phenomena).34
13.3.3 Performance Criteria C (interruptions) .34
14 Power supply equipment specific conditions .34
14.1 Test configuration.34
14.2 Operational conditions.35
14.2.1 Emission.35
14.2.2 Immunity.35
14.3 Specific immunity performance criteria.35
14.3.1 Alternating current secondary interface.36
14.3.1.1 Performance criterion A (continuous phenomena).36
14.3.1.2 Performance criterion B (transient phenomena).36
14.3.2 Direct current secondary interface .36
14.3.2.1 Performance criterion A (continuous phenomena).36
14.3.2.2 Performance criterion B (transient phenomena).37
14.3.3 Control/signal interface.37
14.3.4 Tertiary supply interface.37
15 Supervisory equipment specific conditions.37
15.1 Test configuration.37
15.2 Operational conditions.38
15.3 Specific immunity and resistibility performance criteria .38
15.3.1 Performance criterion A (continuous phenomena) .38
15.3.2 Performance criterion B (transient phenomena) .39
Annex A (normative): Surges: test method for ports of signal lines remaining within the
building .40
A.1 Test set-up for ports with ISDN interface .40
Annex B (informative): Evaluation of test results .43
Annex C (informative): Guidance on EMC performance requirements and methods of
measurement for RF ports (in the sense of EN 50083 series) of
multimedia network equipment .45
Annex D (informative): The EN title in the official languages .46
Annex E (informative): Bibliography.47
History .48
ETSI
6 ETSI EN 300 386 V1.3.3 (2005-04)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://webapp.etsi.org/IPR/home.asp).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This Candidate Harmonized European Standard (Telecommunications series) has been produced by ETSI Technical
Committee Electromagnetic compatibility and Radio spectrum Matters (ERM).
The present document has been produced by ETSI in response to a mandate from the European Commission issued
under Council Directive 98/34/EC [43] (as amended) laying down a procedure for the provision of information in the
field of technical standards and regulations.
The present document is intended to become a Harmonized Standard, the reference of which will be published in the
Official Journal of the European Communities referencing the Council Directive on the approximation of the laws of
the Member States relating to electromagnetic compatibility ("the EMC Directive") (89/336/EEC [41] as amended).
National transposition dates
Date of latest announcement of this EN (doa): 31 July 2005
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 January 2006
Date of withdrawal of any conflicting National Standard (dow): 31 January 2006
ETSI
7 ETSI EN 300 386 V1.3.3 (2005-04)
1 Scope
The present document covers the EMC requirements for equipment intended to be used within a telecommunications
network (as defined in clause 3). Examples of such equipment are:
• Switching equipment. Such equipment includes:
- local telephone exchanges;
- remote switching concentrators;
- international switches;
- telex switches;
- network packet switches.
• General purpose equipment, which is used as a part of a switching system, may be covered by the scope of
other standards. For such equipment, if those other standards fully cover all the requirements of the present
document, no further requirements are necessary. Switching equipment can also contain transmission
functions, and this has to be recognized during testing.
• Non-radio transmission equipment and ancillary equipment. Such equipment includes:
- multiplexers;
- line equipment and repeaters, e.g. equipment for:
- Synchronous Digital Hierarchy (SDH);
- Plesiochronous Digital Hierarchy (PDH);
- Asynchronous Transfer Mode (ATM);
such as:
- Digital Cross Connect systems;
- network terminations;
- transmission equipment used in the access network like XDSL.
• Power supply equipment. Such equipment includes:
- central power plant;
- end of suite power supplies;
- uninterruptible power supplies;
- stabilized AC power supplies;
- and other dedicated telecommunication network power supplies;
but excludes equipment which is uniquely associated with or integrated in other equipment.
ETSI
8 ETSI EN 300 386 V1.3.3 (2005-04)
• Supervisory equipment. Such equipment includes:
- network management equipment;
- operator access maintenance equipment;
- traffic measurement systems;
- line test units;
- functional test units.
The function of supervision may either be performed by independent equipment or form part of other
telecommunication equipment. If the function of supervision forms part of a telecommunication equipment, the
performance may be evaluated simultaneously with other functions (such as switching and transmission) during EMC
testing.
The environmental classification used in the present document refers to TR 101 651 [42].
