Amendment 57 - Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges

Amendement 57 - Culots de lampes et douilles ainsi que calibres pour le contrôle de l'interchangeabilité et de la sécurité - Partie 3: Calibres

General Information

Status
Published
Publication Date
30-Mar-2020
Technical Committee
Drafting Committee
Current Stage
PPUB - Publication issued
Start Date
17-Apr-2020
Completion Date
31-Mar-2020
Ref Project

Buy Standard

Standard
IEC 60061-3:1969/AMD57:2020 - Amendment 57 - Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges
English and French language
60 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NORME IEC
INTERNATIONALE
INTERNATIONAL 60061-3
STANDARD
AMENDEMENT 57
AMENDMENT 57
2020-03
Amendement 57
Culots de lampes et douilles ainsi que calibres

pour le contrôle de l'interchangeabilité

et de la sécurité –
Partie 3:
Calibres
Amendment 57
Lamp caps and holders together with

gauges for the control of interchangeability
and safety –
Part 3:
Gauges
Les feuilles de cet amendement sont à insérer dans
l'IEC 60061­3 (1969)
The sheets contained in this amendment are to be inserted
in IEC 60061­3 (1969)
 IEC 2020 Droits de reproduction réservés – Copyright - all rights reserved

International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch

NORME IEC
INTERNATIONALE
INTERNATIONAL 60061-3
STANDARD Edition 3.57
2020-03
Modifiée selon les compléments/Amended in accordance with supplements:

A(1970), B(1971), C(1971), D(1972), E(1972), F(1975),
G(1977), H(1980), J(1983), K(1987), L(1989), M(1991), N(1994),

P(1994), Q(1995), R(1996), S(1996), T(1996), U(1997),

et les amendements/amendments 20(1998) 21(1999), 22(1999), 23(2000),

24(2001), 25(2001), 26(2001), 27(2002), 28(2002), 29(2002), 30 (2003), 31(2003),
32(2003), 33(2004), 34(2004), 35(2005), 36(2006) 37(2006), 38(2007), 39(2009),
40(2009), 41(2010), 42(2010), 43(2011), 44(2011), 45(2011), 46(2012), 47(2013),

48(2013), 49(2014), 50(2015), 51(2015), 52(2016), 53(2017), 54(2017),

55(2018), 56(2019) et/and 57(2020)

Culots de lampes et douilles ainsi que calibres
pour le contrôle de l'interchangeabilité
et de la sécurité –
Partie 3:
Calibres
Lamp caps and holders together with
gauges for the control of interchangeability
and safety –
Part 3:
Gauges
 IEC 2020 Droits de reproduction réservés – Copyright - all rights reserved

Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch

SOMMAIRE CONTENTS
CALIBRES – SOMMAIRE PAR DÉSIGNATION GAUGES – CONTENTS BY DESIGNATION
Feuilles Sheet
Chanfreins sur les arêtes de calibres . 7006-1-3 Facets on gauge edges . 7006-1-3
Calibre «Entre» pour culots sur lampes "Go" gauge for caps on finished
terminées BA20d/s . 7006-2-3 lamps BA20d/s . 7006-2-3
Calibre d'acceptation pour culots B22d destinés à Acceptance gauge for B22d caps intended for
un enfilage automatique . 7006-3-1 automatic wire threading . 7006-3-1
Calibres «Entre» pour culots à deux broches G1.27, "Go" gauges for bi-pin caps G1.27, GX1.27,
GX1.27, GY1.3, G2.54, GX2.54, GY2.5, . 7006-4-2 GY1.3, G2.54, GX2.54, GY2.5, . 7006-4-2
Calibres pour vérifier l'insertion des culots dans Gauges for testing the insertion of caps
les douilles B15d, B22d & BY22d . 7006-4A-2 in lampholders B15d, B22d & BY22d . 7006-4A-2
Calibres pour vérifier la tenue des culots B15d Gauges for testing the retention of B15d and
et B22d dans la douille . 7006-4B-1 B22d caps in the holder . 7006-4B-1
Calibre «Entre» pour culot préfocus "Go" gauge for prefocus cap
PX26d, PY26d-1 PY26d-7 . 7006-5-3 PX26d, , PY26d-1 PY26d-7 . 7006-5-3
Calibre «Entre» et «N'Entre Pas» pour les languettes "Go" and "Not Go" gauge for the tabs of prefocus
du culot préfocus PX26 et PY26d . 7006-5A-2 cap PX26 and PY26d. 7006-5A-2
Calibre «N'Entre Pas» pour la dimension Mmin "Not Go" gauge for dimension Mmin of prefocus
du culot préfocus PX26, PY26d-1 to PY26d-7 . 7006-5B-3 cap PX26, PY26d-1 to PY26d-7 . 7006-5B-3
Calibre «Entre» pour douille "Go" gauge for lampholder
PX26d, PY26d-1 to PY26d-7 . 7006-5C-2 PX26d, PY26d-1 to PY26d-7 . 7006-5C-2
Calibre «Entre» pour culots sur lampes "Go" gauge for caps on finished
terminées Ell . 7006-6-1 lamps Ell . 7006-6-1
Calibre «A» pour la vérification de la réalité Plug gauge"A" for testing contact-
du contact dans les douilles Ell . 7006-6A-1 making in lampholders Ell . 7006-6A-1
Calibre «B» pour la vérification de la réalité Plug gauge"B" for testing contact-
du contact dans les douilles Ell . 7006-6B-1 making in lampholders Ell . 7006-6B-1
Calibre «Entre» pour culots EY10 . 7006-7-1 "Go" gauge for caps EY10 . 7006-7-1
Calibre «Entre» pour douilles EY10 . 7006-7A-1 "Go" gauge for lampholders EY10 . 7006-7A-1
Calibres «Entre» pour culots sur lampes terminées "Go" gauges for caps on finished lamps BAX9s,
