SmartM2M; Smart Appliances Ontology and Communication Framework Testing; Part 3: Test Suite Structure and Test Purposes (TSS & TP)

DTS/SmartM2M-103 268-3_SAP_TSS

General Information

Status
Published
Publication Date
06-Apr-2017
Technical Committee
Current Stage
12 - Completion
Due Date
16-Dec-2016
Completion Date
07-Apr-2017
Ref Project

Buy Standard

Standard
ETSI TS 103 268-3 V1.1.1 (2017-04) - SmartM2M; Smart Appliances Ontology and Communication Framework Testing; Part 3: Test Suite Structure and Test Purposes (TSS & TP)
English language
46 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

ETSI TS 103 268-3 V1.1.1 (2017-04)






TECHNICAL SPECIFICATION
SmartM2M;
Smart Appliances Ontology and Communication
Framework Testing;
Part 3: Test Suite Structure and Test Purposes (TSS & TP)

---------------------- Page: 1 ----------------------
2 ETSI TS 103 268-3 V1.1.1 (2017-04)



Reference
DTS/SmartM2M-103 268-3_SAP_TSS
Keywords
IoT, M2M, Smart Appliance, testing, TSS&TP
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the
print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
and microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.

© European Telecommunications Standards Institute 2017.
All rights reserved.

TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members.
TM
3GPP and LTE™ are Trade Marks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association.
ETSI

---------------------- Page: 2 ----------------------
3 ETSI TS 103 268-3 V1.1.1 (2017-04)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 4
1 Scope . 5
2 References . 5
2.1 Normative references . 5
2.2 Informative references . 5
3 Definitions and abbreviations . 5
3.1 Definitions . 5
3.2 Abbreviations . 6
4 Prerequisites and Test Configurations . 6
4.1 Test Configurations . 6
5 Test Suite Structure (TSS) . 7
5.1 Structure for SAP tests . 7
6 Test Purposes (TP) . 8
6.1 Introduction . 8
6.1.1 TP definition conventions . 8
6.1.2 TP Identifier naming conventions . 8
6.1.3 Rules for the behaviour description . 8
6.1.4 Sources of TP definitions . 8
6.1.5 Mnemonics for PICS reference . 9
6.2 Test purposes for SAP Testing . 10
6.2.1 SAREF . 10
Annex A (informative): Notification Testcases . 41
History . 46

ETSI

---------------------- Page: 3 ----------------------
4 ETSI TS 103 268-3 V1.1.1 (2017-04)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (https://ipr.etsi.org/).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This Technical Specification (TS) has been produced by ETSI Technical Committee Smart Machine-to-Machine
communications (SmartM2M).
The present document is part 3 of a multi-part deliverable covering Conformance test specifications for Smart
Appliances Ontology and Communication Framework Testing, as identified below:
Part 1: "Testing methodology";
Part 2: "Protocol Implementation Conformance Statement (PICS) pro forma";
Part 3: "Test Suite Structure and Test Purposes (TSS & TP)";
Part 4: "Abstract Test Suite (ATS) and Protocol Implementation eXtra Information for Testing (PIXIT)".
Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
ETSI

---------------------- Page: 4 ----------------------
5 ETSI TS 103 268-3 V1.1.1 (2017-04)
1 Scope
The present document provides the Test Suite Structure and Test Purposes (TSS & TP) for Conformance test
specifications for Smart Appliances testing as defined in ETSI TS 103 268-1 [3] and ETSI TS 118 115 [5] in
compliance with the relevant requirements and in accordance with the relevant guidance given in ISO/IEC 9646-7 [4].
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
https://docbox.etsi.org/Reference.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are necessary for the application of the present document.
[1] ETSI TS 103 264: "SmartM2M; Smart Appliances; Reference Ontology and oneM2M Mapping".
[2] ETSI TS 118 112: "oneM2M; Base Ontology (oneM2M TS-00012)".
[3] ETSI TS 103 268-1: "SmartM2M; Smart Appliances Ontology and Communication Framework
Testing; Part 1: Testing methodology".
[4] ISO/IEC 9646-7: "Information technology - Open Systems Interconnection - Conformance testing
methodology and framework - Part 7: Implementation Conformance Statements".
[5] ETSI TS 118 115: "oneM2M; Testing Framework (oneM2M TS-0015)".
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
Not applicable.
3 Definitions and abbreviations
3.1 Definitions
For the purposes of the present document, the terms and definitions given in ETSI TS 103 268-1 [3], in ETSI
TS 118 112 [2] and in ISO/IEC 9646-7 [4] apply.
ETSI

