IEC 60384-17:2019/COR1:2020
(Corrigendum)Corrigendum 1 - Fixed capacitors for use in electronic equipment - Part 17: Sectional specification - Fixed metallized polypropylene film dielectric AC and pulse capacitors
Corrigendum 1 - Fixed capacitors for use in electronic equipment - Part 17: Sectional specification - Fixed metallized polypropylene film dielectric AC and pulse capacitors
Corrigendum 1 - Condensateurs fixes utilisés dans les équipements électroniques - Partie 17: Spécification intermédiaire: Condensateurs fixes pour tension alternative et pour impulsions à diélectrique en film de polypropylène métallisé
General Information
Relations
Buy Standard
Standards Content (Sample)
IEC 2020
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 60384-17 IEC 60384-17
Edition 3.0 2019-03 Édition 3.0 2019-03
FIXED CAPACITORS FOR USE IN ELECTRONIC CONDENSATEURS FIXES UTILISÉS DANS LES
EQUIPMENT – ÉQUIPEMENTS ÉLECTRONIQUES –
Part 17: Sectional specification – Partie 17: Spécification intermédiaire –
Fixed metallized polypropylene film dielectric AC Condensateurs fixes pour tension alternative et
and pulse capacitors pour impulsions à diélectrique en film de
polypropylène métallisé
CO RRI G E NDUM 1
Corrections to the French version appear after the English text.
Les corrections applicables à la version française sont publiées après celles applicables à la
version anglaise.
CONTENTS
Add Subclause 4.16 Sealing (if required)
Table 3 – Test and sampling plan for qualification approval, assessment level EZ Replace
Table 3 with the following new table:
IEC 60384-17:2019-03/COR1:2020-12(en-fr)
– 2 – IEC 60384-17:2019/COR1:2020
IEC 2020
Group Test Subclause Number of specimens (n)
No. and permissible number of non-conforming items
(c)
Per For four or less For six values
b b
values
value to be tested
b
c
to be tested
n 4 n 6 n
4.1
Visual examination
1.6
Marking
4.1
Dimensions
4.2.2 29 116 174
Capacitance
4.2.3
Tangent of loss angle
4.2.1
Voltage proof
4.2.4
Insulation resistance
d d d d
4.2.5
Inductance (+5) (+20) (+30)
d
4.16 d d d
Sealing
(+5) (+20) (+30)
Spare specimens
2 8 12
4.3 3 12 18
1A Robustness of terminations
4.4
Resistance to soldering heat
d 4.14
Component solvent resistance
4.5 6 24 36
Solderability
4.15
Solvent resistance of the marking
4.6
1B Rapid change of temperature
4.7
Vibration
a
4.8 or 4.9
Bump or shock
4.10 9 36 54
1 Climatic sequence
2 Damp heat, steady state without 4.11 5 20 30
voltage
d d d
Damp heat, steady state with (+5) (+20) (+30)
d
voltage
4.12.1 10 40 60
3A Endurance test at 50 Hz/60 HZ
alternating voltage
e
3B d d d
4.12.2
Endurance test with sinusoidal
(+5) (+20) (+30)
d
current or voltage
e
3C
d
d d d
Pulse endurance test 4.12.3
(+5) (+20) (+30)
d d d
Characteristics depending on 4.2.6
(+5) (+20) (+30)
d
4 temperature
c c c
c 5 20 30
4.13
Charge and discharge
a
As required in the detail specification.
b
Capacitance-voltage combinations, see 3.4.2.
c
Not required when pulse endurance test is required.
d
If required in the detail specification.
Add Subclause 4.16 as follows:
4.16 Sealing (if required)
See IEC 60384-1:2016, 4.20.
A.1 General
In the first line, replace "2.1.2" by "2.1".
IEC 2020
A.2 Humidity robustness grades
Grade (I) robustness under humidity
st
Replace the 1 paragraph with the following text:
An additional sample shall be tested with rated AC voltage applied. See 2.1 and 4.11.3, b).
Grade (II) robustness under high humidity
st
Replace the 1 paragraph with the following text:
An additional sample shall be test
...