IEC 61784-5-2:2007
(Main)Industrial communication networks - Profiles - Part 5-2: Installation of fieldbuses - Installation profiles for CPF 2
Industrial communication networks - Profiles - Part 5-2: Installation of fieldbuses - Installation profiles for CPF 2
It specifies the installation profiles for CPF 2 (CIP). The installation profiles are specified in the annexes. These annexes are read in conjunction with IEC 61918:2007.
General Information
Relations
Standards Content (Sample)
IEC 61784-5-2
Edition 1.0 2007-12
INTERNATIONAL
STANDARD
Industrial communication networks – Profiles –
Part 5-2: Installation of fieldbuses – Installation profiles for CPF 2
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 61784-5-2
Edition 1.0 2007-12
INTERNATIONAL
STANDARD
Industrial communication networks – Profiles –
Part 5-2: Installation of fieldbuses – Installation profiles for CPF 2
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
XG
ICS 35.100.05 25.040.40 ISBN 2-8318-9402-6
– 2 – 61784-5-2 © IEC:2007(E)
CONTENTS
FOREWORD.9
INTRODUCTION.11
1 Scope.12
2 Normative references .12
3 Terms, definitions and abbreviated terms .12
4 CPF 2: Overview of installation profiles .12
5 Installation profile conventions .13
6 Conformance to installation profiles.13
Annex A (normative) CP 2/1 (ControlNet™) specific installation profile .14
A.1 Installation profile scope.14
A.2 Normative references .14
A.3 Installation profile terms, definitions, and abbreviated terms.14
A.3.1 Terms and definitions .14
A.3.2 Abbreviated terms .14
A.3.3 Conventions for installation profiles .14
A.4 Installation planning .15
A.4.1 Introduction .15
A.4.2 Planning requirements.16
A.4.3 Network capabilities .17
A.4.4 Selection and use of cabling components .22
A.4.5 Cabling planning documentation.38
A.4.6 Verification of planning specification.38
A.5 Installation implementation .39
A.5.1 General requirements .39
A.5.2 Cable installation.39
A.5.3 Connector installation.40
A.5.4 Terminator installation .49
A.5.5 Device installation .49
A.5.6 Coding and labelling .51
A.5.7 Earthing and bonding of equipment and devices and shield cabling .51
A.5.8 As-implemented cabling documentation.52
A.6 Installation verification and installation acceptance test.53
A.6.1 Introduction .53
A.6.2 Installation verification.53
A.6.3 Installation acceptance test .55
A.7 Installation administration.57
A.8 Installation maintenance and installation troubleshooting .57
A.8.1 General .57
A.8.2 Maintenance.57
A.8.3 Troubleshooting.57
Annex B (normative) CP 2/2 (EtherNet/IP™) specific installation profile.62
B.1 Installation profile scope.62
B.2 Normative references .62
B.3 Installation profile terms, definitions, and abbreviated terms.62
B.3.1 Terms and definitions .62
B.3.2 Abbreviated terms .62
61784-5-2 © IEC:2007(E) – 3 –
B.3.3 Conventions for installation profiles .63
B.4 Installation planning .63
B.4.1 Introduction .63
B.4.2 Planning requirements.64
B.4.3 Network capabilities .64
B.4.4 Selection and use of cabling components .66
B.4.5 Cabling planning documenation .78
B.4.6 Verification of cabling planning specification.78
B.5 Installation implementation .79
B.5.1 General requirements .79
B.5.2 Cable installation.79
B.5.3 Connector installation.80
B.5.4 Terminator installation .81
B.5.5 Device installation .81
B.5.6 Coding and labelling .81
B.5.7 Earthing and bonding of equipment and devices and shield cabling .81
B.5.8 As-implemented cabling documentation.83
B.6 Installation verification and installation acceptance test.84
B.6.1 Introduction .84
B.6.2 Installation verification.84
B.6.3 Installation acceptance test .85
B.7 Installation administration.86
B.8 Installation maintenance and installation troubleshooting .86
Annex C (normative) CP 2/3 (DeviceNet™) specific installation profile.87
C.1 Installation profile scope.87
C.2 Normative references .87
C.3 Installation profile terms, definitions, and abbreviated terms.87
