Corrigendum 1 - Sound system equipment - Electroacoustical transducers - Measurement of suspension parts

Corrigendum 1 - Equipements pour systèmes électroacoustiques – Transducteurs électroacoustiques – Mesurage des pièces de suspension

General Information

Status
Published
Publication Date
19-Nov-2015
Current Stage
PPUB - Publication issued
Start Date
06-Dec-2015
Completion Date
20-Nov-2015
Ref Project

Relations

Buy Standard

Standard
IEC 62459:2010/COR1:2015 - Corrigendum 1 - Sound system equipment - Electroacoustical transducers - Measurement of suspension parts Released:20. 11. 2015
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
IEC 62459:2010/COR1:2015 - Corrigendum 1 - Sound system equipment - Electroacoustical transducers - Measurement of suspension parts Released:20. 11. 2015
English and French language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

IEC 62459:2010/COR1:2015 – 1 –
 IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

IEC 62459
Edition 1.0  2010-01


Sound system equipment –
Electroacoustical transducers –
Measurement of suspension parts


CO RRI G ENDU M 1




3.11
lowest cone resonance frequency

Replace the existing Formula (7) by the following new Formula:

1 Κ(x )
off
(7)
f ≈

0
2π δm
s




6.3 Incremental dynamic measurement

Replace the existing first sentence by the following:

This technique for measuring the incremental stiffness K (x ) according to Equation (3) uses a
inc dc
superposition of a d.c. signal of certain magnitude (for example, constant restoring force F
dc
generating a d.c. position x ) and a
...

IEC 62459:2010/COR1:2015 – 1 –
 IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

IEC 62459
Edition 1.0  2010-01


Sound system equipment –
Electroacoustical transducers –
Measurement of suspension parts


CO RRI G E NDUM 1




3.11
lowest cone resonance frequency
Replace the existing Formula (7) by the following new Formula:

Κ(x )
1
off
(7)
f ≈

0
2π δm
s




6.3 Incremental dynamic measurement

Replace the existing first sentence by the following:
This technique for measuring the incremental stiffness K (x ) according to Equation (3)
inc dc
uses a superposition of a d.c. signal of certain magnitude (for example, constant restoring
generating a d.c. position x ) and a small a.c. signal (e.g. restoring force F ) as
force F
dc dc ac
stimulus and measures the a.c. response of the suspension part (e.g. the a.c. part of the
displacement x ) under steady-state condition.
ac

6.4 Full dynamic measurement

Replace the existing paragraph by the following:
This technique for measuring the dynamic stiffness K(x ) uses an a.c. signal of certain
ac
magnitude (for example, the a.c. restoring force F ) and measures the a.c. response of the
ac
suspension part (for example, a displacement x ).
ac

9.1 Characteristic to be specified

Replace, in the second sentence of this paragraph, "Equation (6)" by "Equation (1)".

IEC 62459:2010-01/COR1:2015-11(en)