ISO 2470-1:2016
(Main)Paper, board and pulps — Measurement of diffuse blue reflectance factor — Part 1: Indoor daylight conditions (ISO brightness)
Paper, board and pulps — Measurement of diffuse blue reflectance factor — Part 1: Indoor daylight conditions (ISO brightness)
ISO 2470-1:2016 specifies a method for measuring the diffuse blue reflectance factor (ISO brightness) of pulps, papers and boards. ISO 2470-1:2016 is limited in its scope to white and near-white pulps, papers and boards. The measurement can only be made in an instrument in which the ultraviolet energy level of the illumination has been adjusted to correspond to the CIE illuminant C[6] using a fluorescent reference standard. The CIE illuminant C is taken to be representative of indoor daylight conditions because it contains a suitable proportion of UV radiation.[9]
Papier, carton et pâtes — Mesurage du facteur de réflectance diffuse dans le bleu — Partie 1: Conditions d'éclairage intérieur de jour (degré de blancheur ISO)
ISO 2470-1:2016 spécifie une méthode de mesure du facteur de réflectance diffuse dans le bleu (degré de blancheur ISO) des pâtes, papiers et cartons. ISO 2470-1:2016 se limite aux pâtes, papiers et cartons blancs ou presque blancs. Le mesurage ne peut être effectué qu'à l'aide d'un appareil dans lequel le niveau d'énergie ultraviolette de l'éclairage a été réglé à l'aide d'un étalon de référence fluorescent pour correspondre à l'illuminant CIE C[6]. L'illuminant CIE C est défini comme étant représentatif des conditions de lumière du jour à l'intérieur parce qu'il contient une proportion appropriée de rayonnement UV[9].
Papir, karton in lepenka - Merjenje faktorja razpršene odsevnosti v modrem - 1. del: Pogoji osvetlitve v prostoru (belina po ISO)
Ta del standarda ISO 2470 določa metodo za merjenje faktorja razpršene odsevnosti v modrem (belina
po ISO) pri lepenki, papirju in kartonu.
Področje uporabe tega dela standarda ISO 2470 je lepenka, papir in karton bele ali skoraj bele barve. Meritev
se lahko izvede samo z instrumentom, v katerem je bila raven energije ultravijolične osvetlitve prilagojena tako, da ustreza vrsti svetlobe CIE C[6], pri čemer je treba uporabiti referenčni standard za fluorescenco.
Vrsta svetlobe CIE C je značilna za notranjo dnevno svetlobo, ker vsebuje primeren delež UV-sevanja.[9]
OPOMBA: Lastnost, imenovana svetlost D65, se meri z instrumentom, ki ustreza CIE-standardiziranem iluminantu D65[4], ki ima veliko večjo vsebnost žarkov UV, kot je določeno v tem delu standarda ISO 2470. Meritev svetlosti D65 je opisana v standardu ISO 2470-2.[2]
General Information
Relations
Buy Standard
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 2470-1
Second edition
2016-09-15
Paper, board and pulps —
Measurement of diffuse blue
reflectance factor —
Part 1:
Indoor daylight conditions (ISO
brightness)
Papier, carton et pâtes — Mesurage du facteur de réflectance diffuse
dans le bleu —
Partie 1: Conditions d’éclairage intérieur de jour (degré de
blancheur ISO)
Reference number
ISO 2470-1:2016(E)
©
ISO 2016
---------------------- Page: 1 ----------------------
ISO 2470-1:2016(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2016, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2016 – All rights reserved
---------------------- Page: 2 ----------------------
ISO 2470-1:2016(E)
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 2
5 Apparatus . 2
5.1 Reflectometer . 2
5.2 Reference standards for calibration of the instrument and the working standards . 3
5.3 Working standards . 3
6 Sampling and conditioning . 3
7 Preparation of test pieces . 3
8 Procedure. 4
9 Expression of results . 4
10 Test report . 4
Annex A (normative) Spectral characteristics of instruments for measuring ISO brightness .6
Annex B (normative) UV calibration service . 8
Annex C (informative) Precision .10
Bibliography .11
© ISO 2016 – All rights reserved iii
---------------------- Page: 3 ----------------------
ISO 2470-1:2016(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment,
as well as information about ISO’s adherence to the World Trade Organization (WTO) principles in the
Technical Barriers to Trade (TBT) see the following URL: www.iso.org/iso/foreword.html.