C.3.1 Terms and definitions .87
C.3.2 Abbreviated terms .87
C.3.3 Conventions for installation profiles .87
C.4 Installation planning .88
C.4.1 Introduction .88
C.4.2 Planning requirements.89
C.4.3 Network capabilities .90
C.4.4 Selection and use of cabling components .103
C.4.5 Cabling planning documentation. 112
C.4.6 Verification of cabling planning specification.112
C.5 Installation implementation .113
C.5.1 General requirements .113
C.5.2 Cable installation.113
C.5.3 Connector installation.115
C.5.4 Terminator installation .125
C.5.5 Device installation .126
C.5.6 Coding and labelling .129
C.5.7 Earthing and bonding of equipment and devices and shield cabling .129
C.5.8 As-implemented cabling documentation. 130
C.6 Installation verification and installation acceptance test. 130
C.6.1 Introduction .130
C.6.2 Installation verification.130
– 4 – 61784-5-2 © IEC:2007(E)
C.6.3 Installation acceptance test .133
C.7 Installation administration.134
C.8 Installation maintenance and installation troubleshooting . 134
C.8.1 General .134
C.8.2 Maintenance.134
C.8.3 Troubleshooting.134
C.8.4 Specific requirements for maintenance and troubleshooting . 134
Annex D (informative) Additional information .137
D.1 Network validation check sheet for CP 2/3 (DeviceNet) . 137
Bibliography.141
Table A.1 – Basic network characteristics for copper cabling not based on Ethernet
(ISO/IEC 8802-3) .21
Table A.2 – Allowable fibre lengths .21
Table A.3 – Power budgets for ControlNet fibre networks .21
Table A.4 – RG6 coaxial electrical properties.22
Table A.5 – RG6 coaxial physical parameters .23
Table A.6 – Cable type selection.23
Table A.7 – Information relevant to optical fibre cables .24
Table A.8 – Copper connectors for ControlNet .25
Table A.9 – Fibre connectors for fieldbus systems .25
Table A.10 – Separation from other circuits inside enclosures .34
Table A.11 – Pulling and bend radius for coaxial cables .39
Table A.12 – Bend radius for coaxial cables .39
Table A.13 – Spacing from other circuits inside and outside wire ways or conduit .40
Table A.14 – Separation from Category-1 conductors for coax cables inside enclosures.40
Table A.15 – Test matrix for BNC/TNC connectors.54
Table A.16 – Wave length and fibre types .57
Table A.17 – LED status table.59
Table A.18 – Repeater adapter and module diagnostic .59
Table A.19 – Repeater adapter indicator diagnostic .59
Table A.20 – Repeater module indicator .60
Table A.21 – Short and medium distance troubleshooting chart .60
Table A.22 – Long and extra long troubleshooting chart.61
Table B.1 – Network characteristics for balanced cabling based on Ethernet .65
Table B.2 – Network characteristics for optical fibre cabling.66
Table B.3 – Information relevant to balanced cable: fixed cables .66
Table B.4 – Information relevant to balanced cable: cords .67
Table B.5 – TCL limits for unshielded twisted-pair cabling .67
Table B.6 – ELTCTL limits for unshielded twisted-pair cabling .68
Table B.7 – Coupling attenuation limits for screened twisted-pair cabling.68
Table B.8 – 4 pair colour codes and pair assignment .68
Table B.9 – 2 pair colour codes and pair assignment .68
Table B.10 – Fibre type and bandwidth .69
61784-5-2 © IEC:2007(E) – 5 –
Table B.11 –Connectors for balanced cabling CPs based on Ethernet .69
Table B.12 – Industrial EtherNet/IP 8-way modular connector parameters .70
Table B.13 – Industrial EtherNet/IP M12-4 D-coding connector parameters .71
Table B.14 – Optical fibre connectors for fieldbus systems .71
Table B.15 – Supported fibre types.72
Table B.16 – Connector insertion loss.73
Table B.17 – Routing communications cabling in contiguous metallic pathways .77
Table B.18 – Parameters for balanced cables .79
Table B.19 – Parameters for silica optical fibre cables .79
Table C.1 – Basic network characteristics for copper cabling not based on Ethernet
(ISO/IEC-8802-3).91
