IEC 61000-6-6:2003
(Main)Electromagnetic compatibility (EMC) - Part 6-6: Generic standards - HEMP immunity for indoor equipment
Electromagnetic compatibility (EMC) - Part 6-6: Generic standards - HEMP immunity for indoor equipment
This part of IEC 61000 sets high-altitude electromagnetic pulse (HEMP) immunity requirements for electrical and electronic equipment intended for use indoors. The indoor HEMP environment depends on the electromagnetic shielding quality of a facility and the level of protection against the conducted environment. This standard is intended for all facility types including residential, commercial, light industrial, hospitals, heavy industrial, power substations and power generation facilities. This standard includes indoor equipment intended to be connected to a low-voltage (1 kV or less) power network, to the telecom network and/or to external antennas. Immunity test values are based on the 90 % severity levels in IEC 61000-4-25. All telecom lines are assumed to have gas-tube protectors at the point where they enter the building and insulation flashover on low-voltage lines are assumed at three times that of lightning. For signal ports connected to internal cables, severity test levels are based on cables that have a total length of 10 m and a procedure is provided for longer cables. This part of IEC 61000 does not specify safety requirements for equipment, such as protection against shock, insulation coordination, and related dielectric tests. Nevertheless, the immunity tests described in this part of IEC 61000 involve hazardous voltages. High-voltage precautions are necessary to protect the health and safety of test personnel.
Compatibilité électromagnétique (CEM) - Partie 6-6: Normes génériques - Immunité contre l'IEMN-HA pour les appareils situés à l'intérieur des bâtiments
La présente partie de la CEI 61000 concerne les prescriptions d'immunité vis-à-vis de l'IEMN-HA (immunité à l'impulsion électromagnétique nucléaire à haute altitude), pour les appareils électriques et électroniques destinés à fonctionner à l'intérieur des bâtiments. L'environnement IEMN-HA intérieur dépend de la qualité du blindage électromagnétique d'un bâtiment et du niveau de protection contre l'environnement conduit. Cette norme est destinée à tous les types de bâtiments y compris ceux qui sont destinés aux secteurs résidentiel, commercial, pour l'industrie légère, hospitalier, pour l'industrie lourde, les sous-stations et les unités de production de l'énergie électrique. Cette norme couvre les appareils d'intérieur destinés à être connectés à un réseau basse tension (1 kV ou moins), à un réseau de télécommunications et/ou à des antennes extérieures. Les valeurs des essais d'immunité sont basées sur les niveaux de sévérité 90 % spécifiés dans la CEI 61000-4-25. Il est admis que toutes les lignes de télécommunications sont équipées de tube à gaz pour la protection à leur accès dans le bâtiment et que les amorçages au niveau de l'solation sur les lignes basse tension sont le triple de ceux utilisés pour la foudre. Cette partie de la CEI 61000 ne spécifie pas des prescriptions de sécurité pour l'appareil, par exemple relativement à la protection contre les chocs, la coordination de l'isolement, et aux essais diélectriques relatifs. Toutefois, les essais d'immunité décrits dans cette partie de la CEI 61000 incluent les tensions dangereuses. Des mesures spécifiques contre la haute tension sont nécessaires pour protéger la santé et la sécurité du personnel qui effectue des essais.
General Information
Standards Content (Sample)
NORME CEI
INTERNATIONALE IEC
61000-6-6
INTERNATIONAL
Première édition
STANDARD
First edition
2003-04
Compatibilité électromagnétique (CEM) –
Partie 6-6:
Normes génériques –
Immunité contre l'IEMN-HA pour les appareils
situés à l'intérieur des bâtiments
Electromagnetic compatibility (EMC) –
Part 6-6:
Generic standards –
HEMP immunity for indoor equipment
Numéro de référence
Reference number
CEI/IEC 61000-6-6:2003
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(http://www.iec.ch/searchpub/cur_fut.htm) vous permet (http://www.iec.ch/searchpub/cur_fut.htm) enables
de faire des recherches en utilisant de nombreux you to search by a variety of criteria including text
critères, comprenant des recherches textuelles, par searches, technical committees and date of
comité d’études ou date de publication. Des publication. On-line information is also available
informations en ligne sont également disponibles sur on recently issued publications, withdrawn and
les nouvelles publications, les publications rempla- replaced publications, as well as corrigenda.
cées ou retirées, ainsi que sur les corrigenda.
• IEC Just Published • IEC Just Published
Ce résumé des dernières publications parues This summary of recently issued publications
(http://www.iec.ch/online_news/justpub/jp_entry.htm) (http://www.iec.ch/online_news/justpub/jp_entry.htm)
est aussi disponible par courrier électronique. is also available by email. Please contact the
Veuillez prendre contact avec le Service client Customer Service Centre (see below) for further
(voir ci-dessous) pour plus d’informations. information.