BAX9s, BAY9s, BAU9s, BAUZ9s, BAW9s & BAZ9s 7006-9-3 BAY9s, BAU9s, BAUZ9s, BAW9s & BAZ9s . 7006-9-3
Calibres tampons pour douilles de lampes Plug gauges for lampholders
BAX9s, BAY9s, BAW9s & BAZ9s . 7006-9A-2 BAX9s, BAY9s, BAW9s & BAZ9s . 7006-9A-2
Calibres pour la vérification de la réalité du Gauges for testing contact-making
contact dans les douilles de lampes BAX9s, BAY9s, in lampholders BAX9s, BAY9s, BAW9s
BAW9s & BAZ9s . 7006-9B-2 & BAZ9s . 7006-9B-2
Calibres «N'Entre Pas» pour la vérification de la "Not Go" gauges for checking
non-interchangeabilité des culots dans les douilles non-interchangeability of caps in lampholders
BAX9s, BAY9s, BAU9s, BAUZ9s, BAW9s & BAZ9s 7006-9C-3
BAX9s, BAY9s, BAU9s, BAUZ9s, BAW9s & BAZ9s 7006-9C-3
Calibres «N'Entre Pas» pour culots sur lampes
"Not Go" gauges for caps on finished
terminées BA9, B15d, B22d & BY22d . 7006-10-8
lamps BA9, B15d, B22d & BY22d . 7006-10-8
Calibres «Entre» pour culots sur lampes terminées
"Go" gauges for caps on finished lamps
B15d, & B22d . 7006-11-9
B15d & B22d . 7006-11-9
Calibre «Entre» pour culots sur lampes terminées
"Go" gauge for caps on finished lamps
BA15d-3(110°), BA15s-3(110°),
BA15d-3(110°), BA15s-3(110°),
BAU15d-3(110°), BAU15s-3(110°),
BAU15d-3(110°), BAU15s-3(110°),
BAW15d, BAW15s
BAW15d, BAW15s
BAW15d-3(110°), BAW15s-3(110°),
BAW15d-3(110°), BAW15s-3(110°),
BAY15d, BAY15s,
BAY15d, BAY15s,
BAY15d-3(110°), BAY15s-3(110°),
BAY15d-3(110°), BAY15s-3(110°),
BAZ15d, BAZ15s,
BAZ15d, BAZ15s,
BAZ15d-3(110°), BAZ15s-3(110°) . 7006-11B-3
BAZ15d-3(110°), BAZ15s-3(110°) . 7006-11B-3
Calibre «Entre» pour culot sur lampes terminées
"Go" gauge for cap on finished lamps
BAZ15d & BAZ15s . 7006-11C-2
BAZ15d & BAZ15s, . 7006-11C-2
Calibre pour la dimension B des culots
Gauge for dimension B of caps
BA15d, BA15s,
BA15d, BA15s,
BA15d-3(100°), BA15s-3(100°),
BA15d-3(100°), BA15s-3(100°),
BAU15d, BAU15s,
BAU15d, BAU15s,
BAU15d-3(100°), BAU15s-3(100°)
BAU15d-3(100°), BAU15s-3(100°)
BAW15d, BAW15s,
BAW15d, BAW15s,
BAW15d-3(100°), BAW15s-3(100°)
BAW15d-3(100°), BAW15s-3(100°)
BAY15d, BAY15s,
BAY15d, BAY15s,
BAY15d-3(100°), BAY15s-3(100°)
BAY15d-3(100°), BAY15s-3(100°)
BAZ15d & BAZ15s,
BAZ15d & BAZ15s,
BAZ15d-3(100°), BAZ15s-3(100°) . 7006-11D-3
BAZ15d-3(100°), BAZ15s-3(100°) . 7006-11D-3
Calibre «Entre» pour culots sur lampes terminées
"Go" gauge for caps on finished lamps
BA15s-3 (100°/130°) . 7006-11E-1
BA15s-3 (100°/130°) . 7006-11E-1

