IEC 61076-2:2011
(Main)Connectors for electronic equipment - Product requirements - Part 2: Sectional specification for circular connectors
Connectors for electronic equipment - Product requirements - Part 2: Sectional specification for circular connectors
IEC 61076-2:2011 establishes uniform specifications and technical information for circular connectors. It should be used in conjunction with the generic specification IEC 61076-1:2006 for product requirements and with IEC 62197-1 for quality requirements as the basis for preparation of consistent detail product specifications for circular connectors. In the event of conflict between this sectional specification and the detail product specification, it is intended that the requirements of the detail product specification prevail. This second edition cancels and replaces the first edition of IEC 61076-2 (1998). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition. This International Standard no longer includes the quality assessment procedures. As described in IEC 61076-1 and IEC 62197-1, a new document structure has been established. IEC 61076-2 has been revised to reflect this updated structure. Subclause 3.2, Systems of levels has been introduced. The subclause on IEC type designation has been removed. Clauses 4 Dimensional information and 5 Characteristics have been added. Some clauses and test groups have been rearranged. Test group HP has been added.
Connecteurs pour équipements électroniques - Exigences de produit - Partie 2: Spécification intermédiaire pour les connecteurs circulaires
La CEI 61076-2:2011 établit des spécifications et donne des informations techniques uniformes pour les connecteurs circulaires. Il convient de l'utiliser conjointement avec la spécification générique CEI 61076-1 Ed.2 pour les exigences de produit et avec la CEI 62197-1 pour les exigences de qualité pour servir de base à l'établissement de spécifications particulières de produit cohérentes pour les connecteurs circulaires. En cas de divergence entre la présente spécification intermédiaire et la spécification particulière de produit, il est prévu que les exigences de cette dernière prévalent. Cette deuxième édition annule et remplace la première édition publiée en 1998. Cette édition constitue une révision technique. La présente édition inclut les modifications techniques significatives suivantes par rapport à l'édition précédente. La présente Norme Internationale ne contient plus les procédures d'assurance de la qualité. Une nouvelle structure de document a été établie comme cela est décrit dans les CEI 61076-1 et CEI 62197-1. La CEI 61076-2 a été révisée dans le cadre de cette structure mise à jour. Un paragraphe 3.2, Systèmes des niveaux a été introduit. Le paragraphe concernant la désignation de type CEI a été supprimé. Un Article 4 Informations relatives aux dimensions et un Article 5 Caractéristiques ont été ajoutés. Certains articles et groupes d'essai ont subi des modifications. Le groupe d'essais HP a été ajouté.
General Information
Relations
Standards Content (Sample)
IEC 61076-2 ®
Edition 2.0 2011-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electronic equipment – Product requirements –
Part 2: Sectional specification for circular connectors
Connecteurs pour équipements électroniques – Exigences de produit –
Partie 2: Spécification intermédiaire pour les connecteurs circulaires
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 61076-2 ®
Edition 2.0 2011-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electronic equipment – Product requirements –
Part 2: Sectional specification for circular connectors
Connecteurs pour équipements électroniques – Exigences de produit –
Partie 2: Spécification intermédiaire pour les connecteurs circulaires
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX R
ICS 31.220.10 ISBN 978-2-88912-565-4
– 2 – 61076-2 IEC:2011
CONTENTS
FOREWORD . 3
1 Scope . 5
2 Normative references . 5
3 Technical information . 5
3.1 Terms and definitions . 5
3.2 System of levels . 6
3.2.1 Performance levels . 6
3.2.2 Compatibility levels, according to IEC 61076-1 . 6
3.3 Classification into climatic categories . 6
3.4 Creepage and clearance distances . 6
3.5 Current-carrying capacity . 6
3.6 Marking . 6
4 Dimensional information . 6
5 Characteristics . 7
6 Tests and test schedules . 7
6.1 General aspects . 7
6.2 Test schedules . 7
6.2.1 General . 7
6.2.2 Basic (minimum) test schedule . 8
6.2.3 Full test schedule . 8
6.3 Test procedures and measuring methods . 18
6.4 Pre-conditioning . 18
6.5 Wiring and mounting of specimens . 18
6.5.1 Wiring . 18
6.5.2 Mounting . 18
7 Blank detail product specification – General . 18
Table 1 – Basic tests (minimum) . 8
Table 2 – Test group P . 9
Table 3 – Test group AP . 10
Table 4 – Test group BP . 12
Table 5 – Test group CP . 13
Table 6 – Test group DP . 14
Table 7 – Test group EP . 15
Table 8 – Test group FP . 15
Table 9 – Test group GP . 16
Table 10 – Test group HP . 16
Table 11 – Test group KP . 17
Table 12 – Test group LP . 17
61076-2 IEC:2011 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
CONNECTORS FOR ELECTRONIC EQUIPMENT –
PRODUCT REQUIREMENTS –
Part 2: Sectional specification for circular connectors
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61076-2 has been prepared by subcommittee 48B: Connectors, of
IEC technical committee 48: Electromechanical components and mechanical structures for
electronic equipment.
