IEC TS 60695-11-3:2000
(Main)Fire hazard testing - Part 11-3: Test flames - 500 W flames - Apparatus and confirmational test methods
Fire hazard testing - Part 11-3: Test flames - 500 W flames - Apparatus and confirmational test methods
Gives the detailed requirements for the production of a nominal 500 W, pre-mixed type test flame. the approximate overall height is 125 mm. Four methods are given: flame A and D may only be produced using methane, flame B may only be produced using propane and flame C may be produced using either methane or propane. Has the status of a basic safety publication in accordance with IEC Guide 104.
Essais relatifs aux risques du feu - Partie 11-3: Flammes d'essai - Flammes de 500 W - Appareillage et méthodes d'essai de vérification
Donne les prescriptions détaillées pour la production d'une flamme d'essai de 500 W (valeur nominale), de type à prémélange. La hauteur totale est de 125 mm approximativement. Quatre méthodes sont décrites: les flammes A et D peuvent seulement être produites en utilisant du méthane; la flamme B peut seulement être produite en utilisant du propane; la flamme C peut être produite en utilisant soit du méthane soit du propane. A le statut d'une publication fondamentale de sécurité conformément au Guide 104 de la CEI.
General Information
- Status
- Published
- Publication Date
- 02-Mar-2000
- Technical Committee
- TC 89 - Fire hazard testing
- Drafting Committee
- WG 12 - TC 89/WG 12
- Current Stage
- DELPUB - Deleted Publication
- Start Date
- 19-Apr-2004
- Completion Date
- 26-Oct-2025
Relations
- Effective Date
- 05-Sep-2023
Overview
IEC TS 60695-11-3:2000 is a Technical Specification published by the International Electrotechnical Commission (IEC) that addresses fire hazard testing through the use of standardized test flames. Specifically, this document focuses on the 500 W test flames, detailing the apparatus and confirmational test methods for producing pre-mixed flames of nominal power 500 watts with an approximate flame height of 125 mm. As a basic safety publication aligned with IEC Guide 104, it provides a structured approach to generating consistent test flames essential for evaluating fire risks in materials and equipment.
This standard specifies four different flame methods (A, B, C, D), each defined by the type of gas used for combustion and the flame characteristics:
- Flame A and D: produced only with methane
- Flame B: produced only with propane
- Flame C: produced with either methane or propane
IEC TS 60695-11-3:2000 ensures uniformity in fire hazard testing practices worldwide, supporting safety evaluations and compliance in electrical and electronic sectors.
Key Topics
Test Flame Apparatus Design
The standard elaborates on precise burner construction, gas supply arrangements, and flame verification setups to reproduce the 500 W flames reliably. Detailed burner components, including barrel, gas injectors, and air manifolds, are described for each test method.Test Methods and Procedures
Four distinct methods (A, B, C, D) outline procedures for flame production and confirmation tests. Each method includes guidelines on assembly, gas flow rates, and flame dimension measurement, ensuring reproducibility and accuracy during fire hazard assessments.Flame Characteristics and Verification
The document sets criteria for flame height (about 125 mm), shape, and temperature profiles. It describes measurement tools and confirmational test arrangements, enabling testers to verify the consistency of the test flames before carrying out fire risk evaluations.Safety and Classification
Designated as a basic safety publication, it defines classification and designation practices for the test flames and apparatus. The standard also discusses recommended usage contexts and precautions to mitigate risks during testing.Annexes and Illustrations
The document contains normative and informative annexes with practical examples of burner assemblies, test setups, and confirmational test arrangements. More than 40 illustrated figures support clear understanding of burner parts and test configuration.
Applications
IEC TS 60695-11-3:2000 is primarily used by manufacturers, testing laboratories, and regulatory bodies involved in:
Fire hazard testing of electrical and electronic materials and devices
It establishes a controlled flame environment to assess material flammability, ignition resistance, and fire propagation behavior.Certification and compliance monitoring
Many certification schemes require testing using standardized flames for fire safety approvals under national and international regulations.Research and development
Provides a reproducible flame source critical for developing flame-retardant materials and improving fire safety designs.Quality assurance in manufacturing
Helps ensure consistency in fire safety characteristics across production batches by utilizing a well-defined testing protocol.
Related Standards
To complement IEC TS 60695-11-3:2000, organizations often refer to other IEC fire hazard and safety standards such as:
- IEC 60695 series – covering various parts of fire hazard testing methods including hot-wire ignition, glow-wire ignition, and test flames of different powers.
- IEC Guide 104 – outlining principles for basic safety publications, under which this technical specification is categorized.
- IEC 60050 (International Electrotechnical Vocabulary) – for standard terminology used in electrotechnical and fire safety fields.
- IEC 60027, 60417, and 60617 – providing graphical and letter symbols relevant to equipment labeling and documentation during testing.
