Semiconductor devices - Micro-electromechanical devices - Part 12: Bending fatigue testing method of thin film materials using resonant vibration of MEMS structures

IEC 62047-12:2011 specifies a method for bending fatigue testing using resonant vibration of microscale mechanical structures of MEMS (micro-electromechanical systems) and micromachines. This standard applies to vibrating structures ranging in size from 10 μm to 1 000 μm in the plane direction and from 1 μm to 100 μm in thickness, and test materials measuring under 1 mm in length, under 1 mm in width, and between 0,1 μm and 10 μm in thickness. The main structural materials for MEMS, micromachine, etc. have special features, such as typical dimensions of a few microns, material fabrication by deposition, and test piece fabrication by means of non-mechanical machining, including photolithography. The MEMS structures often have higher fundamental resonant frequency and higher strength than macro structures. To evaluate and assure the lifetime of MEMS structures, a fatigue testing method with ultra high cycles (up to 1012) loadings needs to be established. The object of the test method is to evaluate the mechanical fatigue properties of microscale materials in a short time by applying high load and high cyclic frequency bending stress using resonant vibration.

Dispositifs à semiconducteurs - Dispositifs microélectromécaniques - Partie 12: Méthode d'essai de fatigue en flexion des matériaux en couche mince utilisant les vibrations à la résonance des structures à systèmes microélectromécaniques (MEMS)

La CEI 62047-12:2011 spécifie une méthode d'essai de fatigue en flexion utilisant les vibrations à la résonance des structures mécaniques à très petite échelle des systèmes microélectromécaniques (MEMS), et des micromachines. La présente norme s'applique aux structures vibrantes dont la taille est dans la gamme allant de 10 μm à 1 000 μm dans le plan et de 1 μm à 100 μm d'épaisseur, ainsi qu'à des matériaux d'essai mesurant moins de 1 mm de longueur, moins de 1 mm de largeur et entre 0,1 μm et 10 μm d'épaisseur. Les matériaux de construction principaux pour les systèmes microélectromécaniques, les micromachines, etc., comportent des caractéristiques spéciales telles que des dimensions typiques de l'ordre de quelques microns, la fabrication des matériaux par dépôt et la fabrication d'éprouvettes d'essai par usinage non mécanique, par exemple la photolithographie. Les structures à systèmes micro-électromécaniques présentent souvent une fréquence de résonance fondamentale et une résistance supérieures à celles des macro-structures. Pour évaluer et garantir la durée de vie des structures à systèmes microélectromécaniques, on doit établir une méthode d'essai de fatigue avec des cycles de charge très élevés (jusqu'à 1012). Le but de la méthode d'essai est d'évaluer les propriétés de fatigue mécanique des matériaux à très petite échelle sur une courte durée en appliquant une contrainte de flexion à charge élevée et à haute fréquence cyclique en utilisant des vibrations à la résonance.

General Information

Status
Published
Publication Date
12-Sep-2011
Current Stage
PPUB - Publication issued
Start Date
13-Sep-2011
Completion Date
15-Jul-2011
Ref Project

Overview

IEC 62047-12:2011 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies a bending fatigue testing method for thin film materials using resonant vibration of micro-electromechanical systems (MEMS) structures. This novel method targets the precise evaluation of mechanical fatigue properties of microscale materials by applying high cyclic frequency bending stress under resonant vibration. It addresses the unique characteristics of MEMS and micromachine structural materials, which typically range in size from a few microns to around 1 millimeter and exhibit high resonant frequencies and strength.

The main focus of IEC 62047-12 is to provide a standardized approach for ultra-high cycle fatigue testing (up to 10^12 cycles) on microscale thin film materials, facilitating faster and more reliable assessment of MEMS lifetime and durability. This is essential given the increasingly critical role of MEMS in modern electronics and semiconductor devices.

Key Topics

  • Scope and Application
    Applicable to microscale mechanical structures with plane dimensions from 10 µm to 1000 µm and thicknesses from 1 µm to 100 µm. The tested thin film materials typically range under 1 mm in overall dimensions, with thicknesses between 0.1 µm and 10 µm.

  • Test Methodology
    Utilizes resonant vibration to induce high-frequency bending stresses. The method exploits the resonant properties of MEMS structures to accelerate fatigue testing without compromising the accuracy of mechanical property evaluation.

  • Test Equipment Components

    • Actuators for vibration excitation
    • Sensors for displacement or strain detection
    • Controllers and recorders for feedback and data acquisition
    • Parallel testing setups to optimize throughput
  • Specimen Preparation
    Specimens are manufactured using non-mechanical machining techniques such as photolithography and material deposition processes, reflecting typical MEMS fabrication methods.

  • Test Conditions and Parameters
    Parameters include test amplitude, load ratio, vibration frequency, waveform, test time, and controlled environmental conditions to simulate real-world usage.

