IEC 61784-3-8:2010
(Main)Industrial communication networks - Profiles - Part 3-8: Functional safety fieldbuses - Additional specifications for CPF 8
Industrial communication networks - Profiles - Part 3-8: Functional safety fieldbuses - Additional specifications for CPF 8
IEC 61784-3-8:2010(E) specifies a safety communication layer (services and protocol) based on CPF 8 of IEC 61784-1 and IEC 61158 Type 18. It identifies the principles for functional safety communications defined in IEC 61784-3 that are relevant for this safety communication layer.
General Information
Relations
Standards Content (Sample)
IEC 61784-3-8 ®
Edition 1.0 2010-06
INTERNATIONAL
STANDARD
colour
inside
Industrial communication networks – Profiles –
Part 3-8: Functional safety fieldbuses – Additional specifications for CPF 8
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 61784-3-8 ®
Edition 1.0 2010-06
INTERNATIONAL
STANDARD
colour
inside
Industrial communication networks – Profiles –
Part 3-8: Functional safety fieldbuses – Additional specifications for CPF 8
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
X
ICS 25.040.40; 35.100.05 ISBN 978-2-88910-980-7
– 2 – 61784-3-8 © IEC:2010(E)
CONTENTS
FOREWORD.5
INTRODUCTION.7
1 Scope.10
2 Normative references .10
3 Terms, definitions, symbols, abbreviated terms and conventions .11
3.1 Terms and definitions .11
3.1.1 Common terms and definitions .11
3.1.2 CPF 8: Additional terms and definitions .16
3.2 Symbols and abbreviated terms.16
3.2.1 Common symbols and abbreviated terms .16
3.2.2 CPF 8: Additional symbols and abbreviated terms .17
3.3 Conventions .17
4 Overview of FSCP 8/1 (CC-Link Safety™) .17
5 General .18
5.1 External documents providing specifications for the profile.18
5.2 Safety functional requirements .18
5.3 Safety measures .18
5.3.1 General .18
5.3.2 Sequence number .19
5.3.3 Time expectation .19
5.3.4 Connection authentication .20
5.3.5 Feedback message .20
5.3.6 Different data integrity assurance system .20
5.4 Safety communication layer structure .20
5.5 Relationships with FAL (and DLL, PhL) .21
5.5.1 Overview .21
5.5.2 Data types .21
6 Safety communication layer services .21
6.1 General .21
6.2 SASEs.21
6.2.1 M1 safety device manager class specification.21
6.2.2 S1 safety device manager class specification .22
6.3 SARs.22
6.3.1 M1 safety connection manager class .22
6.3.2 S1 safety connection manager class.22
6.4 Process data SAR ASEs.23
6.4.1 M1 safety cyclic transmission class specification .23
6.4.2 S1 safety cyclic transmission class specification.23
7 Safety communication layer protocol .24
7.1 Safety PDU format .24
7.1.1 General .24
7.1.2 Abstract syntax.24
7.1.3 Transfer syntax.26
7.2 State description .30
7.2.1 Overview .30
7.2.2 Idle.31
61784-3-8 © IEC:2010(E) – 3 –
7.2.3 FAL running.31
7.2.4 SCL running .32
7.2.5 Fail safe .32
7.2.6 Safety data transmission and processing.32
7.2.7 Forced termination .34
8 Safety communication layer management.34
8.1 General .34
8.2 Connection establishment and confirmation processing.35
8.3 Safety slave verification .35
8.3.1 General .35
8.3.2 Safety slave information verification process .35
8.3.3 Safety slave parameter transmission .35
9 System requirements.36
9.1 Indicators and switches .36
9.1.1 Switches.36
9.1.2 Indicators .36
9.2 Installation guidelines.37
9.3 Safety function response time .37
9.3.1 General .37
9.3.2 Time calculation .37
9.4 Duration of demands .39
9.5 Constraints for calculation of system characteristics.39
9.5.1 System characteristics.39
9.5.2 Residual error rate (Λ) .39
9.6 Maintenance.40
9.7 Safety manual .40
10 Assessment.41
Annex A (informative) Additional information for functional safety communication
profiles of CPF 8.42
A.1 Hash function calculation.42
A.2 … .42
Annex B (informative) Information for assessment of the functional safety
communication profiles of CPF 8 .43
Bibliography.44
Table 1 – Selection of the various measures for possible errors.19
Table 2 – M1 safety device manager attribute format .24
Table 3 – S1 safety device manager attribute format .24
Table 4 – M1 safety connection manager attribute format .24
Table 5 – S1 safety connection manager attribute format.25
Table 6 – M1 safety cyclic transmission attribute format .25
Table 7 – S1 safety cyclic transmission attribute format .26
Table 8 – M1 safety device manager attribute encoding.26
Table 9 – S1 safety device manager attribute encoding .27
Table 10 – M1 safety connection manager attribute encoding .27
Table 11 – S1 safety connection manager attribute encoding.27
– 4 – 61784-3-8 © IEC:2010(E)
Table 12 – M1 safety cyclic transmission attribute encoding .28
Table 13 – S1 safety cyclic transmission attribute encoding.29
Table 14 – Safety master monitor timer operation .33
Table 15 – Safety slave monitor timer operation .33
Table 16 – Safety data monitor timer operation.33
Table 17 – Details of connection establishment and confirmation processing.35
Table 18 – Details of slave information verification processing.35
Table 19 – Details of safety slave parameter transmission processing .36
Table 20 – Monitor LEDs .36
Table 21 – Safety function response time calculation.
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.