Table C.2 – Cable trunk and drop lengths for CP 2/3 .91
Table C.3 – Summary of available current for trunk cables (CP 2/3).95
Table C.4 – Available current for thin cable drop lines .95
Table C.5 – Power supply specification for DeviceNet.96
Table C.6 – Power supply tolerance stack up for DeviceNet.96
Table C.7 – Current versus cable length for one power supply thick cable .98
Table C.8 – Current versus length for two power supplies.99
Table C.9 – Definition of equation variables .101
Table C.10 – Information relevant to copper cable: fixed cables.104
Table C.11 – Information relevant to copper cable: cords.104
Table C.12 – DeviceNet cables and connector support cross reference . 104
Table C.13 – DeviceNet cable profiles .105
Table C.14 – Copper connectors for non-Ethernet based fieldbus . 108
Table C.15 – Additional connectors for CP 2/3 (DeviceNet) . 108
Table C.16 – Parameters for balanced cables.113
Table C.17 – Wire colour code and function.118
Table C.18 – Auxiliary power cable colour code . 123
Table C.19 – Network power supply requirements.123
Table C.20 – Signal wire verification .131
Table C.21 – Shield to earth .132
Table C.22 – Connector pin out .133
Figure 1 – Standards relationships.11
Figure A.1 – Interconnection of CPF 2 networks .15
Figure A.2 – Overview of CPF 2 networks.16
Figure A.3 – Drop cable requirements.17
Figure A.4 – Placement of BNC/TNC plugs .18
Figure A.5 – Placement of terminators .18
Figure A.6 – Extending a network using repeaters .19
Figure A.7 – Extending a network using active star topology.19
Figure A.8 – Links.20
Figure A.9 – Extending the network beyond 99 nodes.20
– 6 – 61784-5-2 © IEC:2007(E)
Figure A.10 – Maximum allowable taps per segment.26
Figure A.11 – Example of repeaters in star configuration .28
Figure A.12 – Repeaters in parallel.29
Figure A.13 – Repeaters in combination series and parallel .29
Figure A.14 – Ring repeater.30
Figure A.15 – Installing bulkheads .31
Figure A.16 – Coaxial BNC and TNC terminators .32
Figure A.17 – Terminator placement in a segment .32
Figure A.18 – Redundant network icons.35
Figure A.19 – Redundant coax media .35
Figure A.20 – Redundant fibre media.35
Figure A.21 – Repeaters in series versus length difference for coax media.36
Figure A.22 – Repeaters in series versus length difference for fibre media .36
Figure A.23 – Example of redundant coax network with repeaters.37
Figure A.24 – Example of improper redundant node connection.37
Figure A.25 – Example tool kit for installing BNC connectors .41
Figure A.26 – Calibration of coaxial stripper.41
Figure A.27 – Coax PVC strip length detail .42
Figure A.28 – Memory cartridge and blade.43
Figure A.29 – Cable position.43
Figure A.30 – Locking the cable.43
Figure A.31 – Stripping the cable.44
Figure A.32 – Install the crimp ferrule .44
Figure A.33 – Cable preparation for PVC type cables .44
Figure A.34 – Cable preparation for FEP type cables.45
Figure A.35 – Strip guides .45
Figure A.36 – Using the flare tool.46
Figure A.37 – Expanding the shields.46
Figure A.38 – Install the centre pin .46
Figure A.39 – Crimping the centre pin.47
Figure A.40 – Installing the connector body .47
Figure A.41 – Installing the ferrule .47
Figure A.42 – Crimp tool .48
Figure A.43 – Sealed IP67 cable.48
Figure A.44 – Terminator placement .49
Figure A.45 – Mounting the taps .50
Figure A.46 – Mounting the tap assembly using the universal mounting bracket .50
Figure A.47 – Mounting the tap using tie wraps or screws.51
Figure A.48 – Redundant network icons.51
Figure A.49 – Network test tool.54
Figure A.50 – Shorting the cable to test for continuity .54
Figure A.51 – Testing fibre segments.56
Figure A.52 – Multi-fibre backbone cable housing .58
61784-5-2 © IEC:2007(E) – 7 –
Figure A.53 – Repeater adapter module.58
Figure A.54 – Short and medium distance fibre module LEDs .60
Figure A.55 – Long and extra long repeater module LEDs .61
