Amendment 1 - Safety of laser products - Part 2: Safety of optical fibre communication systems (OFCS)

Amendement 1 - Sécurité des appareils à laser - Partie 2: Sécurité des systèmes de télécommunication par fibres optiques (STFO)

General Information

Status
Published
Publication Date
08-Nov-2006
Current Stage
DELPUB - Deleted Publication
Completion Date
16-Mar-2021
Ref Project

Relations

Buy Standard

Standard
IEC 60825-2:2004/AMD1:2006 - Amendment 1 - Safety of laser products - Part 2: Safety of optical fibre communication systems (OFCS)
English and French language
19 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NORME CEI
INTERNATIONALE
IEC



60825-2
INTERNATIONAL


2004
STANDARD


AMENDEMENT 1
AMENDMENT 1

2006-11

Amendement 1
Sécurité des appareils à laser –
Partie 2:
Sécurité des systèmes de télécommunication
par fibres optiques (STFO)

Amendment 1
Safety of laser products –
Part 2:
Safety of optical fibre communication
systems (OFCS)
© IEC 2006 Droits de reproduction réservés ⎯ Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
K
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue

---------------------- Page: 1 ----------------------
– 2 – 60825-2 Amend. 1 © CEI:2006
AVANT-PROPOS
Cet amendement a été établi par le comité d’études 76 de la CEI: Sécurité des rayonnements
optiques et matériels laser.
Le texte de cet amendement est issu des documents suivants:
FDIS Rapport de vote
76/346/FDIS 76/353/RVD

Le rapport de vote indiqué dans le tableau ci-dessus donnent toute information sur le vote
ayant abouti à l'approbation de cet amendement.
Le comité a décidé que le contenu de cet amendement et de la publication de base ne sera
pas modifié avant la date de maintenance indiquée sur le site web de la CEI sous
"http://webstore.iec.ch" dans les données relatives à la publication recherchée. A cette date,
la publication sera
• reconduite,
• supprimée,
• remplacée par une édition révisée, ou
• amendée.

_____________

Page 20
4.4 Connecteurs de câbles
Remplacer le texte existant des Paragraphes 4.4.1, 4.4.2 et 4.4.3 par ce qui suit.
4.4.1 Zones à accès non limité
Dans les zones à accès non limité, si le niveau du rayonnement accessible dépasse
– le niveau de risque 2 dans le domaine des longueurs d'onde de 400 nm à 700 nm, ou
– le niveau de risque 1 pour tous les autres domaines de longueurs d'onde,
des moyens appropriés doivent alors limiter l'accès au rayonnement provenant du connecteur.
NOTE Dans une zone à accès non limité, les niveaux de risque autorisés les plus élevés sont de niveau de risque
2M, pour le domaine des longueurs d'onde de 400 nm à 700 nm, et le niveau de risque 1M, pour tous les autres
domaines de longueurs d'onde (voir 4.9.1).

---------------------- Page: 2 ----------------------
60825-2 Amend. 1 © IEC:2006 – 3 –
FOREWORD
This amendment has been prepared by IEC technical committee 76: Optical radiation safety
and laser equipment.
The text of this amendment is based on the following documents:
FDIS Report on voting
76/346/FDIS 76/353/RVD

Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

_____________

Page 21
4.4 Cable connectors
Replace the existing text of Subclauses 4.4.1, 4.4.2 and 4.4.3 as follows.
4.4.1 Unrestricted locations
In unrestricted locations, if the accessible radiation level exceeds:
– hazard level 2 within the wavelength range 400 nm to 700 nm, or
– hazard level 1 in all other cases,
then suitable means shall limit access to the radiation from the connector.
NOTE In an unrestricted location the highest hazard levels permitted are hazard level 2M for the wavelength
range 400 nm to 700 nm and hazard level 1M in all other cases (see 4.9.1)

---------------------- Page: 3 ----------------------
– 4 – 60825-2 Amend. 1 © CEI:2006
4.4.2 Zones à accès limité
Dans les zones à accès limité, si le niveau du rayonnement accessible dépasse
– le niveau de risque 2M dans le domaine des longueurs d'onde de 400 nm à 700 nm, ou
– le niveau de risque 1M pour tous les autres domaines de longueurs d'onde,
des moyens appropriés doivent alors limiter l'accès au rayonnement provenant du connecteur.
NOTE Dans une zone à accès limité, le plus haut niveau de risque autorisé est le niveau de risque 1M, 2M ou 3R,
le plus élevé étant retenu (voir 4.9.2).
4.4.3 Zones à accès contrôlé
Dans les zones à accès contrôlé, si le niveau du rayonnement accessible dépasse
– le niveau de risque 2M dans le domaine des longueurs d'onde de 400 nm à 700 nm, ou
– le niveau de risque 1M pour tous les autres domaines de longueurs d'onde,
des moyens appropriés doivent alors limiter l'accès au rayonnement provenant du connecteur.
NOTE Dans une zone contrôlée, le plus haut niveau de risque autorisé est le niveau de risque 3B (voi
...