Attachment requirements for Data Terminal Equipment (DTE) to connect to public networks that have physical and electrical network presentations based upon the ITU-T V-series of Recommendations

DEN/DTA-000002

Priključitvene zahteve za podatkovno terminalsko opremo (DTE) za priključevanje na javna omrežja, katerih fizične in električne lastnosti temeljijo na V-seriji priporočil ITU-T

General Information

Status
Published
Publication Date
24-Oct-1999
Current Stage
12 - Completion
Due Date
05-Nov-1999
Completion Date
25-Oct-1999
Mandate

Buy Standard

Standard
EN 301 401 V1.2.6:2004
English language
44 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.SULNOMXþHYDQMHAttachment requirements for Data Terminal Equipment (DTE) to connect to public networks that have physical and electrical network presentations based upon the ITU-T V-series of Recommendations33.050.01Telekomunikacijska terminalska oprema na splošnoTelecommunication terminal equipment in generalICS:Ta slovenski standard je istoveten z:EN 301 401 Version 1.2.6SIST EN 301 401 V1.2.6:2004en01-oktober-2004SIST EN 301 401 V1.2.6:2004SLOVENSKI
STANDARD



SIST EN 301 401 V1.2.6:2004



ETSI EN 301 401 V1.2.6 (1999-10)Candidate Harmonized European Standard (Telecommunications series)Attachment requirements for Data Terminal Equipment (DTE)to connect to public networks that have physicaland electrical network presentations based uponthe ITU-T V-series of RecommendationsSIST EN 301 401 V1.2.6:2004



ETSIETSI EN 301 401 V1.2.6 (1999-10)2ReferenceDEN/DTA-000002 (cz000is0.PDF)KeywordsPSPDN, X.21ETSIPostal addressF-06921 Sophia Antipolis Cedex - FRANCEOffice address650 Route des Lucioles - Sophia AntipolisValbonne - FRANCETel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16Siret N° 348 623 562 00017 - NAF 742 CAssociation à but non lucratif enregistrée à laSous-Préfecture de Grasse (06) N° 7803/88Internetsecretariat@etsi.frIndividual copies of this ETSI deliverablecan be downloaded fromhttp://www.etsi.orgIf you find errors in the present document, send yourcomment to: editor@etsi.frImportant noticeThis ETSI deliverable may be made available in more than one electronic version or in print. In any case of existing orperceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).In case of dispute, the reference should be the printing on ETSI printers of the PDF version kept on a specific networkdrive within ETSI Secretariat.Copyright NotificationNo part may be reproduced except as authorized by written permission.The copyright and the foregoing restriction extend to reproduction in all media.© European Telecommunications Standards Institute 1999.All rights reserved.SIST EN 301 401 V1.2.6:2004



ETSIETSI EN 301 401 V1.2.6 (1999-10)3ContentsIntellectual Property Rights.6Foreword.61Scope.72References.73Definitions and abbreviations.83.1Definitions.83.2Abbreviations.94Safety and EMC requirements.94.1Safety requirements.94.2EMC requirements.95Applicability of Standard.96Electrical, mechanical, and access control protocol requirements.106.1General characteristics.106.1.1Generator presentations.106.1.1.1Balanced generator.106.1.1.2Unbalanced generator.106.2Connector characteristics and contact number assignments.106.2.1 Attachment to a DCE interface presented on a 25-pole connector.106.2.1.1Connector.106.2.1.2Contact number assignments.106.2.2Attachment to a DCE interface presented on a 26-pole connector.116.2.2.1Connector.116.2.2.2Contact number assignments.116.2.3Attachment to a DCE interface presented on a 37-pole connector.116.2.3.1Connector.116.2.3.2Contact number assignments.116.2.4Attachment to a DCE interface presented on a 34-pole connector.116.2.4.1Connector.116.2.4.2Contact number assignments.126.2.5Attachment to a DCE interface presented on a 15-pole connector.126.2.5.1Connector.126.2.5.2Contact number assignments.126.2.6Attachment to a DCE interface presented on a 50-pole connector.126.2.6.1Connector.126.2.6.2Contact number assignments.126.3Electrical requirements.136.3.1Requirements for attachment to ITU-T Recommendation V.10 interchange circuits.136.3.1.1Generator open circuit output voltage.136.3.2Requirements for attachment to ITU-T Recommendation V.11 interchange circuits.136.3.2.1Generator open circuit output voltage.146.3.3Requirements for attachment to ITU-T Recommendation V.12 interchange circuits.146.3.3.1Generator open circuit output voltage.146.3.4Requirements for attachment to ITU-T Recommendation V.28 interchange circuits.156.3.4.1Generator open circuit output voltage.156.3.5Requirements for attachment to CCITT Recommendation V.35 interchange circuits.156.3.5.1Generator open circuit output voltage.156.3.6Requirements for attachment to ITU-T Recommendation V.36 interchange circuits.166.3.6.1Generator open circuit output voltage.167Test Specification.167.1Conditions of test.167.1.1Environment for tests.167.1.2Power supply limitations.16SIST EN 301 401 V1.2.6:2004



