DE/EE-01019-2-6

Inženiring opreme (EE) - Pogoji okolja in preskusi vplivov okolja za telekomunikacijsko opremo – Del 2-6: Specifikacija preskusov vplivov okolja - Ladijsko okolje

General Information

Status
Published
Publication Date
26-May-1994
Current Stage
12 - Completion
Due Date
28-Apr-1994
Completion Date
27-May-1994

Buy Standard

Standard
ETS 300 019-2-6:1999
English language
18 pages
world standards week 20% off
Preview
world standards week 20% off
Preview

e-Library read for
1 day

Standards Content (sample)

SLOVENSKI STANDARD
SIST ETS 300 019-2-6:1999
01-november-1999
Inženiring opreme (EE) - Pogoji okolja in preskusi vplivov okolja za
telekomunikacijsko opremo – Del 2-6: Specifikacija preskusov vplivov okolja -
Ladijsko okolje
Equipment Engineering (EE); Environmental conditions and environmental tests for

telecommunications equipment; Part 2-6: Specification of environmental tests; Ship

environments
Ta slovenski standard je istoveten z: ETS 300 019-2-6 Edition 1
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
SIST ETS 300 019-2-6:1999 en

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST ETS 300 019-2-6:1999
---------------------- Page: 2 ----------------------
SIST ETS 300 019-2-6:1999
EUROPEAN ETS 300 019-2-6
TELECOMMUNICATION May 1994
STANDARD
Source: ETSI TC-EE Reference: DE/EE-1019-2-6
ICS: 33.080
Environment, specification, equipment
Key words:
Equipment Engineering (EE);
Environmental conditions and environmental tests for
telecommunications equipment
Part 2-6: Specification of environmental tests
Ship environments
ETSI
European Telecommunications Standards Institute
ETSI Secretariat
F-06921 Sophia Antipolis CEDEX - FRANCE
Postal address:
650 Route des Lucioles - Sophia Antipolis - Valbonne - FRANCE
Office address:
c=fr, a=atlas, p=etsi, s=secretariat - secretariat@etsi.fr
X.400: Internet:
Tel.: +33 92 94 42 00 - Fax: +33 93 65 47 16

Copyright Notification: No part may be reproduced except as authorized by written permission. The copyright and the

foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1994. All rights reserved.
New presentation - see History box
---------------------- Page: 3 ----------------------
SIST ETS 300 019-2-6:1999
Page 2
ETS 300 019-2-6: May 1994

Whilst every care has been taken in the preparation and publication of this document, errors in content,

typographical or otherwise, may occur. If you have comments concerning its accuracy, please write to

"ETSI Editing and Committee Support Dept." at the address shown on the title page.

---------------------- Page: 4 ----------------------
SIST ETS 300 019-2-6:1999
Page 3
ETS 300 019-2-6: May 1994
Contents

Foreword .......................................................................................................................................................5

1 Scope ..................................................................................................................................................7

2 Normative references..........................................................................................................................7

3 Environmental test specifications........................................................................................................7

3.1 Specification T 6.1: Totally weatherprotected locations.......................................................8

3.2 Specification T 6.2: Partly weatherprotected locations ......................................................10

3.3 Specification T 6.3: Non-weatherprotected locations ........................................................12

3.4 Notes to tables 1 to 5.........................................................................................................16

Annex A (informative): Bibliography........................................................................................................17

History..........................................................................................................................................................18

---------------------- Page: 5 ----------------------
SIST ETS 300 019-2-6:1999
Page 4
ETS 300 019-2-6: May 1994
Blank page
---------------------- Page: 6 ----------------------
SIST ETS 300 019-2-6:1999
Page 5
ETS 300 019-2-6: May 1994
Foreword

This multi-part European Telecommunication Standard (ETS) has been produced by the Equipment

Engineering (EE) Technical Committee of the European Telecommunications Standards Institute (ETSI).

ETS 300 019 is concerned with environmental conditions and environmental tests for telecommunications

equipment and comprises two main parts, each with subdivisions:
- ETS 300 019-1: "Classification of environmental conditions".

Part 1 specifies different standardised environmental classes covering climatic and biological

conditions, chemically and mechanically active substances and mechanical conditions during

storage, transportation and in use.
- ETS 300 019-2: "Specification of environmental tests".