  • Measurement and Monitoring
    Initial reference strength is established before testing. Continuous monitoring during testing ensures precise counting of fatigue cycles and accurate detection of failure points.

Applications

  • MEMS Reliability and Lifetime Prediction
    Using IEC 62047-12 facilitates accelerated fatigue life evaluation of MEMS components such as sensors, actuators, and micromachines, vital for consumer electronics, automotive systems, medical devices, and aerospace technologies.

  • Thin Film Material Research and Development
    Enables manufacturers and researchers to assess new thin film materials and deposition techniques with regard to fatigue performance at microscale dimensions.

  • Quality Assurance in Semiconductor Manufacturing
    Helps semiconductor device producers ensure consistent strength and durability of micro-electromechanical structures, reducing failures in final products.

  • Design Optimization
    Supports iterative design improvements by providing reliable fatigue data, leading to enhanced material selection and structural configurations for MEMS devices.

Related Standards

  • IEC 62047-3:2006
    Thin film standard test piece for tensile testing – complements IEC 62047-12 by providing foundational tensile test methods for micro-electromechanical devices.

  • ISO 12107
    Metallic materials – Fatigue testing – Statistical planning and data analysis – offers methodologies for fatigue testing and statistical evaluation applicable to microscale materials as adapted in IEC 62047-12.

  • Other Parts of IEC 62047 Series
    The IEC 62047 series covers various aspects of semiconductor and MEMS device testing, each addressing specific mechanical and electrical evaluation methods.


By adopting IEC 62047-12:2011, organizations can ensure standardized, efficient, and high-precision fatigue testing of MEMS thin films, directly supporting the development of robust semiconductor and micro-electromechanical devices tailored for high-performance applications. This standard is an essential resource for engineers, researchers, and manufacturers involved in the advancement of microscale device technologies.

Standard
IEC 62047-12:2011 - Semiconductor devices - Micro-electromechanical devices - Part 12: Bending fatigue testing method of thin film materials using resonant vibration of MEMS structures
English and French language
59 pages
sale 15% off
Preview
sale 15% off
Preview

Frequently Asked Questions

IEC 62047-12:2011 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Semiconductor devices - Micro-electromechanical devices - Part 12: Bending fatigue testing method of thin film materials using resonant vibration of MEMS structures". This standard covers: IEC 62047-12:2011 specifies a method for bending fatigue testing using resonant vibration of microscale mechanical structures of MEMS (micro-electromechanical systems) and micromachines. This standard applies to vibrating structures ranging in size from 10 μm to 1 000 μm in the plane direction and from 1 μm to 100 μm in thickness, and test materials measuring under 1 mm in length, under 1 mm in width, and between 0,1 μm and 10 μm in thickness. The main structural materials for MEMS, micromachine, etc. have special features, such as typical dimensions of a few microns, material fabrication by deposition, and test piece fabrication by means of non-mechanical machining, including photolithography. The MEMS structures often have higher fundamental resonant frequency and higher strength than macro structures. To evaluate and assure the lifetime of MEMS structures, a fatigue testing method with ultra high cycles (up to 1012) loadings needs to be established. The object of the test method is to evaluate the mechanical fatigue properties of microscale materials in a short time by applying high load and high cyclic frequency bending stress using resonant vibration.

IEC 62047-12:2011 specifies a method for bending fatigue testing using resonant vibration of microscale mechanical structures of MEMS (micro-electromechanical systems) and micromachines. This standard applies to vibrating structures ranging in size from 10 μm to 1 000 μm in the plane direction and from 1 μm to 100 μm in thickness, and test materials measuring under 1 mm in length, under 1 mm in width, and between 0,1 μm and 10 μm in thickness. The main structural materials for MEMS, micromachine, etc. have special features, such as typical dimensions of a few microns, material fabrication by deposition, and test piece fabrication by means of non-mechanical machining, including photolithography. The MEMS structures often have higher fundamental resonant frequency and higher strength than macro structures. To evaluate and assure the lifetime of MEMS structures, a fatigue testing method with ultra high cycles (up to 1012) loadings needs to be established. The object of the test method is to evaluate the mechanical fatigue properties of microscale materials in a short time by applying high load and high cyclic frequency bending stress using resonant vibration.

IEC 62047-12:2011 is classified under the following ICS (International Classification for Standards) categories: 27.120.20 - Nuclear power plants. Safety; 31.080.99 - Other semiconductor devices. The ICS classification helps identify the subject area and facilitates finding related standards.

You can purchase IEC 62047-12:2011 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of IEC standards.