The committee responsible for this document is ISO/TC 6, Paper, board and pulps.
This second edition cancels and replaces the first edition (ISO 2470-1:2009), of which it constitutes a
minor revision including the following modifications:
— references in Clause 2 and in the Bibliography have been updated;
— the terminology (Clause 3) has been revised to be consistent with the information provided in
ISO/TR 10688 and, wherever possible, with the symbols used in the CIE International Lighting
Vocabulary;
— references to “ISO/TC 6 authorized laboratories” have been eliminated;
— the precision statement has been moved to an informative annex (Annex C).
ISO 2470 consists of the following parts, under the general title Paper, board and pulps — Measurement
of diffuse blue reflectance factor:
— Part 1: Indoor daylight conditions (ISO brightness)
— Part 2: Outdoor daylight conditions (D65 brightness)
iv © ISO 2016 – All rights reserved
---------------------- Page: 4 ----------------------
ISO 2470-1:2016(E)
Introduction
The diffuse reflectance factor (radiance factor) depends on the conditions of measurement, particularly
the spectral and geometric characteristics of the instrument used. This part of ISO 2470 is therefore
intended to be read in conjunction with ISO 2469 which defines the geometric characteristics of the
instrument and also defines the photometric calibration procedure to be adopted.
The definition of ISO brightness is historically linked to the Zeiss Elrepho instrument having, as a light
source, an incandescent lamp which excites fluorescence to only a limited extent. It is specified here
that, in instruments of the abridged spectrophotometer or filter colorimeter type, the UV content of
the illumination be adjusted to conform to the CIE illuminant C as defined by a fluorescent reference
standard having an assigned value of ISO brightness as described in Annex B. Only if this is done can
the property measured on a fluorescent material be called ISO brightness.
© ISO 2016 – All rights reserved v
---------------------- Page: 5 ----------------------
INTERNATIONAL STANDARD ISO 2470-1:2016(E)
Paper, board and pulps — Measurement of diffuse blue
reflectance factor —
Part 1:
Indoor daylight conditions (ISO brightness)
1 Scope
This part of ISO 2470 specifies a method for measuring the diffuse blue reflectance factor (ISO
brightness) of pulps, papers and boards.
This part of ISO 2470 is limited in its scope to white and near-white pulps, papers and boards. The
measurement can only be made in an instrument in which the ultraviolet energy level of the illumination
[6]
has been adjusted to correspond to the CIE illuminant C using a fluorescent reference standard.
The CIE illuminant C is taken to be representative of indoor daylight conditions because it contains a
[9]
suitable proportion of UV radiation.
NOTE The property called D65 brightness is measured with an instrument adjusted to correspond with CIE
[4]
standard illuminant D65, which has a much higher UV content than that specified in this part of ISO 2470. The
[2]
measurement of D65 brightness is described in ISO 2470-2.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 186, Paper and board — Sampling to determine average quality
ISO 2469, Paper, board and pulps — Measurement of diffuse radiance factor (diffuse reflectance factor)
ISO 3688, Pulps — Preparation of laboratory sheets for the measurement of diffuse blue reflectance factor
(ISO brightness)
ISO 4094, Paper, board and pulps — International calibration of testing apparatus — Nomination and
acceptance of standardizing and authorized laboratories
ISO 7213, Pulps — Sampling for testing
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
diffuse radiance factor
β
ratio of the diffusely reflected radiance of a body in a given direction to that of the perfect reflecting
diffuser under specified conditions of irradiation
Note 1 to entry: For fluorescent (luminescent) materials, the specified conditions of irradiation in this part of
ISO 2470 are CIE illuminant C and the diffuse radiance factor is strictly the total radiance factor, β, which is the
sum of two components, the reflected radiance factor, β , and the luminescent radiance factor, β , so that:
R L
β = β + β
R L
© ISO 2016 – All rights reserved 1
---------------------- Page: 6 ----------------------
ISO 2470-1:2016(E)
Note 2 to entry: For non-fluorescent materials, the diffuse radiance factor, β , is simply the diffuse reflectance
R
factor R.
