IEC 60335-2-95:2002/AMD1:2004
(Amendment)Amendment 1 - Household and similar electrical appliances - Safety - Part 2-95: Particular requirements for drives for vertically moving garage doors for residential use
Amendment 1 - Household and similar electrical appliances - Safety - Part 2-95: Particular requirements for drives for vertically moving garage doors for residential use
Amendement 1 - Appareils électrodomestiques et analogues - Sécurité - Partie 2-95: Règles particulières pour les motorisations de portes de garage à ouverture verticale, pour usage résidentiel
General Information
Relations
Standards Content (Sample)
INTERNATIONAL IEC
STANDARD 60335-2-95
AMENDMENT 1
2004-11
Amendment 1
Household and similar electrical appliances –
Safety –
Part 2-95:
Particular requirements for drives for vertically
moving garage doors for residential use
IEC 2004 Droits de reproduction réservés Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
Commission Electrotechnique Internationale M
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue
– 2 – 60335-2-95 Amend. 1 IEC:2004(E)
FOREWORD
This amendment has been prepared by IEC technical committee 61: Safety of household and
similar electrical appliances.
The text of this amendment is based on the following documents:
FDIS Report on voting
61/2745/FDIS 61/2790/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
_____________
INTRODUCTION
Replace the second sentence of the second paragraph by the following:
It also covers abnormal situations that can be expected in practice and takes into account the
way in which electromagnetic phenomena can affect the safe operation of appliances.
1 Scope
Add the following note:
NOTE 106 This standard also covers automatic drives.
3 Definitions
3.101 Delete the word “inherent” in the note.
3.102 Replace the existing text by the following:
entrapment protection system
part of the drive that protects against trapping which could result in the human body being
squeezed or crushed by the door
NOTE 1 Trapping in the garage is covered by the manual release of 20.109.
NOTE 2 An entrapment protection system may be incorporated in the motor assembly or may be installed
separately. It may consist of one or more devices, such as pressure sensitive edges, passive infrared, active light
sensing devices or a biased-off switch.
60335-2-95 Amend. 1 IEC:2004(E) – 3 –
3.103 Replace the existing text by the following:
automatic drive
drive that operates the door in at least one direction without intentional activation by the user
5 General conditions for the tests
5.2 Add the following sentence after the first sentence of the addition:
An artificial load may be used to simulate the door for some of the tests.
Add the following subclause:
5.5 Addition:
Wicket doors are kept closed during the tests.
6 Classification
6.2 Replace the text of the addition by the following:
Drives intended to be exposed to outdoor conditions shall be at least IPX4.
6.101 Delete this subclause.
7 Marking and instructions
7.1 Replace the text of the addition by the following:
Modification:
Drives shall be marked with the rated power input.
Addition:
Drives supplied without a door shall be marked with the rated load in N or in Nm.
7.12 Replace the second dashed item of the addition by the following:
– watch the moving door and keep people away until the door is completely opened or
closed (not necessary for automatic drives);
Replace the last dashed item of the addition by the following two dashed items:
– information concerning the adjustment of the door and drive (when applicable);
– disconnect the supply when cleaning or carrying out other maintenance.
Add the following paragraph:
Instructions for automatic drives shall state the substance of the following:
WARNING: Automatic door – The door may operate unexpectedly, therefore do not allow
anything to stay in the path of the door.
– 4 – 60335-2-95 Amend. 1 IEC:2004(E)
7.12.1 Replace the second paragraph of the addition by the following two paragraphs:
The installation instructions shall include details for the installation of the drive and its
associated components.
For drives supplied without a door, the installation instructions shall indicate the type, size
and mass of doors for which the drive is intended to be used.
Add the following dashed items:
– necessary information for the safe handling of a drive weighing more than 20 kg. This
information shall describe how to use the handling means, such as hooks and ropes;
– the drive must not be used with a door incorporating a wicket door (unless the drive
cannot be operated with the wicket door open);
– after installation, ensure that parts of the door do not extend over public footpaths or
roads.
