IEC 60947-3:2020/COR1:2021
(Corrigendum)Corrigendum 1 - Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units
Corrigendum 1 - Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units
Corrigendum 1 - Appareillage à basse tension - Partie 3: Interrupteurs, sectionneurs, interrupteurs-sectionneurs et combinés-fusibles
General Information
Relations
Standards Content (Sample)
IEC 60947-3/COR1:2021 – 1 –
IEC 2021
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 60947-3 IEC 60947-3
Edition 4.0 2020-04 Édition 4.0 2020-04
Low-voltage switchgear and controlgear – Appareillage à basse tension –
Part 3: Switches, disconnectors, switch- Partie 3: Interrupteurs, sectionneurs,
disconnectors and fuse-combination interrupteurs-sectionneurs et combinésfusibles
units
CO RRI G E NDUM 1
9.3.7.2.3 Test circuit calibration 9.3.7.2.3 Etalonn
...
This May Also Interest You
IEC 60947-5-1:2024 applies to control circuit devices and switching elements intended for controlling, signalling, interlocking, etc., of switchgear and controlgear.
It applies to control circuit devices having a rated voltage not exceeding 1 000 V AC (at a frequency not exceeding 1 000 Hz) or 600 V DC.
This fifth edition cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) update of the scope structure and exclusions;
b) requirements for control circuits;
c) update of the normal service conditions (e.g. shock and vibration);
d) update of information and marking requirements including environmental information requirements referencing IEC TS 63058:2021;
e) update of the constructional requirements and the corresponding tests considering safety aspects (e.g. artificial optical radiation, security aspects, limited energy source, stored charge energy circuit);
f) update of the EMC requirements according to the generic documents;
g) new requirements for reed contact magnetic switches in Annex D;
h) requirements for class II circuit devices achieved by double or reinforced insulation in Annex F;
i) update of pull-out tests in Annex G;
j) information requirements for audible signalling device in Annex J;
k) insertion of new Annex O.
- Standard263 pagesEnglish and French languagesale 15% off
IEC 62626-1:2023 is available as IEC 62626-1:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62626-1:2023 applies to enclosed switches-disconnectors with rated voltages up to 1 000 V AC for repair and maintenance work or cleaning work in load circuits. Devices within the scope of this document are switch-disconnectors in accordance with IEC 60947-3 with specific additional requirements. Enclosed switch-disconnectors in this document are suitable for isolation in accordance with the IEC 60947 series and are not equipped with means for remote control or automatic switching to avoid unexpected or accidental start. These devices are not used for operational switching, for example quick start and stop, jogging. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) update of this document based on IEC 60947-1:2020.
- Standard33 pagesEnglish languagesale 15% off
- Standard21 pagesEnglish and French languagesale 15% off
- Standard2 pagesEnglish and French languagesale 15% off
- Standard2 pagesEnglish and French languagesale 15% off
IEC 60947-9-2:2021 covers internal arc-fault control devices, hereinafter referred to as IACD, which are intended to:
– detect internal arc-faults in low-voltage switchgear and controlgear assemblies, by processing (at a minimum) the optical effect of an internal arc-fault, and
– operate mitigation device (either external or combined) in order to minimize the effects of the internal arc-fault.
- Standard175 pagesEnglish and French languagesale 15% off
IEC 60947-6-1:2021 applies to transfer switching equipment (TSE), to be used in power systems for ensuring the continuity of the supply and allowing the energy management of the installation, by transferring a load between power supply sources, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC.
This third edition cancels and replaces the second edition published in 2005, and its Amendment 1:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
– clarification of scope and object;
– clarification of terms and definitions;
– removal of unnecessary definitions;
– modification of characteristics;
– modification of utilization categories definitions;
– introduction of new markings requirements;
– addition of new requirements for clearances and creepage distances;
– addition of new requirements and tests for mechanical and electrical interlocks;
– clarification of transfer sequences;
– modification of requirements for rated short-time withstand currents;
– modification of new requirements for electromagnetic compatibility;
– clarification of performance requirements for CB type TSE, in alignment with requirements stated in IEC 60947-2;
– addition of new test sequence V: Critical load current performance of equipment with DC ratings.