By adhering to IEC TS 60695-11-3:2000 alongside associated standards, stakeholders ensure standardized, reliable, and internationally recognized fire hazard testing outcomes that promote safer product designs and regulatory compliance.
Keywords: IEC TS 60695-11-3, fire hazard testing, 500 W test flames, methane burner, propane burner, electrical fire safety, pre-mixed flame, test flame apparatus, confirmational test methods, fire safety standards, IEC basic safety publication, flame verification, fire testing methods, fire risk assessment.
Frequently Asked Questions
IEC TS 60695-11-3:2000 is a technical specification published by the International Electrotechnical Commission (IEC). Its full title is "Fire hazard testing - Part 11-3: Test flames - 500 W flames - Apparatus and confirmational test methods". This standard covers: Gives the detailed requirements for the production of a nominal 500 W, pre-mixed type test flame. the approximate overall height is 125 mm. Four methods are given: flame A and D may only be produced using methane, flame B may only be produced using propane and flame C may be produced using either methane or propane. Has the status of a basic safety publication in accordance with IEC Guide 104.
Gives the detailed requirements for the production of a nominal 500 W, pre-mixed type test flame. the approximate overall height is 125 mm. Four methods are given: flame A and D may only be produced using methane, flame B may only be produced using propane and flame C may be produced using either methane or propane. Has the status of a basic safety publication in accordance with IEC Guide 104.
IEC TS 60695-11-3:2000 is classified under the following ICS (International Classification for Standards) categories: 13.220.40 - Ignitability and burning behaviour of materials and products; 29.020 - Electrical engineering in general. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC TS 60695-11-3:2000 has the following relationships with other standards: It is inter standard links to IEC TS 60695-11-3:2004. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase IEC TS 60695-11-3:2000 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of IEC standards.
Standards Content (Sample)
SPÉCIFICATION CEI
TECHNIQUE IEC
TS 60695-11-3
TECHNICAL
Première édition
SPECIFICATION
First edition
2000-03
PUBLICATION FONDAMENTALE DE SÉCURITÉ
BASIC SAFETY PUBLICATION
Essais relatifs aux risques du feu –
Partie 11-3:
Flammes d'essai – Flammes de 500 W –
Appareillage et méthodes d'essai de vérification
Fire hazard testing –
Part 11-3:
Test flames – 500 W flames –
Apparatus and confirmational test methods
Numéro de référence
Reference number
IEC/TS 60695-11-3:2000
Numéros des publications Numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. issued with a designation in the 60000 series.
Publications consolidées Consolidated publications
Les versions consolidées de certaines publications de Consolidated versions of some IEC publications
la CEI incorporant les amendements sont disponibles. including amendments are available. For example,
Par exemple, les numéros d’édition 1.0, 1.1 et 1.2 edition numbers 1.0, 1.1 and 1.2 refer, respectively, to
indiquent respectivement la publication de base, la the base publication, the base publication incor-
publication de base incorporant l’amendement 1, et la porating amendment 1 and the base publication
publication de base incorporant les amendements 1 incorporating amendments 1 and 2.
et 2.
Validité de la présente publication Validity of this publication
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. the content reflects current technology.
Des renseignements relatifs à la date de reconfir- Information relating to the date of the reconfirmation
mation de la publication sont disponibles dans le of the publication is available in the IEC catalogue.
Catalogue de la CEI.
Les renseignements relatifs à des questions à l’étude et Information on the subjects under consideration and
des travaux en cours entrepris par le comité technique work in progress undertaken by the technical
qui a établi cette publication, ainsi que la liste des committee which has prepared this publication, as well
publications établies, se trouvent dans les documents ci- as the list of publications issued, is to be found at the
dessous: following IEC sources:
• «Site web» de la CEI* • IEC web site*
• Catalogue des publications de la CEI • Catalogue of IEC publications
Publié annuellement et mis à jour Published yearly with regular updates
(On-line catalogue)*
régulièrement
(Catalogue en ligne)*
• IEC Bulletin
• Bulletin de la CEI Available both at the IEC web site* and
Disponible à la fois au «site web» de la CEI* as a printed periodical
et comme périodique imprimé
Terminology, graphical and letter
Terminologie, symboles graphiques
symbols
et littéraux
For general terminology, readers are referred to
En ce qui concerne la terminologie générale, le lecteur IEC 60050: International Electrotechnical Vocabulary
se reportera à la CEI 60050: Vocabulaire Electro- (IEV).
technique International (VEI).