---------------------- Page: 5 ----------------------
6 ETSI TS 103 268-3 V1.1.1 (2017-04)
3.2 Abbreviations
For the purposes of the present document, the abbreviations given in ETSI TS 103 268-1 [3], ETSI TS 103 264 [1] and
ETSI TS 118 112 [2] and the following apply:
API Application Programming Interface
EUT Equipment Under Test
IFS Interoperable Features Statement
IUT Implementation Under Test
IWF InterWorking Function
PICS Protocol Implementation Conformance Statement
QE Qualified Equipment
RP Reference Point
SAP Smart Appliance
SUT System Under Test
TP Test Purpose
TSS Test Suite Structure
4 Prerequisites and Test Configurations
4.1 Test Configurations
TEST SYSTEM IUT
Mca
AE CSE

Figure 4.1-1: Test configuration 1 (CF01)
TEST SYSTEM IUT
AE
Mca
CSE
CSE
Mcc

Figure 4.1-2: Test configuration 2 (CF02)
ETSI

---------------------- Page: 6 ----------------------
7 ETSI TS 103 268-3 V1.1.1 (2017-04)
TEST SYSTEM IUT
Mca
CSE AE

Figure 4.1-3: Test configuration 3 (CF03)
5 Test Suite Structure (TSS)
5.1 Structure for SAP tests
Table 5.1-1 shows SAP Test Suite Structure (TSS) including its subgroups defined for conformance testing.
Table 5.1-1: TSS for oneM2M
Root Group Sub-group category
SAP SAREF Valid behaviour
  Valid behaviour
  Valid behaviour
  Valid behaviour
  Valid behaviour
  Valid behaviour

The test suite is structured as a tree with the root defined as SAP. The tree is of rank 3 with the first rank a Group, the
second a Sub-group and the third a Category. The third rank is the standard ISO conformance test categories.
ETSI

---------------------- Page: 7 ----------------------
8 ETSI TS 103 268-3 V1.1.1 (2017-04)
6 Test Purposes (TP)
6.1 Introduction
6.1.1 TP definition conventions
The TPs are defined by the rules shown in table 6.1.1-1.
Table 6.1.1-1: TP definition rules
TP Header
TP ID The TP ID is a unique identifier. It shall be specified according to the TP naming
conventions defined in clause 6.1.2.
Test objective Short description of test purpose objective according to the requirements from the base
standard.
Reference The reference indicates the sub-clauses of the reference standard specifications in
which the conformance requirement is expressed.
PICS Selection Reference to the PICS statement involved for selection of the TP. Contains a Boolean
expression.
TP Behaviour
Initial conditions The initial conditions define in which initial state the IUT has to be to apply the actual
TP. In the corresponding Test Case, when the execution of the initial condition does not
succeed, it leads to the assignment of an Inconclusive verdict.
Expected behaviour (TP Definition of the events, which are parts of the TP objective, and the IUT are expected
body) to perform in order to conform to the base specification. In the corresponding Test
Case, Pass or Fail verdicts can be assigned there.
Final conditions Definition of the events that the IUT is expected to perform or shall not perform,
according to the base standard and following the correct execution of the actions in the
expected behaviour above. In the corresponding Test Case, the execution of the final
conditions is evaluated for the assignment of the final verdict.