Part 2 specifies the recommended test severities and test methods for the different environmental

classes.

Part 2-0 forms a general overview of Part 2. This part, (Part 2-6), deals with ship environments.

---------------------- Page: 7 ----------------------
SIST ETS 300 019-2-6:1999
Page 6
ETS 300 019-2-6: May 1994
Blank page
---------------------- Page: 8 ----------------------
SIST ETS 300 019-2-6:1999
Page 7
ETS 300 019-2-6: May 1994
1 Scope

This European Telecommunication Standard (ETS) specifies test severities and methods for the

verification of the required resistibility of equipment according to the relevant environmental class.

The tests defined in Part 2-6 of this multi-part standard apply to the use of equipment installed

permanently or temporarily in ships and cover the environments and the vessels stated in

ETS 300 019-1-6 [1].
2 Normative references

This ETS incorporates by dated or undated reference, provisions from other publications. These

normative references are cited at the appropriate places in the text and the publications are listed

hereafter. For dated references, subsequent amendments to or revisions of any of these publications

apply to this ETS only when incorporated in it by amendment or revision. For undated references the latest

edition of the publication referred to applies.
[1] ETS 300 019-1-6: "Equipment Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment Part 1-6: Classification
of environmental conditions; Ship environments".
[2] IEC 68-2: "Basic environmental testing procedures. Part 2: Tests".
[3] ETS 300 019-2-0: "Equipment Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment Part 2-0: Specification of
environmental tests; Introduction".
3 Environmental test specifications

The detailed descriptions of the environmental conditions are given in Clauses 4 and 5 of

ETS 300 019-1-6 [1].
ETS 300 019-2-0 [3] forms a general overview of Part 2 of this ETS.

The equipment under test is assumed to be in its operational state throughout the test conditions

described in this Part unless otherwise stated. The required performance before, during and after the test

needs to be specified in the product specification. Input and load conditions of the equipment shall be

chosen to obtain full utilisation of the equipment under test. The heat dissipation shall be maximised,

except for the steady state, low temperature test, where it shall be minimised.
---------------------- Page: 9 ----------------------
SIST ETS 300 019-2-6:1999
Page 8
ETS 300 019-2-6: May 1994
3.1 Specification T 6.1: Totally weatherprotected locations

This specification applies to a totally weatherprotected use in ships excluding Warm Damp and Warm Damp Equable climates, see tables 1 and 4.

Table 1: Test specification T 6.1: Totally weatherprotected locations - climatic tests

Environmental parameter Environmental Environmental test specification T 6.1: Ship, totally

Class 6.1 weatherprotected locations

Type Parameter Detail parameter Characteristic Test severity Duration Reference Method

severity
low (°C) +5 +5 (4) 16 h IEC 68-2-1 Ab/Ad: Cold (3)

____________________________________________________________________________________________________________________________

high (°C) +40 +40 16 h IEC 68-2-2 Bb/Bd: Dry heat

____________________________________________________________________________________________________________________________

Air
temperature change air/water (°C) no

____________________________________________________________________________________________________________________________

surface high (°C) no
low (%) 10 (5)

______________________________________________________________________________________________________________

high; slow (%) 95 93 4 days IEC 68-2-56 Cb: Damp heat
relative temperature change (°C) +30 +30 steady state

______________________________________________________________________________________________________________

high; rapid (%) no
temperature change (°C)

____________________________________________________________________________________________________________________________

Humidity
absolute high; rapid (g/m)no
temperature change
Air speed (m/s) no
temperature high (°C) 30 none

_____________________________________________________________________________________________________________

low (°C) no

____________________________________________________________________________________________________________________________

Water intensity (mm/min) no
rain volume (m /min)
pressure (kPa)

____________________________________________________________________________________________________________________________

other sources velocity (m/s) no

____________________________________________________________________________________________________________________________

wetness no
Radiation solar (W/m)no

____________________________________________________________________________________________________________________________

heat (W/m)no
(continued)
---------------------- Page: 10 ----------------------
SIST ETS 300 019-2-6:1999

Table 1 (concluded): Test specification T 6.1: Totally weatherprotected locations - climatic tests