Feuilles Sheet
Calibre «Entre» pour culots BAW15d & BAW15s . 7006-11F-2 "Go" gauge for caps BAW15d & BAW15s . 7006-11F-2
Calibre «Entre» pour culots sur lampes terminées "Go" gauge for caps on finished lamps
BA9s, BA15d, BA15s, BAU15d & BAU15s. 7006-11G-1 BA9s, BA15d, BA15s, BAU15d & BAU15s . 7006-11G-1
Calibres tampon pour douilles Plug gauges for lampholders
BA21d-3(120°), BA21s-3(120°), B15d & B22d . 7006-12-8 BA21d-3(120°), BA21s-3(120°), B15d & B22d . 7006-12-8
Calibres «Entre» supplémentaires pour les Supplementary "Go" gauges for
douilles B22d & BY22d . 7006-12A-2 lampholders B22d & BY22d . 7006-12A-2
Calibre «N'Entre Pas»/Maintien pour "Not Go"/Retention gauge for lampholders
douilles B22d . 7006-12B-2 B22d . 7006-12B-2
Calibre «Entre» supplémentaire pour douilles B15d 7006-12C-2 Supplementary "Go" gauge for lampholders B15d . 7006-12C-2
Calibre «N'Entre Pas»/Maintien pour "Not Go"/Retention gauge for lampholders
douilles B15d . 7006-12D-2 B15d . 7006-12D-2
Calibres pour douilles BA9s, Gauges for lampholders BA9s,
BA15d, BA15s, BA15d, BA15s,
BA15d-3(100°), BA15s-3(100°), BA15d-3(100°), BA15s-3(100°),
BAU15d, BAU15s, BAU15d, BAU15s,
BAU15d-3(100°), BAU15s-3(100°) BAU15d-3(100°), BAU15s-3(100°)
BAW15d, BAW15s, BAW15d, BAW15s,
BAW15d-3(100°), BAW15s-3(100°) BAW15d-3(100°), BAW15s-3(100°)
BAY15d, BAY15s, BAY15d, BAY15s,
BAY15d-3(100°), BAY15s-3(100°) BAY15d-3(100°), BAY15s-3(100°)
BAZ15d & BAZ15s, BAZ15d & BAZ15s,
BAZ15d-3(100°), BAZ15s-3(100°) . 7006-12E-4 BAZ15d-3(100°), BAZ15s-3(100°) . 7006-12E-4
Calibres pour la vérification de la réalité du contact Gauges for testing contact-making in lampholders
dans les douilles BA9s, BA9s,
BA15d, BA15s, BA15d, BA15s,
BA15d-3(100°), BA15s-3(100°), BA15d-3(100°), BA15s-3(100°),
BAU15d, BAU15s, BAU15d, BAU15s,
BAU15d-3(100°), BAU15s-3(100°) BAU15d-3(100°), BAU15s-3(100°)
BAW15d, BAW15s, BAW15d, BAW15s,
BAW15d-3(100°), BAW15s-3(100°) BAW15d-3(100°), BAW15s-3(100°)
BAY15d, BAY15s, BAY15d, BAY15s,
BAY15d-3(100°), BAY15s-3(100°) BAY15d-3(100°), BAY15s-3(100°)
BAZ15d & BAZ15s, BAZ15d & BAZ15s,
BAZ15d-3(100°), BAZ15s-3(100°) . 7006-12F-4 BAZ15d-3(100°), BAZ15s-3(100°) . 7006-12F-4
Calibres pour les encoches des douilles Gauges for slots in lampholders
B15d, B22d, B22d-3 & BY22d . 7006-13-5 B15d, B22d, B22d-3 & BY22d . 7006-13-5
Calibres pour la vérification de la tenue des culots Gauges for testing retention of caps
BA15d, BA15s, BA15d, BA15s,
BA15d-3(100°), BA15s-3(100°), BA15d-3(100°), BA15s-3(100°),
BAU15d, BAU15s, BAU15d, BAU15s,
BAU15d-3(100°), BAU15s-3(100°) BAU15d-3(100°), BAU15s-3(100°)
BAW15d, BAW15s, BAW15d, BAW15s,
BAW15d-3(100°), BAW15s-3(100°) BAW15d-3(100°), BAW15s-3(100°)
BAY15d, BAY15s, BAY15d, BAY15s,
BAY15d-3(100°), BAY15s-3(100°) BAY15d-3(100°), BAY15s-3(100°)
BAZ15d & BAZ15s, BAZ15d & BAZ15s,
BAZ15d-3(100°), BAZ15s-3(100°) . 7006-14-3 BAZ15d-3(100°), BAZ15s-3(100°) . 7006-14-3
Calibres pour la vérification de l'insertion des culots Gauges for testing insertion of caps in lampholders
dans les douilles BA15d, BA15s, BA15d, BA15s,
BA15d-3(100°), BA15s-3(100°), BA15d-3(100°), BA15s-3(100°),
BAU15d, BAU15s, BAU15d, BAU15s,
BAU15d-3(100°), BAU15s-3(100°) BAU15d-3(100°), BAU15s-3(100°)
BAW15d, BAW15s, BAW15d, BAW15s,
BAW15d-3(100°), BAW15s-3(100°) BAW15d-3(100°), BAW15s-3(100°)
BAY15d, BAY15s, BAY15d, BAY15s,
BAY15d-3(100°), BAY15s-3(100°) BAY15d-3(100°), BAY15s-3(100°)
BAZ15d & BAZ15s, BAZ15d & BAZ15s,
BAZ15d-3(100°), BAZ15s-3(100°) . 7006-14A-4 BAZ15d-3(100°), BAZ15s-3(100°) . 7006-14A-4
Calibre pour la dimension B des culots BA15d, Gauge for dimension B of caps BA15d,
BA15s, BAY15d et BAY15s sur lampes terminées . 7006-14B-2 BA15s, BAY15d and BAY15s on finished lamps . 7006-14B-2
Calibre «Entre» pour dimension «P max» des "Go" gauge for dimension "P max" of
culots sur lampes terminées BAY15 . 7006-14C-2 caps on finished lamps BAY15 . 7006-14C-2
Calibre pour la vérification de la position du Gauge for checking contact position
contact et de la force de contact dans les douilles and contact force in bayonet lampholders
à baïonnette B22d-3 (90°/135°) . 7006-15-7 B22d-3 (90°/135°) . 7006-15-7
Calibres pour la vérification de la position du Gauges for checking contact position
contact et de la force de contact dans les douilles and contact force in bayonet lampholders
à baïonnette B22d & BY22d . 7006-15A-2 B22d & BY22d . 7006-15A-2

Fe
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.