- Standard121 pagesEnglish and French languagesale 15% off
IEC 60947-6-2:2020 This document applies to control and protective switching devices (or equipment) (CPS), the main contacts of which are intended to be connected to circuits of rated voltage not exceeding 1 000 V AC or 1 500 V DC.
It covers control and protective switching device (CPS):
- which provides protective and control functions for circuits and motors;
- where its control function is operated exclusively otherwise than by hand;
- which provides continuity of service after over-current conditions; and
- which can have additional functions, such as isolation or communication.
This third edition cancels and replaces the second edition published in 2002 and its Amendment 1:2007. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- editorial changes according to ISO/IEC directives Part 2,
- alignments with IEC 60947-1:2020:
- markings ("s", "sol", "r" or "f");
- constructional requirements including material requirements;
- requirements for screwless terminals;
- measurement method of the pole impedance;
- EMC requirement and testing;
- procedure to determine data for electromechanical CPS’s used in functional safety applications;
harmonisation with IEC 60947-2:2016:
- operation tests of under-voltage relays and shunt releases;
- CPS for IT systems (Annex G);
- coordination with other short-circuit protective devices;
alignments with IEC 60947-4-1:2018:
- test at the rated conditional short-circuit current Iq of protected switching devices;
- short-circuit tests harmonisation with North America;
- reliability data for functional safety applications (new Annex K);
- safety aspects related to electronic circuits and protective impedance (new Annex N);
- introduction of provisions covering the impact of higher locked rotor current to achieve high efficiency class;
- mention of dedicated wiring accessories;
- definitions and measurement method of the power consumption of the control circuit during holding and pick-up operations;
- load monitoring indicators (new Annex M).
The contents of the corrigenda of December 2021 and June 2023 have been included in this copy.
- Standard225 pagesEnglish and French languagesale 15% off
IEC 60947-3:2020 applies to switches, disconnectors, switch-disconnectors and fuse-combination units and their dedicated accessories to be used in distribution circuits and motor circuits of which the rated voltage does not exceed 1 000 V AC or 1 500 V DC.
This fourth edition cancels and replaces the third edition published in 2008, Amendment 1:2012 and Amendment 2:2015. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
addition of critical load current tests for DC switches (see 9.3.9);
addition of requirements for a conditional short-circuit rating for disconnectors, switches, and switch-disconnectors protected by circuit-breakers (see 9.3.7.2);
addition of new categories for high-efficiency motors switching (see Annex A);
addition of new Annex E for connection to aluminium conductors;
addition of new Annex F for power losses measurement. The contents of the corrigendum of October 2021 have been included in this copy.
- Standard190 pagesEnglish and French languagesale 15% off
- Standard1 pageEnglish and French languagesale 15% off
IEC 60947-5-2:2019 applies to inductive and capacitive proximity switches that sense the presence of metallic and/or non-metallic objects, ultrasonic proximity switches that sense the presence of sound reflecting objects, photoelectric proximity switches that sense the presence of objects and non-mechanical magnetic proximity switches that sense the presence of objects with a magnetic field.
This fourth edition cancels and replaces the third edition published in 2007 and Amendment 1:2012. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
update of the scope;
adaptation and update of the construction requirements according to IEC Guide 116 (e.g. material requirements, artificial optical radiation, instruction requirements, hot surface, unattended operation, foreseeable misuse…);
modification of the specifications concerning the sensing range and operating distance;
new definitions for photoelectric proximity switch type D with background suppression;
integration of the requirements and test procedures of photoelectric proximity switch type D with background suppression;
update of EMC requirements in Table 9 and Table 10;
integration of environmental information requirements and environmental condition by referencing Annexes O, W and Q of IEC 60947-1:2007, IEC 60947-1:2007/AMD1:2010 and IEC 60947-1:2007/AMD2:2014;
modification of impulse withstand voltage test (5.3.1.3, 9.3.3.4.5);
modification of the references in the (normative) standard body to the (informative) Annex A;
major update of Annex A (definitions update, new dimensions and shapes);
update of C.9.1.1;
update of Annex D in order to consider new connector types and normative references;
update of Annex F (additional symbols for photoelectric proximity switches).