This second edition cancels and replaces the first edition of IEC 61076-2 (1998). This edition
constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition.
– This International Standard no longer includes the quality assessment procedures. As
described in IEC 61076-1 and IEC 62197-1, a new document structure has been
established. IEC 61076-2 has been revised to reflect this updated structure.
– Subclause 3.2, Systems of levels has been introduced.
– The subclause on IEC type designation has been removed.
– 4 – 61076-2 IEC:2011
– Clauses 4 Dimensional information and 5 Characteristics have been added.
– Some clauses and test groups have been rearranged. Test group HP has been added.
The text of this standard is based on the following documents:
FDIS Report on voting
48B/2240/FDIS 48B/2247/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 61076 series, published under the general title Connectors for
electronic equipment – Product requirements, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
61076-2 IEC:2011 – 5 –
CONNECTORS FOR ELECTRONIC EQUIPMENT –
PRODUCT REQUIREMENTS –
Part 2: Sectional specification for circular connectors
1 Scope
This part of IEC 61076 establishes uniform specifications and technical information for
circular connectors. It should be used in conjunction with the generic specification
IEC 61076-1:2006 for product requirements and with IEC 62197-1 for quality requirements as
the basis for preparation of consistent detail product specifications for circular connectors.
NOTE 1 It is intended that a detail quality specification, IEC 62197-2-1XX, be prepared, based on the blank detail
specification for circular connectors IEC 62197-2-001, to be used in addition to the corresponding detail product
specification IEC 61076-2-1XX.
NOTE2 The quality assessment requirements for connectors according to the IEC 61076series are detailed in
IEC 62197-1.
In the event of conflict between this sectional specification and the detail product
specification, it is intended that the requirements of the detail product specification prevail.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60068-1, Environmental testing – Part 1: General and guidance
IEC 60352 (all parts), Solderless connections
IEC 60512 (all parts), Connectors for electronic equipment – Basic testing procedures and
measuring methods
IEC 60512-1-100, Connectors for electronic equipment – Tests and measurements –
Part 1-100: General – Applicable publications
IEC 61076-1:2006, Connectors for electronic equipment – Product requirements – Part 1:
Generic specification
IEC 61076-2-001, Connectors for electronic equipment – Part 2-001: Circular connectors –
Blank detail specification
IEC 62197-1, Connectors for electronic equipment – Quality assessment requirements –
Part 1: Generic specification
3 Technical information
3.1 Terms and definitions
Terminology used in and applicable to this International Standard is stated in 2.1 of
IEC 61076-1. IEC 60512-1 also contains applicable terms.
– 6 – 61076-2 IEC:2011
3.2 System of levels
3.2.1 Performance levels
If appropriate, the detail product specification shall contain information about the different
performance levels.
The term ‘performance level’ reflects the grouping of the environmental and mechanical
stresses at which a component is tested, and also such features as long-term stability of
electrical characteristics. If different levels are defined in the detail product specification, they
have to be numbered, where the lowest number (1) usually indicates the highest performance.
3.2.2 Compatibility levels, according to IEC 61076-1
As a function of the standardization degree, four levels characterize the compatibility of
connectors from different sources. These levels are defined in 2.2.3.2 to 2.2.3.5 of
IEC 61076-1:2006 and should, when appropriate, be indicated in the detail product
specification of circular connectors.