7.101 Replace the existing text by the following:
Drives shall be supplied with a label suitable for permanent fixing. For automatic drives, the
label shall state the substance of the following:
WARNING: Automatic drive – Keep away from the area of the door since it may operate
unexpectedly.
For other drives, the label shall include a warning sign having a height of at least 60 mm. The
label shall also include the substance of the following:
WARNING: Keep children away when the door is moving.
NOTE An example of a suitable warning sign is shown in Figure 102.
Compliance is checked by inspection and measurement.
7.102 Replace the existing text by the following:
Drives that use contact sensing as an entrapment protection system shall be supplied with
a label that states the substance of the following:
WARNING: Risk of entrapment – Regularly check and, if necessary, adjust to ensure that,
when the door contacts a 40 mm high object placed on the floor, the door
reverses or the object can be freed.
Compliance is checked by inspection.
Add the following new subclause:
7.104 If the drive is intended to be installed by the user, the packaging shall indicate the
type of door, including its size and mass, that the drive is intended to operate and, if
applicable, that the drive
– is intended to be installed at least 2,5 m above the floor or other access level;
– can be used with doors having openings greater than 50 mm in diameter;
– is intended for automatic operation.
Compliance is checked by inspection.
60335-2-95 Amend. 1 IEC:2004(E) – 5 –
11 Heating
11.7 Replace the text of the replacement by the following:
Drives for continuous operation are operated for consecutive cycles until steady conditions
are established.
Automatic drives are operated without rest periods for 3 cycles or 4 min, whichever is
longer.
NOTE A cycle is based on the maximum size of door the drive is intended to operate.
Other drives are operated as follows:
– drives supplied without a door are operated without rest periods for a minimum of 2 min
unless the rated operating time is longer;
– drives supplied with a door are operated without rest periods for 3 cycles.
15 Moisture resistance
Replace the existing text by the following:
This clause of Part 1 is applicable except as follows.
15.1.1 Addition:
Parts of drives intended to be exposed to outdoor conditions are subjected to the tests
specified for IPX4 appliances.
15.1.2 Addition:
IPX4 tubular drives are installed in a tube that is open at both ends and has the largest
diameter specified in the instructions. The tube has a length twice that of the motor and is
mounted on a support as in normal use. The support is rotated at a speed of 1 r/min.
19 Abnormal operation
Add the following subclause:
19.1 Addition:
Drives are also subjected to the test of 19.101.
19.10 Replace the existing text by the following:
Addition:
For drives having a manual release, the test is repeated with the drive released.
The test is carried out for one cycle of operation if this is longer than 1 min.
– 6 – 60335-2-95 Amend. 1 IEC:2004(E)
19.13 Replace the text of the addition by the following:
For each fault condition in 19.11.2, if the appliance is still operating, it shall comply with
20.102 to 20.106.
Add the following subclause:
19.101 Drives, other than those for continuous operation, are supplied at rated voltage and
operated continuously under normal operation.
20 Stability and mechanical hazards
20.2 Replace the text of the addition by the following:
NOTE 101 Moving parts of drives intended to be installed at a height of at least 2,5 m above the ground are
considered to be positioned so that adequate protection is provided.
NOTE 102 Chains moving at less than 0,2 m/s are not considered to be dangerous moving parts.
20.101 Replace the requirement by the following:
Drives shall prevent doors from closing unexpectedly during normal use.
Add the following sentence to the second paragraph of the test specification.
Automatic operation of automatic drives is rendered inoperative.
Replace the existing text of subclauses 20.102 to 20.108 by the following:
20.102 Drives controlled by a biased-off switch shall stop when the actuating member of
the switch is released.
Compliance is checked by the following test.
