IEC 61347-1
®

Edition 2.0 2012-11
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
AMENDMENT 2
AMENDEMENT 2

Lamp controlgear –
Part 1: General and safety requirements

Appareillages de lampes –
Partie 1: Exigences générales et exigences de sécurité


IEC 61347-1:2007/A2:2012

---------------------- Page: 1 ----------------------
THIS PUBLICATION IS COPYRIGHT PROTECTED
Copyright © 2012 IEC, Geneva, Switzerland

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.


Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni
utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les
microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch

About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.

Useful links:

IEC publications search - www.iec.ch/searchpub Electropedia - www.electropedia.org
The advanced search enables you to find IEC publications The world's leading online dictionary of electronic and
by a variety of criteria (reference number, text, technical electrical terms containing more than 30 000 terms and
committee,…). definitions in English and French, with equivalent terms in
It also gives information on projects, replaced and additional languages. Also known as the International
withdrawn publications. Electrotechnical Vocabulary (IEV) on-line.

IEC Just Published - webstore.iec.ch/justpublished Customer Service Centre - webstore.iec.ch/csc
Stay up to date on all new IEC publications. Just Published If you wish to give us your feedback on this publication
details all new publications released. Available on-line and or need further assistance, please contact the
also once a month by email. Customer Service Centre: csc@iec.ch.


A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.

Liens utiles:

Recherche de publications CEI - www.iec.ch/searchpub Electropedia - www.electropedia.org
La recherche avancée vous permet de trouver des Le premier dictionnaire en ligne au monde de termes
publications CEI en utilisant différents critères (numéro de électroniques et électriques. Il contient plus de 30 000
référence, texte, comité d’études,…). termes et définitions en anglais et en français, ainsi que
Elle donne aussi des informations sur les projets et les les termes équivalents dans les langues additionnelles.
publications remplacées ou retirées. Egalement appelé Vocabulaire Electrotechnique
International (VEI) en ligne.
Just Published CEI - webstore.iec.ch/justpublished
Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications de la CEI.
Just Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur
Disponible en ligne et aussi une fois par mois par email. cette publication ou si vous avez des questions
contactez-nous: csc@iec.ch.

---------------------- Page: 2 ----------------------
IEC 61347-1

®


Edition 2.0 2012-11




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE




AMENDMENT 2

AMENDEMENT 2





Lamp controlgear –

Part 1: General and safety requirements




Appareillages de lampes –

Partie 1: Exigences générales et exigences de sécurité
















INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE

PRICE CODE
INTERNATIONALE

CODE PRIX V


ICS 29.140.99 ISBN 978-2-83220-477-1



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 3 ----------------------
– 2 – 61347-1 Amend.2 © IEC:2012
FOREWORD
This amendment has been prepared by subcommittee 34C: Auxiliaries for lamps, of IEC
technical committee 34: Lamps and related equipment.
The text of this amendment is based on the following documents:
FDIS Report on voting
34C/1023/FDIS 34C/1029/RVD

Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the stability date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
_____________

Add, after the Foreword, the following new text:
Introduction
Work is currently underway to modify creepage distances and clearances requirements
regarding:
• working voltages with operating frequencies up to 30 kHz and with higher operating
frequencies then 30 kHz;
• impulse and resonance ignition;
• basic, supplementary and reinforced insulation;
• insulation between circuits;
• coated or potted controlgear.
This information is expected to be incorporated into the future Edition 3 of IEC 61347-1.

1 Scope
Replace the fifth, sixth and seventh paragraphs by the following new paragraph:
Particular requirements for controlgears providing safety extra low voltage (from now on
SELV) are given in Annex L.

