Nominal dimensions of cylindrical machined graphite electrodes with threaded sockets and nipples for use in electric arc furnaces

Applies to turned and threaded cylindrical electrodes and to graphite nipples for arc furnaces.

Dimensions nominales des électrodes cylindriques tournées avec logements et nipples filetés en graphite pour les fours à arc

Est applicable aux électrodes cylindriques tournées et filetées et aux nipples en graphite pour les fours à arc.

General Information

Status
Published
Publication Date
27-Apr-1997
Current Stage
DELPUB - Deleted Publication
Start Date
22-Jun-2005
Completion Date
26-Oct-2025
Ref Project

Relations

Standard
IEC 60239:1997 - Nominal dimensions of cylindrical machined graphite electrodes with threaded sockets and nipples for use in electric arc furnaces Released:4/28/1997 Isbn:283183841X
English and French language
29 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NORME CEI
INTERNATIONALE
IEC
INTERNATIONAL
Troisième édition
STANDARD
Third edition
1997-05
Dimensions nominales des électrodes cylindriques
tournées avec logements et nipples filetés en
graphite pour les fours à arc
Nominal dimensions of cylindrical machined
graphite electrodes with threaded sockets
and nipples for use in electric arc furnaces

Numéro de référence
Reference number
CEI/IEC 60239: 1997
Validité de la présente publication Validity of this publication

Le contenu technique des publications de la CEI est cons- The technical content of IEC publications is kept under

tamment revu par la CEI afin qu'il reflète l'état actuel de constant review by the IEC, thus ensuring that the content

la technique. reflects current technology.

Des renseignements relatifs à la date de reconfirmation de la Information relating to the date of the reconfirmation of the

publication sont disponibles auprès du Bureau Central de la CEI. publication is available from the IEC Central Office.

Les renseignements relatifs à ces révisions, à l'établis- Information on the revision work, the issue of revised
sement des éditions révisées et aux amendements peuvent editions and amendments may be obtained from
être obtenus auprès des Comités nationaux de la CEI et IEC National Committees and from the following IEC

dans les documents ci-dessous: sources:

• Bulletin de la CEI • IEC Bulletin
• Annuaire de la CEI • IEC Yearbook
Publié annuellement Published yearly
• Catalogue des publications de la CEI • Catalogue of IEC publications
Publié annuellement et mis à jour régulièrement Published yearly with regular updates
Terminologie Terminology
En ce qui concerne la terminologie générale, le lecteur se For general terminology, readers are referred to IEC 60050:
reportera à la CEI 60050: Vocabulaire Electrotechnique International Electrotechnical Vocabulary (IEV), which is
International (VEI), qui se présente sous forme de chapitres issued in the form of separate chapters each dealing with a
séparés traitant chacun d'un sujet défini. Des détails specific field. Full details of the IEV will be supplied on
complets sur le VEI peuvent être obtenus sur demande. request. See also the IEC Multilingual Dictionary.
Voir également le dictionnaire multilingue de la CEI.
Les termes et définitions figurant dans la présente publi- The terms and definitions contained in the present publi-
cation ont été soit tirés du VEI, soit spécifiquement cation have either been taken from the IEV or have been
approuvés aux fins de cette publication. specifically approved for the purpose of this publication.
Symboles graphiques et littéraux Graphical and letter symbols
Pour les symboles graphiques, les symboles littéraux et les For graphical symbols, and letter symbols and signs
signes d'usage général approuvés par la CEI, le lecteur approved by the IEC for general use, readers are referred to
consultera: publications:
– la CEI 60027: Symboles littéraux à utiliser en – IEC 60027: Letter symbols to be used in
électrotechnique; electrical technology;
– la CEI 60417: Symboles graphiques utilisables – IEC 60417: Graphical symbols for use on
sur le matériel. Index, relevé et compilation des equipment. Index, survey and compilation of the
feuilles individuelles; single sheets;
– la CEI 60617: Symboles graphiques pour schémas; – IEC 60617: Graphical symbols for diagrams;
et pour les appareils électromédicaux, and for medical electrical equipment,