The drive is installed with a door and supplied at the most unfavourable voltage between 0,94
times and 1,06 times the rated voltage. It is operated to close the door. When the actuating
member of the switch is released,
– if the closing force exerted by the door does not exceeds 150 N, as measured in 20.104.1,
the bottom edge of the door shall stop;
– if the closing force exerted by the door exceeds 150 N, as measured in 20.104.1, the
bottom edge of the door shall stop before it has travelled more than 50 mm vertically;
The test is repeated during the opening movement of the door.
20.103 Drives incorporating an entrapment protection system with sensing devices which
prevent the door coming into contact with an obstacle shall not cause injury resulting from a
moving door.
Compliance is checked by the following test.
The drive is installed with a door, the force exerted by the drive is set at the maximum value
according to the instructions and the drive is supplied at the most unfavourable voltage
between 0,94 times and 1,06 times the rated voltage.
60335-2-95 Amend. 1 IEC:2004(E) – 7 –
An obstacle having dimensions of approximately 80 mm x 300 mm and a height of 100 mm is
placed on the ground and centrally along its 300 mm length across the door opening. The
drive is operated to close the door from heights of 100 mm, 1 000 mm and the fully open
position of the door. The door shall not move or only move in the opening direction.
NOTE The obstacle is normally made of rough wood and painted white but other materials and colours may be
used to simulate the most unfavourable conditions.
The obstacle is positioned centrally in the door opening and is then raised in increments up to
300 mm from the height of the door, but not higher than 2,5 m. At each increment, the drive is
operated to close the door. The door shall stop within 50 mm or reverse its movement without
contacting the obstacle.
A cylindrical obstacle, having a diameter of 50 mm and a length of 850 mm, is suspended
centrally in the door opening. It is suspended vertically with the upper end at a height of
900 mm above the ground.
The drive is operated to close the door and the cylinder is swung across the door opening
from an angle of 45°. The entrapment protection system shall cause the door to reverse i
...
IEC 60335-2-95
Edition 2.0 2004-11
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
AMENDMENT 1
AMENDEMENT 1
Household and similar electrical appliances – Safety –
Part 2-95: Particular requirements for drives for vertically moving garage doors
for residential use
Appareils électrodomestiques et analogues – Sécurité –
Partie 2-95: Règles particulières pour les motorisations de portes de garage à
ouverture verticale, pour usage résidentiel
IEC 60335-2-95:2002/A1:2004
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
ƒ Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
ƒ Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
ƒ Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
ƒ Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 60335-2-95
Edition 2.0 2004-11
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
AMENDMENT 1
AMENDEMENT 1
Household and similar electrical appliances – Safety –
Part 2-95: Particular requirements for drives for vertically moving garage doors
for residential use
Appareils électrodomestiques et analogues – Sécurité –
Partie 2-95: Règles particulières pour les motorisations de portes de garage à
ouverture verticale, pour usage résidentiel
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
N
CODE PRIX
ICS 13.120; 29.120.01; 91.090 ISBN 2-8318-8044-0
– 2 – 60335-2-95 Amend 1 © CEI:2004
AVANT-PROPOS
Cet amendement a été établi par le comité d’études 61: Sécurité des appareils
électrodomestiques et analogues.
Cette version bilingue, publiée en 2005-07, correspond à la version anglaise.
Le texte anglais de cet amendement est issu des documents 61/2745/FDIS et 61/2790/RVD.
Le rapport de vote 61/2790/RVD donne toute information sur le vote ayant abouti à
l'approbation de cet amendement.
La version française de cet amendement n’a pas été soumise au vote.
Le comité a décidé que le contenu de cet amendement et de la publication de base ne sera
pas modifié avant la date de maintenance indiquée sur le site web de la CEI sous
"http://webstore.iec.ch" dans les données relatives à la publication recherchée. A cette date,
la publication sera
• reconduite,
• supprimée,
• remplacée par une édition révisée, ou
• amendée.
