Quartz crystal units of assessed quality - Part 3: Standard outlines and lead connections

Specifies the outline dimensions and lead connections of quartz crystal units with lead enclosures.

Résonateurs à quartz sous assurance de la qualité - Partie 3: Encombrements normalisés et connexions des sorties

Spécifie les encombrements normalisés et les connexions des sorties des résonateurs à quartz comportant des enveloppes avec sorties.

General Information

Status
Published
Publication Date
25-Jul-2001
Current Stage
DELPUB - Deleted Publication
Start Date
11-Oct-2010
Completion Date
26-Oct-2025
Ref Project

Relations

Standard
IEC 60122-3:2001 - Quartz crystal units of assessed quality - Part 3: Standard outlines and lead connections Released:7/26/2001 Isbn:2831858496
English and French language
63 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NORME CEI
INTERNATIONALE IEC
60122-3
INTERNATIONAL
Troisième édition
STANDARD
Third edition
2001-07
Résonateurs à quartz sous assurance
de la qualité –
Partie 3:
Encombrements normalisés et connexions
des sorties
Quartz crystal units of assessed quality –
Part 3:
Standard outlines and lead connections

Numéro de référence
Reference number
CEI/IEC 60122-3:2001
Numérotation des publications Publication numbering

Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are

sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.

Editions consolidées Consolidated editions

Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its

CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,

respectivement la publication de base, la publication de the base publication incorporating amendment 1 and

base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/catlg-f.htm) vous permet de faire des (www.iec.ch/catlg-e.htm) enables you to search
recherches en utilisant de nombreux critères, by a variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations line information is also available on recently
en ligne sont également disponibles sur les issued publications, withdrawn and replaced
nouvelles publications, les publications rempla- publications, as well as corrigenda.
cées ou retirées, ainsi que sur les corrigenda.
• IEC Just Published
• IEC Just Published
Ce résumé des dernières publications parues
This summary of recently issued publications
(www.iec.ch/JP.htm) est aussi disponible par
(www.iec.ch/JP.htm) is also available by email.
courrier électronique. Veuillez prendre contact
Please contact the Customer Service Centre (see
avec le Service client (voir ci-dessous) pour plus
below) for further information.
d’informations.
• Service clients
• Customer Service Centre
Si vous avez des questions au sujet de cette
If you have any questions regarding this
publication ou avez besoin de renseignements
publication or need further assistance, please
supplémentaires, prenez contact avec le Service
contact the Customer Service Centre:
clients:
Email: custserv@iec.ch
Email: custserv@iec.ch
Tél: +41 22 919 02 11
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00
Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE IEC
60122-3
INTERNATIONAL
Troisième édition
STANDARD
Third edition
2001-07
Résonateurs à quartz sous assurance
de la qualité –
Partie 3:
Encombrements normalisés et connexions
des sorties
Quartz crystal units of assessed quality –
Part 3:
Standard outlines and lead connections

 IEC 2001 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
V
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 60122-3  CEI:2001
SOMMAIRE
Pages
AVANT-PROPOS . 4

INTRODUCTION .8

Articles
1 Domaine d'application.10

2 Guide de normalisation des dessins d’encombrement des dispositifs pour la
commande et le choix de la fréquence .10
3 Dimensions des enveloppes des résonateurs à quartz .14
4 Désignation des enveloppes des résonateurs à quartz.14
Feuilles de spécification 1 à 22 . 18 à 60
Bibliographie .62

60122-3  IEC:2001 – 3 –
CONTENTS
Page
FOREWORD . 5

INTRODUCTION .9

Clause
1 Scope .11

2 Guidance for the standardization of outline drawings for frequency control and
selection devices .11
3 Dimensions of quartz crystal unit enclosures .15
4 Designation of quartz crystal unit enclosures .15
Specification sheets 1 to 22 .19 to 61
Bibliography.63

– 4 – 60122-3  CEI:2001
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

___________
RÉSONATEURS À QUARTZ SOUS ASSURANCE DE LA QUALITÉ –

Partie 3: Encombrements normalisés et connexions des sorties

AVANT-PROPOS
1) La CEI (Commission Électrotechnique Internationale) est une organisation mondiale de normalisation

composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes
internationales. Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national
intéressé par le sujet traité peut participer. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement
avec l'Organisation Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les
deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, spécifications techniques, rapports techniques ou guides et agréés comme tels par les
Comités nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 60122-3 a été établie par le comité d'études 49 de la CEI:
Dispositifs piézoélectriques et diélectriques pour la commande et le choix de la fréquence.
Le texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
49/493/FDIS 49/508/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant

abouti à l'approbation de cette norme.
Cette troisième édition annule et remplace la deuxième édition parue en 1977, la modification
1 (1984), l’amendement 2 (1991), l’amendement 3 (1992) et l’amendement 4 (1993). Cette
troisième édition constitue une révision technique.
Cette publication a été rédigée selon les Directives ISO/CEI, Partie 3.
La CEI 60122 comprendra, après révision, les parties suivantes présentées sous le titre
général: Résonateurs à quartz sous assurance de la qualité:
– Partie 1: Spécification générique (actuellement CEI 61178-1)
– Partie 2: Guide pour l’emploi des résonateurs à quartz pour le contrôle et la sélection de
la fréquence
– Partie 3: Encombrements normalisés et connexions des sorties