Standards Content (Sample)


IEC 62047-12 ®
Edition 1.0 2011-09
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Semiconductor devices – Micro-electromechanical devices –
Part 12: Bending fatigue testing method of thin film materials using resonant
vibration of MEMS structures
Dispositifs à semiconducteurs – Dispositifs microélectromécaniques –
Partie 12: Méthode d'essai de fatigue en flexion des matériaux en couche mince
utilisant les vibrations à la résonance des structures à systèmes
microélectromécaniques (MEMS)
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
 Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
 IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
 Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
 Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
 Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
 Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
 Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
 Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 62047-12 ®
Edition 1.0 2011-09
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Semiconductor devices – Micro-electromechanical devices –
Part 12: Bending fatigue testing method of thin film materials using resonant
vibration of MEMS structures
Dispositifs à semiconducteurs – Dispositifs microélectromécaniques –
Partie 12: Méthode d'essai de fatigue en flexion des matériaux en couche mince
utilisant les vibrations à la résonance des structures à systèmes
microélectromécaniques (MEMS)
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX U
ICS 31.080.99 ISBN 978-2-88912-689-7

– 2 – 62047-12  IEC:2011
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 Test equipment . 7
4.1 General . 7
4.2 Actuator . 8
4.3 Sensor . 8
4.4 Controller . 8
4.5 Recorder . 9
4.6 Parallel testing . 9
5 Specimen . 9
5.1 General . 9
5.2 Resonant properties . 9
5.3 Test part. 9
5.4 Specimen fabrication . 9
6 Test conditions . 9
6.1 Test amplitude. 9
6.2 Load ratio . 10
6.3 Vibration frequency . 10
6.4 Waveform . 10
6.5 Test time . 10
6.6 Test environment. 10
7 Initial measurement . 10
7.1 Reference strength measurement . 10
7.2 Frequency response test . 11
8 Test . 11
8.1 General . 11
8.2 Initial load application . 11
8.3 Monitoring . 12
8.4 Counting the number of cycles . 12
8.5 End of the test . 12
8.6 Recorded data . 12
9 Test report. 12
Annex A (informative) Example of testing using an electrostatic device with an
integrated actuation component and displacement detection component . 14
Annex B (informative) Example of testing using an external drive and a device with an
integrated strain gauge for detecting displacement . 17
Annex C (informative) Example of electromagnetic drive out-of-plane vibration test
(external drive vibration test) . 20
Annex D (informative) Theoretical expression on fatigue life of brittle materials based
on Paris’ law and Weibull distribution . 23
Annex E (informative) Analysis examples. 27
Bibliography . 29

62047-12  IEC:2011 – 3 –
Figure 1 – Block diagram of the test method . 7
Figure A.1 – Microscope image of the specimen . 14
Figure A.2 – Block diagram of test equipment . 15
Figure B.1 – The specimens’ structure . 17
Figure B.2 – Block diagram of test equipment . 18
Figure C.1 – Specimen for out-of-plane vibration testing . 20
Figure C.2 – Block diagram of test equipment . 21
Figure E.1 – Example of fatigue test results for silicon materials . 27
Figure E.2 – Static strength and fatigue life of polysilicon plotted in 3D . 28

– 4 – 62047-12  IEC:2011
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
SEMICONDUCTOR DEVICES –
MICRO-ELECTROMECHANICAL DEVICES –

Part 12: Bending fatigue testing method of thin film materials
using resonant vibration of MEMS structures

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62047-12 has been prepared by subcommittee 47F: Micro-
electromechanical systems, of IEC technical committee 47: Semiconductor devices.
The text of this standard is based on the following documents:
FDIS Report on voting
47F/80/FDIS 47F/90/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

62047-12  IEC:2011 – 5 –
A list of all parts of IEC 62047 series, under the general title Semiconductor devices –
Microelectromechanical devices, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
– 6 – 62047-12  IEC:2011
SEMICONDUCTOR DEVICES –
MICRO-ELECTROMECHANICAL DEVICES –

Part 12: Bending fatigue testing method of thin film materials
using resonant vibration of MEMS structures

1 Scope
This part of IEC 62047 specifies a method for bending fatigue testing using resonant vibration
of microscale mechanical structures of MEMS (micro-electromechanical systems) and
micromachines. This standard applies to vibrating structures ranging in size from 10 µm to
1 000 µm in the plane direction and from 1 µm to 100 µm in thickness, and test materials
measuring under 1 mm in length, under 1 mm in width, and between 0,1 µm and 10 µm in
thickness.
The main structural materials for MEMS, micromachine, etc. have special features, such as
typical dimensions of a few microns, material fabrication by deposition, and test piece
fabrication by means of non-mechanical machining, including photolithography. The MEMS
structures often have higher fundamental resonant frequency and higher strength than macro
structures. To evaluate and assure the lifetime of MEMS structures, a fatigue testing method
with ultra high cycles (up to 10 ) loadings needs to be established. The object of the test
method is to evaluate the mechanical fatigue properties of microscale materials in a short
time by applying high load and high cyclic frequency bending stress using resonant vibration.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 62047-3:2006, Semiconductor devices – Micro-electromechanical devices – Part 3: Thin
film standard test piece for tensile testing
ISO 12107, Metallic materials – Fatigue testing – Statistical planning and analysis of data
3 Terms and definitions
For the purposes of this document the following terms and definitions apply
3.1
amplitude
one-half the algebraic difference between the maximum value and minimum value in a loading
cycle
3.2
load ratio
algebraic ratio of the maximum value and minimum value of the load of a cycle
3.3
S-N curve
plot of stress or strain (S) against the number of cycles (N) to failure

