Interpretation sheet 2 - Amendment 2 - Household and similar electrical appliances - Safety - Part 2-24: Particular requirements for refrigerating appliances, ice-cream appliances and ice makers

Feuille d'interprétation 2 - Amendement 2 - Appareils électrodomestiques et analogues - Sécurité - Partie 2-24: Règles particulières pour les appareils de réfrigération, les sorbetières et les fabriques

General Information

Status
Published
Publication Date
29-Mar-2020
Current Stage
DELPUB - Deleted Publication
Completion Date
16-Sep-2020
Ref Project

Relations

Buy Standard

Standard
IEC 60335-2-24:2010/AMD2:2017/ISH2:2020 - Interpretation sheet 2 - Amendment 2 - Household and similar electrical appliances - Safety - Part 2-24: Particular requirements for refrigerating appliances, ice-cream appliances and ice makers Released:3/30/2020
English and French language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


IEC 60335-2-24:2010/AMD2:2017/ – 1 –

ISH2:2020  IEC 2020
INTERNATIONAL ELECTROTECHNICAL COMMISSION

____________
IEC 60335-2-24
Edition 7.0  2010-02
Amendment 2: 2017-04
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES –
SAFETY –
Part 2-24: Particular requirements for refrigerating appliances,
ice-cream appliances and ice makers

INTERPRETATION SHEET 2
This interpretation sheet has been prepared by subcommittee 61C: Safety of refrigeration
appliances for household and commercial use, of technical committee 61: Safety of household
and similar electrical appliances.
The text of this interpretation sheet is based on the following documents:
DISH Report on voting
61C/839/DISH 61C/853/RVDISH
Full information on the voting for the approval of this interpretation sheet can be found in the
report on voting indicated in the above table.

___________
SC 61C interpretation sheet on: Subclause 30.2 of IEC 60335-2-24:2010/AMD2:2017
Subclause 30.2 states:
"Add the following to the addition:
For accessible thermal insulation and non-metallic material on the external rear surfaces of an
appliance having an area exceeding 75 cm that is in direct contact with the thermal
insulation, compliance is checked by the test of 30.2.101."
ICS 97.040.30
IEC 60335-2-24:2010-02/AMD2:2017-04/ISH2:2020-03(en-fr)

– 2 – IEC 60335-2-24:2010/AMD2:2017/

ISH2:2020  IEC 2020
Question 1: Has this subclause to be interpreted as:

"Add the following to the addition:

For accessible thermal insulation and non-metallic material on the external rear surfaces of an

appliance having a total area exceeding 75 cm that is in direct contact with the thermal

insulation, compliance is checked by the test of 30.2.101."

Subclause 30.2.101, final bullet point states:

• "that has an area not exceeding 75 cm that is in direct contact with the thermal

insulation is not tested. "
Question 2: Has this bullet point to be interpreted as:
• "that has a total area not exceeding 75 cm that is in direct contact with the thermal
insulation is not tested. "
Answers:
Question 1 –
From Subclause 30.2 addition, the following materials shall be tested:
1) Accessible thermal insulation
2) Non-metallic material on the rear surface of the appliance having an area exceeding
that is in direct contact with the thermal insulation
75 cm
Small holes (< 3 mm ) in the outer case were not intended to be considered as “accessible
thermal insulation”. These small < 3 mm holes are much smaller than the test probe B, so
therefore the thermal insulation of 3 mm holes is automatically not considered as accessible
thermal insulation without additional evaluation.
When testing accessible thermal insulation, the test is intended to be performed by applying
the flame to the accessible thermal insulation on the end product.
Question 2 – See question 1.
IEC 60335-2-24:2010/AMD2:2017/ – 3 –

ISH2:2020  IEC 2020
COMMISSION ÉLECTROTECHNIQUE INTERNATIO
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.