3.2
diffuse reflectance factor
R
ratio of the radiation reflected and emitted from a body to that reflected from the perfect reflecting
diffuser under the same conditions of diffuse illumination and normal detection
Note 1 to entry: The ratio is often expressed as a percentage.
Note 2 to entry: The diffuse reflectance factor is influenced by the backing if the body is translucent.
Note 3 to entry: This part of ISO 2470 prescribes diffuse illumination and normal detection in an instrument
calibrated in accordance with the provisions of this part of ISO 2470.
3.3
intrinsic diffuse reflectance factor
R
∞
diffuse reflectance factor of a layer or pad of material thick enough to be opaque, i.e. such that increasing
the thickness of the pad by doubling the number of sheets results in no change in the measured radiance
[reflectance] factor
Note 1 to entry: The diffuse reflectance factor of a single non-opaque sheet is dependent on the background and
is not a material property.
3.4
ISO brightness
R
457
intrinsic diffuse radiance (reflectance) factor measured with a reflectometer having the characteristics
described in ISO 2469, equipped with a filter or corresponding function having an effective wavelength
of 457 nm and a half bandwidth of 44 nm, and adjusted so that the UV content of the irradiation incident
upon the test piece corresponds to that of the CIE illuminant C
Note 1 to entry: The filter function is described more fully by the weighting function factors given in Annex A and
Table A.1.
4 Principle
A test piece is illuminated diffusely in a standard instrument and the light reflected normal to the
surface is either allowed to pass through a defined optical filter and then measured by a photodetector
or measured by an array of photosensitive diodes, where each diode responds to a different effective
wavelength. The brightness is then determined directly from the output from the photodetector or by
calculation from the photosensitive diode outputs using the appropriate weighting function.
5 Apparatus
5.1 Reflectometer
5.1.1 Reflectometer having the geometric, spectral and photometric characteristics described
in ISO 2469 and calibrated in accordance with the provisions of ISO 2469, and equipped for the
measurement of blue reflectance factor as defined in Annex A.
5.1.2 In the case of a filter reflectometer, the radiation falling upon the test piece shall have a UV
content corresponding to that of the CIE illuminant C.
5.1.3 In the case of an abridged spectrophotometer, the instrument shall have an adjustable filter with
a cut-off wavelength of 395 nm or some other system for adjustment and control, and this filter shall be
2 © ISO 2016 – All rights reserved
---------------------- Page: 7 ----------------------
ISO 2470-1:2016(E)
adjusted or the system shall be calibrated with the help of the fluorescence reference standard (5.2.3), so
that the UV content of the illumination falling upon the sample corresponds to that of the CIE illuminant C.
5.2 Reference standards for calibration of the instrument and the working standards
5.2.1 Use reference standards sufficiently frequently to ensure satisfactory calibration and UV
adjustment.
NOTE This frequency interval can be fixed according to a defined schedule or control limits (e.g. from drift
analysis of the measuring instrument).
5.2.2 Non-fluorescent reference standard for photometric calibration, fulfilling the requirements
for international reference
...