60122-3  IEC:2001 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION

___________
QUARTZ CRYSTAL UNITS OF ASSESSED QUALITY –

Part 3: Standard outlines and lead connections

FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International
Organization for Standardization (ISO) in accordance with conditions determined by agreement between the
two organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60122-3 has been prepared by IEC technical committee 49:
Piezoelectric and dielectric devices for frequency control and selection.
The text of this standard is based on the following documents:
FDIS Report on voting
49/493/FDIS 49/508/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This third edition cancels and replaces the second edition published in 1977, amendment 1
(1984), amendment 2 (1991), amendment 3 (1992) and amendment 4 (1993). This third
edition constitutes a technical revision.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 3.
IEC 60122 will consist, after revision, of the following parts under the general title: Quartz
crystal units of assessed quality:
– Part 1: Generic specification (IEC 61178-1 at present)
– Part 2: Guide to the use of quartz crystal units for frequency control and selection
– Part 3: Standard outlines and lead connections

– 6 – 60122-3  CEI:2001
– Partie 4: Spécification intermédiaire – Agrément de savoir-faire (actuellement CEI 61178-2)

– Partie 4-1: Spécification intermédiaire – Agrément de savoir-faire – Section 1:

Spécification particulière cadre (actuellement CEI 61178-2-1)

– Partie 5: Spécification intermédiaire – Homologation (actuellement CEI 61178-3)

– Partie 5-1: Spécification intermédiaire – Homologation – Section 1: Spécification

particulière cadre (actuellement CEI 61178-3-1).

Le comité a décidé que le contenu de cette publication ne sera pas modifié avant 2006.

A cette date, la publication sera

• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
60122-3  IEC:2001 – 7 –
– Part 4: Sectional specification – Capability approval (IEC 61178-2 at present)

– Part 4-1: Sectional specification – Capability approval – Section 1: Blank detail

specification (IEC 61178-2-1 at present)

– Part 5: Sectional specification – Qualification approval (IEC 61178-3 at present)

– Part 5-1: Sectional specification – Qualification approval – Section 1: Blank detail

specification (IEC 61178-3-1 at present).

The committee has decided that the contents of this publication will remain unchanged until

2006. At this date, the publication will be

• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
– 8 – 60122-3  CEI:2001
INTRODUCTION
La deuxième édition de la CEI 60122-3 (1977) et ses amendements 1 à 4 contient 51 types

d’enveloppes avec leurs caractéristiques dimensionnelles et géométriques. Depuis sa

publication, beaucoup d’enveloppes normalisées sont devenues périmées, suite aux progrès

de la technologie.
De ce fait, le comité d’études 49 a publié un questionnaire sur toutes les enveloppes de la

CEI 60122-3. Il a décidé, lors de la réunion tenue à Rotterdam en juin 1996, sur la base des

réponses obtenues, de ne retenir que «les enveloppes largement utilisées». Ces enveloppes

sont spécifiées dans la présente norme.

Les 24 enveloppes suivantes ont été supprimées de la deuxième édition de la CEI 60122-3
(1977) et ses amendements 1 à 4:
BG,    BG/1,    BH,     BH/1,   BH/2,    BJ, BJ/1,
BJ/2,     CL,    DB,    DD,     DE,     DF,  DG,
DH,     EF,    EG,     CU 03 A., CU 03 B., CU 03 C.,
CU 03 .1, CU 03 .2, CU 04 .2, CU 05 D.

60122-3  IEC:2001 – 9 –
INTRODUCTION
The second edition of IEC 60122-3 (1977) and its amendments 1 to 4 contained 51 enclosure

types showing the dimensional and geometrical characteristics of these enclosures. Since its

release, due to progress in technology, many of the enclosures given in the standard have

become obsolete.
Bearing this in mind, technical committee 49 has issued a questionnaire on all outlines

contained in IEC 60122-3. Based on the replies received, technical committee 49 made a

decision at the meeting held in Rotterdam in June 1996 to retain only enclosures which

remained in “wide usage”. These enclosures are specified in the present standard.

The following 24 enclosure types have been deleted from the second edition of IEC 60122-3
(1977) and its amendments 1 to 4.
BG,    BG/1,    BH,     BH/1,   BH/2,    BJ, BJ/1,
BJ/2,     CL,    DB,    DD,     DE,     DF,  DG,
DH,     EF,    EG,     CU 03 A., CU 03 B., CU 03 C.,
CU 03 .1, CU 03 .2, CU 04 .2, CU 05 D.