_____________
INTRODUCTION
Remplacer la deuxième phrase du deuxième alinéa par ce qui suit:
Elle couvre également les situations anormales auxquelles on peut s'attendre dans la pratique
et prend en considération les phénomènes électromagnétiques qui peuvent affecter le
fonctionnement en toute sécurité des appareils.
1 Domaine d’application
Ajouter la note suivante:
NOTE 106 La présente norme couvre également les motorisations automatiques.
3 Définitions
3.101 Supprimer le mot «internes» dans la note.
3.102 Remplacer le texte existant par ce qui suit.
système de protection contre l'écrasement
partie de la motorisation qui assure la protection contre un piégeage pouvant entraîner pour
le corps humain d’être écrasé ou coincé par la porte
NOTE 1 Le piégeage dans le garage est couvert par le dispositif de dépannage manuel de 20.109.
NOTE 2 Un système de protection contre l'écrasement peut être incorporé dans l'assemblage du moteur ou
être installé séparément. Il peut être constitué d'un ou de plusieurs dispositifs, tels que des bords sensibles à la
pression, des dispositifs sensibles aux infrarouges, des dispositifs sensibles à la lumière active ou un interrupteur
sans verrouillage.
60335-2-95 Amend. 1 © IEC:2004 – 3 –
FOREWORD
This amendment has been prepared by IEC technical committee 61: Safety of household and
similar electrical appliances.
This bilingual version, published in 2005-07, corresponds to the English version.
The text of this amendment is based on the following documents:
FDIS Report on voting
61/2745/FDIS 61/2790/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The French version of this amendment has not been voted upon.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
_____________
INTRODUCTION
Replace the second sentence of the second paragraph by the following:
It also covers abnormal situations that can be expected in practice and takes into account the
way in which electromagnetic phenomena can affect the safe operation of appliances.
1 Scope
Add the following note:
NOTE 106 This standard also covers automatic drives.
3 Definitions
3.101 Delete the word “inherent” in the note.
3.102 Replace the existing text by the following:
entrapment protection system
part of the drive that protects against trapping which could result in the human body being
squeezed or crushed by the door
NOTE 1 Trapping in the garage is covered by the manual release of 20.109.
NOTE 2 An entrapment protection system may be incorporated in the motor assembly or may be installed
separately. It may consist of one or more devices, such as pressure sensitive edges, passive infrared, active light
sensing devices or a biased-off switch.
– 4 – 60335-2-95 Amend 1 © CEI:2004
3.103 Remplacer le texte existant par ce qui suit:
motorisation automatique
motorisation qui fait fonctionner la porte dans au moins une direction sans action
intentionnelle de l’utilisateur
5 Conditions générales d’essais
5.2 Ajouter la phrase suivante après la première phrase de l’addition:
Pour certains essais, une charge artificielle peut être utilisée pour simuler la porte.
Ajouter le paragraphe suivant:
5.5 Addition:
Les portillons sont fermés pendant les essais.
6 Classification
6.2 Remplacer le texte de l’addition par ce qui suit.
Les motorisations destinées à être exposées aux conditions extérieures doivent être au
moins IPX4.
6.101 Supprimer ce paragraphe.
7 Marquage et indications
7.1 Remplacer le texte de l’addition par ce qui suit.
Modification:
Les motorisations doivent porter le marquage de la puissance assignée.
Addition:
Les motorisations livrées sans porte doivent porter le marquage de la charge assignée
en N ou en Nm.
7.12 Remplacer le deuxième tiret de l’addition par le suivant:
– surveiller la porte en mouvement et maintenir les personnes éloignées jusqu'à ce que la
porte soit complètement ouverte ou fermée (non nécessaire pour les motorisations
automatiques);
Remplacer le dernier tiret de l’addition par les deux tirets suivants:
– des informations concernant le réglage de la porte et de la motorisation (s’il y a lieu);
– déconnecter l’alimentation lors du nettoyage ou de la réalisation d’un autre entretien.