– la CEI 60878: Symboles graphiques pour – IEC 60878: Graphical symbols for electro-
équipements électriques en pratique médicale. medical equipment in medical practice.
Les symboles et signes contenus dans la présente publi- The symbols and signs contained in the present publication
cation ont été soit tirés de la CEI 60027, de la CEI 60417, have either been taken from IEC 60027, IEC 60417,
de la CEI 60617 et/ou de la CEI 60878, soit spécifiquement IEC 60617 and/or IEC 60878, or have been specifically
approuvés aux fins de cette publication. approved for the purpose of this publication.
Publications de la CEI établies par le IEC publications prepared by the same
même comité d'études technical committee
L'attention du lecteur est attirée sur les listes figurant à la fin The attention of readers is drawn to the end pages of this
de cette publication, qui énumèrent les publications de la publication which list the IEC publications issued by the
CEI préparées par le comité d'études qui a établi la technical committee which has prepared the present
présente publication. publication.

NORME
CEI
INTERNATIONALE
IEC
INTERNATIONAL
Troisième édition
STANDARD
Third edition
1997-05
Dimensions nominales des électrodes cylindriques
tournées avec logements et nipples filetés en
graphite pour les fours à arc
Nominal dimensions of cylindrical machined
graphite electrodes with threaded sockets
and nipples for use in electric arc furnaces

 IEC 1997 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni utilisée No part of this publication may be reproduced or utilized in
sous quelque forme que ce soit et par aucun procédé, électronique any form or by any means, electronic or mechanical, including
ou mécanique, y compris la photocopie et les microfilms, sans photocopying and microfilm, without permission in writing from
l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
PRICE CODE N
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 60239  CEI:1997
SOMMAIRE
Pages
AVANT-PROPOS. 4

Articles
1 Généralités. 6

1.1 Domaine d'application. 6

1.2 Objet. 6
1.3 Système d'unités de mesure. 6
2 Electrodes. 6
2.1 Diamètre des électrodes . 6
2.2 Longueur. 6
2.3 Logements filetés (dimensions) . 8
2.4 Dénomination.8
3 Nipples. 8
3.1 Dimensions . 8
3.2 Dénominations . 10
Tableaux. 10
Figures. 16
Annexe A – Electrodes mâles-femelles. 22

60239  IEC:1997 – 3 –
CONTENTS
Page
FOREWORD . 5

Clause
1 General . 7

1.1 Scope. 7

1.2 Object. 7
1.3 System of measurement. 7
2 Electrodes. 7
2.1 Diameter of electrodes. 7
2.2 Length . 7
2.3 Threaded socket (dimensions) . 9
2.4 Designation . 9
3 Nipples. 9
3.1 Dimensions . 9
3.2 Designations . 11
Tables. 11
Figures. 17
Annex A – Male-female electrodes. 23

– 4 – 60239  CEI:1997
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

_________
DIMENSIONS NOMINALES DES ÉLECTRODES CYLINDRIQUES

TOURNÉES AVEC LOGEMENTS ET NIPPLES FILETÉS EN GRAPHITE

POUR LES FOURS À ARC
AVANT-PROPOS
1) La CEI (Commission Electrotechnique Internationale) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes Internationales.
Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national intéressé par le
sujet traité peut participer. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement avec l'Organisation
Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques, représentent, dans la mesure
du possible un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, rapports techniques ou guides et agréés comme tels par les Comités nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 60239 a été établie par le comité d'études 27 de la CEI:
Chauffage électrique industriel.
Cette troisième édition annule et remplace la deuxième édition parue en 1987 et constitue une
révision technique.
Cette édition révisée contient toutes les modifications de la deuxième édition de la CEI 60239
décrites dans le document d'harmonisation HD 564 S1 du CENELEC.

Ces modifications incluent les nipples longs et les électrodes mâles-femelles.
Le texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
27/182/FDIS 27/192/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
L'annexe A est donnée uniquement à titre d'information.

60239  IEC:1997 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION

_________
NOMINAL DIMENSIONS OF CYLINDRICAL MACHINED GRAPHITE

ELECTRODES WITH THREADED SOCKETS AND NIPPLES

FOR USE IN ELECTRIC ARC FURNACES

FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical reports or guides and they are accepted by the National Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60239 has been prepared by IEC technical committee 27: Industrial
electroheating equipment.
This third edition cancels and replaces the second edition published in 1987 and constitutes a
technical revision.
This revised edition includes all modifications to IEC 60239, second edition, which are
described in the CENELEC harmonization document HD 564 S1.