– 10 – 60122-3  CEI:2001
RÉSONATEURS À QUARTZ SOUS ASSURANCE DE LA QUALITÉ –

Partie 3: Encombrements normalisés et connexions des sorties

1 Domaine d'application
La présente partie de la CEI 60122 spécifie les encombrements normalisés et les connexions

des sorties des résonateurs à quartz comportant des enveloppes avec sorties.

2 Guide de normalisation des dessins d’encombrement des dispositifs pour la
commande et le choix de la fréquence
Afin d’assurer une présentation uniforme de tous les dessins d’encombrement des dispositifs
pour la commande et le choix de la fréquence, les points suivants doivent être suivis.
2.1 On doit indiquer, sur un dessin d’encombrement, toutes les caractéristiques dimension-
nelles et géométriques d’une enveloppe nécessaires pour assurer l’interchangeabilité
mécanique avec toute autre enveloppe de même encombrement. On peut le compléter, si
besoin est, par une vue agrandie des détails.
2.2 Le dessin d’encombrement doit être présenté en trois parties:
2.2.1 Un dessin sur lequel les cotes sont symbolisées par des lettres majuscules, comme le
montre la figure 1, avec des renvois à des notes, si nécessaire.
2.2.2 Un tableau fournissant les valeurs réelles des dimensions attribuées aux symboles du
dessin, ce tableau devant être, dans la mesure du possible, sur la même page que le dessin.
2.2.3 Une représentation grandeur nature (échelle 1:1).
2.3 Les dessins d’encombrement doivent être exécutés selon la méthode de projection du
troisième dièdre.
2.4 La fonction et l’identification des sorties (bornes) faisant l’objet d’un accord entre le
fournisseur et l’utilisateur, on ne doit pas les définir sur le dessin d’encombrement.

2.5 Des notes descriptives peuvent être utilisées sous ou sur les côtés du dessin
d’encombrement avec un renvoi approprié au corps du dessin.
2.6 Toutes les dimensions doivent être indiquées en millimètres.
2.7 Pour les cotes d’encombrement A, B, C, D et E, on ne doit indiquer que leur valeur
maximale.
2.8 Pour les cotes en coupe des sorties (bornes), on doit indiquer leurs valeurs maximale et
minimale; si cela est applicable, leur valeur nominale peut être ajoutée.
2.9 L’espacement des sorties (bornes) – symbole H – doit être exprimé avec ses valeurs
maximale, minimale et nominale.

60122-3  IEC:2001 – 11 –
QUARTZ CRYSTAL UNITS OF ASSESSED QUALITY –

Part 3: Standard outlines and lead connections

1 Scope
This part of IEC 60122 specifies the outline dimensions and lead connections of quartz crystal

units with lead enclosures.
2 Guidance for the standardization of outline drawings for frequency control
and selection devices
In order to achieve a uniform presentation of all outline drawings for frequency control and
selection devices, the following shall be considered.
2.1 An outline drawing shall show all dimensional and geometrical characteristics of an
enclosure necessary to ensure mechanical interchangeability with all other enclosures of the
same outline. Enlarged detail view may be used, if necessary.
2.2 The outline drawing shall consist of three parts:
2.2.1 A drawing with dimensional symbols (capital letter) as shown in figure 1 with
applicable notes, if necessary.
2.2.2 A tabular listing relating the drawing symbols to the actual dimensions. Where
possible, this shall be shown on the same page as the drawing.
An “actual-size” sketch (scale 1:1).
2.2.3
2.3 The outline drawing shall be executed in the third-angle projection.
2.4 The function and identification of the lead connections (termination) shall be determined
by agreement between the supplier and user. They shall not be defined on the outline
drawing.
2.5 Descriptive notes may be used at the bottom of, or adjacent to, the drawing with proper
reference to the body of the drawing.
2.6 All dimensions shall be in millimetres.
2.7 Outline dimensions A, B, C, D and E shall be listed with maximum values only.
2.8 Lead (termination) cross-sectional dimensions shall be listed with minimum and
maximum values. If applicable, nominal dimensions may be added.
2.9 The spacing of the leads (termination) – symbol H – shall be listed with minimum,
nominal and maximum dimensions.

– 12 – 60122-3  CEI:2001
E
D
Echelle 1:1
C
U
L
W
H
K B
A
IEC  842/01
Dimensions (mm)
Notes
Réf.
Types
Min. Nom. Max.

A – x
B – – x
C –– x
D –– x
E –– x
H xxx
K x–x 1
L x–x
U
x– – 2
W x– – 2
NOTE 1 ….
NOTE 2 ….
Echelle
2:1
Figure 1 – Guide pour les dessins d’encombrement
Feuille … Date:
60122-3  IEC:2001 – 13 –
E
D
Actual size
C
U
L
W
H
B
K
A
IEC  842/01
Dimensions (mm)
Notes
Ref.
Types
Min. Nom. Max.