60335-2-95 Amend. 1 © IEC:2004 – 5 –
3.103 Replace the existing text by the following:
automatic drive
drive that operates the door in at least one direction without intentional activation by the user
5 General conditions for the tests
5.2 Add the following sentence after the first sentence of the addition:
An artificial load may be used to simulate the door for some of the tests.
Add the following subclause:
5.5 Addition:
Wicket doors are kept closed during the tests.
6 Classification
6.2 Replace the text of the addition by the following:
Drives intended to be exposed to outdoor conditions shall be at least IPX4.
6.101 Delete this subclause.
7 Marking and instructions
7.1 Replace the text of the addition by the following:
Modification:
Drives shall be marked with the rated power input.
Addition:
Drives supplied without a door shall be marked with the rated load in N or in Nm.
7.12 Replace the second dashed item of the addition by the following:
– watch the moving door and keep people away until the door is completely opened or
closed (not necessary for automatic drives);
Replace the last dashed item of the addition by the following two dashed items:
– information concerning the adjustment of the door and drive (when applicable);
– disconnect the supply when cleaning or carrying out other maintenance.
– 6 – 60335-2-95 Amend 1 © CEI:2004
Ajouter le paragraphe suivant:
Les instructions des motorisations automatiques doivent comporter, en substance, la mise
en garde suivante:
MISE EN GARDE: Porte automatique – La porte peut fonctionner à l’improviste, par
conséquent ne rien laisser dans la trajectoire de la porte.
7.12.1 Remplacer le deuxième alinéa de l’addition par les deux alinéas suivants:
Les instructions d’installation doivent comporter des précisions concernant l’installation de la
motorisation et de ses composants associés.
Pour les motorisations livrées sans porte, les instructions d’installation doivent indiquer le
type, les dimensions et la masse des portes pour lesquelles la motorisation est destinée à
être utilisée.
Ajouter les tirets suivants:
– les informations nécessaires pour la manipulation en toute sécurité d’une motorisation
pesant plus de 20 kg. Ces informations doivent décrire la façon d’utiliser les dispositifs de
manipulation, tels que crochets et câbles;
– ne pas utiliser la motorisation avec une porte comprenant un portillon (à moins que la
motorisation ne puisse pas être mise en fonctionnement avec le portillon ouvert);
– après installation, s’assurer que des parties de la porte n’empiètent pas sur les trottoirs ou
sur la voie publique.
7.101 Remplacer le texte existant par ce qui suit:
Les motorisations doivent être fournies avec une étiquette pouvant être fixée à demeure.
Pour les motorisations automatiques, l’étiquette doit comporter, en substance, la mise en
garde suivante:
MISE EN GARDE: Motorisation automatique – Rester éloigné de la porte, celle-ci
pouvant fonctionner à l’improviste.
Pour les autres motorisations, l’étiquette doit comporter un symbole de mise en garde de
hauteur minimale 60 mm. L’étiquette doit également comporter, en substance, la mise en
garde suivante:
MISE EN GARDE: Eloignez les enfants lorsque la porte est en mouvement.
NOTE Un exemple de symbole de mise en garde approprié est représenté à la Figure 102.
La vérification est effectuée par examen et par des mesures.
7.102 Remplacer le texte existant par ce qui suit.
Les motorisations qui utilisent un dispositif sensible au contact comme système de
protection contre l'écrasement doivent être livrées avec une étiquette comportant, en
substance, la mise en garde suivante:
MISE EN GARDE: Risque d’écrasement – Vérifier régulièrement, et régler si nécessaire,
pour s’assurer que, lorsque la porte rencontre un objet de 40 mm de
haut placé sur le sol, la porte inverse son mouvement ou l’objet peut
être écarté librement.
La vérification est effectuée par examen.