3.3 Classification into climatic categories
Unless impractical, the lower and upper temperatures and the duration of the damp heat,
steady state test should be described in a table similar to the example given in 2.3 of
IEC 61076-1:2006.
3.4 Creepage and clearance distances
Permissible working or rated voltages depend on the application and on the applicable or
specified safety requirements.
Therefore, clearance and creepage distances as well as proof voltages under specified air
pressure shall be specified in the detail product specification.
3.5 Current-carrying capacity
For each connector, the current-carrying capacity shall be specified in the detail product
specification, preferably by the de-rating curve determined in accordance with test 5b of
IEC 60512-5-2.
3.6 Marking
Each connector and its associated package shall be marked in accordance with the
requirements specified in 2.7 of IEC 61076-1:2006.
4 Dimensional information
Dimensions provided in the detail product specification for circular connectors shall provide
– mating information;
– mounting information;
– overall dimension;
– locking and sealing information, if appropriate;
– information on termination and cable fixing.
For more details see 3.1 to 3.5 of IEC 61067-1 Ed. 2.0.
61076-2 IEC:2011 – 7 –
5 Characteristics
To provide information on specified essential electrical and mechanical characteristics,
preferred methods on tests and measurements are listed; additional characteristics may be
added to the detail product specification, when appropriate.
6 Tests and test schedules
6.1 General aspects
See Clause 5 of IEC 61076-1:2006.
The detail product specification shall state the test sequence(s) (in accordance with this
standard), and the number of specimens for each test sequence (not less than four mated
pairs).
Individual variants may be submitted to type tests for approval of those particular variants.
It is permissible to limit the number of variants tested to a selection representative of the
whole range for which approval is required (which may be less than the range covered by the
detail product specification), but each feature and characteristic shall be proved.
The connectors shall have been processed in a careful and workmanlike manner, in
accordance with good current practice.
6.2 Test schedules
6.2.1 General
To provide for different applications of connectors, the extent of the test schedule may be
different in the various detail product specifications.
The basic (minimum) test schedule is given in 6.2.2.
The detail product specification shall state the tests to be carried out and shall specify the
requirements to be fulfilled.
In no case shall the tests required by the detail product specification be less than those listed
in 6.2.2.
A full test schedule is laid down in 6.2.3. This should be used to evaluate connectors used in
severe environments (e.g. aircraft or marine environments).
For most connector types, an intermediate test schedule may be appropriate. This
intermediate test schedule shall then be formed by omitting entire groups and/or conditionings
from the full test schedules that are not necessary.
Test phase numbers shall not be modified but used as given in 6.2.3.
The same is applicable when the sequence of the test phases in a test group is not entirely
appropriate to a particular type or style. In that case, the sequence of the tests, but not the
measurement to be performed subsequent to tests, may be altered for that particular detail
product specification.
The test phase number shall be retained for each test thereby affording clarity should such
alteration in sequence be conducted.
– 8 – 61076-2 IEC:2011
Where a detail product specification includes additional characteristics which require testing
and/or specific test sequences, the appropriate existing or new test (in the form of a
normative annex to the detail product specification) shall be in the appropriate place in the
test table. These may be specified in an additional test group or groups; see test group HP.
NOTE It is necessary for the detail product specification to select the appropriate basic, intermediate or full test
schedule.
6.2.2 Basic (minimum) test schedule
Where the basic (minimum) test schedule is appropriate, the detail product specification shall
call for the following tests listed in Table 1 and shall specify the characteristics to be
examined and the requirements to be fulfilled.
Table 1 – Basic tests (minimum)
Test Measurement to be performed
Test Title IEC 60512 Severity or Title IEC 60512 Require-
phase condition of ments
a
Test No. Test No.
test in DS in DS
1 General 1 Visual examination 1a X
examination
Examination of dimension 1b X
and mass
2.1 Engaging and separating 13a X
forces
or
2.2 Insertion and withdrawal 13b X
forces
3 Contact resistance – 2a X
Millivolt level method
or or
Contact resistance – 2b
Specified test current
method
4 Insulation resistance 3a X
5 Voltage proof 4a X
6.1 Soldering One or X Contact resistance – 2a X
several of Millivolt level method
or
the tests
or or
of the 12a
6.2 Other applicable
to 12e
terminations Contact resistance – 2b
series
Specified test current
method
b
X To be specified in the detail product specification.
a See IEC 60512-1-100 for a list and the numbers of the test methods.
b Where applicable, other appropriate connection tests shall be additional to, or replace, the specified tests, for
example, tests of IEC 60512 or tests of the applicable parts of IEC 60352.