6.1.2 TP Identifier naming conventions
The identifier of the TP is built according to table 6.1.2-1.
Table 6.1.2-1: TP naming convention
Identifier: TP/////
= root
= group


= subgroup



= type of testing BV Valid Behaviour tests
 BI Invalid Syntax or Behaviour Tests
 BO Inopportune Behaviour
= sequential number 01 to 99

6.1.3 Rules for the behaviour description
The description of the TP is built according to ETSI TS 103 268-1 [3].
6.1.4 Sources of TP definitions
All TPs are specified according to ETSI TS 103 264 [1] and ETSI TS 118 112 [2].
ETSI

---------------------- Page: 8 ----------------------
9 ETSI TS 103 268-3 V1.1.1 (2017-04)
6.1.5 Mnemonics for PICS reference
To avoid an update of all TP tables when the PICS document is changed, table 6.1.5-1 introduce mnemonics name and
the correspondence with the real PICS item number.
Table 6.1.5-1: Mnemonics for PICS reference
Mnemonic PICS item
PICS_AE A.5.1/1 [1]
PICS_CONTAINER A.5.1/1 [1]
PICS_FLEXCONTAINER A.5.1/1 [1]
PICS_GENERIC_IWK_SERVICE A.5.1/1 [1]
A.5.1/1 [1]
PICS GENERIC_IWK_OP_INSTANCE
PICS_DEVICE A.5.2/1 [1]
PICS_FUNCTION A.5.3/1 [1]
PICS_ PROPERTY A.5.5/1 [1]
PICS_ COMMAND A.5.6/1 [1]
PICS_DEVICECATEGORY A.5.7/1 [1]
PICS_STATE A.5.8/1 [1]
PICS_TASK A.5.9/1 [1]
PICS_UNITOFMESURE A.5.10/1 [1]
PICS_COMMODITY A.5.11/1 [1]
PICS_BUILDINGOBJECT A.5.12/1 [1]
PICS_BUILDINGSPACE A.5.13/1 [1]
PICS_PROFILE A.5.14/1 [1]
PICS_FUNCTIONCATEGORY A.5.15/1 [1]
PICS_OBJECTPROPERTY A.5.16/1 [1]
PICS_DATATYPE A.5.17/1 [1]
PICS_OPERATION A.5.18/1 [1]
PICS_THING A.5.19/1 [1]
PICS_ASPECT A.5.20/1 [1]

ETSI

---------------------- Page: 9 ----------------------
10 ETSI TS 103 268-3 V1.1.1 (2017-04)
6.2 Test purposes for SAP Testing
6.2.1 SAREF
TP Id TP/SAP/SAREF/BV/001
Test objective Check that the IUT creates for an instantiation of a class of the Base Ontology a oneM2M
resource of type containing a descriptor attribute containing the
instantiated class in RDF data.
Reference ETSI TS 118 112 [2], clause 7.1.1.1
Config Id CF03
PICS Selection PICS_AE
Initial conditions with {
the CSE being in the "initial state" and
the IUT having an ontology instance containing an instantiation of a class of the Base
Ontology and
the IUT having privileges to perform CREATE operation

}
Expected behaviour Test events
when {
the IUT starts and registers
}
then {
the IUT sends a valid CREATE request containing
To set to address of resource and
Resource-Type set to and
From set to AE-ID and
Content containing
resource containing
descriptor attribute containing
RDF data of the instantiated class
}