These modifications include long nipples and male-female electrodes.
The text of this standard is based on the following documents:
FDIS Report on voting
27/182/FDIS 27/192/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
Annex A is for information only.

– 6 – 60239  CEI:1997
DIMENSIONS NOMINALES DES ÉLECTRODES CYLINDRIQUES

TOURNÉES AVEC LOGEMENTS ET NIPPLES FILETÉS EN GRAPHITE

POUR LES FOURS À ARC
1 Généralités
1.1 Domaine d'application
La présente norme s'applique aux électrodes de graphite cylindriques tournées avec logements
filetés et aux nipples en graphite employés sur les fours à arc sous la forme de colonnes de

graphite.
1.2 Objet
La présente norme s'applique aux:
– dimensions et tolérances sur la longueur et le diamètre des électrodes en graphite;
– dimensions et filetages des logements des électrodes en graphite et des nipples de
graphite de forme biconique utilisés avec ces électrodes.
La normalisation de ces caractéristiques dimensionnelles est essentielle pour assurer
l'interchangeabilité entre électrodes d'origines différentes, et représente le minimum
nécessaire.
NOTE – Cette normalisation permet de garantir que toute électrode à froid peut recevoir tout nipple de
dimensions appropriées.
Néanmoins la diversité des matières premières et des techniques de fabrication peut entraîner des
comportements thermiques différents des produits finis. Il n'est donc pas recommandé de mélanger des
électrodes et des nipples d'origines différentes.
1.3 Système d'unités de mesure
Le système métrique a été adopté pour la spécification des dimensions nominales.
NOTES
1 Pour la désignation des diamètres d'électrodes, les dimensions utilisées dans ce système de désignation
correspondent à une conversion approchée des pouces en millimètres. Le diamètre réel est en millimètres.
2 Les diamètres et longueurs des nipples sont exprimés en millimètres. Le nombre des décimales a été
volontairement limité à deux.
2 Electrodes
2.1 Diamètre des électrodes
Les diamètres nominaux des électrodes, avec les tolérances correspondantes, sont indiqués
dans le tableau 1. Les électrodes de graphite sont tournées pour obtenir le diamètre voulu sur
toute leur longueur.
Il peut arriver qu'une partie de la surface ne soit pas touchée par l'outil pendant le tournage.
Cette partie est appelée un «point bas».
Pour une électrode tournée de diamètre réel D comportant un point bas, la cote B (figure 1) ne
doit pas être inférieure aux valeurs indiquées dans le tableau 1.
2.2 Longueur
Les longueurs des électrodes (sans nipple) sont indiquées dans le tableau 1 et les tolérances
correspondantes dans le tableau 2.

60239  IEC:1997 – 7 –
NOMINAL DIMENSIONS OF CYLINDRICAL MACHINED GRAPHITE

ELECTRODES WITH THREADED SOCKETS AND NIPPLES

FOR USE IN ELECTRIC ARC FURNACES

1 General
1.1 Scope
This standard applies to turned and threaded cylindrical graphite electrodes and to graphite

nipples for use as full graphite columns on arc furnaces.
1.2 Object
This standard covers:
– the dimensions and tolerances on length and diameter of graphite electrodes;
– the dimensions and thread details for graphite electrode sockets and graphite nipples of
tapered shape, used with the graphite electrodes.
The standardization of the above dimensional features is essential for the interchangeability of
electrodes from different sources, and is a minimum standard.
NOTE – The standardization ensures that any electrode when cold can accept any nipple of appropriate
dimensions.
However, the variety of raw material and production techniques may lead to different thermal behaviour of
finished products. It is, therefore, not recommended that electrodes and nipples from different sources should
be mixed in use.
1.3 System of measurement
The metric system is adopted as the standard of measurement.
NOTES
1 The currently used nominal diameter is the designation diameter resulting from an approximate conversion
of former inches into millimetres. The real diameter is in millimetres.
2 The diameters and lengths of nipples are expressed in millimetres. The use of decimals has been
deliberately limited to two digits after the decimal point.
2 Electrodes
2.1 Diameter of electrodes
The nominal electrode diameters, together with the tolerances, are specified in table 1.
Graphite electrodes are machined in order to obtain the desired diameter over the whole
electrode length.
It may happen that part of the surface remains untouched by the tool when machining the
electrode. This part is called a "low spot".
For a turned electrode with actual diameter D having a low spot, the measurement B (figure 1)
shall be not less than the value given in table 1.
2.2 Length
The length of the electrodes (without nipple) is specified in table 1, and the length tolerances in
table 2.
– 8 – 60239  CEI:1997
2.3 Logements filetés (dimensions)

Deux types de filetages peuvent être utilisés:

– un filetage avec 4 filets par pouce (25,4 mm) pour les électrodes d’un diamètre nominal

de 75 mm à 700 mm, désigné T4;

– un filetage avec 3 filets par pouce (25,4 mm) pour les électrodes d’un diamètre nominal

de 225 mm à 550 mm inclus, désigné T3.