• Service clients • Customer Service Centre
Si vous avez des questions au sujet de cette If you have any questions regarding this
publication ou avez besoin de renseignements publication or need further assistance, please
supplémentaires, prenez contact avec le Service contact the Customer Service Centre:
clients:
Email: custserv@iec.ch Email: custserv@iec.ch
Tél: +41 22 919 02 11 Tel: +41 22 919 02 11
Fax: +41 22 919 03 00 Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE IEC
61000-6-6
INTERNATIONAL
Première édition
STANDARD
First edition
2003-04
Compatibilité électromagnétique (CEM) –
Partie 6-6:
Normes génériques –
Immunité contre l'IEMN-HA pour les appareils
situés à l'intérieur des bâtiments
Electromagnetic compatibility (EMC) –
Part 6-6:
Generic standards –
HEMP immunity for indoor equipment
IEC 2003 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
R
Commission Electrotechnique Internationale PRICE CODE
International Electrotechnical Commission
Международная Электротехническая Комиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 61000-6-6 CEI:2003
SOMMAIRE
AVANT-PROPOS . 4
INTRODUCTION .6
1 Domaine d’application . 8
2 Références normatives. 8
3 Considérations générales . 10
4 Termes et définitions. 12
5 Critères d'aptitude à la fonction . 14
5.1 Critère d'aptitude A: performance normale. 16
5.2 Critère d'aptitude B: dégradation temporaire, auto-récupérable. 16
5.3 Critère d'aptitude C: dégradation récupérable. 16
6 Conditions pendant l’essai. 16
7 Documentation du produit. 18
8 Applicabilité . 18
9 Exigences pour les essais d’immunité . 18
Annexe A (informative) Environnements rayonnés et conduits. 32
Bibliographie . 38
Figure 1 – Exemples d'accès . 12
Tableau 1 – Essais d’immunité – Accès par l’enveloppe. 20
Tableau 2 – Essais d’immunité – Accès signaux . 20
Tableau 3 – Essais d’immunité – Accès signaux (antennes extérieures). 22
Tableau 4 – Essais d’immunité – Accès signaux (télécommunications). 22
Tableau 5 – Essais d’immunité – Accès d’entrée et de sortie de puissance en courant
continu . 24
Tableau 6 – Essais d’immunité – Accès d’entrée et de sortie de puissance en courant
alternatif. 26
Tableau 7 – Essais d’immunité – Accès par la borne de terre fonctionnelle . 28
Tableau 8 – Essais d’immunité à l’IEMN-HA pour l’appareil qualifié pour les centrales
électriques et les postes ou les environnements industriels . 30
Tableau A.1 – Environnements rayonnés et conduits pour l’IEMN-HA. 32
Tableau A.2 – Environnements conduits modifiés par le claquage de l’isolation et
exigences minimales d’immunité pour des environnements commerciaux et de
l’industrie légère . 36
61000-6-6 IEC:2003 – 3 –
CONTENTS
FOREWORD . 5
INTRODUCTION .7
1 Scope . 9
2 Normative references. 9
3 General.11
4 Terms and definitions.13
5 Performance criteria.15
5.1 Performance criterion A: normal performance.17
5.2 Performance criterion B: temporary self-recoverable degradation .17
5.3 Performance criterion C: recoverable degradation .17
6 Conditions during testing.17
7 Product documentation .19
8 Applicability.19
9 Immunity test requirements .19
Annex A (informative) Radiated and conducted environments .33
Bibliography .39
Figure 1 – Examples of ports .13
Table 1 – Immunity tests – Enclosure port .21
Table 2 – Immunity tests – Signal ports .21
Table 3 – Immunity tests – Signal ports (exterior antennas) .23
Table 4 – Immunity tests – Signal ports (telecommunication) .23
Table 5 – Immunity tests – Input and output d.c. power ports .25
Table 6 – Immunity tests – Input and output a.c. power ports .27
Table 7 – Immunity tests – Functional earth port .29
Table 8 – HEMP Immunity tests for equipment qualified for power station or industrial
environments.31
Table A.1 – Radiated and conducted environments for early time HEMP .33
Table A.2 – Conducted environments modified by insulation breakdown and minimum
immunity requirements for commercial and light-industry environments.37
– 4 – 61000-6-6 CEI:2003
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
___________
COMPATIBILITÉ ÉLECTROMAGNÉTIQUE (CEM) –
Partie 6-6: Normes génériques –
Immunité contre l’IEMN-HA pour les appareils
situés à l’intérieur des bâtiments
AVANT-PROPOS
1) La CEI (Commission Électrotechnique Internationale) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes Internationales.
Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national intéressé par le
sujet traité peut participer. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement avec l'Organisation
Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, spécifications techniques, rapports techniques ou guides et agréés comme tels par les Comités
nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Norm
...
Questions, Comments and Discussion