A – x
B – – x
C –– x
D –– x
E –– x
H xxx
K x–x 1
L x–x
U
x– – 2
W x– – 2
NOTE 1 ….
NOTE 2 ….
Scale
2:1
Figure 1 – Guidance for outline drawings
Sheet … Date:
– 14 – 60122-3  CEI:2001
2.10 Pour les sorties (bornes) à braser, on doit spécifier seulement la valeur minimale de
leur longueur (symbole L).
Pour les sorties (bornes) enfichables, on doit spécifier leurs longueurs maximale et minimale.

2.11 Pour les sorties (bornes) comportant une découpe, on doit fournir seulement les
valeurs minimales des dimensions U et W.

3 Dimensions des enveloppes des résonateurs à quartz

Les dimensions précisées dans la présente norme s’appliquent aux résonateurs à quartz finis.
Seules sont données les dimensions qui répondent aux exigences du guide de normalisation
des dessins d’encombrement (voir l’article 2).
4 Désignation des enveloppes des résonateurs à quartz
Tableau 1 – Désignation des enveloppes des résonateurs à quartz
o o
N Type Feuille N Description
AA
Enveloppe d’un résonateur à quartz à deux sorties, métallique,
1 Feuille 1
fermée par soudage à l’étain
AB
BC
Enveloppe d’un résonateur à quartz à deux sorties, métallique,
2 Feuille 2
fermée par soudage à l’étain
BC/1
BF
Enveloppe d’un résonateur à quartz à deux sorties, métallique,
3 Feuille 3
fermée par soudage à l’étain
BF/1
CK, CM
Enveloppe d’un résonateur à quartz à trois sorties, métallique,
4 Feuille 4
soudée
CN, CP
5 CX Feuille 5 Enveloppe d’un résonateur à quartz à deux sorties, métallique,
fermée par soudage à l’étain
CY, CY/1
6 Feuille 6 Enveloppe d’un résonateur à quartz en verre à deux sorties
CZ
DA
7 Feuille 7 Enveloppe d’un résonateur à quartz en verre à deux sorties
DC
Enveloppe d’un résonateur à quartz à trois sorties, métallique,
8 DK Feuille 8
soudée
Enveloppe d’un résonateur à quartz à cinq sorties,
9 DL Feuille 9
métallique, soudée
Enveloppe d’un résonateur à quartz à deux sorties, métallique,
10 DN Feuille 10
soudée
DP
Enveloppe d’un résonateur à quartz à deux sorties, métallique,
11 Feuille 11
soudée
EH
Enveloppe d’un résonateur à quartz à deux sorties, métallique,
12 DQ Feuille 12
soudée
Enveloppe d’un résonateur à quartz à quatre sorties, métallique,
13 DR Feuille 13
soudée
Enveloppe d’un résonateur à quartz à deux sorties, métallique,
14 DZ Feuille 14
soudée
Enveloppe d’un résonateur à quartz cylindrique à deux sorties,
15 DV Feuille 15
métallique, fermée par diffusion à l’étain

60122-3  IEC:2001 – 15 –
2.10 Leads (terminations) for soldering application shall be specified with the minimum
length dimensions (symbol L) only.

Leads (terminations) for plug-in application shall be specified with minimum and maximum

length dimensions.
2.11 If leads (terminations) are provided with an undercut, dimensions U and W shall be

listed with minimum dimensions only.

3 Dimensions of quartz crystal unit enclosures

The dimensions in this standard apply to the completed quartz crystal units.
Only those dimensions which meet the requirements of the guidance for standardization of
outline drawings are given (see clause 2).
4 Designation of quartz crystal unit enclosures
Table 1 – Designation of quartz crystal unit enclosures
No. Type Sheet No. Description
AA
1 Sheet 1 Metal, solder-sealed, two-lead crystal unit outline
AB
BC
2 Sheet 2 Metal, solder-sealed, two-lead crystal unit outline
BC/1
BF
3 Sheet 3 Metal, solder-sealed, two-lead crystal unit outline
BF/1
CK, CM
4 Sheet 4 Metal, welded, three-lead crystal unit outline
CN, CP
5 CX Sheet 5 Metal, solder-sealed, two-lead crystal unit outline
CY, CY/1
6 Sheet 6 Glass, two-lead crystal unit outline
CZ
DA
7 Sheet 7 Glass, two-lead crystal unit outline
DC
8 DK Sheet 8 Metal, welded, three-lead crystal unit outline
9 DL Sheet 9 Metal, welded, five-lead crystal unit outline

10 DN Sheet 10 Metal, welded, two-lead crystal unit outline
DP
11 Sheet 11 Metal, welded, two-lead crystal unit outline
EH
12 DQ Sheet 12 Metal, welded, two-lead crystal unit outline
13 DR Sheet 13 Metal, welded, four-lead crystal unit outline
14 DZ Sheet 14 Metal, welded, two-lead crystal unit outline
Metal, solder-diffusion-sealed, two-lead cylindrical crystal unit
15 DV Sheet 15
outline
– 16 – 60122-3  CEI:2001
Tableau 1 – Désignation des enveloppes des résonateurs à quartz (suite)

o o
N Type Feuille N Description
Enveloppe d’un résonateur à quartz cylindrique à deux sorties,
16 DW Feuille 16
métallique, fermée par diffusion à l’étain