---------------------- Page: 4 ----------------------
61347-1 Amend.2 © IEC:2012 – 3 –
2 Normative references
Add the following new references:
IEC 60065:2001, Audio, video and similar electronic apparatus – Safety requirements
IEC 60085:1987, Electrical insulation – Thermal classification and designation
IEC 60216 (all parts), Electrical insulating materials – Properties of thermal endurance
IEC 60598-2 (all Parts 2), Luminaires – Part 2: Particular requirements.
IEC 60664-1:2007, Insulation coordination for equipment within low-voltage systems – Part 1:
Principles, requirements and tests
IEC 60884-2-4, Plugs and socket-outlets for household and similar purposes – Part 2-4:
Particular requirements for plugs and socket outlets for SELV
IEC 60906-3, IEC System of plugs and socket-outlets for household and similar purposes –
Part 3: SELV plugs and socket-outlets, 16 A 6 V, 12 V, 24 V, 48 V, a.c. and d.c.
IEC 60950-1, Information technology equipment – Safety – Part 1: General requirements
IEC 61558-1:2005, Safety of power transformers, power supplies, reactors and similar
products – Part 1: General requirements and tests
IEC 61558-2-6:2009, Safety of transformers, reactors, power supply units and similar products
for supply voltages up to 1 100 V – Part 2-6: Particular requirements and tests for safety
isolating transformers and power supply units incorporating safety isolating transformers
IEC 61558-2-16:2009, Safety of transformers, reactors, power supply units and similar
products for supply voltages up to 1 100 V – Part 2-16: Particular requirements and tests for
switch mode power supply units and transformers for switch mode power supply units
Replace the references to IEC 60317-0-1:1997 and IEC 60598-1:2003 by the following:
IEC 60317-0-1:2008, Specifications for particular types of windings wires – Part 0-1: General
requirements – Enamelled round copper wire
IEC 60598-1:2008, Luminaires – Part 1: General requirements and tests

3 Terms and definitions
3.23
functional earthing (ground)
Replace the existing Notes 1 and 2 of the existing definition by the following Note to entry:
Note 1 to entry: In some cases, functional earthing may be necessary to facilitate starting and/or to avoid radio
interference.

Add, after Definition 3.26, the following new definitions:

---------------------- Page: 5 ----------------------
– 4 – 61347-1 Amend.2 © IEC:2012
3.27
extra-low voltage
ELV
voltage which does not exceed 50 V a.c. or 120 V ripple free d.c. between conductors, or
between any conductor and earth (voltage band 1 of IEC 60449:1973)
Note 1 to entry: “Ripple free” is conventionally defined for sinusoidal ripple voltage as a ripple content of not more
than 10 % r.m.s. The maximum peak value does not exceed 140 V for a nominal 120 V ripple-free d.c. system.
3.28
safety extra low voltage
SELV
ELV in a circuit which is isolated from the mains supply by insulation not less than that
between the primary and secondary circuits of a safety isolating transformer according to
IEC 61558-2-6
Note 1 to entry: Maximum voltage lower than 50 V a.c. r.m.s. or 120 V ripple free d.c. may be specified in
particular requirements, especially when direct contact with current-carrying parts is allowed.
Note 2 to entry: The voltage limit should not be exceeded at any load between full loads and no-load when the
source is a safety isolation transformer.
Note 3 to entry: “Ripple free” is conventionally an r.m.s. ripple voltage not more than 10 % of the d.c. component:
the maximum peak value does not exceed 140 V for a nominal 120 V ripple free d.c. system and 70 V for a nominal
60 V ripple free system.
3.29
body
term used in this standard as a general term which includes all accessible metal parts, shafts,
handles, knobs, grips and the like, accessible metal fixing screws and metal foil applied on
accessible surfaces of insulating material and does not include non-accessible metal parts
3.30
impulse withstand category
DEPRECATED: overvoltage category
numeral defining a transient overvoltage condition
Note 1 to entry: Impulse withstand categories I, II, III and IV are used. For detailed information, see IEC 60664-1
and IEC 60598-1.
3.31
class I lamp controlgear
independent controlgear in which protection against electric shock does not rely on basic
insulation only, but which includes an additional safety precaution in such a way that means
are provided for the connection of accessible conductive parts to the protective (earthing)
conductor in the fixed wiring of the installation in such a way that accessible conductive parts
cannot become live in the event of a failure of the basic insulation
Note 1 to entry: Class I lamp independent controlgear may have parts with double or reinforced insulation.
Note 2 to entry: Class I lamp independent controlgear may have parts in which protection against shock relies on
operation at safety extra-low voltage (SELV)
3.32
class II lamp controlgear
independent controlgear in which protection against electric shock does not rely on basic
insulation only, but in which additional safety precautions such as double insulation or
reinforced insulation are provided, there being no provision for protective earthing or reliance
upon installation conditions
3.33
class III lamp controlgear
independent controlgear in which protection against electric shock relies on supply at safety
extra-low voltage (SELV) and in which voltages higher than those of SELV are not generated