6.2.3 Full test schedule
6.2.3.1 General
Where the full test schedule is appropriate, the detail product specification shall call for the
following tests (Tables 2 to 12) and shall specify the characteristics to be examined and the
requirements to be fulfilled.
61076-2 IEC:2011 – 9 –
The schedule detailed below is recommended for preparing detail product specifications,
however, specific design and application features shall carefully be taken into account when
preparing the detail product specification. The schedule detailed below shall be used as a
guide. The test phase numbering should be used as specified below.
To comply with the different applications of connectors, the test schedule of the detail product
specifications may be extended to provide performance for different fields of application.
For solderless terminations, test sequences of the applicable part of IEC 60352 shall be
integrated into the appropriate full test schedule.
6.2.3.2 Test group P – Preliminary tests
All specimens shall be subjected to the following tests. All the test group specimens shall be
subjected to the preliminary group P tests in the following sequence.
Table 2 – Test group P
Test Measurement to be performed
Test Title IEC 60512 Severity or Title IEC 60512 Require-
phase condition ments
Test No. Test No.
of test in DS
in DS
P1 General examination 1 Visual examination 1a X
Examination of dimension 1b X
and mass
P2 Polarizing method 13e X
P3 Restricted entry 16b
P4 Contact resistance – 2a X
Millivolt level method
or or
Contact resistance – 2b
Specified test current method
P5 Insulation resistance 3a X
(Note 1)
P6 Voltage proof 4a X
(Note 2)
P7 Sealing 14a 5 min in
(gross air leakage) each
direction
P7.1 Sealing 14b
(fine air leakage)
P8 Electrical 1c X
engagement length
P9 Residual magnetism 24a
P10 Contact protection 1d
effectiveness (scoop
proof)
X To be specified in the detail product specification.
NOTE 1 If specified in the detail product specification the insulation resistance shall also be measured between one
termination and housing having minimum spacing.
NOTE 2 When applicable the detail product specification shall specify whether the connectors are to be mated or
unmated for this test. The specimen shall be subjected to the test voltage between one termination and the housing
having a minimum spacing.
– 10 – 61076-2 IEC:2011
The specimens shall then be divided into the appropriate number of groups. All connectors in
each group shall undergo the following tests as described in the detail product specification
and in the sequence given, unless the detail product specification requires alteration of the
sequence of tests or adds new tests to verify additional connector characteristics (see 6.2).
The specimens shall be divided into these groups. All connectors in each group shall undergo
the tests specified for the relevant group.
6.2.3.3 Test group AP – Dynamic/climatic tests
Table 3 – Test group AP
Test Measurement to be performed
Test Title IEC 60512 Severity or Title IEC 60512 Require-
phase condition ments
Test No. Test No.
of test in DS
in DS
AP1 Probe damage 16a X
AP2 Gauge retention force 16e X X
(resilient contacts)
AP3 Engaging and separating 13a X
(note 2) forces
AP4 Voltage proof 4a X
(note 2)
AP5 Mechanical strength 7b X
impact
AP6 Contact retention in 15a X
insert
Visual examination 1a X
AP7 Insert retention in 15c X
housing (torsional)
Visual examination 1a X
AP8 Bump 6b X Contact disturbance 2e X
AP9 Vibration 6d X Contact resistance variation 2c X
or (during test)
random vibration 6e
AP10 Shock 6c X Contact disturbance 2e X
AP11 Acceleration, steady- 6a X
state
AP12 Rapid change of 11d X
temperature
Voltage proof 4a X
Insulation resistance 3a X
AP13 Static load, transverse 8a X
AP14 Static load, axial 8b X
61076-2 IEC:2011 – 11 –
Table 3 – Test group AP (concluded)
Test Measurement to be performed
Test Title IEC 60512 Severity or Title IEC 60512 Require-
phase condition ments
Test No. Test No.