60335-2-95 Amend. 1 © IEC:2004 – 7 –
Add the following paragraph:
Instructions for automatic drives shall state the substance of the following:
WARNING: Automatic door – The door may operate unexpectedly, therefore do not allow
anything to stay in the path of the door.
7.12.1 Replace the second paragraph of the addition by the following two paragraphs:
The installation instructions shall include details for the installation of the drive and its
associated components.
For drives supplied without a door, the installation instructions shall indicate the type, size
and mass of doors for which the drive is intended to be used.
Add the following dashed items:
– necessary information for the safe handling of a drive weighing more than 20 kg. This
information shall describe how to use the handling means, such as hooks and ropes;
– the drive must not be used with a door incorporating a wicket door (unless the drive
cannot be operated with the wicket door open);
– after installation, ensure that parts of the door do not extend over public footpaths or
roads.
7.101 Replace the existing text by the following:
Drives shall be supplied with a label suitable for permanent fixing. For automatic drives, the
label shall state the substance of the following:
WARNING: Automatic drive – Keep away from the area of the door since it may operate
unexpectedly.
For other drives, the label shall include a warning sign having a height of at least 60 mm. The
label shall also include the substance of the following:
WARNING: Keep children away when the door is moving.
NOTE An example of a suitable warning sign is shown in Figure 102.
Compliance is checked by inspection and measurement.
7.102 Replace the existing text by the following:
Drives that use contact sensing as an entrapment protection system shall be supplied with
a label that states the substance of the following:
WARNING: Risk of entrapment – Regularly check and, if necessary, adjust to ensure that,
when the door contacts a 40 mm high object placed on the floor, the door
reverses or the object can be freed.
Compliance is checked by inspection.
– 8 – 60335-2-95 Amend 1 © CEI:2004
Ajouter le nouveau paragraphe suivant:
7.104 Pour les motorisations destinées à être installées par l’utilisateur, l’emballage doit
indiquer le type de porte, dimensions et masse comprises, que la motorisation peut entraîner
et indiquer, le cas échéant, que la motorisation
– est prévue pour être installée à au moins 2,5 m au-dessus du sol ou d’un autre niveau
d’accès,
– peut être utilisée avec des portes ayant des ouvertures de diamètre supérieur à 50 mm,
– est prévue pour un fonctionnement automatique.
La vérification est effectuée par examen.
11 Echauffements
11.7 Remplacer le texte du remplacement par ce qui suit:
Les motorisations pour fonctionnement continu sont soumises à des cycles de
fonctionnement consécutifs jusqu'à établissement des conditions de régime.
Les motorisations automatiques sont mises en fonctionnement sans période de repos
pendant 3 cycles ou 4 min, suivant la durée la plus longue.
NOTE Un cycle est basé sur la dimension maximale de porte que la motorisation peut entraîner.
Les autres motorisations sont mises en fonctionnement de la façon suivante:
– les motorisations livrées sans porte sont mises en fonctionnement sans période de repos
pendant au moins 2 min, à moins que la durée de fonctionnement assignée ne soit plus
longue;
– les motorisations livrées avec une porte sont mises en fonctionnement sans période de
repos pendant 3 cycles.
15 Résistance à l’humidité
Remplacer le texte existant par ce qui suit:
L’article de la Partie 1 est applicable avec les exceptions suivantes.
15.1.1 Addition:
Les parties des motorisations destinées à être exposées aux conditions extérieures sont
soumises aux essais spécifiés pour les appareils IPX4.
15.1.2 Addition:
Les motorisations tubulaires IPX4 sont installées à l'intérieur d'un tube ouvert aux deux
extrémités et ayant le plus grand diamètre spécifié dans les instructions. Le tube a une
longueur double de celle du moteur et est monté sur un support comme en usage normal. Le
support tourne à une vitesse de 1 r/min.