---------------------- Page: 6 ----------------------
61347-1 Amend.2 © IEC:2012 – 5 –
3.34
protective impedance device
component or assembly of components the impedance and construction of which are such as
to ensure that steady state touch current and charge are limited to a non-hazardous level
3.35
maximum working voltage
U
out
maximum occurring working voltage (r.m.s.) between the output terminals or between the
output terminals and earth, during normal or abnormal operating condition
Note 1 to entry: Transients and ignition voltages have to be neglected.
3.36
basic insulation
insulation of parts which provide protection against electrical shock under fault-free conditions
3.37
double insulation
insulation of parts with two layers of insulation which provide protection against electrical
shock under single fault condition
3.38
reinforced insulation
Insulation of parts which provide a degree of protection as double insulation

4 General requirements
Add, after the second paragraph, the following new paragraph:
Requirements for insulation materials used for double or reinforced insulation of controlgear
are specified in Annex N of this standard.
Add, after the third paragraph, the following new paragraph:
Built-in electronic controlgear with double or reinforced insulation shall comply additionally
with the requirements of Annex O.
Add, at the end of Clause 4, the following new paragraph:
Controlgears providing SELV shall comply with the additional requirements given in Annex L.
This includes especially insulation resistance, electric strength, creepage distances and
clearances between the primary and secondary circuit.

5 General notes on tests
Add, at the end of Subclause 5.3, the following new paragraph:
If the tests of 14.3 or 15.5 of IEC 61558-1:2005 have to made, three additional samples are
needed. These samples are used only for the test of 14.3 or 15.5 of IEC 61558-1:2005,
respectively.

---------------------- Page: 7 ----------------------
– 6 – 61347-1 Amend.2 © IEC:2012
7.1 Items to be marked
Add, after the first paragraph of Subclause 7.1, but before the alphabetical list, the following
new paragraph:
For controlgear without an enclosure, and classified as built-in (e.g. open printed circuit board
assembly), only items a) and b) are to be considered mandatory for marking on the
controlgear. Other mandatory markings required by the IEC 61347-2 part shall be provided as
information to be given either on the controlgear or made available in the manufacturer’s
catalogue or similar.
Replace the existing point f) by the following new point f):
f) The earthing terminals (if any) shall be identified by the symbol or .

These symbols shall not be placed on screws or other easily removable parts.
If the lamp control gear is market with an earthing symbol, the manufacturer’s instruction
shall contain the information whether it is permitted to use the control gear also without
connection to earth.
NOTE For the use of symbols, see IEC 60417.

Add, at the end of Subclause 7.1, the following new items, table and text:
s) Symbol indicating the kind of controlgear providing SELV.
t) The earthing terminals of an independent controlgear used for the connection of lamp
compartments (if any) shall be marked with the symbol:

This symbol shall not be placed on screws or other easily removable parts. The symbol size of
the earthing terminals of an independent controlgear used for the connection of lamp
compartments shall be at least 5 mm (over all, including letters).
u) Declaration of the maximum working voltage U (r.m.s.) between
out
• output terminals, or
• any output terminal and earth (if applicable)
in steps as described in Table 5.
Table 5 – Working voltage and U steps
out
Working voltage < 50 V < 500 V > 500 V
U in steps of 1 V 10 V 50 V
out

The highest of the specified voltage values shall be marked on the controlgear as “Output
working voltage = …V” or “U-OUT = …V” or “U = …V”.
out
NOTE 5 Item u) is not applicable to terminals with SELV-circuits as defined in IEC 61558-1.

