Glassware — Hydrolytic resistance of the interior surfaces of glass containers — Part 2: Determination by flame spectrometry and classification

This document specifies: a) a method for determining the hydrolytic resistance of the interior surfaces of glass containers when subjected to attack by water at (121 ± 1) °C for (60 ± 1) min. The resistance is measured by determining the amount of sodium and other alkali metal or alkaline earth oxides in the extraction solution using flame atomic emission or absorption spectrometry (flame spectrometry); b) a classification of glass containers according to the hydrolytic resistance of the interior surfaces determined by the methods specified in this document. The test method specified in this document might not be applicable to containers whose surfaces have been treated for functional modifications, e.g. silicone (e.g. containers that are ready for direct filling).

Verrerie — Résistance hydrolytique des surfaces internes des récipients en verre — Partie 2: Détermination par spectrométrie de flamme et classification

Le présent document spécifie: a) une méthode de détermination de la résistance hydrolytique des surfaces internes des récipients en verre lorsqu’ils sont soumis à l’attaque de l’eau à (121 ± 1) °C durant (60 ± 1) min. La résistance hydrolytique est mesurée par détermination de la quantité d’oxyde de sodium et d’autres d’oxydes métalliques alcalins ou alcalino-terreux dans la solution d’extraction par spectrométrie d’absorption ou d’émission atomique de flamme (spectrométrie de flamme); b) une classification des récipients en verre selon la résistance hydrolytique des surfaces internes déterminée par la méthode spécifiée dans le présent document. La méthode d’essai spécifiée dans le présent document peut ne pas être applicable aux récipients dont les surfaces ont été traitées pour des modifications fonctionnelles, comme le silicone (les récipients prêts pour le remplissage direct, par exemple).

General Information

Status
Published
Publication Date
03-Dec-2023
Current Stage
6060 - International Standard published
Start Date
04-Dec-2023
Due Date
26-Nov-2024
Completion Date
04-Dec-2023
Ref Project

Relations

Buy Standard

Standard
ISO 4802-2:2023 - Glassware — Hydrolytic resistance of the interior surfaces of glass containers — Part 2: Determination by flame spectrometry and classification Released:4. 12. 2023
English language
15 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


INTERNATIONAL ISO
STANDARD 4802-2
Fourth edition
2023-12
Glassware — Hydrolytic resistance
of the interior surfaces of glass
containers —
Part 2:
Determination by flame spectrometry
and classification
Verrerie — Résistance hydrolytique des surfaces internes des
récipients en verre —
Partie 2: Détermination par spectrométrie de flamme et classification
Reference number
© ISO 2023
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 4
5 Reagents . 4
6 Apparatus . 6
7 Sample preparation .7
7.1 Sample size . 7
7.2 Determination of the filling volume . 7
7.2.1 Flat-bottomed containers ≤20 mm outer flange diameter (except ampoules,
syringes and cartridges) . 7
7.2.2 Flat-bottomed containers >20 mm outer flange diameter. 7
7.2.3 Round-bottomed containers . 8
7.2.4 Lipped containers . 8
7.2.5 Ampoules. 8
7.2.6 Syringes and cartridges . 8
8 Procedure .9
8.1 General . 9
8.2 Cleaning of samples . 9
8.3 Filling and heating . 9
8.4 Analysis of the extraction solutions . 10
8.4.1 Containers of hydrolytic resistance container classes HC 1, HC 2 and
F F
HC B or those known to be made from borosilicate glass . 10
F
8.4.2 Containers of hydrolytic resistance container classes HC 3 and HC D, or
F F
those known to be made from soda-lime-silica glass. 10
8.5 Test to determine whether the containers have been surface-treated. 11
9 Expression of results .12
9.1 Determination . 12
9.2 Classification .12
9.3 Distinction between containers of hydrolytic resistance container class HC 1 and
F
hydrolytic resistance container class HC 2 . 13
F
9.4 Designation . 13
10 Test report .13
11 Reproducibility .13
Bibliography .15
iii
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO document should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use
of (a) patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed
patent rights in respect thereof. As of the date of publication of this document, ISO had not received
notice of (a) patent(s) which may be required to implement this document. However, implementers are
cautioned that this may not represent the latest information, which may be obtained from the patent
database available at www.iso.org/patents. ISO shall not be held responsible for identifying any or all
such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to
the World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see
www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 76, Transfusion, infusion and injection, and
blood processing equipment for medical and pharmaceutical use.
This fourth edition cancels and replaces the third edition (ISO 4802-2:2016), which has been technically
revised.
The main changes are as follows:
— the explanation of the hydrolytic classes HC 1, HC 2, HC 3, HC B, HC D for different glass types;
F F F F F
— clarification of needed properties of purified water and test water;
— harmonization of the samples cleaning and the autoclavation process with Ph.Eur.;
— including containers up to 0,5 ml filling volume.
A list of all parts in the ISO 4802 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.
iv
Introduction
This document is largely based on a test method approved by the International Commission on Glass
(ICG), Technical Committee 2, Chemical Durability and Analysis, for measuring the hydrolytic resistance
of the interior surfaces of glass containers.
This document contains a classification which is related to but not equivalent to the classification set up
in ISO 4802-1 for the titration method.
The hydrolytic resistance of the inner glass surface is evaluated by determination of the released
alkali reacting ions. According to their hydrolytic resistance, glass containers are classified in defined
categories.
HC 1 glass containers are suitable for most preparations whether or not for parenteral administration.
F
HC 2 glass containers are suitable for most acidic and neutral, aqueous preparations whether or not for
F
parenteral administration.
HC 3 glass containers are in general suitable for non-aqueous preparations for parenteral
F
administration, for powders for parenteral administration (except for freeze-dried preparations) and
for preparations not for parenteral administration.
HC B glass containers are in general suitable for drinking ampoules (Container Class HGB 2 according
F
to ISO 719).
HC D glass containers are in general suitable for lower demands on hydrolytic resistance (Container
F
Class HGB 4 and HGB 5 according to ISO 719).
v
INTERNATIONAL STANDARD ISO 4802-2:2023(E)
Glassware — Hydrolytic resistance of the interior surfaces
of glass containers —
Part 2:
Determination by flame spectrometry and classification
1 Scope
This document specifies:
a) a method for determining the hydrolytic resistance of the interior surfaces of glass containers
when subjected to attack by water at (121 ± 1) °C for (60 ± 1) min. The resistance is measured by
determining the amount of sodium and other alkali metal or alkaline earth oxides in the extraction
solution using flame atomic emission or absorption spectrometry (flame spectrometry);
b) a classification of glass containers according to the hydrolytic resistance of the interior surfaces
determined by the methods specified in this document.
The test method specified in this document might not be applicable to containers whose surfaces have
been treated for functional modifications, e.g. silicone (e.g. containers that are ready for direct filling).
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 385, Laboratory glassware — Burettes
ISO 719, Glass — Hydrolytic resistance of glass grains at 98 °C — Method of test and classification
ISO 720, Glass — Hydrolytic resistance of glass grains at 121 °C — Method of test and classification
ISO 1042, Laboratory glassware — One-mark volumetric flasks
ISO 3819, Laboratory glassware — Beakers
ISO 9187-1, Injection equipment for medical use — Part 1: Ampoules for injectables
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
3.1
ampoule
small, normally flat-bo
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.