For graphical symbols, and letter symbols and signs
Pour les symboles graphiques, les symboles littéraux approved by the IEC for general use, readers are
et les signes d'usage général approuvés par la CEI, le referred to publications IEC 60027: Letter symbols to
lecteur consultera la CEI 60027: Symboles littéraux à be used in electrical technology, IEC 60417: Graphical
utiliser en électrotechnique, la CEI 60417: Symboles symbols for use on equipment. Index, survey and
graphiques utilisables sur le matériel. Index, relevé et compilation of the single sheets and IEC 60617:
compilation des feuilles individuelles, et la CEI 60617: Graphical symbols for diagrams.
Symboles graphiques pour schémas.
* See web site address on title page.
* Voir adresse «site web» sur la page de titre.
SPÉCIFICATION CEI
TECHNIQUE IEC
TS 60695-11-3
TECHNICAL
Première édition
SPECIFICATION
First edition
2000-03
PUBLICATION FONDAMENTALE DE SÉCURITÉ
BASIC SAFETY PUBLICATION
Essais relatifs aux risques du feu –
Partie 11-3:
Flammes d'essai – Flammes de 500 W –
Appareillage et méthodes d'essai de vérification
Fire hazard testing –
Part 11-3:
Test flames – 500 W flames –
Apparatus and confirmational test methods
IEC 2000 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
XA
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – TS 60695-11-3 © CEI:2000
SOMMAIRE
Pages
AVANT-PROPOS . 6
INTRODUCTION . 10
Articles
1 Domaine d'application. 14
2 Références normatives . 14
3 Définitions . 16
4 Méthode A . 16
5 Méthode B . 22
6 Méthode C. 28
7 Méthode D. 34
8 Dispositions préconisées pour l'utilisation des flammes d'essai. 40
9 Classification et désignation . 42
Annexe A (informative) Dispositions d'essai pour la méthode A. 48
Annexe B (informative) Disposition d'essai pour la méthode B. 56
Annexe C (normative) Disposition d'essai pour la méthode C . 70
Annexe D (normative) Disposition d'essai pour la méthode D . 82
Annexe E (informative) Exemples de dispositions d'essai pour essais sur matériel. 100
Annexe F (informative) Exemples de dispositions d'essai pour essais
sur bandes et feuilles de matériau. 102
Figure 1 – Bloc de cuivre. 44
Figure 2 – Calibre de hauteur de flamme. 46
Figure A.1 – Assemblage général et détails. 48
Figure A.2 – Disposition de l'alimentation du brûleur . 52
Figure A.3 – Disposition de l'essai de vérification. 54
Figure B.1 – Montage général . 56
Figure B.2 – Détails du brûleur de type à prémélange . 58
Figure B.3 – Détails du brûleur à prémélange. 60
Figure B.4 – Détails du brûleur à prémélange. 62
Figure B.5 – Détails du brûleur à prémélange. 64
Figure B.6 – Montage d'alimentation du brûleur. 66
Figure B.7 – Disposition de l'essai de vérification. 68
Figure C.1 – Brûleur, méthode C – Assemblage général. 70
Figure C.2 – Détails du brûleur – Fût du brûleur, joint torique, tubulaire d'air,
tube d'alimentation en air . 72
Figure C.3 – Détails du brûleur – Tube d’alimentation en gaz, injecteur gaz . 74
Figure C.4 – Détails du brûleur – Base du brûleur, bloc coude . 76
Figure C.5 – Disposition de l'alimentation du brûleur . 78
TS 60695-11-3 © IEC:2000 − 3 −
CONTENTS
Page
FOREWORD . 7
INTRODUCTION . 11
Clause
1 Scope . 15
2 Normative references. 15
3 Definitions. 17
4 Method A .17
5 Method B .23
6 Method C .29
7 Method D .35
8 Recommended arrangements for the use of the test flames . 41
9 Classification and designation. 43
Annex A (informative) Test method A arrangement. 49
Annex B (informative) Test method B arrangement. 57
Annex C (normative) Test method C arrangement . 71
Annex D (normative) Test method D arrangement . 83
Annex E (informative) Examples of test arrangements for tests on equipment . 101
Annex F (informative) Examples of test arrangements for tests on equipment . 103
Figure 1 – Copper block . 45
Figure 2 – Flame height gauge . 47
Figure A.1 – General assembly and details . 49
Figure A.2 – Burner supply arrangement . 53
Figure A.3 – Confirmatory test arrangement . 55
Figure B.1 – General assembly . 57
Figure B.2 – Pre-mixed burner details . 59
Figure B.3 – Pre-mixed burner details . 61
Figure B.4 – Pre-mixed burner details . 63
Figure B.5 – Pre-mixed burner details . 65
Figure B.6 – Burner/supply arrangement . 67
Figure B.7 – Confirmatory test arrangement . 69
Figure C.1 – Burner, method C – General assembly . 71
Figure C.2 – Burner details – Burner barrel, O-ring, air manifold and air supply tube. 73
Figure C.3 – Burner details – Gas supply tube and gas jet . 75
Figure C.4 – Burner details – Burner base and elbow block. 77
Figure C.5 – Burner supply arrangement . 79
– 4 – TS 60695-11-3 © CEI:2000
Pages
Figure C.6 – Disposition de l'essai de vérification. 80
Figure D.1 – Brûleur, méthode D – Assemblage général. 82
Figure D.2 – Détails du brûleur. 84
Figure D.3 – Détails du brûleur – Fût du brûleur . 86
Figure D.4 – Détails du brûleur – Injecteur gaz. 88
Figure D.5 – Détails du brûleur – Base du brûleur . 90
Figure D.6 – Détails du brûleur – Bloc coude. 92
Figure D.7 – Détails du brûleur – Embout cannelé. 94