---------------------- Page: 8 ----------------------
61347-1 Amend.2 © IEC:2012 – 7 –
9 Provisions for protective earthing
Replace the existing title and content of Clause 9 by the following:
9 Earthing
9.1 Provisions for protective earthing (Symbol: IEC 60417-5019 (2006-08))
Earthing terminals shall comply with the requirements of Clause 8. The electrical connection/
clamping means shall be adequately locked against loosening, and it shall not be possible to
loosen the electrical connection/clamping means by hand without the use of a tool. For
screwless terminals, it shall not be possible to loosen the clamping means/electrical
connection unintentionally.
All parts of an earthing terminal shall be such as to minimize the danger of electrolytic
corrosion resulting from contact with the earth conductor or any other metal in contact with
them.
The screw and the other parts of the earthing terminal shall be made of brass or other metal
no less resistant to corrosion, or material with a non-rusting surface and at least one of the
contact surfaces shall be bare metal.
Compliance is checked according to 7.2.3 of IEC 60598-1:2008.
9.2 Provisions for functional earthing (Symbol: IEC 60417-5018 (2011-07))
Functional earthing terminals shall comply with the requirements of Clause 8 and 9.1.
The functional earthing contact (potential) of a lamp controlgear shall be insulated from the
live parts by double or reinforced insulation.
9.3 Lamp controlgear with conductors for protective earthing by tracks on printed
circuit boards
If a printed circuit board track is used for earthing internally, in the independent, built-in or
integral lamp controlgear, it shall withstand the following test.
A current from an a.c. source of 25 A is passed for 1 min between the earthing terminal or
earthing contact via the track on the printed circuit board and each of the accessible metal
parts in turn.
After the test and after cooling the controlgear to ambient temperature, the requirements of
7.2.3 of IEC 60598-1:2008 shall apply.
9.4 Earthing of built-in lamp controlgear
It is allowed to earth built-in lamp controlgear by means of fixing the controlgear to earthed
metal of the luminaire.
For compliance, see 7.2 of IEC 60598-1:2008.
If a lamp controlgear has an earthing terminal, this terminal shall only be used for earthing the
built-in lamp controlgear.
Earthing of the luminaire or other equipment via the built-in lamp controlgear is not allowed.

---------------------- Page: 9 ----------------------
– 8 – 61347-1 Amend.2 © IEC:2012
9.5 Earthing via independent controlgear
9.5.1 Earth connection to other equipment
Independent lamp controlgear may have earthing terminals that allow the onward earth
connection to other equipment in the installation. For looping or through connection, the
2
conductor shall have a minimum cross-section of 1,5 mm and be of copper, or an equivalent
conductive material shall be used.
Protective earthing wires within the luminaire shall be in line with 5.3.1.1 and Clause 7 of
2
IEC 60598-1:2008. For looping-through, a minimum cross section of 1,5 mm is required.
Compliance is checked by inspection and measurement.
9.5.2 Earthing of the lamp compartments powered via the independent lamp
controlgear
Independent lamp controlgear may have earthing terminals that allow the earthing of the lamp
compartment, which are powered by this controlgear. In this case, the earth path between the
input and output earth terminals of the controlgear shall withstand the following test.
A current from an a.c. source of 25 A is passed for 1 min between the earthing terminal or
earthing contact (via the track on the printed circuit board, if used for protective earth) and
each of the accessible metal parts in turn.
After the test and after cooling the control gear at ambient temperature, a current of at least
10 A, derived from the source with a no-load voltage not exceeding 12 V, shall be passed
between the earthing terminal or earthing contact and each of the accessible metal parts in
turn. The voltage drop between the earthing terminal or earthing contact and the accessible
metal part shall be measured and the resistance shall be calculated from the current and the
voltage drop. In no case shall the calculated resistance value exceed 0,5 Ω.
The output earthing terminals to the lamp compartment shall be marked as described in 7.1 t).