ETSIETSI EN 301 401 V1.2.6 (1999-10)47.1.3Test condition.177.1.4Test point.177.1.5Bit patterns.177.1.6Signal element timing.177.1.7Interchange circuits presentation.177.1.8Physical layer tests.177.1.8.1Verification of the electrical characteristics.177.1.8.2Identically implemented circuits.177.1.8.3Fixed state generators.187.2Test descriptions for connector characteristics and contact number assignments.187.2.125-pole connector.187.2.1.1Connector characteristics.187.2.1.2Contact number assignments.187.2.226-pole connector.187.2.2.1Connector characteristics.187.2.2.2Contact number assignments.187.2.2.2.1Connection to a DCE presenting ITU-T Recommendation V.10 or V.11 electricalcharacteristics.187.2.2.2.2Connection to a DCE presenting ITU-T Recommendation V.28 electrical characteristics.197.2.337-pole connector.197.2.3.1Connector characteristics.197.2.3.2Contact number assignments.197.2.434-pole connector.197.2.4.1Connector characteristics.197.2.4.2Contact number assignments.197.2.515-pole connector.197.2.5.1Connector characteristics.197.2.5.2Contact number assignments.207.2.650-pole connector.207.2.6.1Connector characteristics.207.2.6.2Contact number assignments.207.3Test descriptions for attachment to ITU-T Recommendation V.10 interchange circuits.207.3.1Generator characteristics.207.3.1.1Generator open circuit output voltage.207.4Test descriptions for attachment to ITU-T Recommendation V.11 interchange circuits.217.4.1Generator characteristics.217.4.1.1Generator open circuit output voltage.217.5Test descriptions for attachment to ITU-T Recommendation V.12 interchange circuits.227.5.1Generator characteristics.227.5.1.1Generator open circuit output voltage.227.6Test descriptions for attachment to ITU-T Recommendation V.28 interchange circuits.237.6.1Generator characteristics.237.6.1.1Generator open circuit output voltage.237.7Test descriptions for attachment to CCITT Recommendation V.35 interchange circuits.247.7.1Generator characteristics.247.7.1.1Generator open circuit output voltage.247.8Test case selection expression definition table.257.9Test case Index.26Annex A (normative):The Requirements Table (RT).28A.1Introduction to the RT.28A.2Format of the tables.28A.3Notations used in the RT.29A.3.1Status notations.29A.3.2Support answer notations.29A.4The Harmonized Standard Requirement Tables.29A.4.1Means of connection to the DCE.29A.4.2Connection to a DCE presenting an ISO 2110 (25-pole) connector.30SIST EN 301 401 V1.2.6:2004



ETSIETSI EN 301 401 V1.2.6 (1999-10)5A.4.3Connection to a DCE presenting an ISO/IEC 11569 (26-pole) connector.31A.4.4Connection to a DCE presenting an ISO 4902 (37-pole) connector.34A.4.5Connection to a DCE presenting an ISO 2593 (34-pole) connector.36A.4.6Connection to a DCE presenting an ISO 4903 (15-pole) connector.38A.4.7Connection to a DCE presenting an TIA/EIA-613 (50-pole) connector.40Annex B (normative):Physical layer implementation extra information for testing (PIXIT).42Bibliography.43History.44SIST EN 301 401 V1.2.6:2004