62047-12  IEC:2011 – 7 –
3.4
reference strength:
static strength or instantaneous failure strength
3.5
instantaneous failure strength
failure strength of quasi-static test or resonant vibration test at rapid amplitude growth

IEC  2064/11
Key
1 Specimen 2 Test part
3 Actuator 4 Sensor
5 Controller 6 Recorder
7 Force 8 Displacement or strain
9 Amplitude and frequency
Figure 1 – Block diagram of the test method
4 Test equipment
4.1 General
The test equipment shall be capable of generating resonant vibration with constant amplitude
and stable frequency to the test structure. A block diagram of the test equipment is shown in
Figure 1. The test equipment consists of an actuator for oscillation, a sensor for amplitude
detection, a controller for maintaining the resonant vibration at a constant amplitude, and a
recorder for monitoring.
The amplitude control method is classified as follows.
a) Constant strain control
Applied strain in the test part is maintained at constant. It can be applied for elastic or
inductile materials.
– 8 – 62047-12  IEC:2011
b) Constant stress control
Applied stress in the test part is maintained at constant. Load monitoring and closed loop
control is crucial for the method.
4.2 Actuator
The actuator shall be capable of applying oscillation force of the necessary amplitude and
frequencies along the required direction. Various kind of actuators can be used, e.g.,
electrostatic, piezoelectric, thermal, and electromagnetic actuators. The actuator may be
installed in the test structure, as discussed in 5.1.
4.3 Sensor
The sensor shall be capable of measuring the movement of the specimen to determine the
stress amplitude (for constant stress amplitude testing) or the strain amplitude (for constant
strain amplitude testing) to the test part of the specimen.
The sensor and its associated electronics shall be accurate to within 1 % of the range of the
stress or strain amplitude.
The sensor should measure the movement continuously, in order to maintain a constant
vibration and detect failure effectively. If the specimen is an elastic material and will not show
the change in the vibrating properties, however, it is permissible to measure the movement at
regular time intervals.
The movement is detected by measuring displacement of the test structure or the stress or
strain in the test structure. Clause A.2 shows a method for detecting rotational displacement
of the mass from changes in capacitance. Clause B.2 shows a method using a strain gauge
integrated in the specimen. Clause C.2 shows a method for detecting displacement of the
mass using a non-contact displacement gauge.
4.4 Controller
The controller shall be capable of generating the oscillation signal to the actuator from the
movement signal from the sensor, in order to maintain the required resonant vibration. During
testing, the amplitude and frequency of the specimen shall be maintained at a constant level.
One of the following methods should be applied for the specimen, depending on the vibration
characteristics.
a) Closed loop method
The frequency and amplitude of the oscillation signal applied to the specimen shall be
controlled to follow changes in the resonant frequency. In most cases, the signal applied to
the actuator is generated from the movement signal of the specimen. A self-excited oscillation
circuit or phase-locked loop circuit can be used as a means for maintaining the resonant
frequency. An automatic gain control circuit (AGC) can also be used to maintain a constant
amplitude by changing the amplitude of the oscillation signal based on the detected amplitude.
b) Open loop method
Elastic or inductile materials that show a linear response but no plastic deformation may be
tested using an open loop method. This test may be performed by stopping at regular
intervals and measuring the resonant characteristics, or by actuating the test structure from
the start to the end of testing at a predetermined resonance frequency and oscillation signal
amplitude.
The stability of the frequency and amplitude shall be maintained throughout the test to within
± 3 % of the desired value.
62047-12  IEC:2011 – 9 –
4.5 Recorder
The test equipment shall include a recorder for collecting the “record data” indicated in 8.6.
4.6 Parallel testing
The test may be conducted in parallel with a number of equipment units. In this case, steps
should be taken to eliminate mutual electrical or mechanical interference among the
equipment units.
5 Specimen
5.1 General
The specimen shall be capable of applying a constant and high-load amplitude to the test part
via resonant vibration. Examples of specific structures are shown in the Clauses A.1, B.1, and
C.1.
It is permissible to integrate a mechanism in the specimen for actuating or for sensing the
movement of the specimen. An example of a structure integrating mechanisms for actuation
and detecting amplitude is shown in Annex A.1. An example of a structure integrating a
mechanism for detecting amplitude only is shown in Annex B.1.
5.2 Resonant properties
The specimen shall have resonance characteristics that enable the application of the required
deformation (mode of vibration) in the specific frequency (resonance frequency) of the
specimen. The resonant frequency should preferably be more than 1 000 Hz, in order to
obtain a large number of the cycles in a short time. The quality factor of the specimen should
be more than 100, in order to obtain a large amplitude. Steps should be taken to ensure,
within this resonance frequency, that the specimen will not vibrate in a vibration mode
different from that used in the test. For example, there should be no other resonant modes
close to the mode used for testing.
5.3 Test part
The specimen shall have a test part in which stress sufficient to induce failure occurs. When
the test is performed to evaluate the reliability of the actual device, the deformation in the test
part at resonant vibration (in-plane and out-of-plane bending) shall be the same as that of the
actual device. If only low stress can be applied to a structure similar to the actual device, a
notch or another means may be introduced to concentrate the stress in the targeted section of
the test part.
5.4 Specimen fabrication
Refer to Clause 5 of IEC 62047-3 when manufacturing the test part of the specimen. The
specimen should be fabricated by the same method as the target MEMS device for reliability
evaluation is fabricated. Furthermore, the same shapes, dimensions, and multilayer film
structures should be used.
6 Test conditions
6.1 Test amplitude
The test amplitude should be specified from the appropriate reference strength of the
specimen. The reference strength should be determined through the methods in 7.1. One of
the following procedures should be chosen for determining the test amplitude during testing,
based on the reference strength.