SLOVENSKI STANDARD
oSIST ISO 2470-1:2017
01-marec-2017
Papir, karton in lepenka - Merjenje faktorja razpršene odsevnosti v modrem - 1.
del: Pogoji osvetlitve v prostoru (belina po ISO)
Paper, board and pulps -- Measurement of diffuse blue reflectance factor -- Part 1:
Indoor daylight conditions (ISO brightness)
Papier, carton et pâtes -- Mesurage du facteur de réflectance diffuse dans le bleu --
Partie 1: Conditions d'éclairage intérieur de jour (degré de blancheur ISO)
Ta slovenski standard je istoveten z: ISO 2470-1:2016
ICS:
85.040 Vlaknine Pulps
85.060 Papir, karton in lepenka Paper and board
oSIST ISO 2470-1:2017 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
oSIST ISO 2470-1:2017
---------------------- Page: 2 ----------------------
oSIST ISO 2470-1:2017
INTERNATIONAL ISO
STANDARD 2470-1
Second edition
2016-09-15
Paper, board and pulps —
Measurement of diffuse blue
reflectance factor —
Part 1:
Indoor daylight conditions (ISO
brightness)
Papier, carton et pâtes — Mesurage du facteur de réflectance diffuse
dans le bleu —
Partie 1: Conditions d’éclairage intérieur de jour (degré de
blancheur ISO)
Reference number
ISO 2470-1:2016(E)
©
ISO 2016
---------------------- Page: 3 ----------------------
oSIST ISO 2470-1:2017
ISO 2470-1:2016(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2016, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2016 – All rights reserved
---------------------- Page: 4 ----------------------
oSIST ISO 2470-1:2017
ISO 2470-1:2016(E)
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 2
5 Apparatus . 2
5.1 Reflectometer . 2
5.2 Reference standards for calibration of the instrument and the working standards . 3
5.3 Working standards . 3
6 Sampling and conditioning . 3
7 Preparation of test pieces . 3
8 Procedure. 4
9 Expression of results . 4
10 Test report . 4
Annex A (normative) Spectral characteristics of instruments for measuring ISO brightness .6
Annex B (normative) UV calibration service . 8
Annex C (informative) Precision .10
Bibliography .11
© ISO 2016 – All rights reserved iii
---------------------- Page: 5 ----------------------
oSIST ISO 2470-1:2017
ISO 2470-1:2016(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment,
as well as information about ISO’s adherence to the World Trade Organization (WTO) principles in the
Technical Barriers to Trade (TBT) see the following URL: www.iso.org/iso/foreword.html.
The committee responsible for this document is ISO/TC 6, Paper, board and pulps.
This second edition cancels and replaces the first edition (ISO 2470-1:2009), of which it constitutes a
minor revision including the following modifications:
— references in Clause 2 and in the Bibliography have been updated;
— the terminology (Clause 3) has been revised to be consistent with the information provided in
ISO/TR 10688 and, wherever possible, with the symbols used in the CIE International Lighting
Vocabulary;
— references to “ISO/TC 6 authorized laboratories” have been eliminated;
— the precision statement has been moved to an informative annex (Annex C).
ISO 2470 consists of the following parts, under the general title Paper, board and pulps — Measurement
of diffuse blue reflectance factor:
— Part 1: Indoor daylight conditions (ISO brightness)
— Part 2: Outdoor daylight conditions (D65 brightness)
iv © ISO 2016 – All rights reserved
---------------------- Page: 6 ----------------------
oSIST ISO 2470-1:2017
ISO 2470-1:2016(E)
Introduction
The diffuse reflectance factor (radiance factor) depends on the conditions of measurement, particularly
the spectral and geometric characteristics of the instrument used. This part of ISO 2470 is therefore
intended to be read in conjunction with ISO 2469 which defines the geometric characteristics of the
instrument and also defines the photometric calibration procedure to be adopted.
The definition of ISO brightness is historically linked to the Zeiss Elrepho instrument having, as a light
source, an incandescent lamp which excites fluorescence to only a limited extent. It is specified here
that, in instruments of the abridged spectrophotometer or filter colorimeter type, the UV content of
the illumination be adjusted to conform to the CIE illuminant C as defined by a fluorescent reference
standard having an assigned value of ISO brightness as described in Annex B. Only if this is done can
the property measured on a fluorescent material be called ISO brightness.