The requirements of the present document have been selected to ensure an adequate level of immunity for the apparatus
covered by the scope of the present document. The levels do not, however, cover extreme cases which may occur at any
location but with a low probability of occurrence. In special cases, situations may arise where the levels of disturbance
may exceed the immunity test levels specified in the present document. In these instances, special mitigation measures
may have to be employed.
Equipment for cabled distribution systems intended only for television and sound signals as defined in EN 50083-2 [3]
and optical amplifiers as defined in ITU-T Recommendations G.661 [23] and G.662 [24] are outside the scope of the
present document.
2 References
The following documents contain provisions which, through reference in this text, constitute provisions of the present
document.
• References are either specific (identified by date of publication and/or edition number or version number) or
non-specific.
• For a specific reference, subsequent revisions do not apply.
• For a non-specific reference, the latest version applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
[1] CISPR 16-1: "Specification for radio disturbance and immunity measuring apparatus and methods;
Part 1: Radio disturbance and immunity measuring apparatus".
[2] EN 50082-1 (1997): "Electromagnetic compatibility - Generic immunity standard -
Part 1: Residential, commercial and light industry".
[3] EN 50083-2 (1995): "Cable networks for television signals, sound signals and interactive
services - Part 2: Electromagnetic compatibility for equipment".
[4] EN 55022 (1998): "Information technology equipment - Radio disturbance characteristics - Limits
and methods of measurement".
[5] EN 61000-3-2 (2000): "Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for
harmonic current emissions (equipment input current up to and including 16 A per phase)".
[6] EN 61000-3-3 (1995): "Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of
voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for
equipment with rated current <= 16 A per phase and not subject to conditional connection".
ETSI
9 ETSI EN 300 386 V1.3.3 (2005-04)
[7] EN 61000-4-2: "Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement
techniques - Electrostatic discharge immunity test".
[8] EN 61000-4-3: "Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement
techniques - Radiated, radio-frequency, electromagnetic field immunity test".
[9] EN 61000-4-4: "Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement
techniques - Electrical fast transient/burst immunity test".
[10] EN 61000-4-5: "Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement
techniques - Surge immunity test".
[11] EN 61000-4-6: "Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement
techniques - Immunity to conducted disturbances, induced by radio-frequency fields".
[12] EN 61000-4-11: "Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement
techniques - Voltage dips, short interruptions and voltage variations immunity tests".
[13] Void
[14] ETSI ETS 300 011 (1998): "Integrated Services Digital Network (ISDN); Primary rate
user-network interface; Layer 1 specification and test principles".
[15] ETSI ETS 300 012 (1992): "Integrated Services Digital Network (ISDN); Basic user-network
interface; Layer 1 specification and test principles".
[16] ETSI ETS 300 132-1 (1996): "Equipment Engineering (EE); Power supply interface at the input to
telecommunications equipment; Part 1: Operated by alternating current (ac) derived from direct
current (dc) sources".
[17] ETSI ETS 300 132-2 (1996): "Equipment Engineering (EE); Power supply interface at the input to
telecommunications equipment; Part 2: Operated by direct current (dc)".
[18] ETSI ETS 300 166 (1993): "Transmission and Multiplexing (TM); Physical and electrical
characteristics of hierarchical digital interfaces for equipment using the 2 048 kbit/s - based
plesiochronous or synchronous digital hierarchies".
[19] ETSI ETS 300 232 (1993): "Transmission and Multiplexing (TM); Optical interfaces for
equipments and systems relating to the Synchronous Digital Hierarchy [ITU-T Recommendation
G.957 (1993), modified]".
[20] IEC 60050-161: "International Electrotechnical Vocabulary. Chapter 161: Electromagnetic
compatibility".
[21] IEC 60050-714: "International Electrotechnical Vocabulary - Chapter 714: Switching and
signalling in telecommunications".
[22] ISO/IEC 8802-3 (1996): "Information technology - Telecommunications and information
exchange between systems - Local and metropolitan area networks - Specific requirements -
Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and
physical layer specifications".
[23] ITU-T Recommendation G.661 (1998): "Definition and test methods for the relevant generic
parameters of optical amplifier devices and subsystems".
[24] ITU-T Recommendation G.662 (1998): "Generic characteristics of optical amplifier devices and
subsystems".
[25] ITU-T Recommendation G.712 (1996): "Transmission performance characteristics of pulse code
modulation channels".
[26] ITU-T Recommendation G.812 (1998): "Timing requirements of slave clocks suitable for use as
node clocks in synchronization networks".