ETSI

---------------------- Page: 10 ----------------------
11 ETSI TS 103 268-3 V1.1.1 (2017-04)
TP Id Class
TP/SAP/SAREF/BV/001_01 saref:Device
TP/SAP/SAREF/BV/001_02 saref:Door switch
TP/SAP/SAREF/BV/001_03 saref:Energy meter
TP/SAP/SAREF/BV/001_04 saref:Light switch
TP/SAP/SAREF/BV/001_05 saref:Meter
TP/SAP/SAREF/BV/001_06 saref:Sensor
TP/SAP/SAREF/BV/001_07 saref:Smoke sensor
TP/SAP/SAREF/BV/001_08 saref:Switch
TP/SAP/SAREF/BV/001_09 saref:Temperature sensor
TP/SAP/SAREF/BV/001_10 saref:Washing machine
TP/SAP/SAREF/BV/001_11 saref:Service
TP/SAP/SAREF/BV/001_12 saref:Switch on service
TP/SAP/SAREF/BV/001_13 saref:Function
TP/SAP/SAREF/BV/001_14 saref:Actuating function
TP/SAP/SAREF/BV/001_15 saref:On off function
TP/SAP/SAREF/BV/001_16 saref:Open close function
TP/SAP/SAREF/BV/001_17 saref:start stopfunction
TP/SAP/SAREF/BV/001_18 saref:Event function
TP/SAP/SAREF/BV/001_19 saref:Metering function
TP/SAP/SAREF/BV/001_20 saref:Sensing function
TP/SAP/SAREF/BV/001_21 saref:Command
TP/SAP/SAREF/BV/001_22 saref:Close command
TP/SAP/SAREF/BV/001_23 saref:Get command
TP/SAP/SAREF/BV/001_24 saref:Get current meter value command
TP/SAP/SAREF/BV/001_25 saref:Get meter data command
TP/SAP/SAREF/BV/001_26 saref:Get meter history command
TP/SAP/SAREF/BV/001_27 saref:Get sensing data command
TP/SAP/SAREF/BV/001_28 saref:Notify command
TP/SAP/SAREF/BV/001_29 saref:Off command
TP/SAP/SAREF/BV/001_30 saref:On command
TP/SAP/SAREF/BV/001_31 saref:Open command
TP/SAP/SAREF/BV/001_32 saref:Pause command
TP/SAP/SAREF/BV/001_33 saref:Set level command
TP/SAP/SAREF/BV/001_34 saref:Set absolute level command
TP/SAP/SAREF/BV/001_35 saref:Set relative level command
TP/SAP/SAREF/BV/001_36 saref:Start command
TP/SAP/SAREF/BV/001_37 saref:Step down command
TP/SAP/SAREF/BV/001_38 saref:Step up command
TP/SAP/SAREF/BV/001_39 saref:Stop command
TP/SAP/SAREF/BV/001_40 saref:Toggle command

ETSI

---------------------- Page: 11 ----------------------
12 ETSI TS 103 268-3 V1.1.1 (2017-04)
TP Id TP/SAP/SAREF/BV/002
Test objective Check that the IUT creates for an instantiation of a class of the Base Ontology a oneM2M
resource of type containing an Ontology-Ref attribute that identifies the
instantiated class.
Reference
ETSI TS 118 112 [2], clause 7.1.1.1
Config Id CF03
PICS Selection PICS_AE
Initial conditions with {
the CSE being in the "initial state" and

the IUT having an ontology instance containing
an instantiation of a class of the Base Ontology
the IUT having privileges to perform CREATE operation
}
Expected behaviour Test events
when {
the IUT starts and registers
}
then {
the IUT sends a valid CREATE request containing
To set to address of resource and
Resource-Type set to and
From set to AE-ID and
Content containing
resource containing
Ontology-Ref set to an URI that identifies the instantiated
class.
}