– 10 – 62047-12  IEC:2011
a) Constant amplitude of 100 % of the reference strength:
to evaluate the fatigue life at a certain amplitude.
b) Decrease the amplitude gradually from a high level:
for obtaining an S-N curve in a short time.
c) Increase the amplitude gradually from a low level:
for obtaining an S-N curve when the number of test parts is limited.
As a reference for determining the test amplitude, example of experimental data and analysis
of fatigue testing for silicon are shown in Annex D. For details on the testing of metal
materials, refer to ISO 12107.
The decrease and increase step of the test amplitude for the procedures b) and c) should be
selected preferably close to the standard deviation of measured reference strength.
6.2 Load ratio
The load ratio of the test method can be taken to be -1, as the quality factor (Q) of the
resonant vibration is high enough (10 or more) to achieve an amplitude too high to apply by
(quasi-)static testing methods.
6.3 Vibration frequency
The frequency shall be the resonant mode at which the test part is in the required stress state
specified in 5.3, or a frequency close to it.
6.4 Waveform
The waveform of the displacement of the specimen and the stress and strain of the test part
can be regarded as sinusoidal, irrespective of the actuating waveform
6.5 Test time
The test time shall be specified as the time at which the test ends, even if the specimen has
not failed by that time. The test time can be determined as the number of the test cycles,
based on the vibration frequency. For tests conducted on materials with lifetime
characteristics which are frequency-independent, such as silicon, the test cycles are chosen
as the stress cycles applied on the actual devices in their lifetimes. See Annex D.
6.6 Test environment
The test environment should be maintained at a constant temperature and humidity.
7 Initial measurement
7.1 Reference strength measurement
The reference strength shall be measured prior to the fatigue test. Specimens used for
measurement of the reference strength should be made of the same materials, and by the
same processes, as the test part to be tested. Care shall be taken when using a specimen of
a different shape. If such a specimen is used, it should show the same failure mode, and the
size effect on the measured strength should be considered.
The reference strength should be determined using one of the following tests.
a) Quasi-static test
62047-12  IEC:2011 – 11 –
The failure strength measured by conducting quasi-static testing is set as the reference
strength.
b) Instantaneous fatigue test
The maximum amplitude in the instantaneous fatigue test is set as the reference strength. In
this test, the amplitude is rapidly increased up to the point of specimen failure by the same
method used for the fatigue test. This method may be chosen when it is difficult to use a
specimen of a different shape, or when it is difficult to apply a static load.
c) Stress analysis
The reference strength is determined using either simulation or theoretical analysis. This
method can be chosen when a reference strength is difficult to determine experimentally. The
amplitude at which the maximum stress in the specimen reaches the failure strength is set as
the reference strength. The failure strength can be taken from published papers or other
available data. The reported strength should be chosen carefully, as some materials have
size effect in failure strength and environmental effects under variable temperatures, humidity
levels, and so on. It is thus desirable to refer to the strength values in the literature in order to
keep conditions as close as possible to those in the life test to be conducted.
Given the large variation in the strength of brittle materials such as single crystal silicon, it is
preferable to obtain strength data for no less than 10 specimens when measuring the
reference strength experimentally, and to adopt a statistically processed value (for example,
50 % failure stress from Weibull analysis or an arithmetical average) as the reference for
stress or strain in the resonant oscillation test.
7.2 Frequency response test
The resonant properties of the specimens shall be measured prior to the fatigue test. When
the resonant properties vary among specimens and the controller needs tuning, the resonant
properties of all of the specimens should be measured.
The frequency response test is used to measure the resonant properties. The oscillation
signal is applied from a function generator and the frequency of the signal is swept around the
expected resonant properties to find the actual resonant frequency. The load applied in this
response test shall be small enough to ensure that the measurements for the fatigue test are
unaffected. If the effect cannot be ignored, the number of load cycles applied in this response
test should preferably be added to the fatigue test data.
8 Test
8.1 General
The fatigue test shall be conducted by applying resonant oscillation at the predetermined
oscillation amplitude to the specimen. The test ends when the specimen fails or the
predetermined test time is reached.
8.2 Initial load application
The increasing rate of the amplitude should be specified properly at the start of the fatigue
test. Because the test is conducted in resonance and the quality factor is high, the amplitude
cannot reach the test amplitude without delay. If the amplitude increases too rapidly, it can
result in an overshooting of the amplitude and unexpected failure at the start of the test. If, on
the other hand, too much time is allowed for the increase in amplitude, the test result can be
affected. The initial load applied in these procedures should be carefully controlled to ensure
that measurement results of the lifetime test are unaffected. When some effect is conceivable,
the procedures for increasing the amplitude should be described in the test report.