10 Protection against accidental contact with live parts
Add, after Subclause 10.2, the following new subclauses:
10.3 For controlgears providing SELV, the accessible conductive parts shall be electrically
separated from live parts by at least double or reinforced insulation. There shall be no
connection between the output circuit and the body or the protective earthing circuit, if any.
Moreover, the construction shall be such that there is no possibility of any connection
between these circuits, either directly or indirectly, through other conductive parts, except by
deliberate action (see 10.4).
SELV output circuits shall be electrically separated from earth by at least basic insulation.
The expression “circuits” also covers windings of internal transformers (HF and others) of the
controlgear.
In controlgears providing ELV conductive parts are regarded as live parts and shall be
insulated accordingly.
Compliance is checked by inspection, relevant insulation tests and measurements. See also
Annex L.

---------------------- Page: 10 ----------------------
61347-1 Amend.2 © IEC:2012 – 9 –
10.4 Controlgears providing SELV may have accessible conductive parts in the SELV circuit;
if: the rated output voltage under load does not exceed 25 V r.m.s. or 60 V d.c. ripple free d.c.
where the voltage exceeds 25 V r.m.s. or 60 V ripple free d.c., the touch current does not
exceed:
– for a.c.: 0,7 mA (peak);
– for d.c.: 2,0 mA;
– the no-load output does not exceed 35 V peak or 60 V ripple free d.c.
NOTE The limits given are based on IEC 60364-4-41.
Compliance is checked by measuring the output voltage when steady conditions are
established, the controlgear being connected to rated supply voltage and rated frequency. For
the test under load the controlgear is loaded with a resistance which would give rated output
(current or wattage respectively) at rated output voltage. For controlgears with more than one
supply voltage, the requirements are applicable for each of the rated supply voltages.
The touch current is checked by measurement in accordance with Annex G from IEC 60598-1.
For controlgears providing SELV with rated output voltages or currents exceeding the values
given above at least one of the conductive parts in the SELV circuit shall be insulated by
insulation capable of withstanding a test voltage of 500 V r.m.s. for 1 min.
Accessible conductive parts separated by double or reinforced insulation, e.g. live parts and
the body or primary and secondary circuits, may be bridged (conductive bridged) by resistors
or Y2 capacitors provided they consists of at least two separate components of the same
rated value (resistance or capacitance) and are rated for the total working voltage and whose
impedance is unlikely to change significantly during the individual lifetime of the controlgear.
In addition, accessible conductive parts separated by double or reinforced insulation from live
parts, as above, may be bridged by a single Y1 capacitor.
Y1 or Y2 capacitors shall comply with relevant requirements of IEC 60384-14 and if resistors
are used they shall comply with the requirements of test (a) in 14.1 of IEC 60065:2001.

11 Moisture resistance and insulation
Replace, after the third paragraph after the note, the rest of the text of Clause 11 by the
following:
Insulation resistance shall be not less than 2 MΩ for basic insulation and 4 MΩ for double or
reinforced insulation between live parts and the body. For insulation between primary and
secondary circuits, in controlgear providing SELV, other values apply (see Annex L).
Insulation shall be adequate
a) between live parts and outer metal parts, including fixing screws and metal foil in contact
with outer insulating parts;
b) between live parts and control terminals, where relevant.
In the case of lamp controlgear having an internal connection or component between one or
more output terminals and the earth terminal, such a connection shall be removed during
this test.
For the test the input and output terminals shall be bonded together. Controlgear, having
insulation cover or envelope is wrapped with metal foil.