ETSIETSI EN 301 401 V1.2.6 (1999-10)6Intellectual Property RightsIPRs essential or potentially essential to the present document may have been declared to ETSI. The informationpertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be foundin SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respectof ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server(http://www.etsi.org/ipr).Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guaranteecan be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server)which are, or may be, or may become, essential to the present document.ForewordThis Candidate Harmonized European Standard (Telecommunications series) has been produced by ETSI ProjectDigital Terminals and Access (DTA).The present document has been produced by ETSI in response to a mandate from the European Commission issuedunder Council Directive 98/34/EC [4] (as amended) laying down a procedure for the provision of information in thefield of technical standards and regulations.The present document is intended to become a Harmonized Standard, the reference of which may be published in theOfficial Journal of the European Communities referencing the Council Directive 98/13/EC [3] on the approximation ofthe laws of the Member States concerning telecommunications terminal equipment, including the mutual recognition oftheir conformity ("the TTE Directive").Technical specifications relevant to the TTE Directive are given in annex A.National transposition datesDate of adoption of this EN:22 October 1999Date of latest announcement of this EN (doa):31 January 2000Date of latest publication of new National Standardor endorsement of this EN (dop/e):31 July 2000Date of withdrawal of any conflicting National Standard (dow):31 July 2000SIST EN 301 401 V1.2.6:2004



ETSIETSI EN 301 401 V1.2.6 (1999-10)71ScopeThe present document specifies the technical characteristics to be provided by terminal equipment to be connected topublic networks presented at an ITU-T Recommendations V.10 [10], V.11 [11] (including X.26 [21] and X.27 [22]),V.12 [12], V.24 [13]/V.28 [14], V.35 [15] or V.36 [16] interface regardless of data rate. The objective of the presentdocument is to ensure that no disturbance occurs to the public network.The present document contains the minimum set of requirements derived from the above set of ITU-TRecommendations and is applicable for connection to X.21 [18] leased line and circuit switched, X.21 bis [19] leasedlines, X.25, Frame Relay and SMDS plus any other public network service that may be presented on the same electricalinterfaces.NOTE:Not all of the above services are available in all countries.A test is given for each requirement in the present document, including measurement methods. Requirements apply atthe public network interface of the terminal equipment, which may be stimulated to perform the tests by additionalequipment if necessary.Terminal equipment may be subject to additional or alternative requirements depending on its functionality, in particularif it supports a service that is considered to be a justified case for regulation of terminal interworking via thetelecommunications network.2ReferencesThe following documents contain provisions which, through reference in this text, constitute provisions of the presentdocument.· References are either specific (identified by date of publication, edition number, version number, etc.) ornon-specific.· For a specific reference, subsequent revisions do not apply.· For a non-specific reference, the latest version applies.· A non-specific reference to an ETS shall also be taken to refer to later versions published as an EN with the samenumber.[1]Council Directive 73/23/EEC of February 1973 on the harmonization of the laws of the MemberStates relating to electrical equipment designed for use within certain voltage limits (Low VoltageDirective.[2]Council Directive 89/336/EECof 3 May 1989 on the approximation of the laws of Member Statesrelating to electromagnetic compatibility.[3]Council Directive 98/13/EEC of 12 February 1998 relating to telecommunications terminalequipment and satellite earth station equipment, including the mutual recognition of theirconformity.[4]Council Directive 98/34/EC of 22 June 1998 laying down a procedure for the provision ofinformation in the field of technical standards and regulations.[5]ISO 2110 (1980): "Information technology - Data communication - 25-pole DTE/DCE interfaceconnector and contact number assignments".[6]ISO 2593 (1984): "Information technology - Telecommunications and information exchangebetween systems - 34-pole DTE/DCE interface connector and contact number assignments".[7]ISO 4902 (1980): "Information technology - Data communication - 37-pole DTE/DCE interfaceconnector and contact number assignments".SIST EN 301 401 V1.2.6:2004