– 12 – 62047-12  IEC:2011
8.3 Monitoring
The vibration of the specimen shall be monitored continuously during the test to detect the
specimen failure. One method for this test monitoring is to monitor the vibration frequency
and/or amplitude. It is also desirable to record the changes in the vibration frequency and
amplitude at proper time intervals. If the system lacks a monitoring function, the specimen
may be monitored by stopping the fatigue test at certain intervals of time and conducting the
frequency response test in 7.2.
8.4 Counting the number of cycles
The number of cycles of the fatigue test shall be counted using a counter. Alternatively, the
cycles may be calculated by multiplying the vibration frequency by the time from the start of
testing.
8.5 End of the test
The test shall end at the point of specimen failure, or when a predetermined loading time or a
predetermined number of cycles has elapsed.
Specimen failure is defined as the following:
a) fracture of the test part;
b) a certain percentage change in the amplitude;
c) a certain change in the oscillating frequency.
8.6 Recorded data
The failure of the specimen shall be recorded. The oscillation amplitude and frequency of the
specimen and the temperature and humidity of the testing environment should be measured at
certain intervals of time during the test.
9 Test report
The test report shall include the following information.
• Mandatory
a) reference to this International Standard, i.e. IEC 62047-12
b) test piece material
− in the case of a single crystal: crystallographic orientation
c) method and details of test piece fabrication
− method of thin film deposition
− fabrication processes
− heat treatment (annealing) conditions
d) shape and dimensions of test piece
e) test equipment
− oscillation method (self-oscillation, external oscillation)
− initial load application method
− amplitude control method
− test monitoring method (amplitude, frequency, number)

62047-12  IEC:2011 – 13 –
f) fatigue test conditions
− reference strength, and its measurement method
− mean stress (in the case of displacement control, mean displacement)
− stress amplitude (in the case of displacement control, displacement amplitude)
− load ratio
− testing environment (temperature and relative humidity)
− wave form (sinusoidal)
− frequency
g) fatigue test result
− number of samples
− number of applied cycles to failure. If the test piece is not fractured during a
predetermined number of cycles, the number of cycles and the description “no
failure” should be noted.
− definition (type) of failure
• Optional
a) purpose of the test
− motivation or object
b) microstructure
− in the case of polycrystalline thin film: texture and grain size
c) internal stress
d) mask design
− resolution of mask drawing and lithography
e) surface roughness of test piece
− photographs of the finished test part, along with any surface treatment (cleaning
procedure)
f) brief description of fracture characteristics
g) detailed test results
− S-N curve (S is peak stress or stress amplitude)
− fatigue strength, statistical processing (fatigue probability)
− amplitude history
− fractograph.
– 14 – 62047-12  IEC:2011
Annex A
(informative)
Example of testing using an electrostatic device with an integrated
actuation component and displacement detection component