Il est possible d'utiliser pour les logements filetés T4 deux profondeurs différentes associées à
deux longueurs différentes de nipples pour les électrodes d’un diamètre nominal de 400 mm

à 700 mm.
Les dimensions des logements filetés des électrodes de graphite sont indiquées à la figure 2 et
au tableau 3 pour les logements T4 à 4 filets par pouce (25,4 mm).
Les dimensions des logements filetés des électrodes des graphite sont indiquées à la figure 2
et au tableau 4 pour les logements T3 à 3 filets par pouce (25,4 mm).
2.4
Dénomination
2.4.1 Les logements filetés sont désignés par la lettre «S» (socket), le diamètre nominal du
nipple correspondant, la lettre «T» pour le filetage conique, le nombre de filets par pouce
(25,4 mm), la lettre «N» pour les logements associés aux nipples courts, la lettre «L» pour les
logements associés aux nipples longs.
Exemples pour logements avec nipples courts:
S 317 T4N
S 273 T3N
Exemple pour logements avec nipples longs:
S 317 T4L
2.4.2 Les électrodes sont désignées par le diamètre nominal, la longueur nominale et la
dénomination du logement fileté.
Exemples pour électrodes avec nipples courts:
600 × 2100 × S 317 T4N
500 × 1800 × S 273 T3N
Exemple pour électrodes avec nipples longs:
600 × 2100 × S 317 T4 L
2.4.3 Des systèmes d'assemblage d'électrodes différents de ceux définis dans la présente
norme (c'est-à-dire sans nipples) peuvent être rencontrés dans certains pays. Il convient qu’ils
reçoivent une dénomination particulière comme cela est décrit dans l'annexe A.
3 Nipples
3.1 Dimensions
Le diamètre et la longueur du nipple correspondant au diamètre nominal extérieur d'une
électrode donnée sont indiqués par la figure 3 et le tableau 5 pour les filetages type T4, et par
la figure 4 et le tableau 6 pour les filetages type T3.

60239  IEC:1997 – 9 –
2.3 Threaded socket (dimensions)

Two types of thread can be used:

– those with 4 threads per 25,4 mm, (T4) for electrodes of nominal diameter 75 mm to 700 mm;

– those with 3 threads per 25,4 mm, (T3) for electrodes of nominal diameter 225 mm

to 550 mm.
Two different socket depths (related to two different nipple lengths) can be used for threaded

sockets T4 of electrodes of 400 mm to 700 mm nominal diameter.

The dimensions of threaded sockets of graphite electrodes are summarized in figure 2 and
table 3 for sockets with 4 threads per 25,4 mm (T4).
The dimensions of threaded sockets of graphite electrodes are shown in figure 2 and table 4
for sockets with 3 threads per 25,4 mm (T3).
2.4 Designation
2.4.1 Threaded sockets are designated by the letter "S" for socket, the nominal diameter of
the appropriate nipples, the letter "T" for taper thread, the number of threads per 25,4 mm and
the letter "N" or "L" for short or deep socket, respectively.
Examples for short socket:
S 317 T4N
S 273 T3N
Examples for deep socket:
S 317 T4L
2.4.2 Electrodes are designated by the nominal diameter, the nominal length and the symbol
for the threaded socket.
Examples for electrodes with short socket:
600 × 2100 × S 317 T4N
500 × 1800 × S 273 T3N
Example for electrodes with deep socket:
600 × 2100 × S 317 T4L
2.4.3 Connection systems for electrodes other than specified in this standard, that is without
nipples, are presently used in certain areas. They should have a different designation, as
shown in annex A.
3 Nipples
3.1 Dimensions
The diameter and length of the nipple, depending on the nominal outside diameter of the
appropriate electrode are shown in table 5 and figure 3, for thread type T4; and in table 6 and
figure 4, for thread type T3, respectively.