Enveloppe d’un résonateur à quartz cylindrique à deux sorties,
17 ED Feuille 17
métallique, fermée par diffusion à l’étain

EB, EJ
Enveloppe d’un résonateur à quartz à deux sorties, métallique,
18 Feuille 18
soudée
EK
CU 01 A.
CU 01 B.
CU 01 C.
Enveloppe d’un résonateur à quartz à deux sorties, métallique,
19 Feuille 19
soudée, destinée à l’assemblage automatique
CU 01 D.
CU 01 E.
CU 01 F.
CU 02 A.
CU 02 B.
CU 02 C.
Enveloppe d’un résonateur à quartz à deux sorties, métallique,
20 Feuille 20
soudée, destinée à l’assemblage automatique
CU 02 D.
CU 02 E.
CU 02 F.
CU 04 A.
CU 04 B.
Enveloppe d’un résonateur à quartz à deux sorties, métallique,
21 Feuille 21
soudée, destinée à l’assemblage automatique
CU 04 C.
CU 04 D.
CU 05 A.
Enveloppe d’un résonateur à quartz à deux sorties, métallique,
22 CU 05 B. Feuille 22
soudée, destinée à l’assemblage automatique
CU 05 C.
60122-3  IEC:2001 – 17 –
Table 1 – Designation of quartz crystal unit enclosures (continued)

No. Type Sheet No. Description

Metal, solder-diffusion-sealed, two-lead cylindrical crystal unit
16 DW Sheet 16
outline
Metal, solder-diffusion-sealed, two-lead cylindrical crystal unit
17 ED Sheet 17
outline
EB, EJ
18 Sheet 18 Metal, welded, two-lead crystal unit outline