[27] ITU-T Recommendation G.813 (1996): "Timing characteristics of SDH equipment slave
clocks (SEC)".
ETSI
10 ETSI EN 300 386 V1.3.3 (2005-04)
[28] ITU-T Recommendation G.958 (1994): "Digital line systems based on the synchronous digital
hierarchy for use on optical fibre cables".
[29] ITU-T Recommendation G.961 (1993): "Digital transmission system on metallic local lines for
ISDN basic rate access".
[30] ETSI EN 300 127: "Electromagnetic compatibility and Radio spectrum Matters (ERM); Radiated
emission testing of physically large telecommunication systems".
[31] ITU-T Recommendation O.41 (1994): "Psophometer for use on telephone-type circuits".
[32] ITU-T Recommendation O.150 (1996): "General requirements for instrumentation for
performance measurements on digital transmission equipment".
[33] ITU-T Recommendation Q.552 (1996): "Transmission characteristics at 2-wire analogue interfaces
of digital exchanges".
[34] ITU-T Recommendation V.10 (1993): "Electrical characteristics for unbalanced double-current
interchange circuits operating at data signalling rates nominally up to 100 kbit/s".
[35] ITU-T Recommendation V.11 (1996): "Electrical characteristics for balanced double-current
interchange circuits operating at data signalling rates up to 10 Mbit/s".
[36] ITU-T Recommendation V.24 (2000): "List of definitions for interchange circuits between Data
Terminal Equipment (DTE) and Data Circuit-terminating Equipment (DCE)".
[37] ITU-T Recommendation V.28 (1993): "Electrical characteristics for unbalanced double-current
interchange circuits".
[38] ITU-T Recommendation V.36 (1988): "Modems for synchronous data transmission using
60-108 kHz group band circuits".
[39] ITU-T Recommendation X.24 (1988): "List of definitions for interchange circuits between Data
Terminal Equipment (DTE) and Data Circuit-terminating Equipment (DCE) on public data
networks".
[40] ITU-T Recommendation X.25 (1996): "Interface between Data Terminal Equipment (DTE) and
Data Circuit-terminating Equipment (DCE) for terminals operating in the packet mode and
connected to public data networks by dedicated circuit".
[41] Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of the Member
States relating to electromagnetic compatibility.
[42] ETSI TR 101 651 (V1.1.1): "Electromagnetic compatibility and radio spectrum matters (ERM);
Classification of the electromagnetic environment conditions for equipment in telecommunication
networks".
[43] Directive 98/34/EC of the European Parliament and of the Council of 22 June 1998 laying down a
procedure for the provision of information in the field of technical standards and regulations.
[44] ITU-T Recommendation G.996.1 (1999): "Test procedures for digital subscriber line (DSL)
transceivers".
[45] ETSI TS 101 135 (V1.5.3): "Transmission and Multiplexing (TM); High bit-rate Digital
Subscriber Line (HDSL) transmission systems on metallic local lines; HDSL core specification
and applications for combined ISDN-BA and 2 048 kbit/s transmission".
[46] ETSI TS 101 524-1 (V1.1.1): "Transmission and Multiplexing (TM); Access transmission system
on metallic access cables; Symmetrical single pair high bit rate Digital Subscriber Line (SDSL);
Part 1: Functional requirements".
[47] ETSI TS 101 270-1 (V1.2.1): "Transmission and Multiplexing (TM); Access transmission systems
on metallic access cables; Very high speed Digital Subscriber Line (VDSL); Part 1: Functional
requirements".
ETSI
11 ETSI EN 300 386 V1.3.3 (2005-04)
3 Definitions and abbreviations
3.1 Definitions
For the purposes of the present document, the following terms and definitions apply. The definitions taken from the
IEC 60050-161 [20] have reference in parentheses.