Figure D.8 – Disposition de l'alimentation du brûleur . 96
Figure D.9 – Disposition de l'essai de vérification. 98
TS 60695-11-3 © IEC:2000 − 5 −
Page
Figure C.6 – Confirmatory test arrangement. 81
Figure D.1 – Burner, method D – General assembly . 83
Figure D.2 – Burner details. 85
Figure D.3 – Burner details – Burner barrel . 87
Figure D.4 – Burner details – Gas jet. 89
Figure D.5 – Burner details – Burner base. 91
Figure D.6 – Burner details – Elbow block . 93
Figure D.7 – Burner details – Barbed fitting. 95
Figure D.8 – Burner supply arrangement . 97
Figure D.9 – Confirmatory test arrangement. 99
– 6 – TS 60695-11-3 © CEI:2000
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
ESSAIS RELATIFS AUX RISQUES DU FEU –
Partie 11-3: Flammes d'essai – Flammes de 500 W –
Appareillage et méthodes d'essai de vérification
AVANT-PROPOS
1) La CEI (Commission Électrotechnique Internationale) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes
internationales. Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national
intéressé par le sujet traité peut participer. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement
avec l'Organisation Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les
deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, spécifications techniques, rapports techniques ou guides et agréés comme tels par les
Comités nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente spécification technique peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La tâche principale des comités d’études de la CEI est l’élaboration de Normes
internationales. Exceptionnellement, un comité d’études peut proposer la publication d’une
spécification technique
• lorsqu’en dépit de maints efforts, l’accord requis ne peut être réalisé en faveur de la
publication d’une Norme internationale, ou
• lorsque le sujet en question est encore en cours de développement technique ou quand,
pour une raison quelconque, la possibilité d’un accord pour la publication d’une Norme
internationale peut être envisagée pour l’avenir mais pas dans l’immédiat.
Les spécifications techniques font l’objet d’un nouvel examen trois ans au plus tard après leur
publication afin de décider éventuellement de leur transformation en Normes internationales.
La CEI 60695-11-3, qui est une spécification technique, a été établie par le comité d’études
89 de la CEI: Essais relatifs aux risques du feu.
La CEI 60695-11-3 remplace la CEI 60695-2-4/2 et constitue une révision technique. Elle est
à utiliser conjointement avec la CEI 60695-1-1 et la CEI 60695-4.
TS 60695-11-3 © IEC:2000 − 7 −
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FIRE HAZARD TESTING –
Part 11-3: Test flames – 500 W flames –
Apparatus and confirmational test methods
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International
Organization for Standardization (ISO) in accordance with conditions determined by agreement between the
two organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this technical specification may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
The main task of IEC technical committees is to prepare International Standards. In
exceptional circumstances, a technical committee may propose the publication of a technical
specification when
• the required support cannot be obtained for the publication of an International Standard,
despite repeated efforts, or
• the subject is still under technical development or where, for any other reason, there is the
future but no immediate possibility of an agreement on an International Standard.
Technical specifications are subject to review within three years of publication to decide
whether they can be transformed into International Standards.
IEC 60695-11-3, which is a technical specification, has been prepared by IEC technical
committee 89: Fire hazard testing.
IEC 60695-11-3 replaces IEC 60695-2-4/2 and constitutes a technical revision. It is to be used
in conjunction with IEC 60695-1-1 and IEC 60695-4.
– 8 – TS 60695-11-3 © CEI:2000
Le texte de cette spécification technique est issu des documents suivants:
Projet d’enquête Rapport de vote
89/308/CDV 89/340/RVC
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette spécification technique.
Elle a le statut de publication fondamentale de sécurité conformément au Guide 104 de la
CEI.
Cette publication a été rédigée selon les Directives ISO/CEI, Partie 3.
Les annexes C et D font partie intégrante de cette norme.
Les annexes A, B, E et F sont données uniquement à titre d'information.
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant 2005.
A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
TS 60695-11-3 © IEC:2000 − 9 −
The text of this technical specification is based on the following documents:
Enquiry draft Report on voting
89/308/CDV 89/340/RVC
Full information on the voting for the approval of this technical specification can be found in
the report on voting indicated in the above table.