EK
CU 01 A.
CU 01 B.
CU 01 C.
19 Sheet 19 Metal, welded, two-lead crystal unit outline for automatic handling
CU 01 D.
CU 01 E.
CU 01 F.
CU 02 A.
CU 02 B.
CU 02 C.
20 Sheet 20 Metal, welded, two-lead crystal unit outline for automatic handling
CU 02 D.
CU 02 E.
CU 02 F.
CU 04 A.
CU 04 B.
21 Sheet 21 Metal, welded, two-lead crystal unit outline for automatic handling
CU 04 C.
CU 04 D.
CU 05 A.
22 CU 05 B. Sheet 22 Metal, welded, two-lead crystal unit outline for automatic handling
CU 05 C.
– 18 – 60122-3  CEI:2001
(Type AA)
E
D
C
L
H
K B
A
IEC  843/01
Dimensions (mm)
Notes
Réf.
Types
Min. Nom. Max.
A – –  19,23  3
B – –   8,94  3
C – –  19,68  Type AA
C – –  38,76  Type AB
D – –  18,41
E – –   8,05
H 12,14  12,35  12,55
K  1,22   1,27   1,32  1
L  5,66 –   6,30
NOTE 1 Extrémités des sorties arrondies.
NOTE 2 Lorsque cela est exigé, les sorties peuvent être prévues avec l’échancrure.
NOTE 3 Les dimensions A et B sont indiquées congés de soudure compris.
Echelle
Enveloppe d’un résonateur à quartz à deux sorties,
1:1
métallique, fermée par soudage à l’étain −
Type AA et AB
Feuille 1 Date: 2001-07
60122-3  IEC:2001 – 19 –
(Type AA)
E
D
C
L
H
K B
A
IEC  843/01
Dimensions (mm)
Notes
Ref.
Types
Min. Nom. Max.
A – –  19,23  3
B – –   8,94  3
C – –  19,68  Type AA
C – –  38,76  Type AB
D – –  18,41
E – –   8,05
H 12,14  12,35  12,55
K  1,22   1,27   1,32  1
L  5,66 –   6,30
NOTE 1 Lead ends rounded.
NOTE 2 If required, leads may be provided with an undercut.
NOTE 3 A and B dimensions include an allowance for solder.
Scale
Metal, solder-sealed, two-lead crystal unit outline −
1:1
Type AA and AB
Sheet 1 Date: 2001-07
– 20 – 60122-3  CEI:2001
E
D
Echelle 1:1
C
Type BC
L
H
K
B
A
IEC  844/01
Dimensions (mm)
Notes
Réf.
Types
Min. Nom. Max.
A – –  11,05  1
B – –   4,65  1
C – –  13,46
D – –  10,21
E – –   3,81
H 4,67 4,90   5,08
K  0,40 –   0,48
L 38,10 – –  Type BC
L 12,70 – –  Type BC/1
NOTE 1 Les dimensions A et B sont indiquées congés de soudure compris.
Echelle
Enveloppe d’un résonateur à quartz à deux sorties,
2:1
métallique, fermée par soudage à l’étain −
Type BC et BC/1
Feuille 2 Date: 2001-07
60122-3  IEC:2001 – 21 –
E
D
Actual size
C
Type BC
L
H
K
B
A
IEC  844/01
Dimensions (mm)
Notes
Ref.
Types
Min. Nom. Max.
A – –  11,05  1
B – –   4,65  1
C – –  13,46
D – –  10,21
E – –   3,81
H 4,67 4,90   5,08
K  0,40 –   0,48
L 38,10 – –  Type BC
L 12,70 – –  Type BC/1
NOTE 1 A and B dimensions include an allowance for solder.
Scale
Metal, solder-sealed, two-lead crystal unit outline −
2:1
Type BC and BC/1
Sheet 2 Date:2001-07
– 22 – 60122-3  CEI:2001
D
E (Type BF)
C
L
H
K B
A
IEC  845/01
Dimensions (mm)
Notes
Réf.
Types
Min. Nom. Max.
A – –  19,23  1
B – –   8,94  1
C – –  19,63 Type BF, BF/1
D – –  18,41
E – –   8,05
H 12,14 12,35  12,55
K  0,70 –   0,80
L 38,10 – –  Type BF
L 12,70 – –  Type BF/1
NOTE 1 Les dimensions A et B sont indiquées congés de soudure compris.
Enveloppe d’un résonateur à quartz à deux sorties, Echelle
1:1
métallique, fermée par soudage à l’étain −
Type BF et BF/1
Feuille 3 Date: 2001-07
60122-3  IEC:2001 – 23 –
D
E (Type BF)
C
L
H
K B
A
IEC  845/01
Dimensions (mm)
Notes
Ref.
Types
Min. Nom. Max.
A – –  19,23  1
B – –   8,94  1
C – –  19,63 Type BF, BF/1
D – –  18,41
E – –   8,05
H 12,14 12,35  12,55
K  0,70 –   0,80
L 38,10 – –  Type BF
L 12,70 – –  Type BF/1
NOTE 1 A and B dimensions include an allowance for solder.
Scale
Metal, solder-sealed, two-lead crystal unit outline −
1:1
Type BF and BF/1
Sheet 3 Date: 2001-07
– 24 – 60122-3  CEI:2001
D
C
L
Echelle 1:1
Actual size
Type CK
Type CK
K
H
A
Note 1
IEC  846/01
Dimensions (mm)
Notes
Réf.
Types
Min. Nom. Max.
A – –   9,39
C – –   6,60  Type CK
C – –  25,40  Type CM
C – –  39,37  Type CN
C – –  59,69  Type CP
D – –   8,51
H  4,83 5,08   5,33
K  0,40 –   0,48
L 15,24 – –
o
NOTE 1 La mise à la masse se fait par la sortie n 2 reliée à l’enveloppe.
NOTE 2 Le modèle d’enveloppe de quartz indiqué sur cette feuille peut être fermé par «soudage à froid» ou par
«soudage par résistance»; la distinction se fait par la lettre «C» pour la forme fermée par soudage à froid ou par
la lettre «R» pour la forme fermée par soudage par résistance, en ajoutant cette lettre à la fin du code du type (par
exemple CKC ou CKR).