A.1 Specimen
The specimen consisted of a flexible beam test part and a fan-shaped mass fabricated by dry
etching a thin film of single crystal silicon as shown in Figure A.1. One end of the flexible
beam is fixed to the mass and the other is fixed to a substrate. An electrostatic comb-drive
actuator is connected to the mass, and in-plane bending can occur in the flexible beam. A
comb electrode attached to the mass outputs a signal proportional to the displacement, and
the mass has a deflection scale that can be read by microscope. Since the test material is
used for the electrostatic actuator and sensor, the test material is a conductive material.
The resonance frequency of the specimen is determined by the moment of inertia of the mass
and the flexural rigidity of the flexible beam. The fundamental resonance frequency of the in-
plane vibration of the test part varied between 38,75 kHz and 39,71 kHz. This variation
resulted mainly from the less-than-uniform thickness of the thin film formed on the structure.
Based on a measurement of the displacement response when an external signal was applied
to the actuator, the Q value of the oscillator in the atmosphere was estimated to be 370. To
increase the Q value of the oscillator, the bottom surface of the oscillator substrate was
removed by etching. No resonance other than first in-plane vibration was observed in nearby
frequencies. The test was performed at the resonance frequency of the in-plane vibration
mode.
Dimensions in micrometres
3 2
IEC  2065/11
Key
1 Resonator 2 Actuator
3 Sensor 4 Test piece
Figure A.1 – Microscope image of the specimen
The test part was composed of a single crystal silicon with an SOI active layer of 10 µm in
width, 30 µm in length, and 5 µm in thickness, and etched surfaces at the sides. With in-plane
bending deformation, the stress on the sidewall surfaces was a potential cause of failure. To
eliminate the influence of surface roughness on the sidewall, steps were taken to obtain a

62047-12  IEC:2011 – 15 –
side surface as smooth as possible by lithography and etching. As it was conjectured that
sufficient stress to cause failure could not be applied to test parts with a beam structure only,
a notch of 4 µm deep was introduced into the middle of one side of the test part. The tip of the
notch was a half circle with a radius of 0,5 µm, and the behavior of the stress concentration
was evaluated by the finite element method.
A.2 Test equipment
The test equipment for applying resonant oscillation to the specimen consisted of an electric
circuit only, as the actuation and detection mechanisms were built into the specimen. The
block diagram of the test equipment is shown in Figure A.2. Resonant vibration was induced
in the specimen by a self-oscillation method.
2 3
4 6 7
12 13
IEC  2066/11
Key
1 Test piece 2 Actuator
3 Sensor 4 Driver
5 Oscillating circuit 6 Automatic gain controller
7 Frequency-voltage converter 8 Oscilloscope
9 Control PC 10 Oscillating waveform monitor
11 Amplitude reference 12 Amplitude output
13 Frequency output
Figure A.2 – Block diagram of test equipment
Eight sets of test equipment were manufactured, to work in parallel. When the power supply
and circuit board are shared in this type of setup, stable oscillation can be disrupted by
electrical interference. Therefore, in conducting the tests in parallel, the electrical coupling
was reduced by selecting specimens of slightly different frequencies.
The actuation component amplifies a drive signal whose amplitude and phase are adjusted
from the displacement signal to realize feedback oscillation. The actuation signal is amplified
with a biased high voltage amplifier and applied to the electrostatic comb actuator. The drive
signal voltage during stable oscillation was V = 20 V to V = 40 V.
pp pp
The displacement amplitude of the specimen was measured by detecting the capacitance of
the comb electrodes. The capacitance of the comb was measured with a charge amplifier, and
an electrical signal proportional to the angular displacement was obtained. The amplitude was
observed simultaneously by reading the deflection scale by microscope, thus enabling
calibration of the electrical signal.
As the force applied to the test part is immeasurable in this technique, the stress applied to
the test part is evaluated by finite element analysis based on the measured angular
displacement of the mass.
– 16 – 62047-12  IEC:2011
With the use of the self-excited oscillation circuit, the specimen vibrates at the resonance
frequency. To keep the displacement of the specimen at a constant level, an automatic gain
controller (AGC) is built into the oscillation circuit. The amplitude of the specimen can be
controlled by software, as the reference voltage of the AGC is controlled using the analog
voltage output from a computer.
If the value set for the AGC amplitude of the vibration control circuit is raised quickly, the
delay in mechanical resonance due to the high Q value can destabilize the oscillation.
Unstable vibration starts after several dozen milliseconds, and a few milliseconds later the
test part will fail due to vibration overshoot. To prevent this, the value set for the AGC
amplitude was raised linearly over 10 s by computer control. This approach resulted in an
increase in the oscillation amplitude with stable vibration, and the setting value was reached
without overshoot. The time required to raise the amplitude was short in comparison with the
fatigue life, and thus was excluded from the test results.
With this test method, an electric displacement signal is the output to be observed. As long as
this signal is sinusoidally stable, the specimen can be presumed to be vibrating stably,
without failure. When the test part fails, the signal shows a sudden break in the sinusoidal
wave. The waveform of the displacement signal was observed over a short time with an
oscilloscope, while the long-term displacement signal was recorded by taking the detected
amplitude of the AGC at set intervals. The temperature and humidity were measured at the
same time.
The measured amplitude signal and frequency signal were recorded every 1 s by an analog-
digital converter circuit to determine whether or not failure had occurred. In some tests, the
displacement signal at the moment of failure was recorded by a digital oscilloscope (recording
was triggered by a drop in the displacement signal).
A.3 Test conditions
Because of the difficulty of performing a static or quasi-static strength test, in this test system,
the reference amplitude for this specimen was determined by preliminary fatigue testing. The
stress ratio was taken as –1, since the same displacement was consistently observed at both
sides in the microscope observation of the amplitude scale.
The vibration frequency was measured with a frequency-voltage convertor. Frequency
changes higher than the resolution (about 200 Hz) were not observed at any point during the
test. The test time was 168 h. The test was conducted with the test parts placed in a
temperature- and humidity controlled chamber (temperature 23,0 °C ± 0,1 °C, humidity
49 % RH to 51 % RH and 24 % RH to 27 % RH).
A.4 Initial measurement
The only initial measurement was a frequency response test of the specimen. The test was
performed by applying a sinusoidal signal to the actuator from an external oscillator and
observing the displacement output. The resonance frequency of all specimens was inspected
prior to the lifetime test. In addition, self-oscillation and stability were checked over a short
time (about 1 min) with the specimens configured as a feedback circuit. The oscillation
amplitudes for these initial measurements were kept below the minimum amplitude for the
lifetime tests, and thus were not thought to have effects on the test results. None of the
specimens that showed stable vibration failed during the initial measurement.

