IEC 60335-2-24:1997/AMD1:1998
(Amendment)Amendment 1 - Safety of household and similar electrical appliances - Part 2: Particular requirements for refrigerating appliances and ice-makers
Amendment 1 - Safety of household and similar electrical appliances - Part 2: Particular requirements for refrigerating appliances and ice-makers
Deals with compression-type appliances which use flammable refrigerants.
Amendement 1 - Sécurité des appareils électrodomestiques et analogues - Partie 2: Règles particulières pour les appareils de réfrigération et les fabriques de glace
Traite des appareils à compression qui utilissent des fluides frigorigènes inflammables.
General Information
Relations
Buy Standard
Standards Content (Sample)
NORME CEI
INTERNATIONALE
IEC
60335-2-24
INTERNATIONAL
STANDARD
AMENDEMENT 1
AMENDMENT 1
1998-08
Amendement 1
Sécurité des appareils électrodomestiques
et analogues –
Partie 2-24:
Règles particulières pour les appareils
de réfrigération et les fabriques de glace
Amendment 1
Safety of household and similar
electrical appliances –
Part 2-24:
Particular requirements for refrigerating
appliances and ice-makers
IEC 1998 Droits de reproduction réservés Copyright - all rights reserved
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
L
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 60335-2-24 amend. 1 © CEI:1998
AVANT-PROPOS
Le présent amendement a été établi par le sous-comité 61C: Appareils domestiques de
réfrigération, du comité d'études 61 de la CEI: Sécurité des appareils électrodomestiques et
analogues.
Le texte de cet amendement est issu des documents suivants:
FDIS Rapport de vote
61C/135/FDIS 61C/143/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
___________
Page 8
1 Domaine d'application
Ajouter la nouvelle prescription suivante après le premier alinéa:
Elle traite également des appareils à compression pour usage électrodomestique et
analogue, qui utilisent des fluides frigorigènes inflammables.
Remplacer le second point de la note 1 par ce qui suit:
– dans de nombreux pays, des prescriptions supplémentaires sont spécifiées par les organismes nationaux de la
santé publique, les organismes nationaux pour la protection des travailleurs et les organismes nationaux pour le
transport.
Page 10
2 Définitions
Ajouter, après la définition 2.108, la nouvelle définition suivante:
2.109
fluide frigorigène inflammable
fluide frigorigène ayant une classification d'inflammabilité de classe 2 ou 3 conformément à la
publication ANSI/ASHRAE 34
NOTE – Pour les mélanges de fluides frigorigènes qui ont plus d'une classification d'inflammabilité, on prend, pour
les besoins de la présente définition, la classification la plus défavorable.
60335-2-24 amend. 1 © IEC:1998 – 3 –
FOREWORD
This amendment has been prepared by subcommittee 61C: Household appliances for
refrigeration, of IEC technical committee 61: Safety of household and similar electrical
appliances.
The text of this amendment is based on the following documents:
FDIS Report on voting
61C/135/FDIS 61C/143/RVD
Full information on the voting for the approval of this amendment can be found in the report on
voting indicated in the above table.
___________
Page 9
1 Scope
Add the following new requirement after the first paragraph:
It also deals with compression-type appliances for household and similar use, which use
flammable refrigerants.
Replace the second item of note 1 by the following:
–
in many countries additional requirements are specified by national health authorities, the national authorities
responsible for the protection of labour and the national authorities responsible for transportation.
Page 11
2 Definitions
Add, after definition 2.108, the following new definition:
2.109
flammable refrigerant
refrigerant with a flammability classification of class 2 or 3 according to ANSI/ASHRAE 34
NOTE – For refrigerant blends which have more than one flammability classification the most unfavourable
classification is taken for the purposes of this definition.
– 4 – 60335-2-24 amend. 1 © CEI:1998
Page 12
3 Prescriptions générales
Remplacer le texte existant de cet article par le nouveau texte suivant:
L’article de la partie 1 est applicable avec les exceptions suivantes:
Addition:
NOTE 101 – L’utilisation des fluides frigorigènes inflammables entraîne des risques supplémentaires qui ne sont
pas les mêmes qu’avec les appareils utilisants des fluides frigorigènes non inflammables.
La présente norme aborde les risques dus à l’inflammation des fuites de fluide frigorigène provoquée par les
sources potentielles d’inflammation associées à l’appareil.
Le risque dû à l’inflammation de la fuite de fluide frigorigène par une source potentielle extérieure d'inflammation
associée avec l’environnement dans lequel l’appareil est installé est compensé par une probabilité d'inflammation
faible.
4 Conditions générales d'essais
4.2 Ajouter le nouveau texte suivant avant la note:
Au minimum un échantillon supplémentaire spécialement préparé est exigé pour les essais de
22.107.