AC secondary interface: output port of an AC power supply
AC secondary voltage: output of the AC power supply at the AC secondary interface
NOTE: The AC secondary voltage may be either:
- a stabilized AC supply derived from a DC primary supply (e.g. where the power supply is an
inverter); or
- derived from the AC primary supply (e.g. a stabilized power supply used where the quality of the
primary supply is not sufficient to feed telecommunication equipment).
burst (161-02-07): sequence of a limited number of distinct pulses or an oscillation of limited duration
connection: temporary association of transmission channels or telecommunication circuits, switching or other
functional units set up to provide for the transfer of information between two or more points in a telecommunication
network (IEC 60050-714)
continuous disturbance (161-02-11): electromagnetic disturbance the effects of which on a particular device or
equipment cannot be resolved into a succession of distinct effects
DC secondary interface: output port of a DC power supply
DC secondary voltage: output of the DC power supply at the DC secondary interface
The DC secondary voltage may be derived from the AC primary supply with or without a buffer battery.
duration (of a voltage change) (161-08-03): interval of time for the voltage to increase or decrease from the initial
value to the final value
duration (of a pulse): interval of time between the instants at which the instantaneous value of a pulse reaches 50 % of
the pulse magnitude for the first and last time
enclosure port: physical boundary of the Equipment Under Test (EUT) through which electromagnetic fields may
emanate or on which they may impinge
environment, environmental conditions: electromagnetic conditions external to the equipment, to which it is
subjected at a certain time
The environmental conditions comprise a combination of single environmental parameters and their severity.
environmental parameters: present one or more properties of the electromagnetic environment
immunity (to a disturbance) (161-01-20): ability of a device, equipment or system to perform without degradation in
the presence of an electromagnetic disturbance
impulsive disturbance (161-02-09): electromagnetic disturbance which, when incident on a particular device or
equipment, manifests itself as a succession of distinct pulses or transients
interface "A": terminals at which a power supply is connected to the telecommunications equipment
multimedia network equipment: multimedia network equipment containing broadcast and telecommunication
functions
nominal voltage: nominal value of voltage that designates the type of supply
normal service: service mode where telecommunications equipment operates within its specification
ETSI
12 ETSI EN 300 386 V1.3.3 (2005-04)
performance criterion: limits of acceptable behaviour of the equipment during and after the application of the
electromagnetic phenomenon
NOTE: Performance criteria A apply for continuous phenomena; performance criteria B and C apply for transient
phenomena; and performance criteria R apply for resistibility phenomena.
port: particular interface of the EUT with the external electromagnetic environment
power supply: power source (within the scope of EN 300 386) to which telecommunications equipment is intended to
be connected
primary supply: public mains or a locally generated AC or DC supply
pulse (161-02-02): abrupt variation of short duration of a physical quantity followed by a rapid return to the initial
value
Radio Frequencies (RF): frequency range above 150 kHz
rise time (of a pulse) (161-02-05): interval of time between the instants at which the instantaneous value of a pulse first
reaches a specified lower value and then a specified upper value
NOTE: Unless otherwise specified, the lower and upper values are fixed at 10 % and 90 % of the pulse
magnitude.
secondary supply: supply to the telecommunications equipment (e.g. racks or system blocks), derived from the
primary supply
surge (voltage) (161-08-11): transient voltage wave propagating along a line or a circuit and characterized by a rapid
increase followed by a slower decrease of the voltage
system block: functional group of equipment depending for its operation and performance upon the secondary power
supply
telecommunication network: network operated under a licence granted by a national telecommunications authority,
which provides telecommunications between Network Termination Points (NTPs) (i.e. excluding terminal equipment
beyond the NTPs)
tertiary supply: supply to the telecommunications equipment derived from the secondary supply
transient (adjective or noun) (161-02-01): pertaining to or designating a phenomenon or a quantity which varies
between two consecutive steady states during a time interval which is short compared with the timescale of interest
3.2 Abbreviations
For the purposes of the present document, the following abbreviations apply:
ADSL Asymmetric Digital Subscriber Line
AM Amplitude Modulation
ATM Asynchronous Transfer Mode
CPU Central Processing Unit
DC Direct Current
DLU Digital Line Unit
DSL Digital Subscriber Line
EMC ElectroMagnetic Compatibility
ESD Electrostatic Discharge
EUT Equipment Under Test
HDSL High bit-rate Digital Subscriber Line
LTG Line Trunk Group
NTPs Network Termination Points
PDH Plesiochronous Digital Hierarchy
PRBS Pseudo Random Bit Sequence
RF Radio Frequency
rms root-mean-square
SDH Synchronous Digital Hierarchy
ETSI
13 ETSI EN 300 386 V1.3.3 (2005-04)
SDSL Symmetrical single pair high bit rate Digital Subscriber Line
SN Switching Network
TLS Test Load Simulator
T /T Rise time (10 % to 90 %) and hold time (50 % to 50 %) of transient signal (see EN 61000-4-4)
r h
TS Traffic Simulator
U Voltage measured with a p
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...