It has the status of a basic safety publication in accordance with IEC Guide 104.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 3.
Annexes C and D form an integral part of this standard.
Annexes A, B, E and F are for information only.
The committee has decided that the contents of this publication will remain unchanged until
2005. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
– 10 – TS 60695-11-3 © CEI:2000
INTRODUCTION
La CEI 60695-11-3 fournit:
a) un guide sur la conception et l'utilisation des méthodes d'essai à la flamme pour évaluer
l'effet sur le spécimen de flammes provenant d'autres objets enflammés situés à
proximité, ou d'un feu au cours de sa phase initiale;
b) une description générale de l'appareillage requis pour produire la flamme d'essai;
c) une description générale du principe de la méthode de calibrage pour contrôler que la
flamme produite répond aux prescriptions.
La description détaillée de l'appareillage nécessaire pour produire et vérifier les flammes
d'essai est donnée dans une série de feuilles particulières, dont celle-ci.
Le statut de la série, actuellement à l'étude, est résumé dans le tableau suivant:
Flamme d'essai Type Gaz Statut présent Hauteur totale
apparente
mm
500 (A) Prémélange Méthane Méthode A de la Environ 125
presente spécification
technique
500 (B) Prémélange Propane Méthode B de la Environ 125
présente spécification
technique
500 (C) Prémélange Méthane/ Méthode C de la Environ 125
Propane présente spécification
technique
500 (D) Prémélange Méthane Méthode D de la Environ 125
présente spécification
technique
NOTE La CEI 60695-2-4/1 décrit l'appareillage et la méthode d'essai de vérification pour une flamme de
1 000 W (valeur nominale) et la CEI 60695-11-4 décrit les appareillages et les méthodes d'essai de
vérification pour une flamme de 50 W (valeur nominale).
Le but de ce travail, qui a été lancé par l'ACOS, est de mettre à la disposition de tous les
comités qui en ont besoin une série appropriée (minimale) de flammes d'essai normalisées,
couvrant une gamme de puissances. Chaque fois que possible, ces flammes d'essai ont été
basées sur des types existants, mais avec des spécifications améliorées.
Quatre méthodes (A, B, C et D) pour produire la flamme de 500 W (valeur nominale) ont été
développées et sont décrites dans la présente spécification technique. Les méthodes A et B
ont été publiées en 1994 et étaient fondées sur des matériels existants. Les méthodes C et D
sont fondées sur un matériel non réglable qui a été développé spécifiquement pour produire
des flammes d'essai très répétables et stables.
TS 60695-11-3 © IEC:2000 − 11 −
INTRODUCTION
IEC 60695-11-3 gives:
a) guidance on the design and use of flame test methods to assess the effect on the
specimen of flames such as may arise from other ignited items in the vicinity, or from a fire
in its early stages;
b) a general description of the apparatus required to produce the test flame;
c) a general description of the principle of a calibration procedure to check that the flame
produced meets the requirements.
The detailed description of the apparatus needed to produce and verify the test flames is
given in a series of sheets, of which this is one.
The status of the series, currently under study, is summarized in the following table:
Test flame Type Gas Present status Apparent overall
height
mm
500 (A) Pre-mixed Methane Method A of this Circa 125
technical specification
500 (B) Pre-mixed Propane Method B of this Circa 125
technical specification
500 (C) Pre-mixed Methane/ Method C of this Circa 125
propane technical specification
500 (D) Pre-mixed Methane Method D of this Circa 125
technical specification
NOTE IEC 60695-2-4/1 describes the apparatus and confirmational test method for a 1 000 W nominal test
flame and IEC 60695-11-4 describes the apparatus and confirmational test method for a 50 W nominal test
flame.
The aim of the work, which was initiated by ACOS, is to make available an appropriate
(minimum) series of standardized test flames, covering a range of powers for the use of all
committees needing test flames. Wherever possible these test flames have been based on
existing types, but with improved specifications.
Four methods A, B, C and D for producing the 500 W nominal test flame have been developed
and are described in this technical specification. Methods A and B were published in 1994
and were based on existing hardware. Methods C and D are based on non-adjustable
hardware that has been specifically developed to produce highly repeatable and stable test
flames.
– 12 – TS 60695-11-3 © CEI:2000
Les quatre flammes d'essai sont les suivantes:
– la flamme A, à base de méthane, utilise une version plus étroitement spécifiée d'un
brûleur qui a été utilisé dans certains pays pendant de nombreuses années;
– la flamme B, à base de propane, utilise le même matériel que décrit dans la CEI 60695-2-4/1
pour la flamme d'essai de 1 kW;
– la flamme C utilise une version plus sophistiquée du brûleur utilisé dans la méthode A et
peut être produite avec du méthane aussi bien qu'avec du propane;
– la flamme D, à base de méthane, utilise aussi une version plus sophistiquée du brûleur
utilisé dans la méthode A.
