IEC 61347-2-8:2000/AMD1:2006
(Amendment)Amendment 1 - Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps
Amendment 1 - Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps
The contents of the corrigendum of August 2012 have been included in this copy.
Amendement 1 - Appareillages de lampes - Partie 2-8: Prescriptions particulières pour les ballasts pour lampes fluorescentes
Le contenu du corrigendum d'août 2012 a été pris en considération dans cet exemplaire.
General Information
Relations
Standards Content (Sample)
NORME CEI
INTERNATIONALE
IEC
61347-2-8
INTERNATIONAL
STANDARD
AMENDEMENT 1
AMENDMENT 1
2006-01
Amendement 1
Appareillages de lampes –
Partie 2-8:
Prescriptions particulières pour les ballasts
pour lampes fluorescentes
Amendment 1
Lamp controlgear –
Part 2-8:
Particular requirements for ballasts
for fluorescent lamps
IEC 2006 Droits de reproduction réservés Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
E
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 61347-2-8 Amend. 1 © CEI:2006
AVANT-PROPOS
Le présent amendement a été établi par le sous-comité 34C Appareils auxiliaires pour
lampes, du comité d’études 34 de la CEI: Lampes et équipements associés.
Le texte de cet amendement est issu des documents suivants:
FDIS Rapport de vote
34C/708/FDIS 34C/716/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
Le comité a décidé que le contenu de cet amendement et de la publication de base ne sera
pas modifié avant la date de maintenance indiquée sur le site web de la CEI sous
"http://webstore.iec.ch" dans les données relatives à la publication recherchée. A cette date,
la publication sera
• reconduite,
• supprimée,
• remplacée par une édition révisée, ou
• amendée.
Le contenu du corrigendum d'août 2012 a été pris en considération dans cet exemplaire.
_____________
Page 2
SOMMAIRE
Ajouter le titre du nouvel Article 22:
22 Tension de sortie à vide
Ajouter à la liste des figures le titre de la nouvelle Figure I.1, comme suit :
Figure I.1 – Circuit d'essai pour appareillages magnétiques destinés aux lampes comportant
des dispositifs d'amorçage incorporés
Page 12
7.1 Marquages obligatoires
Remplacer, à la page 14, le premier tiret existant par ce qui suit:
– points a), b), e), f), g) et r) du 7.1 de la CEI 61347-1, conjointement avec
61347-2-8 Amend. 1 © IEC:2006 – 3 –
FOREWORD
This amendment has been prepared by subcommittee 34C: Auxiliaries for lamps, of IEC
technical committee 34: Lamps and related equipment.
The text of this amendment is based on the following documents:
FDIS Report on voting
34C/708/FDIS 34C/716/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
The contents of the corrigendum of August 2012 have been included in this copy.
___________
Page 3
CONTENTS
Add the title of the following new clause:
22 No-load output voltage
Add the title of the following new figure:
Figure I.1 – Test circuit for magnetic controlgear, for lamps with internal starting devices
Page 13
7.1 Mandatory markings
Replace, on page 15, the existing first indent with:
– items a), b), e), f), g) and r) of 7.1 of IEC 61347-1, together with
– 4 – 61347-2-8 Amend. 1 CEI:2006
Page 16
14.3 Essai d’échauffement des ballasts
Remplacer le premier alinéa par:
Lorsque le ballast est essayé dans les conditions définies dans l’Annexe H et suivant les
informations données dans l'Annexe J, les températures ne doivent pas dépasser les valeurs
figurant au Tableau 2 pour les essais en conditions normales et anormales (si applicable).
NOTE Les conditions anormales dans un circuit sont détaillées à l’Annexe D de la CEI 60598-1.
Page 18
Tableau 2 – Températures maximales
ère
Remplacer, dans la 1 colonne, « Eventuellement, condensateur voisin du boîtier du
ballast » par « Boîtier du ballast voisin du condensateur, s'il existe (incorporé dans
l'enveloppe du ballast) ».
Supprimer les NOTES 1 et 2 situées au bas du Tableau 2.
Insérer, immédiatement sous le Tableau 2, les deux alinéas suivants:
S'il est fait usage de matériaux ou de procédés de fabrication autres que ceux indiqués dans
ce tableau, il ne faut pas les soumettre en fonctionnement à des températures supérieures à
celles admissibles pour ces matériaux.
Il ne faut pas que les températures indiquées dans ce tableau soient dépassées lorsque le
ballast fonctionne à sa température ambiante maximale déclarée, le cas échéant. Il faut
considérer la température ambiante maximale pour un ballast, si elle n’est pas déclarée,
marquée et l’élévation de température de
comme la différence entre la température t
w
l’enroulement mesurée ∆t à 100 % de la tension assignée.
Page 22
Paragraphe 15.1
Dans le premier alinéa, ainsi que dans le deuxième et le cin
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.