of test in DS
in DS
AP15 Sealing (gross air leakage) 14a 5 min in
each
Sealing (fine air leakage) 14b
direction
AP16 Visual examination 1a X
AP17 Climatic sequence 11a X
AP18-1 Dry heat 11i X
(Note 2)
AP18-2 Low air pressure 11k X
AP18-3 Damp heat, cyclic 11m X
(first cycle)
AP18-4 Cold 11j X
AP18-5 Low air pressure 11k X
AP18-6 Damp heat, cyclic 11m X
(remaining cycles)
AP19 Impacting water 14g * X
Insulation resistance 3a X
(Note 1)
Contact resistance – 2a X
Millivolt level method
or
Contact resistance –
2b
Specified test current
method
Voltage proof 4a X
(Note 2)
AP20 Engaging and separating 13a X
(note 2) forces
Visual examination 1a X
AP21 Contact retention 15h X
system, resistance
to tool application
a
AP22 Interfacial sealing 14f X
Voltage proof 4a X
(Note 2)
AP23 Insert retention in 15b X
housing (axial)
X To be specified in the detail product specification.
NOTES See Table 2.
a
As an alternative, a test for the second numeral of the IP degree of protection according to IEC 60529 can be
performed, when assigned by the DS or the manufacturer.
– 12 – 61076-2 IEC:2011
6.2.3.4 Test group BP – Mechanical/climatic tests
Table 4 – Test group BP
Test Measurement to be performed
Test Title IEC 60512 Severity or Title IEC 60512 Require-
phase condition ments
Test No. Test No.
of test in DS
in DS
BP1 Engaging and separating 13a X
(Note 2) forces
BP2 Mechanical operation 9a X
(half of the specified
number of operations)
BP3 Climatic test X
BP3.1 Corrosion, salt mist 11f X
or
BP3.2 Corrosion, industrial 11g X
atmosphere or
BP3.3 Climatic sequence or 11a X
BP3.4 Damp heat, steady- 11c X
state
or
Damp heat, cyclic 11m X
Contact resistance – 2a X
Millivolt level method
or
Contact resistance – 2b
Specified test current
method
BP4 Mechanical operation 9a X
(the remaining
number of operations)
Insulation resistance 3a X
(Note 1)
Housing (shell) 2f X
electrical continuity
Voltage proof 4a X
(Note 2)
BP5 Engaging and separating 13a X
(Note 2) forces (cold)
BP6 Gauge retention force 16e X
(resilient contacts)
BP7 Contact insertion, 15d X
release and
a
extraction force
BP8 Contact retention in 15e X
insert, cable nutation
b
BP9 Static load, axial 8b X Visual examination 1a
X To be specified in the detail product specification.
NOTES See Table 2.
a
Not on contacts to be tested in phase P.
b
Applicable to removable contacts only.
61076-2 IEC:2011 – 13 –
6.2.3.5 Test group CP – Moisture
Table 5 – Test group CP
Test Measurement to be performed
Test Title IEC 60512 Severity or Title IEC 60512 Require-
phase condition ments
Test No. Test No.
of test in DS
in DS
CP1 Immersion at low air 14e X Insulation resistance 3a X
pressure (Note 1)
CP2 Damp heat, steady- 11c X Insulation resistance 3a X
state (Note 1)
Housing (shell) 2f X
electrical continuity
Contact resistance – 2a X
Millivolt level method
or
Contact resistance – 2b X
Specified test current
method
Voltage proof 4a X
(Note 2)
Engaging and separating 13a X
forces (Note 2)
CP3 Sealing (gross air leakage) 14a 5 min in
each
direction
Sealing (fine air leakage) 14b X
CP4 Visual examination 1a X
CP5 Contact retention in insert 15a X
X To be specified in the detail product specification.
NOTES See Table 2.