Enveloppe d’un résonateur à quartz à trois sorties, Echelle
2:1
métallique, soudée − Type CK, CM, CN et CP
Feuille 4 Date: 2001-07
60122-3  IEC:2001 – 25 –
D
C
L
Actual size
Type CK
K
H
A
Note 1
IEC  846/01
Dimensions (mm)
Notes
Ref.
Types
Min. Nom. Max.
A – –   9,39
C – –   6,60  Type CK
C – –  25,40  Type CM
C – –  39,37  Type CN
C – –  59,69  Type CP
D – –   8,51
H  4,83 5,08   5,33
K  0,40 –   0,48
L 15,24 – –
NOTE 1 Lead No. 2 is grounded to case.
NOTE 2 The crystal unit outline shown in this sheet can be manufactured in either “cold-welded” or “resistance-
welded” form and is distinguished by the letter “C” for the cold-welded or the letter “R” for the resistance-welded
form by adding the letter at the end of the type code (e.g. CKC or CKR).
Scale
Metal, welded, three-lead crystal unit outline −
2:1
Type CK, CM, CN and CP
Sheet 4 Date: 2001-07
– 26 – 60122-3  CEI:2001
E
D
Echelle
Actual size
1:1
C
U
L
W
H
K B
A
IEC  847/01
Dimensions (mm)
Notes
Réf.
Types
Min. Nom. Max.
A
– –  11,05  3
B – –   4,65  3
C – –  13,46
D – –  10,21
E – –   3,81
H  4,67  4,90   5,08
K  0,97  1,00   1,07  1
L
5,66 –   6,30
U  0,69 – –
W   4,45 – –
NOTE 1 Extrémités des sorties arrondies.
NOTE 2 Forme de la gorge au choix du fabricant.
NOTE 3 Les dimensions A et B sont indiquées congés de soudure compris.
Enveloppe d’un résonateur à quartz à deux sorties, Echelle
2:1
métallique, fermée par soudage à l’étain − Type CX
Feuille 5 Date: 2001-07
60122-3  IEC:2001 – 27 –
E
D
Actual size
C
U
L
W
H
K B
A
IEC  847/01
Dimensions (mm)
Notes
Ref.
Types
Min. Nom. Max.
A
– –  11,05  3
B – –   4,65  3
C – –  13,46
D – –  10,21
E – –   3,81
H  4,67  4,90   5,08
K  0,97  1,00   1,07  1
L
5,66 –   6,30
U  0,69 – –
W   4,45 – –
NOTE 1 Lead ends rounded.
NOTE 2 Shape of undercut at the discretion of the manufacturer.
NOTE 3 A and B dimensions include an allowance for solder.
Scale
Metal, solder-sealed, two-lead crystal unit outline − Type CX
2:1
Sheet 5 Date: 2001-07
– 28 – 60122-3  CEI:2001
E
D
Echelle
Actual size
C
1:1
L
N
U
K
L
W
B
K
H
A
IEC  848/01
Dimensions (mm)
Notes
Réf.
Types
Min. Nom. Max.
A – –  11,04
B – –   4,70
C – –  13,46
D – –  10,60
E
– –   4,20
H  4,67  4,90   5,08
K  0,97 1,00   1,07  1
L  5,66 –   6,30
U  0,69 – –  Type CZ, 2
W
4,45 – –
K  0,40 –   0,48  Type CY
L  38,10 – –  Type CY
L  12,70 – –  Type CY/1
N – –   1,02
Notes pour le type CZ
NOTE 1 Extrémités des broches arrondies.
NOTE 2 Forme de la gorge au choix du fabricant.
Enveloppe d’un résonateur à quartz en verre à deux Echelle
2:1
sorties − Type CY, CY/1 et CZ
Feuille 6 Date: 2001-07
60122-3  IEC:2001 – 29 –
E
D
C
Actual size
L
N
U
K
L
W
B
K
H
A
IEC  848/01
Dimensions (mm)
Notes
Ref.
Types
Min. Nom. Max.
A – –  11,04
B – –   4,70
C – –  13,46
D – –  10,60
E
– –   4,20
H  4,67  4,90   5,08
K  0,97 1,00   1,07  1
L  5,66 –   6,30
U  0,69 – –  Type CZ, 2
W
4,45 – –
K  0,40 –   0,48  Type CY
L  38,10 – –  Type CY
L  12,70 – –  Type CY/1
N – –   1,02
Notes for Type CZ
NOTE 1 Pin ends rounded.
NOTE 2 Shape of undercut at the discretion of the manufacturer.
Scale
Glass, two-lead crystal unit outline −
2:1
Type CY, CY/1 and CZ
Sheet 6 Date: 2001-07
– 30 – 60122-3  CEI:2001
E
D
C
U
Voir note 1
F
L
W
K
B
H
A
IEC  849/01
Dimensions (mm)
Notes
Réf.
Types
Min. Nom. Max.
A – –  19,22
B – –   8,94
C – –  19,68  Type DA
C – –  38,76  Type DC
D
– –  18,41
E – –   8,12
F – –   5,08  3
H  12,14  12,35  12,55
K   1,22   1,27   1,32  1
L
5,66 –   6,30
U   0,76 – –  2
W   4,45 – –
NOTE 1 Extrémités des sorties arrondies.
NOTE 2 Forme de la gorge au choix du fabricant.
NOTE 3 Il faut que les dimensions D et E soient mesurées au-dessus de la limite définie par la dimension F.
Enveloppe d’un résonateur à quartz en verre à deux Echelle
1:1
sorties − Type DA et DC
Feuille 7 Date: 2001-07
60122-3  IEC:2001 – 31 –
E
D
C
U
See note 1
F
L
W
K
B
H
A
IEC  849/01
Dimensions (mm)
Notes
Ref.
Types
Min. Nom. Max.
A – –  19,22
B – –   8,94
C – –  19,68  Type DA
C – –  38,76  Type DC
D
– –  18,41
E – –   8,12
F – –   5,08  3
H  12,14  12,35  12,55
K   1,22   1,27   1,32  1
L
5,66 –   6,30
U   0,76 – –  2
W   4,45 – –
NOTE 1 Lead ends rounded.
NOTE 2 Shape of undercut at the discretion of the manufacturer.
NOTE 3 Dimensions D and E must be measured above the limit defined by dimension F.