Les utilisateurs peuvent trouver que la flamme C est plus stable mais que le matériel utilisé
pour produire la flamme D est plus commode à manier.
TS 60695-11-3 © IEC:2000 − 13 −
The four test flames are as follows:
– flame A, based on methane, makes use of a more tightly specified version of a burner that
has been used in some countries for many years;
– flame B, based on propane, makes use of the same hardware as that described in
IEC 60695-2-4/1 for the 1 kW test flame;
– flame C, makes use of a more highly developed version of the burner that is used in
method A, and is capable of being produced using either methane or propane;
– flame D, based on methane, also makes use of a more highly developed version of the
burner that is used in method A.
Users may find that flame C is more stable but that the hardware used to produce flame D is
more convenient to handle.
– 14 – TS 60695-11-3 © CEI:2000
ESSAIS RELATIFS AUX RISQUES DU FEU –
Partie 11-3: Flammes d’essai – Flammes de 500 W –
Appareillage et méthodes d’essai de vérification
1 Domaine d'application
La présente spécification technique donne les prescriptions détaillées pour la production
d'une flamme d'essai de 500 W (valeur nominale), de type à prémélange. La hauteur totale
est de 125 mm approximativement.
Quatre méthodes sont décrites: les flammes A et D peuvent seulement être produites en
utilisant du méthane; la flamme B peut seulement être produite en utilisant du propane; la
flamme C peut être produite en utilisant soit du méthane soit du propane.
L’une des responsabilités d’un comité d’études consiste, le cas échéant, à utiliser les
publications fondamentales de sécurité dans le cadre de l’élaboration de ses publications.
2 Références normatives
Les documents normatifs suivants contiennent des dispositions qui, par suite de la référence
qui y est faite, constituent des dispositions valables pour la présente spécification technique.
Pour les références datées, les amendements ultérieurs ou les révisions de ces publications
ne s’appliquent pas. Toutefois, les parties prenantes aux accords fondés sur la présente
spécification technique sont invitées à rechercher la possibilité d'appliquer les éditions les
plus récentes des documents normatifs indiqués ci-après. Pour les références non datées, la
dernière édition du document normatif en référence s’applique. Les membres de la CEI et de
l'ISO possèdent le registre des Normes internationales en vigueur.
CEI Guide 104:1997, Elaboration des publications de sécurité et utilisation des publications
fondamentales de sécurité et publications groupées de sécurité
CEI 60584-1:1995, Couples thermoélectriques – Partie 1: Table de référence
CEI 60584-2:1982, Couples thermoélectriques – Deuxième partie: Tolérances
CEI 60695-1-1:1995, Essais relatifs aux risques du feu – Partie 1: Guide pour l’évaluation des
risques du feu des produits électrotechniques – Section 1: Guide général
CEI 60695-1-2:1982, Essais relatifs aux risques du feu – Première partie: Guide pour la
préparation des spécifications d'essai et des exigences pour l'estimation des risques du feu
des produits électrotechniques – Guide pour les composants électroniques
CEI 60695-1-3:1986, Essais relatifs aux risques du feu – Première partie: Guide pour la
préparation des spécifications d'essai et des exigences pour l'estimation des risques du feu
des produits électrotechniques – Guide pour l'utilisation des procédures de présélection
CEI 60695-2-4/0:1991, Essais relatifs aux risques du feu – Partie 2: Méthodes d'essai –
Section 4/feuille 0: Méthodes d'essai à la flamme de type à diffusion et de type à prémélange
CEI 60695-2-4/1:1991, Essais relatifs aux risques du feu – Partie 2: Méthodes d'essai –
Section 4/feuille 1: Flamme d'essai à prémélange de 1 kW nominal et guide
TS 60695-11-3 © IEC:2000 − 15 −
FIRE HAZARD TESTING –
Part 11-3: Test flames – 500 W flames –
Apparatus and confirmational test methods
1 Scope
This technical specification gives the detailed requirements for the production of a nominal
500 W, pre-mixed type test flame. The approximate overall height is 125 mm.
Four methods are given: flames A and D may only be produced using methane, flame B may
only be produced using propane and flame C may be produced using either methane or
propane.
One of the responsibilities of a technical committee is, wherever applicable, to make use of
basic safety publications in the preparation of its publications.
2 Normative references
The following normative documents contain provisions which, through reference in this text,
constitute provisions of this technical specification. For dated references, subsequent
amendments to, or revisions of, any of these publications do not apply. However, parties to
agreements based on this technical specification are encouraged to investigate the possibility
of applying the most recent editions of the normative documents indicated below. For undated
references, the latest edition of the normative document referred to applies. Members of IEC
and ISO maintain registers of currently valid International Standards.