60335-2-95 Amend. 1 © IEC:2004 – 9 –
Add the following new subclause:
7.104 If the drive is intended to be installed by the user, the packaging shall indicate the
type of door, including its size and mass, that the drive is intended to operate and, if
applicable, that the drive
– is intended to be installed at least 2,5 m above the floor or other access level;
– can be used with doors having openings greater than 50 mm in diameter;
– is intended for automatic operation.
Compliance is checked by inspection.
11 Heating
11.7 Replace the text of the replacement by the following:
Drives for continuous operation are operated for consecutive cycles until steady conditions
are established.
Automatic drives are operated without rest periods for 3 cycles or 4 min, whichever is
longer.
NOTE A cycle is based on the maximum size of door the drive is intended to operate.
Other drives are operated as follows:
– drives supplied without a door are operated without rest periods for a minimum of 2 min
unless the rated operating time is longer;
– drives supplied with a door are operated without rest periods for 3 cycles.
15 Moisture resistance
Replace the existing text by the following:
This clause of Part 1 is applicable except as follows.
15.1.1 Addition:
Parts of drives intended to be exposed to outdoor conditions are subjected to the tests
specified for IPX4 appliances.
15.1.2 Addition:
IPX4 tubular drives are installed in a tube that is open at both ends and has the largest
diameter specified in the instructions. The tube has a length twice that of the motor and is
mounted on a support as in normal use. The support is rotated at a speed of 1 r/min.
– 10 – 60335-2-95 Amend 1 © CEI:2004
19 Fonctionnement anormal
Ajouter le paragraphe suivant:
19.1 Addition:
La vérification est également effectuée par l’essai de 19.101.
19.10 Remplacer le texte existant par ce qui suit.
Addition:
Pour les motorisations équipées d’un dispositif de dépannage manuel, l’essai est répété
avec la motorisation relâchée.
L’essai est effectué sur un cycle de fonctionnement si la durée du cycle est supérieure à 1 min.
19.13 Remplacer le texte de l’addition par ce qui suit:
Pour chaque condition de défaut de 19.11.2, si l’appareil est toujours en état de fonctionner,
il doit satisfaire aux paragraphes 20.102 à 20.106.
Ajouter le paragraphe suivant:
19.101 Les motorisations, autres que celles pour fonctionnement continu, sont alimentées
sous la tension assignée et mises en fonctionnement de façon continue dans les conditions
de fonctionnement normal.
20 Stabilité et dangers mécaniques
20.2 Remplacer le texte de l’addition par ce qui suit:
NOTE 101 Les parties mobiles des motorisations destinées à être installées à une hauteur minimale de 2,5 m
au-dessus du sol sont considérées comme étant placées de manière à assurer une protection suffisante.
NOTE 102 Les chaînes dont la vitesse de déplacement est inférieure à 0,2 m/s ne sont pas considérées comme
étant des parties mobiles dangereuses.
20.101 Remplacer l’exigence par ce qui suit:
Les motorisations doivent empêcher une fermeture inopinée des portes en usage normal.
Ajouter la phrase suivante au deuxième alinéa de la modalité d’essai:
Le fonctionnement automatique des motorisations automatiques est rendu inopérant.
Remplacer le texte existant des paragraphes 20.102 à 20.108 par ce qui suit.
20.102 Les motorisations commandées par un interrupteur sans verrouillage doivent
s’arrêter lorsque l’organe de manœuvre de l’interrupteur est relâché.
La vérification est effectuée par l’essai suivant.
60335-2-95 Amend. 1 © IEC:2004 – 11 –
19 Abnormal operation
Add the following subclause:
19.1 Addition:
Drives are also subjected to the test of 19.101.
19.10 Replace the existing text by the following:
Addition:
For drives having a manual release, the test is repeated with the drive released.
The test is carried out for one cycle of operation if this is longer than 1 min.
19.13 Replace the text of the addition by the following:
For each fault condition in 19.11.2, if the appliance is still operating, it shall comply with
20.102 to 20.106.