ETSI

---------------------- Page: 12 ----------------------
13 ETSI TS 103 268-3 V1.1.1 (2017-04)
TP Id Class
TP/SAP/SAREF/BV/002_01 saref:Device
TP/SAP/SAREF/BV/002_02 saref:Door switch
TP/SAP/SAREF/BV/002_03 saref:Energy meter
TP/SAP/SAREF/BV/002_04 saref:Light switch
TP/SAP/SAREF/BV/002_05 saref:Meter
TP/SAP/SAREF/BV/002_06 saref:Sensor
TP/SAP/SAREF/BV/002_07 saref:Smoke sensor
TP/SAP/SAREF/BV/002_08 saref:Switch
TP/SAP/SAREF/BV/002_09 saref:Temperature sensor
TP/SAP/SAREF/BV/002_10 saref:Washing machine
TP/SAP/SAREF/BV/002_11 saref:Service
TP/SAP/SAREF/BV/002_12 saref:Switch on service
TP/SAP/SAREF/BV/002_13 saref:Function
TP/SAP/SAREF/BV/002_14 saref:Actuating function
TP/SAP/SAREF/BV/002_15 saref:On off function
TP/SAP/SAREF/BV/002_16 saref:Open close function
TP/SAP/SAREF/BV/002_17 saref:start stopfunction
TP/SAP/SAREF/BV/002_18 saref:Event function
TP/SAP/SAREF/BV/002_19 saref:Metering function
TP/SAP/SAREF/BV/002_20 saref:Sensing function
TP/SAP/SAREF/BV/002_21 saref:Command
TP/SAP/SAREF/BV/002_22 saref:Close command
TP/SAP/SAREF/BV/002_23 saref:Get command
TP/SAP/SAREF/BV/002_24 saref:Get current meter value
command
TP/SAP/SAREF/BV/002_25 saref:Get meter data command
TP/SAP/SAREF/BV/002_26 saref:Get meter history command
TP/SAP/SAREF/BV/002_27 saref:Get sensing data command
TP/SAP/SAREF/BV/002_28 saref:Notify command
TP/SAP/SAREF/BV/002_29 saref:Off command
TP/SAP/SAREF/BV/002_30 saref:On command
TP/SAP/SAREF/BV/002_31 saref:Open command
TP/SAP/SAREF/BV/002_32 saref:Pause command
TP/SAP/SAREF/BV/002_33 saref:Set level command
TP/SAP/SAREF/BV/002_34 saref:Set absolute level command
TP/SAP/SAREF/BV/002_35 saref:Set relative level command
TP/SAP/SAREF/BV/002_36 saref:Start command
TP/SAP/SAREF/BV/002_37 saref:Step down command
TP/SAP/SAREF/BV/002_38 saref:Step up command
TP/SAP/SAREF/BV/002_39 saref:Stop command
TP/SAP/SAREF/BV/002_40 saref:Toggle command

ETSI

---------------------- Page: 13 ----------------------
14 ETSI TS 103 268-3 V1.1.1 (2017-04)
TP Id TP/SAP/SAREF/BV/003
Test objective Check that the IUT creates for an instantiation of a class of the Base Ontology a oneM2M
resource of type containing the instantiated Object Propertiy for which the
instantiated class is the domain class.
Reference
ETSI TS 118 112 [2], clause 7.1.1.1
Config Id CF03
PICS Selection PICS_AE, PICS_OBJECTPROPERTY
Initial conditions with {
the CSE being in the "initial state" and

the IUT having an ontology instance containing
an instantiation of a class of the Base Ontology and
the IUT having privileges to perform CREATE operation
}
Expected behaviour Test events
when {
the IUT starts and registers

}
then {
the IUT sends a valid CREATE request containing
To set to address of resource and
Resource-Type set to and
From set to AE-ID and
Content containing
resource containing
the instantiated Object Property for which the instantiated
class is the domain class.