IEC Guide 104:1997, The preparation of safety publications and the use of basic safety
publications and group safety publications
IEC 60584-1:1995, Thermocouples – Part 1: Reference tables
IEC 60584-2:1982, Thermocouples – Part 2: Tolerances
IEC 60695-1-1:1995, Fire hazard testing – Part 1: Guidance for assessing fire hazard of
electrotechnical products – Section 1: General guidance
IEC 60695-1-2:1982, Fire hazard testing – Part 1: Guidance for the preparation of
requirements and test specifications for assessing fire hazard of electrotechnical products –
Guidance for electronic components
IEC 60695-1-3:1986, Fire hazard testing – Part 1: Guidance for the preparation of
requirements and test specifications for assessing fire hazard of electrotechnical products –
Guidance for use of preselection procedures
IEC 60695-2-4/0:1991, Fire hazard testing – Part 2: Test methods – Section 4/sheet 0:
Diffusion type and premixed type flame test methods
IEC 60695-2-4/1:1991, Fire hazard testing – Part 2: Test methods – Section 4/sheet 1: 1 kW
nominal premixed test flame and guidance
– 16 – TS 60695-11-3 © CEI:2000
CEI 60695-4:1993, Essais relatifs aux risques du feu – Partie 4: Terminologie relative aux
essais au feu
ISO/CEI Guide 51:1990, Principes directeurs pour inclure dans les normes les aspects liés à
la sécurité
ISO 1337:1980, Cuivres corroyés (de teneur en cuivre minimale de 99,85 %) – Composition
chimique et forme des produits corroyés
3 Définitions
Pour les besoins de la présente spécification technique, la définition suivante s'applique:
3.1
flamme d'essai normalisée de 500 W (valeur nominale)
flamme qui est en conformité avec la présente spécification technique et qui remplit toutes les
exigences données à l'article 4 pour la méthode A, à l'article 5 pour la méthode B, à l'article 6
pour la méthode C, et à l'article 7 pour la méthode D
4 Méthode A
4.1 Prescriptions
Une flamme d'essai normalisée de 500 W (valeur nominale), conformément à cette méthode,
est celle produite:
– à l'aide du matériel conforme aux figures A.1 et A.2 (voir l'annexe A);
– avec une alimentation en gaz méthane d'une pureté supérieure ou égale à 98 % à un débit
*
équivalent à 965 ml/min ± 30 ml/min à 23 °C, sous 0,1 MPa , et sous une contre-pression
de 125 mm ± 5 mm d'eau, en utilisant la disposition de la figure A.2.
La flamme doit être symétrique, stable et donner un résultat de 54 s ± 2 s au cours de l'essai
de vérification décrit en 4.4.
La disposition de l'essai de vérification donnée à la figure A.3 doit être utilisée.
Les dimensions réelles de la flamme, mesurées dans la hotte de laboratoire/sorbonne, en
utilisant le calibre décrit à la figure 2, sont les suivantes :
– hauteur du cône bleu intérieur: 38 mm à 42 mm;
– hauteur totale: environ 125 mm.
4.2 Appareillage et gaz
4.2.1 Brûleur
Le brûleur doit être conforme à la figure A.1.
NOTE Le tube du brûleur, l'injecteur de gaz et la soupape à pointeau sont amovibles pour en permettre le
nettoyage. Il faut prendre soin lors du remontage que le sommet de la soupape à pointeau ne soit pas endommagé
et que la soupape à pointeau et le siège de la soupape (injecteur de gaz) soient correctement alignés.
__________
*
Corrigé à partir des mesures faites dans les conditions réelles d'utilisation.
TS 60695-11-3 © IEC:2000 − 17 −
IEC 60695-4:1993, Fire hazard testing – Part 4: Terminology concerning fire tests
ISO/IEC Guide 51:1990, Guidelines for the inclusion of safety aspects in standards
ISO 1337:1980, Wrought coppers (having minimum copper contents of 99,85 %) – Chemical
composition and forms of wrought products
3 Definitions
For the purpose of this technical specification, the following definition applies:
3.1
standardized 500 W test flame
flame that conforms with this technical specification and meets all of the requirements given
in clause 4 for method A, clause 5 for method B, clause 6 for method C and clause 7 for
method D
4 Method A
4.1 Requirements
A standardized 500 W nominal test flame, according to this method, is one that is produced:
– using hardware according to figures A.1 and A.2 (see annex A);
– supplied with methane gas of purity not less than 98 % at a flow rate equivalent to
*
965 ml/min ± 30 ml/min at 23 °C, 0,1 MPa , and at a back pressure of 125 mm ± 5 mm
water, using the arrangements of figure A.2.