Figure B.1 – Interconnection of CPF 2 networks .63
Figure B.2 – Peer to peer connections .65
Figure B.3 – The 8-way modular sealed jack & plug (plastic housing) .70
Figure B.4 – The 8-way modular sealed jack & plug (metal housing).70
Figure B.5 – M12-4 connectors .71
Figure B.6 – Simplex LC connector.72
Figure B.7 – Duplex LC connector .72
Figure B.8 – IP65/IP67 sealed duplex LC connector .72
Figure B.9 – M12-4 to 8-way modular bulkhead .74
Figure B.10 – The 8-way modular sealed jack & plug (plastic housing) .80
Figure B.11 – The 8-way modular sealed jack & plug (metal housing).80
Figure B.12 – M12-4 connectors .80
Figure B.13 – Wiring standard (connector back end).81
Figure B.14 – Earthing of cable shield .83
Figure B.15 – Open shield example .83
Figure C.1 – Interconnection of CPF 2 networks .88
Figure C.2 – Connection to generic cabling.89
Figure C.3 – DeviceNet cable system uses a trunk/drop line topology.90
Figure C.4 – Measuring the trunk length .92
Figure C.5 – Measuring the trunk and drop length.92
Figure C.6 – Measuring drop cable in a network with multiports .93
Figure C.7 – Removable device using open style connectors .93
Figure C.8 – Fixed connection using open style connector.94
Figure C.9 – Open style connector pin out .94
Figure C.10 – Open style connector pin out 10 position .94
Figure C.11 – Power supply sizing example .97
Figure C.12 – Current limit for thick cable for one power supply.98
Figure C.13 – Current for thick cable and two power supplies .99
Figure C.14 – Worst case scenario .100
Figure C.15 – Example using the lookup method .100
Figure C.16 – One power supply end connected .102
Figure C.17 – Segmenting power in the power bus .103
Figure C.18 – Segmenting the power bus using power taps . 103
Figure C.19 – Thick cable construction .113
Figure C.20 – Mid cable construction .114
Figure C.21 – Thin cable construction.114
Figure C.22 – Flat cable construction.114
Figure C.23 – Cable preparation .115
Figure C.24 – Connector assembly .115
Figure C.25 – Micro connector pin assignment.116
– 8 – 61784-5-2 © IEC:2007(E)
Figure C.26 – Mini connector pin assignment.116
Figure C.27 – Preparation of cable end.116
Figure C.28 – Shrink wrap installation.117
Figure C.29 – Wire preparation .117
Figure C.30 – Open-style connector (female) .117
Figure C.31 – Open style (male plug).117
Figure C.32 – Flat cable.118
Figure C.33 – Aligning the cable .119
Figure C.34 – Closing the assembly.119
Figure C.35 – Proper orientation of cable.119
Figure C.36 – Locking the assembly .119
Figure C.37 – Driving the IDC contacts in to the cable .120
Figure C.38 – End cap placement .120
Figure C.39 – End cap seated.121
Figure C.40 – End cap installation alternate side of cable .121
Figure C.41 – Flat cable IDC connectors.121
Figure C.42 – Installing the connectors .122
Figure C.43 – Cable wiring to open style terminals .122
Figure C.44 – Auxiliary power cable profile .123
Figure C.45 – Pin out auxiliary power connectors.123
Figure C.46 – Sealed terminator .125
Figure C.47 – Open-style terminator .126
Figure C.48 – Open-style IDC terminator .126
Figure C.49 – Sealed terminator IDC cable .126
Figure C.50 – Direct connection to the trunk .127
Figure C.51 – Wiring of open-style connector.127
Figure C.52 – Wiring of open-style 10-position connector . 127
Figure C.53 – Diagnostic temporary connections . 128
Figure C.54 – Thick cable preterminated cables (cord sets) . 128
Figure C.55 – Thin cable preterminated cables (cord sets). 129
61784-5-2 © IEC:2007(E) – 9 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
INDUSTRIAL COMMUNICATION NETWORKS – PROFILES
Part 5-2: Installation of fieldbuses – Installation profiles for CPF 2
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61784-5-2 has been prepared by subcommittee 65C: Industrial
networks, of IEC technical committee 65: Industrial process measurement, control and
automation.