TP Id Object Property
TP/SAP/SAREF/BV/003_01 saref:accomplishes
TP/SAP/SAREF/BV/003_02 saref:acts upon
TP/SAP/SAREF/BV/003_03 saref:consists of
TP/SAP/SAREF/BV/003_04 saref:contains
TP/SAP/SAREF/BV/003_05 saref:has category
TP/SAP/SAREF/BV/003_06 saref:has command
TP/SAP/SAREF/BV/003_07 saref:has consumption
TP/SAP/SAREF/BV/003_08 saref:has function
TP/SAP/SAREF/BV/003_09 saref:has input parameter
TP/SAP/SAREF/BV/003_10 saref:has meter reading
TP/SAP/SAREF/BV/003_11 saref:has meter reading time
TP/SAP/SAREF/BV/003_12 saref:has output parameter
TP/SAP/SAREF/BV/003_13 saref:has price
TP/SAP/SAREF/BV/003_14 saref:has production
TP/SAP/SAREF/BV/003_15 saref:has profile
TP/SAP/SAREF/BV/003_16 saref:has sensing range
TP/SAP/SAREF/BV/003_17 saref:has sensing time
TP/SAP/SAREF/BV/003_18 saref:has singular unit
TP/SAP/SAREF/BV/003_19 saref:has state
TP/SAP/SAREF/BV/003_20 saref:has threshold
TP/SAP/SAREF/BV/003_21 saref:has time
TP/SAP/SAREF/BV/003_22 saref:has typical consumption
TP/SAP/SAREF/BV/003_23 saref:is accomplished by
TP/SAP/SAREF/BV/003_24 saref:is category of
TP/SAP/SAREF/BV/003_25 saref:is command of
TP/SAP/SAREF/BV/003_26 saref:is located in
TP/SAP/SAREF/BV/003_27 saref:is measured in
TP/SAP/SAREF/BV/003_28 saref:is offered by
TP/SAP/SAREF/BV/003_29 saref:Is used for
TP/SAP/SAREF/BV/003_30 saref:offers
TP/SAP/SAREF/BV/003_31 saref:represents

ETSI

---------------------- Page: 14 ----------------------
15 ETSI TS 103 268-3 V1.1.1 (2017-04)
TP Id TP/SAP/SAREF/BV/004
Test objective Check that the IUT creates for an instantiation of a class of the Base Ontology a oneM2M
resource of type containing the instantiated Data Property for which the
instantiated class is the domain class.
Reference
ETSI TS 118 112 [2], clause 7.1.1.1
Config Id CF03
PICS Selection PICS_AE, PICS_OBJECTPROPERTY
Initial conditions with {
the CSE being in the "initial state" and

the IUT having an ontology instance containing
an instantiation of a class of the Base Ontology and
the IUT having privileges to perform CREATE operation
}
Expected behaviour Test events
when {
the IUT starts and registers
}
then {
the IUT sends a valid CREATE request containing
To set to address of resource and
Resource-Type set to semanticDescriptor and
From set to AE-ID and no
Name attribute and
Content containing
semanticDescriptor resource containing
the instantiated Data Propertiy for which the instantiated
class is the domain class.

TP Id Data Property
TP/SAP/SAREF/BV/004_01 saref:has description
TP/SAP/SAREF/BV/004_02 saref:has manufacturer
TP/SAP/SAREF/BV/004_03 saref:has meter reading type
TP/SAP/SAREF/BV/004_04 saref:has model
TP/SAP/SAREF/BV/004_05 saref:has name
TP/SAP/SAREF/BV/004_06 saref:has sensor type
TP/SAP/SAREF/BV/004_07 saref:has space type
TP/SAP/SAREF/BV/004_08 saref:has task
TP/SAP/SAREF/BV/004_09 saref:has value
TP/SAP/SAREF/BV/004_10 saref:is flexible
TP/SAP/SAREF/BV/004_11 saref:is interruption possible

ETSI

---------------------- Page: 15 ----------------------
16 ETSI TS 103 268-3 V1.1.1 (2017-04)
TP Id TP/SAP/SAREF/BV/005
Test objective Check that the IUT creates for an instantiation of a class of the Base Ontology a oneM2M
resource of type containing an instance of the resourceDescriptorLink
annotation property that contains the URI of the semanticDescriptor of the instance of the range
class.
Reference ETSI TS 118 112 [2], clause 7.1.1.1
Config Id CF03
PICS Selection
PICS_AE, PICS_OBJECTPROPERTY
Initial conditions with {
the CSE being in the "initial state" and