Remplacer la note existante par ce qui suit:
NOTE 1 – Des échantillons séparés de moto-compresseurs peuvent être nécessaires pour l’essai de 19.1
NOTE 2 – L’essai de 22.7 peut être effectué sur des échantillons séparés.
NOTE 3 – A cause de la nature dangereuse des essais de 22.107, 22.108 et 22.109, des précautions spéciales
peuvent être nécessaires pour effectuer ces essais.
Ajouter, à la page 14, le nouveau paragraphe suivant:
4.10 Addition:
Pour les essais de 22.107, 22.108 et 22.109, l'appareil est vide et est installé de la façon
décrite ci-dessous:
Les appareils encastrés sont installés conformément aux instructions d'installation.
Les autres appareils sont placés dans une enceinte d'essai, les parois enfermant l'appareil
aussi près que possible de ses côtés et du dessus de l'appareil, à moins que le fabricant
n'indique dans les instructions d'installation qu'une distance libre au mur et au plafond doit être
respectée, auquel cas cette distance est respectée pendant l'essai.
4.103 Les appareils à compression qui utilisent des fluides frigorigènes inflammables et
qui, conformément aux instructions du fabricant, peuvent être utilisés avec d'autres appareils
électriques placés à l'intérieur du compartiment destiné à la conservation des denrées, sont
essayés avec ces autres appareils électriques incorporés et fonctionnant comme en usage
normal.
NOTE – Comme exemples d'autres appareils électriques, on peut citer les fabriques de glace et les appareils
désodorisants.
60335-2-24 amend. 1 © IEC:1998 – 5 –
Page 13
3 General requirement
Replace the existing text of this clause by the following new text:
This clause of part 1 is applicable except as follows:
Addition:
NOTE 101 – The use of flammable refrigerants involves additional hazards which are not associated with
appliances using non-flammable refrigerants.
This standard addresses the hazards due to ignition of leaked flammable refrigerant by potential ignition sources
associated with the appliance.
The hazard due to ignition of leaked flammable refrigerant by an external potential ignition source associated with
the environment in which the appliance is installed is compensated by the low probability of ignition.
4 General conditions for the tests
4.2 Add the following new text before the note:
At least one additional specially prepared sample is required for the tests of 22.107.
Replace the existing note by the following:
NOTE 1 – Separate samples of the motor compressors may be needed for the tests of 19.1.
NOTE 2 – The test of 22.7 may be carried out on separate samples.
NOTE 3 – Due to the potentially hazardous nature of the tests of 22.107, 22.108 and 22.109, special precautions
may need to be taken when carrying out the tests.
Add, on page 15, the following new subclause:
4.10 Addition:
For the tests of 22.107, 22.108 and 22.109, the appliance is empty and installed as outlined
below:
Built-in appliances are installed in accordance with the instructions for installation.
Other appliances are placed in a test enclosure, the walls enclosing the appliance as near to all
its sides and the top of the appliance as possible, unless the manufacturer indicates in the
instructions for installation that a free distance shall be observed from the walls or the ceiling,
in which case this distance is observed during the test.
4.103 Compression-type appliances which use flammable refrigerants and which,
according to the instructions, may be used with other electrical appliances inside a food
storage compartment are tested with such recommended appliances incorporated and being
operated as in normal use.
NOTE – Examples of such electrical appliances are ice-cream makers and deodorizers.
– 6 – 60335-2-24 amend. 1 © CEI:1998
Page 14
7 Marquage et indications
Ajouter, à la page 16, le point suivant en tant que dernier point de l'énumération:
7.1
– Le nom chimique ou le numéro du fluide frigorigène du principal composant de l’agent
moussant de l’isolation.
Ajouter la note suivante:
NOTE 102 – Les numéros des fluides frigorigènes sont donnés par l’ISO 817.
Ajouter, après les prescriptions existantes, les nouvelles prescriptions suivantes:
Pour les systèmes de réfrigération à compression, l’appareil doit aussi comporter la masse
de fluide frigorigène pour chaque circuit séparé de fluides frigorigènes.
Les appareils à compression qui utilisent des fluides frigorigènes inflammables doivent
être dotés du symbole d'avertissement B.3.2 de l’ISO 3864.
Page 16
7.6 Addition:
La hauteur du triangle contenant le symbole B.3.2. de l’ISO 3864 doit être au moins de 15 mm.
7.12 Ajouter la nouvelle prescription suivante:
Pour les appareils à compression qui utilisent des fluides frigorigènes inflammables, les
instructions doivent aussi inclure les informations pour l'installation, le nettoyage, l'entretien et
le rebut.