62047-12  IEC:2011 – 17 –
Annex B
(informative)
Example of testing using an external drive and a device
with an integrated strain gauge for detecting displacement
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

IEC 62047-12:2011은 MEMS(micro-electromechanical systems) 및 마이크로머신의 마이크로스케일 기계 구조물을 공진 진동을 사용하여 구부림 피로 시험하는 방법을 규정한다. 이 표준은 평면 방향에서 10μm에서 1,000μm, 두께에서 1μm에서 100μm의 크기 범위에 따라 운동하는 구조물에 적용되며, 테스트 재료는 길이가 1mm 미만, 폭이 1mm 미만, 두께가 0.1μm에서 10μm 사이인 제품을 사용한다. MEMS, 마이크로머신 등의 주요 구조재료는 몇 마이크론의 특수한 차원, 즉 증착을 통한 재료 제작 및 포토리소그래피를 포함한 비기계 가공을 통한 테스트 조각 제작과 같은 특징을 가지고 있다. MEMS 구조물은 종종 대형 구조물에 비해 더 높은 기본 공진 주파수와 높은 강도를 가진다. MEMS 구조물의 수명을 평가하고 보장하기 위해서는 초고주기(10^12까지) 부하를 사용하는 피로 시험 방법을 개발해야 한다. 이 시험 방법의 목적은 공진 진동을 통해 고하중 및 고주기 수평응력을 가함으로써 짧은 시간 내에 마이크로스케일 재료의 기계적 피로 특성을 평가하는 것이다.

IEC 62047-12:2011は、MEMS(マイクロ電気機械システム)およびマイクロマシンのマイクロスケールの機械構造物の共振振動を利用した薄膜材料の曲げ疲労試験方法を規定しています。この規格は、平面方向では10μmから1,000μm、厚さでは1μmから100μmの範囲の振動構造物に適用され、テスト材料は長さ1mm未満、幅1mm未満、厚さ0.1μmから10μmの間のものを使用します。MEMS、マイクロマシンなどの主要な構造材料は、数マイクロンの特異な寸法、堆積による材料作製、およびフォトリソグラフィを含む非機械加工による試験部品作製などの特徴を持っています。MEMS構造物は通常、マクロ構造物よりも高い基本共振周波数と高い強度を持っています。MEMS構造物の耐久性を評価し確保するためには、超高周波数(最大10^12回)の負荷を処理する疲労試験方法が確立される必要があります。この試験方法の目的は、共振振動を利用して高荷重および高周期周波数の曲げ応力を適用することで、少ない時間でマイクロスケール材料の機械的な疲労特性を評価することです。

IEC 62047-12:2011 outlines a testing method for evaluating the bending fatigue of thin film materials using resonant vibration of microscale mechanical structures in MEMS. The standard applies to structures of sizes ranging from 10 μm to 1,000 μm in the plane direction and 1 μm to 100 μm in thickness. The test materials should have dimensions under 1 mm in length and width, and thickness between 0.1 μm and 10 μm. This method is necessary to assess the durability of MEMS structures, which often have smaller dimensions, are fabricated through deposition, and require non-mechanical machining for test piece fabrication. MEMS structures typically possess higher resonant frequencies and strength compared to macro structures. The goal is to establish a fatigue testing approach that can handle ultra high cycle loadings (up to 10^12 cycles) and quickly evaluate the mechanical fatigue properties of microscale materials through high load and high cyclic frequency bending stress applied via resonant vibration.