---------------------- Page: 11 ----------------------
– 10 – 61347-1 Amend.2 © IEC:2012
12 Electric strength
Replace the existing Table 1 by the following new Table 1:
Table 1 – Electric strength test voltage
Test voltage
Working voltage U
V
Basic insulation for voltages of SELV 500
Up to and including 50 V 500
Basic insulation 2 U + 1 000
Above 50 V up to and including 1 000 V Supplementary insulation 2 U + 1 000
Double or reinforced insulation 4 U + 2 000
Where both reinforced insulation and double insulation are used, care shall be taken that the voltage applied to
the reinforced insulation does not overstress the basic insulation or the supplementary insulation.
When testing the controlgear the input should be tested with a test voltage which corresponds with the supply
voltage and the output related part should be tested with a test voltage which corresponds with U .
out

Add the following sentence after Table 1:
For solid or thin sheet insulation used for double or reinforced insulation Annex N applies.

13 Termal endurance test for windings of ballasts
Add, after the second paragraph “Compliance is checked by the following test.", the following
new note:
NOTE 5 For windings included in controlgears providing SELV, see modifications specified in IEC 61558-1,
Annex U.

14 Fault conditions
Add, after the second paragraph, the following new text:
If a lamp controlgear marked with a protective earthing symbol and the manufacturer declared
in the instructions that the use of the controlgear without earthing contact is permitted then
the operation under fault conditions shall be made with and without earthing connection.
If a lamp controlgear marked with a functional earthing symbol and the manufacturer declared
in the instructions that the use of the controlgear without functional earthing contact is
permitted then the operation under fault conditions shall be made with and without earthing
connection.
Add, after the first paragraph of Subclause 14.1, the following new paragraphs:
Creepage and clearance distances below the values of Clause 16 are not allowed between
live parts and accessible metal parts.

---------------------- Page: 12 ----------------------
61347-1 Amend.2 © IEC:2012 – 11 –
The test shall be carried out on one item for each fault condition. If one of the items fails, the
test shall be repeated with three new items, none of which shall fail.
Delete the existing NOTE.

Subclause 14.5 of Amendment 1
Add, after the second NOTE introduced in Amendment 1, the following new text:
Insulation shall be adequate between input and output terminals bonded together, and all
exposed metal parts and the control terminals, were relevant. Controlgear, having insulation
cover or envelope is wrapped with metal foil.
Delete, in Subclause 14.6 of Amendment 1, in the first sentence and under item a), the words
“at least”.
−0
Add, in Subclause 14.6, in the first sentence and under item a), after 160 A % the word
+10
“r.m.s.”.

15 Construction
Add, after Subclause 15.2, the following new subclause:
15.3 Plugs and socket-outlets used in SELV or ELV circuits
For controlgears providing SELV or ELV socket-outlets, the output circuit shall be such that
there is no dangerous compatibility between such a socket-outlet and a plug intended for
direct connection to a socket-outlet which could be used for the input circuit in relation to
installation rules, voltages and frequencies.
Plugs and socket-outlets for SELV system shall comply with the requirements of IEC 60906-3
and IEC 60884-2-4. However, plugs and socket-outlets for SELV systems with both a rated
current ~ 3 A and a maximum voltage of 25 V a.c. or 60 V d.c. with a power not exceeding
72 W are allowed to comply only with the following requirements:
– plugs shall not be able to enter socket-outlets of other standardised systems;
– socket-outlets shall not admit plugs of other standardised voltage systems;
– socket-outlets shall not have a protective earth contact.
As IEC 60906-3 covers only 6 V, 12 V, 24 V and 48 V output voltage, controlgear with
intermediate output voltages shall be able to withstand the nearest upper voltage.
16 Creepage distances and clearances
Replace the first paragraph by the following:
Creepage distances and clearances shall be not less than the values given in Tables 3 and 4,
as appropriate, unless otherwise specified in C
...