– 14 – 61076-2 IEC:2011
6.2.3.6 Test group DP – Endurance
Table 6 – Test group DP
Test Measurement to be performed
Test Title IEC 60512 Severity or Title IEC 60512 Require-
phase condition ments
Test No. Test No.
of test in DS
in DS
DP1 Rapid change of 11d X
temperature
DP2 Mechanical operation 9a X
DP3 Electrical load and 9b X Insulation resistance 3a X
temperature (Note 1)
Contact resistance – 2a X
Millivolt level method
or
Contact resistance – 2b
Specified test current
method
Voltage proof 4a X
(Note 2)
DP4 Durability of contact 9d X
retention system and
seals
(maintenance, ageing)
DP5 Sealing (gross air leakage) 14a X
Sealing (fine air leakage) 14b X
DP6 Interfacial sealing 14f X
DP7 Visual examination 1a X
DP8 Sand and dust 11h X
DP9 Functional check of 13a By hand
engaging and separating X
DP10 Free fall (repeated) 7a X
Visual examination 1a X
X To be specified in the detail product specification.
NOTES See Table 2.
61076-2 IEC:2011 – 15 –
6.2.3.7 Test group EP – Mould/Fire
Table 7 – Test group EP
Test Measurement to be performed
Test Title IEC 60512 Severity or Title IEC 60512 Require-
phase condition ments
Test No. Test No.
of test in DS
in DS
EP1 Robustness of 16f X
termination
EP2 Measurement of 16g X
contact deformation
after crimping
EP3 Mould growth 11e X Initial
approval
only
Insulation resistance 3a X
(Note 1)
Visual examination 1a X
EP4 Flammability 20a X
(needle flame)
EP5 Fireproofness 20b X
X To be specified in the detail product specification.
NOTES See Table 2.
6.2.3.8 Test group FP – Fluids
Table 8 – Test group FP
Test Measurement to be performed
Test Title IEC 60512 Severity or Title IEC 60512 Require-
phase condition ments
Test No. Test No.
of test in DS
in DS
FP1 Fluid resistance 19c X
FP2 Engaging and separating 13a X
(Note 2) forces
FP3 Contact resistance – 2a X
Millivolt level method
or
Contact resistance – 2b
Specified test current
method
FP4 Insulation resistance 3a X
(Note 1)
FP5 Contact retention in insert 15a X
FP6 Insert retention in housing 15b X
(axial)
FP7 Visual examination 1a X
X To be specified in the detail product specification.
NOTES See Table 2.
– 16 – 61076-2 IEC:2011
6.2.3.9 Test group GP – Connection method tests
Table 9 – Test group GP
Test Measurement to be performed
Test Title IEC 60512 Severity or Title IEC 6051 Require-
phase condition 2 ments
Test No.
of test in DS
Test No.
in DS
GP1 Connections, Applicable
solderless, part of
X
IEC 60352
GP2 Solderability 12a or X X
12b or 12c
X To be specified in the detail product specification.
6.2.3.10 Test group HP – Accessories
Table 10 – Test group HP
Test Measurement to be performed
Test Title IEC 60512 Severity or Title IEC 60512 Require-
phase condition ments
Test No. Test No.
of test in DS
in DS
HP1 Cable clamp 17a X
robustness
HP2 Cable clamp 17b X
resistance to cable
rotation
HP3 Cable clamp 17c X
resistance to cable
pull (tensile)
HP4 Cable clamp 17d X
resistance to cable
torsion
HP5 Robustness of 15g X
protective cover
attachment
X To be specified in the detail product specification.
61076-2 IEC:2011 – 17 –
6.2.3.11 Test group KP – Climatic sequence
Table 11 – Test group KP
Test Measurement to be performed
Test Title IEC 60512 Severity or Title IEC 60512 Require-
phase condition ments
Test No. Test No.
of test in DS
in DS
KP1 Combined/sequential 11b X
cold, low air pressure
and damp heat
KP2 Ozone resistance X
KP3 Voltage proof 4a X
(note 1)
KP4 X Contact resistance – 2a X
Millivolt level method
or
Contact resistance – 2b
Specified test current
method
X To be specified in the detail product specification.
NOTES See Table 2.