Environmental parameter Environmental Environmental test specification T 6.1: Ship, totally

Class 6.1 weatherprotected locations

Type Parameter- Detail parameter- Characteristic Test severity Duration Reference Method

severity
SO2 (mg/m ) 0,1 (1) none (2)

sulphur _____________________________________________________________________________________________________________ _

H S (mg/m ) 0,01 (1) none (2)

____________________________________________________________________________________________________________________________

sea salts negligible

chlorine ______________________________________________________________________________________________________________

HCl (mg/m ) 0,1 (1) none (2)

____________________________________________________________________________________________________________________________

Chemically
active NO (mg/m ) 0,1 (1) none (2)

substances nitrogen ______________________________________________________________________________________________________________

NH (mg/m ) 0,3 (1) none (2)

____________________________________________________________________________________________________________________________

hydrogen
fluoride HF (mg/m ) 0,003 (1) none (2)

____________________________________________________________________________________________________________________________

ozone O (mg/m ) 0,01 (1) none (2)
dust sedimentation negligible

___________________________________________________________________________________________________________________________ _

Mechanically
active sand in air no

____________________________________________________________________________________________________________________________

substances
soot deposit no
Flora and micro organisms negligible

_____________________________________________________________________________________________________________________________

Fauna
rodents, insects negligible

no = this condition does not occur in this class. (n) = NOTE (n = number of note), see subclause 3.4.

none = verification is required only in special cases.
Page 9
ETS 300 019-2-6: May 1994
---------------------- Page: 11 ----------------------
SIST ETS 300 019-2-6:1999
Page 10
ETS 300 019-2-6: May 1994
3.2 Specification T 6.2: Partly weatherprotected locations

This specification applies to use in ships excluding Cold Climate and extreme weather conditions, see tables 2, 4 and 5.

Table 2: Test specification T 6.2: Partly weatherprotected locations - climatic tests

Environmental parameter Environmental Environmental test specification T 6.2 : Ship, partly

Class 6.2 weatherprotected locations

Type Parameter Detail parameter Characteristic Test severity Duration Reference Method

severity
low (°C) -25 -25 (4) 16 h IEC 68-2-1 Ab/Ad: Cold (3)

___________________________________________________________________________________________________________________________

high (°C) +70 +70 or +85 (7) 16 h IEC 68-2-2 Bb/Bd: Dry heat

___________________________________________________________________________________________________________________________

change gradual (°C) -25/+40 -25/+40 5 cycles IEC 68-2-14 Nb: Change of
Air (°C/min) 3 3 (6) t = 3 h temperature

___________________________________________________________________________________________________________________________

temperature
change air/water (°C) +40/+5 none (8)

___________________________________________________________________________________________________________________________

surface high (°C) +70 none
low (%) 10 none (5)

_____________________________________________________________________________________________________________

relative high; slow (%) 95 93 4 days IEC 68-2-56 Cb: Damp heat
temperature change (°C) +45 +40 steady state

_____________________________________________________________________________________________________________

high; rapid (%) 95 none (5)
temperature change (°C) -25/+35

___________________________________________________________________________________________________________________________

Humidity
high; rapid (g/m)60
absolute temperature change (°C) +70/+15
(%) 90-100 6 cycles IEC 68-2-30 Db: Damp heat
(°C) +55 cyclic, variant 1
Air speed m/s 30 none (5)
temperature high (°C) +35 none (5)

_____________________________________________________________________________________________________________

low (°C) freezing point none (5)

___________________________________________________________________________________________________________________________

intensity (mm/min) 6
rain volume (m /min) 0,01 5 minutes IEC 68-2-18 Rb: Impacting water
pressure (kPa) 90 method 2.2

Water ___________________________________________________________________________________________________________________________

other sources velocity (m/s) 3 none (5)

___________________________________________________________________________________________________________________________

wetness wet surfaces none (9)
Radiation solar (W/m ) 1120 none (10) (11)

___________________________________________________________________________________________________________________________

heat (W/m ) 1200 none (10)
(continued)
---------------------- Page: 12 ----------------------
SIST ETS 300 019-2-6:1999
Table 2 (concluded): Test specification T 6.2: Par
...

Questions, Comments and Discussion