Scale
Glass, two-lead crystal unit outline − Type DA and DC
1:1
Sheet 7 Date: 2001-07
– 32 – 60122-3  CEI:2001
A
D
C
Echelle 1:1
L
H
K
P
Q
IEC  850/01
Dimensions (mm)
Notes
Réf.
Types
Min. Nom. Max.
A – –  10,70
C – –   6,60
D – –   8,50
H  4,83 5,08   5,33
K  0,40 –   0,48
L 12,70 – –
P – –   0,90  2
Q – –   0,95  2
o
NOTE 1 La mise à la masse se fait par la sortie n 3 reliée à l’enveloppe.
NOTE 2 L’ergot et son emplacement sont facultatifs.
NOTE 3 Le modèle d’enveloppe de quartz indiqué sur cette feuille peut être fermé par «soudage à froid» ou par
«soudage par résistance»; la distinction se fait par la lettre «C» pour la forme fermée par soudage à froid ou par
la lettre «R» pour la forme fermée par soudage par résistance, en ajoutant cette lettre à la fin du code du type
(par exemple DKC ou DKR).
Enveloppe d’un résonateur à quartz à trois sorties, Echelle
2:1
métallique, soudée − Type DK
Feuille 8 Date: 2001-07
60122-3  IEC:2001 – 33 –
A
D
C
Actual size
L
H
K
P
Q
IEC  850/01
Dimensions (mm)
Notes
Ref.
Types
Min. Nom. Max.
A – –  10,70
C – –   6,60
D – –   8,50
H  4,83 5,08   5,33
K  0,40 –   0,48
L 12,70 – –
P – –   0,90  2
Q – –   0,95  2
NOTE 1 Lead No. 3 is grounded to case.
NOTE 2 The tag’s position or presence is optional.
NOTE 3 The crystal unit outline shown in this sheet can be manufactured in either “cold-welded” or “resistance-
welded” form and is distinguished by the letter “C” for the cold-welded or the letter “R” for the resistance-welded
form by adding the letter at the end of the type code (e.g. DKC or DKR).
Scale
Metal, welded, three-lead crystal unit outline − Type DK
2:1
Sheet 8 Date: 2001-07
– 34 – 60122-3  CEI:2001
A
D
C
Echelle 1:1
L
H
P
Q
K
IEC  851/01
Dimensions (mm)
Notes
Réf.
Types
Min. Nom. Max.
A – –  15,75
C – –   6,60
D – –  13,30
H 6,90 7,16   7,40
K 0,40 –   0,48
L 12,70 –   –
P – –   0,90  2
Q – –   0,95  2
o
NOTE 1 La mise à la masse se fait par la sortie n 5 reliée à l’enveloppe.
NOTE 2 L’ergot et son emplacement sont facultatifs.
NOTE 3 Le modèle d’enveloppe de quartz indiqué sur cette feuille peut être fermé par «soudage à froid» ou par
«soudage par résistance»; la distinction se fait par la lettre «C» pour la forme fermée par soudage à froid ou par la
lettre «R» pour la forme fermée par soudage par résistance, en ajoutant cette lettre à la fin du code du type (par
exemple DLC ou DLR).
Enveloppe d’un résonateur à quartz à cinq sorties, Echelle
2:1
métallique, soudée − Type DL
Feuille 9 Date: 2001-07
60122-3  IEC:2001 – 35 –
A
D
C
Actual size
L
H
P
Q
K
IEC  851/01
Dimensions (mm)
Notes
Ref.
Types
Min. Nom. Max.
A – –  15,75
C – –   6,60
D – –  13,30
H 6,90 7,16   7,40
K 0,40 –   0,48
L 12,70 –   –
P – –   0,90  2
Q – –   0,95  2
NOTE 1 Lead No. 5 is grounded to case.
NOTE 2 The tag’s position or presence is optional.
NOTE 3 The crystal unit outline shown in this sheet can be manufactured in either “cold-welded” or “resistance-
welded” form and is distinguished by the letter “C” for the cold-welded or the letter “R” for the resistance-welded form by
adding the letter at the end of the type code (e.g. DLC or DLR).
Scale
Metal, welded, five-lead crystal unit outline − Type DL
2:1
Sheet 9 Date: 2001-07
– 36 – 60122-3  CEI:2001
Rayon nominal
E
D
C
Echelle 1:1
U
L
W
H
Rayon nominal
B
K
A
IEC  852/01
Dimensions (mm)
Notes
Réf.
Types
Min. Nom. Max.
A
– –  19,40
B – –   9,10
C – –  19,75
D – –  18,05
E – –   7,65
H 12,14 12,35  12,55
K  1,22 1,27   1,32
L  5,66 –   6,30  1
U  0,76 – –  2
W  4,45 – –  2
NOTE 1 Extrémités des sorties arrondies.
NOTE 2 La forme de la gorge est au choix du fabricant.
NOTE 3 Le modèle d’enveloppe de quartz indiqué sur cette feuille peut être fermé par «soudage à froid» ou par
«soudage par résistance»; la distinction se fait par la lettre «C» pour la forme fermée par soudage à froid ou par
la lettre «R» pour la forme fermée par soudage par résistance, en ajoutant cette lettre à la fin du code du type
(par exemple DNC ou DNR).
Enveloppe d’un résonateur à quartz à deux sorties, Echelle
2:1
métallique, soudée − Type DN
Feuille 10 Date: 2001-07
60122-3  IEC:2001 – 37 –
Nominal radius
E
D
C
Actual size
U
L
W
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...