Les instructions doivent aussi inclure en substance les mises en gardes ci-dessous:
MISE EN GARDE – Maintenir dégagées les ouvertures de ventilation dans l'enceinte de
l'appareil ou dans la structure d'encastrement.
MISE EN GARDE – Ne pas utiliser de dispositifs mécaniques ou autres moyens pour accélérer
le processus de dégivrage autres que ceux recommandés par le fabricant.
MISE EN GARDE – Ne pas endommager le circuit de réfrigération.
NOTE 103 – Cette mise en garde n'est applicable qu'aux appareils dont les circuits de réfrigération sont
accessibles à l'utilisateur.
MISE EN GARDE – Ne pas utiliser d'appareils électriques à l'intérieur du compartiment destiné
à la conservation des denrées, à moins qu'ils ne soient du type recommandé par le fabricant.
Pour les appareils qui utilisent des agents moussants inflammables, les instructions doivent
inclure des informations relatives au rebut de l'appareil.
60335-2-24 amend. 1 © IEC:1998 – 7 –
Page 15
7 Marking and instructions
Add, on page 17, the following item as the last item of the enumeration:
7.1
– the chemical name or refrigerant number of the principal component of the insulation
blowing gas.
Add the following note:
NOTE 102 – Refrigerant numbers are given in ISO 817.
Add, after the existing requirements, the following new requirement:
For compression-type refrigerating systems, the appliance shall also be marked with the
mass of the refrigerant for each separate refrigerant circuit.
Compression-type appliances which use flammable refrigerants shall be marked with
warning sign B.3.2 from ISO 3864.
Page 17
7.6 Addition:
The perpendicular height of the triangle containing the warning sign B.3.2 from ISO 3864 shall
be at least 15 mm.
Add the following new requirement:
7.12
For compression-type appliances which use flammable refrigerants, the instructions shall
include information pertaining to the installation, handling, servicing and disposal of the
appliance.
The instructions shall also include the substance of the warnings listed below:
WARNING – Keep ventilation openings, in the appliance enclosure or in the built-in structure,
clear of obstruction.
WARNING – Do not use mechanical devices or other means to accelerate the defrosting
process, other than those recommended by the manufacturer.
WARNING – Do not damage the refrigerant circuit.
NOTE 103 – This warning is only applicable to appliances with refrigerating circuits which are accessible to the
user.
WARNING – Do not use electrical appliances inside the food storage compartments of the
appliance, unless they are of the type recommended by the manufacturer.
For appliances which use flammable insulation blowing gases, the instructions shall include
information regarding disposal of the appliance.
– 8 – 60335-2-24 amend. 1 © CEI:1998
Page 18
7.15 Ajouter la nouvelle prescription suivante:
Pour les appareils à compression, le marquage du type de fluide frigorigène inflammable
et de l'agent moussant inflammable, aussi bien que le symbole B.3.2 de l’ISO 3864, doivent
être visibles lorsqu'on accède aux moto-compresseurs.
Pour les autres appareils, le marquage du type d'agent moussant inflammable doit être sur
l'enveloppe extérieure.
Page 38
22 Construction
Remplacer le texte existant du paragraphe 22.7 par ce qui suit:
22.7 Remplacement:
Les appareils à compression, y compris les enveloppes de protection d'un système de
refroidissement protégé utilisant des fluides frigorigènes inflammables doivent résister à
– une pression égale à 3,5 fois la pression de vapeur saturante du fluide frigorigène à 70 °C
pour les parties situées du côté haute pression en fonctionnement normal;
– une pression égale à 5 fois la pression de vapeur saturante du fluide frigorigène à 20 °C
pour les parties situées uniquement du côté basse pression en fonctionnement normal.
NOTE 1 – Des prescriptions spécifiques de construction des appareils avec un système de refroidissement protégé
sont données en 22.107.
NOTE 2 – Toutes les pressions sont des pressions relatives.
La vérification est effectuée par l'essai suivant:
La partie appropriée de l'appareil en essai est soumise à une pression hydraulique qui est
augmentée progressivement jusqu'à ce que la pression d'essai prescrite soit atteinte. Cette
pression est maintenue pendant 1 min. Il ne doit se produire aucune fuite sur la partie en essai.
NOTE 3 – L'essai n'est pas effectué sur les moto-compresseurs conformes à la CEI 60335-2-34.
Page 42
Remplacer le texte existant du paragraphe 22.106 par ce qui suit:
22.106 La masse de fluide frigorigène des appareils à compression qui utilisent des fluides
frigorigènes inflammables dans leur système de réfrigération ne doit pas dépasser 150 g par
circuit de réfrigération individuel.
La vérification est effectuée par examen.
Ajouter, après le paragraphe 22.106, les nouveaux paragraphes suivants:
22.107 Les appareils à compression à systè
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.