ETSIETSI EN 301 401 V1.2.6 (1999-10)8[8]ISO 4903 (1989): "Information technology - Data communication - 15-pole DTE/DCE interfaceconnector and contact number assignments".[9]ISO/IEC 11569 (1992): "Information technology - Telecommunications and information exchangebetween systems - 26-pole interface connector mateability dimensions and contact numberassignments".[10]ITU-T Recommendation V.10 (1993): "Electrical characteristics for unbalanced double-currentinterchange circuits operating at data signalling rates nominally up to 100 kbit/s".[11]ITU-T Recommendation V.11 (1996): " Electrical characteristics for balanced double-currentinterchange circuits operating at data signalling rates up to 10 Mbit/s".[12]ITU-T Recommendation V.12 (1995): "Electrical characteristics for balanced double-currentinterchange circuits for interfaces with data signalling rates up to 52 Mbit/s."[13]ITU-T Recommendation V.24: "List of definitions for interchange circuits between data terminalequipment (DTE) and data circuit-terminating equipment (DCE)".[14]ITU-T Recommendation V.28 (1993): "Electrical characteristics for unbalanced double-currentinterchange circuits".[15]CCITT Recommendation V.35 (1984): "Data transmission at 48 kilobits per second using60-108 kHz group band circuits - Appendix II Electrical characteristics for balanceddouble-current interchange circuits".[16]ITU-T Recommendation V.36: "Modems for synchronous data transmission using 60-108 kHzgroup band circuits".[17]ITU-T Recommendation X.2 (1996): " International data transmission services and optional userfacilities in public data networks and ISDNs".[18]ITU-T Recommendation X.21 (1992): "Interface between Data Terminal Equipment and DataCircuit-terminating Equipment for synchronous operation on public data networks".[19]ITU-T Recommendation X.21 bis: "Use on public data networks of Data Terminal Equipment(DTE) which is designed for interfacing to synchronous V-Series modems".[20]ITU-T Recommendation X.25 (1996): "Interface between Data Terminal Equipment (DTE) andData Circuit-terminating Equipment (DCE) for terminals operating in the packet mode andconnected to public data networks by dedicated circuit".[21]ITU-T Recommendation X.26: "see ITU-T Recommendation V.10".[22]ITU-T Recommendation X.27: "See ITU-T Recommendation V.11".[23]TIA/EIA-613: "High Speed Serial Interface for Data Terminal Equipment and Data Circuit-Terminating Equipment".3Definitions and abbreviations3.1DefinitionsFor the purposes of the present document, the following terms and definitions apply:ITU-T Recommendation X.25 [20] network: PSPDN network which offers a ITU-T Recommendation X.25 [20]DTE/DCE interface providing the (E) facilities for user classes of service 8-11 as defined inITU-T Recommendation X.2, [17].All other definitions are as given in the ITU-T series of Recommendations.SIST EN 301 401 V1.2.6:2004



ETSIETSI EN 301 401 V1.2.6 (1999-10)93.2AbbreviationsFor the purposes of the present document, the following abbreviations apply:acalternating currentdcdirect currentDCEData Circuit terminating EquipmentDTEData Terminal EquipmentEMCElectroMagnetic CompatibilityRTRequirements TableIUTImplementation Under TestPIXITProtocol Implementation eXtra Information for TestingPSPDNPacket Switched Public Data NetworkTBRTechnical Basis for RegulationTETerminal EquipmentVoopen-circuit generator voltage4Safety and EMC requirements4.1Safety requirementsThere are no safety requirements contained within the present document.NOTE:Safety requirements are imposed under the Low Voltage Directive (73/23/EEC) [1] and articles 5 (a) and5 (b) of Directive 98/13/EEC [3].4.2EMC requirementsThere are no EMC requirements contained within the present document.NOTE:General EMC requirements are imposed under EMC Directive (89/336/EEC) [2] and article 5 (c) ofDirective 98/13/EEC [3].5Applicability of StandardThe requirements in the present document are applicable to DTE intended to be connected to DCE interfaces on publicnetworks providing one or more of the following services:-circuit switched data transmission service;-packet switched data transmission service;-leased circuit data transmission service;-frame relay data transmission service, orany other service presented via an ITU-T V series interface.SIST EN 301 401 V1.2.6:2004



ETSIETSI EN 301 401 V1.2.6 (1999-10)106Electrical, mechanical, and access control protocolrequirementsThe requirements of this clause apply at the means of connection to the DCE.6.1General characteristics6.1.1Generator presentations6.1.1.1Balanced generatorIn the case of balanced terminal equipment generators, points A and B are defined as the two physical connections, onthe means provided for connection to the DCE, to which the output of a terminal generator is connected, and point C isthe physical connection on the means of connection to the DCE to which the terminal equipment signal ground mayoptionally be connected (see figure 2).6.1.1.2Unbalanced generatorIn the case of unbalanced terminal equipment generators, point A is defined as the physical connection on the meansprovided for connection to the DCE, to which the output of a terminal generator is connected, and point C is the physicalconnection on the means of connection to the DCE to which the signal ground associated with that generator isconnected.6.2Connector characteristics and contact number assignmentsThe means of connection to the DCE should conform to either subclauses 6.2.1, 6.2.2, 6.2.3, 6.2.4, 6.2.5 or 6.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.