The flame shall be symmetrical, stable and give a result of 54 s ± 2 s in the confirmatory test
described in 4.4.
The confirmatory test arrangement shown in figure A.3 shall be used.
The actual dimensions of the flame, when measured in the laboratory fumehood/chamber
using the gauge as described in figure 2, are as follows:
– blue inner cone height: 38 mm to 42 mm;
– overall height: approximately 125 mm.
4.2 Apparatus and fuel
4.2.1 Burner
The burner shall be in accordance with figure A.1.
NOTE The burner tube, gas injector and needle valve are removable for cleaning purposes. Care should be taken
on re-assembly that the needle valve tip is not damaged and that the needle valve and valve seat (gas injector) are
correctly aligned.
___________
*
When corrected from the measurements taken under actual conditions of use.
– 18 – TS 60695-11-3 © CEI:2000
4.2.2 Débitmètre
Le débitmètre doit être adapté à la mesure de débits de gaz de 965 ml/min à 23 °C, sous
0,1 MPa, avec une précision de ± 2%.
4.2.3 Manomètre
Le manomètre doit être adapté à la mesure de pressions dans la plage de 0 kPa à 7,5 kPa.
Un manomètre à eau peut être utilisé pour cet usage. Il convient qu'il soit adapté pour lire de
0 kPa à 7,5 kPa.
4.2.4 Vanne de commande
Une vanne de commande est nécessaire pour régler le débit de gaz dans les tolérances
prescrites.
4.2.5 Bloc de cuivre
Il doit avoir un diamètre de 9 mm, une masse de 10,00 g ± 0,05 g en l'état d'usinage complet
mais sans perçage (figure 1).
Il n'y a pas de méthode de vérification pour le bloc de cuivre. Les laboratoires sont
encouragés à maintenir une unité normalisée de référence, une unité normalisée secondaire
de référence et une unité de travail en les comparant par recoupement de façon appropriée
pour vérifier le fonctionnement du système.
4.2.6 Thermocouple
La température du bloc de cuivre doit être mesurée à l'aide d'un thermocouple de classe 1
(selon la CEI 60584-2), constitué de fils fins, à chemise métallique et à isolation minérale.
Il doit avoir un diamètre nominal total de 0,5 mm et des fils en NiCr et NiAl (type K)
(CEI 60584-1) par exemple, avec le point de soudure situé à l'intérieur de la gaine. La gaine
doit être faite d'un métal résistant à une température d'au moins 1 050 °C. Les tolérances sur
le thermocouple doivent être celles de la classe 1 de la CEI 60584-2.
1)
NOTE Une gaine faite d'un alliage à base de nickel résistant à la chaleur (tel que Inconel 600 ) satisfera aux
exigences ci-dessus.
La méthode préférentielle de fixation du thermocouple au bloc de cuivre est la méthode par
compression du cuivre autour du thermocouple, comme on le voit à la figure C.6.
4.2.7 Dispositifs d'indication ou d'enregistrement de température et de chronométrage
Les dispositifs doivent être adaptés pour la mesure du temps que met le bloc pour passer
d'une température de 100 °C ± 2 °C à 700 °C ± 3 °C, avec une incertitude de ± 0,5 s sur le
temps mesuré. Il doit avoir des moyens de mesure de la température et de la pression de
l'air ambiant.
4.2.8 Le gaz combustible doit être du méthane d'une pureté supérieure ou égale à 98 %.
__________
1)
Cette information est donnée à l'intension des utilisateurs de la présente spécification technique et ne signifie
nullement que la CEI approuve ou recommande l'emploi exclusif du produit ainsi désigné. Des produits
équivalents peuvent être utilisés s'il est démontré qu'ils conduisent aux mêmes résultats.
TS 60695-11-3 © IEC:2000 − 19 −
4.2.2 Flowmeter
The flowmeter shall be appropriate for the measurement of the gas flow rate of 965 ml/min at
23 °C, 0,1 MPa to an accuracy of ± 2 %.
4.2.3 Manometer
The manometer shall be appropriate for the measurement of pressure in the range of 0 kPa
to 7,5 kPa. A water manometer may be used for this purpose. It should be adapted to read
0 kPa to 7,5 kPa.
4.2.4 Control valve
A control valve is required to set the gas flow rate to within the required tolerances.
4.2.5 Copper block
A copper block of 9 mm diameter, of mass 10,00 g ± 0,05 g in the fully machined but undrilled
state (figure 1).
There is no verification method for the copper block. Laboratories are encouraged to maintain
a standard reference unit, a secondary standard reference unit and a working unit, cross-
comparing them as appropriate to verify the working system.
4.2.6 Thermocouple
A class 1 (IEC 60584-2) mineral insulated, metal sheathed fine-wire thermocouple with an
insulated junction, is used for measuring the tempe
...