the IUT having an ontology instance containing
an instantiation of a class of the Base Ontology and
a range class of an object property instantiated in a different
resource that is different to the resource in which the domain class
is instantiated and
the IUT having privileges to perform CREATE operation
}
Expected behaviour Test events
when {
the IUT starts and registers
}
then {
the IUT sends a valid CREATE request containing
To set to address of resource and
Resource-Type set to semanticDescriptor and
From set to AE-ID and
Content containing
semanticDescriptor resource containing
an instance of the resourceDescriptorLink annotation
property that contains the URI of the semanticDescriptor of
the instance of the range class.

ETSI

---------------------- Page: 16 ----------------------
17 ETSI TS 103 268-3 V1.1.1 (2017-04)
TP Id Class
TP/SAP/SAREF/BV/005_01 saref:Device
TP/SAP/SAREF/BV/005_02 saref:Door switch
TP/SAP/SAREF/BV/005_03 saref:Energy meter
TP/SAP/SAREF/BV/005_04 saref:Light switch
TP/SAP/SAREF/BV/005_05 saref:Meter
TP/SAP/SAREF/BV/005_06 saref:Sensor
TP/SAP/SAREF/BV/005_07 saref:Smoke sensor
TP/SAP/SAREF/BV/005_08 saref:Switch
TP/SAP/SAREF/BV/005_09 saref:Temperature sensor
TP/SAP/SAREF/BV/005_10 saref:Washing machine
TP/SAP/SAREF/BV/005_11 saref:Service
TP/SAP/SAREF/BV/005_12 saref:Switch on service
TP/SAP/SAREF/BV/005_13 saref:Function
TP/SAP/SAREF/BV/005_14 saref:Actuating function
TP/SAP/SAREF/BV/005_15 saref:On off function
TP/SAP/SAREF/BV/005_16 saref:Open close function
TP/SAP/SAREF/BV/005_17 saref:start stopfunction
TP/SAP/SAREF/BV/005_18 saref:Event function
TP/SAP/SAREF/BV/005_19 saref:Metering function
TP/SAP/SAREF/BV/005_20 saref:Sensing function
TP/SAP/SAREF/BV/005_21 saref:Command
TP/SAP/SAREF/BV/005_22 saref:Close command
TP/SAP/SAREF/BV/005_23 saref:Get command
TP/SAP/SAREF/BV/005_24 saref:Get current meter value command
TP/SAP/SAREF/BV/005_25 saref:Get meter data command
TP/SAP/SAREF/BV/005_26 saref:Get meter history command
TP/SAP/SAREF/BV/005_27 saref:Get sensing data command
TP/SAP/SAREF/BV/005_28 saref:Notify command
TP/SAP/SAREF/BV/005_29 saref:Off command
TP/SAP/SAREF/BV/005_30 saref:On command
TP/SAP/SAREF/BV/005_31 saref:Open command
TP/SAP/SAREF/BV/005_32 saref:Pause command
TP/SAP/SAREF/BV/005_33 saref:Set level command
TP/SAP/SAREF/BV/005_34 saref:Set absolute level command
TP/SAP/SAREF/BV/005_35 saref:Set relative level command
TP/SAP/SAREF/BV/005_36 saref:Start command
TP/SAP/SAREF/BV/005_37 saref:Step down command
TP/SAP/SAREF/BV/005_38 saref:Step up command
TP/SAP/SAREF/BV/005_39 saref:Stop command
TP/SAP/SAREF/BV/005_40 saref:Toggle command

ETSI

---------------------- Page: 17 ----------------------
18 ETSI TS 103 268-3 V1.1.1 (2017-04)
TP Id TP/SAP/SAREF/BV/006
Test objective Check that the IUT creates for an instantiation of a Device class or subclass a
resource under .
Reference ETSI TS 118 112 [2], clause 7.1.1.2
Config Id CF03
PICS Selectio
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.