– 10 – 60239  CEI:1997
3.2 Dénominations
Les nipples sont désignés par la lettre «N» (nipple), la valeur nominale du grand diamètre, la

lettre «T» pour filetage biconique, le nombre de filets par pouce (25,4 mm), la lettre «N» pour

les nipples courts ou «L» pour les nipples longs.

Exemples pour nipples courts:
N 317 T4N
N 273 T3N
Exemple pour nipples longs:
N 317 T4L
Tableau 1 – Diamètres et longueurs des électrodes de graphite tournées et filetées
Tolérances sur le diamètre
Diamètre Diamètre Longueur
nominal nominal nominale
Maximum Minimum Point bas
mm mm mm mm mm mm
73 72 1 000/1 200/1 500
75 76 78
98 97 1 000/1 200/1 500
100 102 103
127 126 1 000/1 200/1 500
130 130 132
149 146 1 200/1 500/1 800
150 152 154
174 171 1 200/1 500/1 800
175 178 179
200 197 1 500/1 800
200 203 205
225 222 1 500/1 800
225 229 230
251 248 1 500/1 800
250 254 256
302 299 1 500/1 800/2 100
300 305 307
352 349 1 500/1 800/2 100
350 356 357
403 400 1 500/1 800/2 100
400 406 409
454 451 1 500/1 800/2 100/2 400
450 457 460
511 505 502 1 800/2 100/2 400
500 508
562 556 553 1 800/2 100/2 400
550 559
613 607 604 2 100/2 400/2 700
600 610
663 657 654 2 400/2 700
650 660
714 708 705 2 400/2 700
700 711
Tableau 2 – Tolérances sur la longueur des électrodes de graphite tournées et filetées
Tolérances sur électrodes normales Tolérances sur électrodes courtes
Longueur
nominale
Maximum Minimum Maximum Minimum
mm mm mm mm mm
1 000 +50 –75 –75 –200
1 200 +50 –100 –100 –225
1 500 +50 –100 –100 –275
1 800 +75 –100 –100 –275
2 100 +75 –125 –125 –275
2 400 +75 –125 –125 –275
2 700 +150 –150 –150 –300
NOTE – Le pourcentage admissible d'électrodes courtes par livraison doit être défini en accord
entre le fournisseur et l'utilisateur.

60239  IEC:1997 – 11 –
3.2 Designations
Nipples are designated by the letter "N" for nipple, the nominal major diameter, the letter "T" for

taper thread, the number of threads per 25,4 mm, and the letter "N" or "L" for short or long

nipple, respectively.
Examples for short nipples:
N 317 T4N
N 273 T3N
Example for long nipples:
N 317 T4L
Table 1 – Diameters and lengths of machined and threaded graphite electrodes
Diameter tolerances
Nominal Typical Nominal
diameter diameter length
Maximum Minimum Low spot
mm mm mm mm mm mm
73 72 1 000/1 200/1 500
75 76 78
98 97 1 000/1 200/1 500
100 102 103
127 126 1 000/1 200/1 500
130 130 132
149 146 1 200/1 500/1 800
150 152 154
174 171 1 200/1 500/1 800
175 178 179
200 197 1 500/1 800
200 203 205
225 222 1 500/1 800
225 229 230
251 248 1 500/1 800
250 254 256
302 299 1 500/1 800/2 100
300 305 307
352 349 1 500/1 800/2 100
350 356 357
403 400 1 500/1 800/2 100
400 406 409
454 451 1 500/1 800/2 100/2 400
450 457 460
511 505 502 1 800/2 100/2 400
500 508
562 556 553 1 800/2 100/2 400
550 559
613 607 604 2 100/2 400/2 700
600 610
663 657 654 2 400/2 700
650 660
714 708 705 2 400/2 700
700 711
Table 2 – Length tolerances of machined and threaded graphite electrodes
Length tolerances on normal electrodes Length tolerances on short electrodes
Nominal
length
Maximum Minimum Maximum Minimum
mm mm mm mm mm
1 000 +50 –75 –75 –200
1 200 +50 –100 –100 –225
1 500 +50 –100 –100 –275
1 800 +75 –100 –100 –275
2 100 +75 –125 –125 –
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...