6.2.3.12 Test group LP – Dynamic corrosion
Table 12 – Test group LP
Test Measurement to be performed
Title IEC 60512 Severity or Title IEC 60512 Require-
Test
condition ments
phase
Test No. Test No.
of test in DS
in DS
LP1 Visual examination 1a X
LP2 Grounding contact spring 16i X
holding force
LP3 Housing (shell) 2f X
electrical continuity
LP4 RFI shielding – 23a X
Frequency range
10 kHz to 100 MHz
100 MHz to 1 GHz
LP5 Mechanical operation 9a X
LP6 Rapid change of 11d X
temperature
LP7 Corrosion, salt mist 11f X
Housing (shell) 2f X
electrical continuity
RFI shielding – 23a X
Frequency range
10 kHz to 100 MHz
100 MHz to 1 GHz
X To be specified in the detail product specification.
– 18 – 61076-2 IEC:2011
6.3 Test procedures and measuring methods
The test methods specified and given in the relevant standards are the preferred methods but
not necessarily the only ones which can be used. In case of dispute, however, the specified
method shall be used as the reference method.
Unless otherwise specified, all tests shall be carried out under standard atmospheric
conditions for testing as specified in IEC 60068-1.
Where approval procedures are involved and alternative methods are employed it is the
responsibility of the manufacturer to satisfy the authority granting approval that any
alternative methods which he may use give results equivalent to those obtained by the
methods specified.
6.4 Pre-conditioning
Before the tests are made, the connectors shall be preconditioned under standard
atmospheric conditions for testing as specified in IEC 60068-1 for a period of 24 h unless
otherwise specified by the detail product specification.
6.5 Wiring and mounting of specimens
6.5.1 Wiring
Where wiring of test specimens is required, the detail product specification shall contain
information suitable to comply with the selected methods of test.
6.5.2 Mounting
When mounting is required in a test, unless otherwise specified, the connectors shall be
rigidly mounted on a metal plate or to specified accessories, whichever is applicable, using
the specified connection methods, fixing devices and panel cut-outs as laid down in the detail
product specification.
7 Blank detail product specification – General
A blank detail product specification forms a supplement to the sectional specification and
contains requirements for style and layout and minimum content of the detail product
specification, thus ensuring a uniform presentation.
Its contents shall be derived from the generic or sectional specification and shall list a
selection of technical criteria necessary to describe a connector subfamily.
Detail product specifications not complying with these requirements may not be considered as
being in accordance with IEC specifications nor shall they be so described.
In the preparation of the blank detail product specification for circular connectors,
IEC 61076-2-001, the content of this sectional product specification shall be taken into
account.
_____________
– 20 – 61076-2 CEI:2011
SOMMAIRE
AVANT-PROPOS . 21
1 Domaine d’application . 23
2 Références normatives . 23
3 Données techniques . 24
3.1 Termes et définitions . 24
3.2 Système des niveaux . 24
3.2.1 Niveaux de performance . 24
3.2.2 Niveaux de compatibilité selon la CEI 61076-1 . 24
3.3 Classification en catégories climatiques . 24
3.4 Lignes de fuite et distances d'isolement . 24
3.5 Courant limite admissible . 24
3.6 Marquage . 24
4 Informations relatives aux dimensions . 24
5 Caractéristiques . 25
6 Essais et programmes d’essais . 25
6.1 Généralités. 25
6.2 Programmes d’essais . 25
6.2.1 Généralités . 25
6.2.2 Programme d’essais de base (minimal) . 26
6.2.3 Programme d’essais complet . 27
6.3 Procédures d’essai et méthodes de mesure . 37
6.4 Pré-conditionnement . 37
6.5 Câblage et montage des spécimens . 37
6.5.1 Câblage . 37
6.5.2 Montage . 37
7 Spécification particulière cadre de produit – Généralités . 37
Tableau 1 – Programme d’essais de base (minimal) . 26
Tableau 2 – Groupe d’essais P . 28
Tableau 3 – Groupe d’essais AP . 29
Tableau 4 – Groupe d’essais BP . 31
Tableau 5 – Groupe d’essais CP . 32
Tableau 6 – Groupe d’essais DP . 33
Tableau 7 – Groupe d’essais EP . 34
Tableau 8 – Groupe d’essais FP . 34
Tableau 9 – Groupe d’essais GP . 35
Tableau 10 – Groupe d’essais HP . 35
Tableau 11 – Groupe d’essais KP . 36
Tableau 12 – Groupe d’essais LP . 36
61076-2 CEI:2011
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...