Add the following subclause:
19.101 Drives, other than those for continuous operation, are supplied at rated voltage and
operated continuously under normal operation.
20 Stability and mechanical hazards
20.2 Replace the text of the addition by the following:
NOTE 101 Moving parts of drives intended to be installed at a height of at least 2,5 m above the ground are
considered to be positioned so that adequate protection is provided.
NOTE 102 Chains moving at less than 0,2 m/s are not considered to be dangerous moving parts.
20.101 Replace the requirement by the following:
Drives shall prevent doors from closing unexpectedly during normal use.
Add the following sentence to the second paragraph of the test specification.
Automatic operation of automatic drives is rendered inoperative.
Replace the existing text of subclauses 20.102 to 20.108 by the following:
20.102 Drives controlled by a biased-off switch shall stop when the actuating member of
the switch is released.
Compliance is checked by the following test.
– 12 – 60335-2-95 Amend 1 © CEI:2004
La motorisation est installée avec une porte et alimentée sous la tension la plus défavorable
comprise entre 0,94 fois et 1,06 fois la tension assignée. Elle est mise en fonctionnement
pour fermer la porte. Lorsque l’organe de manœuvre de l’interrupteur est relâché,
– le bord inférieur de la porte doit s’arrêter si la force de fermeture exercée par la porte,
mesurée conformément à 20.104.1, ne dépasse pas 150 N;
– le bord inférieur de la porte doit s’arrêter avant d’avoir parcouru verticalement plus de
50 mm si la force de fermeture exercée par la porte, mesurée conformément à 20.104.1,
dépasse 150 N.
L’essai est répété pendant le mouvement d’ouverture de la porte.
20.103 Les motorisations comportant un système de protection contre l’écrasement à
dispositifs sensibles qui empêche le contact de la porte avec un obstacle ne doivent pas
provoquer de blessures dues au mouvement de la porte.
La vérification est effectuée par l’essai suivant.
La motorisation est installée avec une porte, la force exercée par la motorisation est réglée
au maximum conformément aux instructions et la motorisation est alimentée sous la tension
la plus défavorable comprise entre 0,94 fois et 1,06 fois la tension assignée.
Un obstacle de dimensions approximatives 80 mm x 300 mm et d’une hauteur de 100 mm est
placé sur le sol et centré sur sa dimension de 300 mm dans l’ouverture de la porte. La
motorisation est mise en fonctionnement pour fermer la porte à partir de 100 mm et de
1 000 mm de hauteur, et à partir de la position complètement ouverte de la porte. La porte ne
doit pas bouger ou ne doit bouger que dans le sens de l’ouverture.
NOTE L’obstacle est normalement réalisé en bois brut peint en blanc, mais d’autres matériaux et couleurs
peuvent être utilisés pour simuler les conditions les plus défavorables.
L’obstacle est centré dans l’ouverture de la porte puis il est levé, par paliers, jusqu’à 300 mm
du sommet de la porte, sans toutefois dépasser une hauteur de 2,5 m. A chaque palier, la
motorisation est mise en fonctionnement pour fermer la porte. La porte doit s’arrêter dans
les limites de 50 mm ou inverser son mouvement sans toucher l’obstacle.
Un obstacle cylindrique de diamètre 50 mm et de longueur 850 mm est suspendu au centre
de l’ouverture de la porte. Il est suspendu verticalement, l’extrémité supérieure étant située à
900 mm au-dessus du sol.
La motorisation est mise en fonctionnement pour fermer la porte et le cylindre est mis en
oscillation dans l’ouverture de la porte à partir d’un angle de 45°. Le système de protection
contre l’écrasement doit provoquer l’inversion du mouvement de la porte.
L’essai est répété à partir de la position complètement ouverte, l’obstacle étant
successivement positionné à 100 mm de chacune des extrémités de l’ouverture de la porte.
Pendant les essais, tout interrupteur sans verrouill
...