This standard is to be used in conjunction with IEC 61918:2007.
The text of this standard is based on the following documents:
FDIS Report on voting
65C/471/FDIS 65C/482/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 61784-5 series, under the general title Industrial communication
networks – Profiles – Installation of fieldbuses, can be found on the IEC website.
– 10 – 61784-5-2 © IEC:2007(E)
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
61784-5-2 © IEC:2007(E) – 11 –
INTRODUCTION
This International Standard is one of a series produced to facilitate the use of communication
networks in industrial control systems.
IEC 61918:2007 (Ed. 1.0) provides the common requirements for the installation of
communication networks in industrial control systems. This installation profile standard
provides the installation profiles of the communication profiles (CP) of a specific
communication profile family (CPF) by stating which requirements of IEC 61918 fully apply
and, where necessary, by supplementing, modifying, or replacing the other requirements (see
Figure 1).
For general background on fieldbuses, their profiles, and relationship between the installation
profiles specified in this standard, see IEC/TR 61158-1.
Each CP installation profile is specified in a separate annex of this standard. Each annex is
structured exactly as the reference standard IEC 61918 for the benefit of the persons
representing the roles in the fieldbus installation process as defined in IEC 61918 (planner,
installer, verification personnel, validation personnel, maintenance personnel, administration
personnel). By reading the installation profile in conjunction with IEC 61918, these persons
immediately know which requirements are common for the installation of all CPs and which
are modified or replaced. The conventions used to draft this standard are defined in Clause 5.
The provision of the installation profiles in one standard for each CPF (e.g. IEC 61784-5-2 for
CPF 2), allows readers to work with standards of a convenient size.
DEDEDEDESSSSIIIIGGGGNNNN PPLLAANNINNINGNG,, E ETTC.C.
GGEENENERIC RIC
OFOFFFIICCE PE PRREMEMISISESES
CACABBLLIINNGG
ISISOO/IE/IECC 1180111801
ISISOO/IE/IECC
14763-14763-22
BEBETWTWEEEENN
AUTAUTOOMMAATTIOIONN ISISOO/IE/IECC 2470224702
ISISLLAANDNDSS
BEBETWTWEEEENN
IEIEC 61784C 61784--5 5
AUTAUTOOMMAATTIOIONN
IEIEC 619C 6191818
ININDDUUSSTTRRIIAALL PR PREMEMISISESES IEC 6IEC 61158 1158
serseriesies
ISISLLAANDNDSS
serseriesies
InInststallatallatioionn
anandd
prprofofiilleess
((CoCommmmonon
WITWITHHININ
IEC 617IEC 61784-84-1,1, - -22 ((SSelelectectiion +on +
rreequiquirreemmeentntss))
AUTAUTOOMMAATTIOIONN
Add/Add/ReReplpl//MMod)od)
ISI
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...