© ISO 2016 – All rights reserved v
---------------------- Page: 7 ----------------------
oSIST ISO 2470-1:2017
---------------------- Page: 8 ----------------------
oSIST ISO 2470-1:2017
INTERNATIONAL STANDARD ISO 2470-1:2016(E)
Paper, board and pulps — Measurement of diffuse blue
reflectance factor —
Part 1:
Indoor daylight conditions (ISO brightness)
1 Scope
This part of ISO 2470 specifies a method for measuring the diffuse blue reflectance factor (ISO
brightness) of pulps, papers and boards.
This part of ISO 2470 is limited in its scope to white and near-white pulps, papers and boards. The
measurement can only be made in an instrument in which the ultraviolet energy level of the illumination
[6]
has been adjusted to correspond to the CIE illuminant C using a fluorescent reference standard.
The CIE illuminant C is taken to be representative of indoor daylight conditions because it contains a
[9]
suitable proportion of UV radiation.
NOTE The property called D65 brightness is measured with an instrument adjusted to correspond with CIE
[4]
standard illuminant D65, which has a much higher UV content than that specified in this part of ISO 2470. The
[2]
measurement of D65 brightness is described in ISO 2470-2.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 186, Paper and board — Sampling to determine average quality
ISO 2469, Paper, board and pulps — Measurement of diffuse radiance factor (diffuse reflectance factor)
ISO 3688, Pulps — Preparation of laboratory sheets for the measurement of diffuse blue reflectance factor
(ISO brightness)
ISO 4094, Paper, board and pulps — International calibration of testing apparatus — Nomination and
acceptance of standardizing and authorized laboratories
ISO 7213, Pulps — Sampling for testing
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
diffuse radiance factor
β
ratio of the diffusely reflected radiance of a body in a given direction to that of the perfect reflecting
diffuser under specified conditions of irradiation
Note 1 to entry: For fluorescent (luminescent) materials, the specified conditions of irradiation in this part of
ISO 2470 are CIE illuminant C and the diffuse radiance factor is strictly the total radiance factor, β, which is the
sum of two components, the reflected radiance factor, β , and the luminescent radiance factor, β , so that:
R L
β = β + β
R L
© ISO 2016 – All rights reserved 1
---------------------- Page: 9 ----------------------
oSIST ISO 2470-1:2017
ISO 2470-1:2016(E)
Note 2 to entry: For non-fluorescent materials, the diffuse radiance factor, β , is simply the diffuse reflectance
R
factor R.
3.2
diffuse reflectance factor
R
ratio of the radiation reflected and emitted from a body to that reflected from the perfect reflecting
diffuser under the same conditions of diffuse illumination and normal detection
Note 1 to entry: The ratio is often expressed as a percentage.
Note 2 to entry: The diffuse reflectance factor is influenced by the backing if the body is translucent.
Note 3 to entry: This part of ISO 2470 prescribes diffuse illumination and normal detection in an instrument
calibrated in accordance with the provisions of this part of ISO 2470.
3.3
intrinsic diffuse reflectance factor
R
∞
diffuse reflectance factor of a layer or pad of material thick enough to be opaque, i.e. such that increasing
the thickness of the pad by doubling the number of sheets results in no change in the measured radiance
[reflectance] factor
Note 1 to entry: The diffuse reflectance factor of a single non-opaque sheet is dependent on the background and
is not a material property.
3.4
ISO brightness
R
457
intrinsic diffuse radiance (reflectance) factor measured with a reflectometer having the characteristics
described in ISO 2469, equipped with a filter or corresponding function having an effective wavelength
of 457 nm and a half bandwidth of 44 nm, and adjusted so that the UV content of the irradiation incident
upon the test piece corresponds to that of the CIE illuminant C
Note 1 to entry: The filter function is described more fully by the weighting function factors given in Annex A and
Table A.1.
4 Principle
A test piece is illuminated diffusely in a standard instrument and the light reflected normal to the
surface is either allowed to pass through a defined optical filter and then measured by a photodetector
or measured by an array of photosensitive diodes, where each diode responds to a different effective
wavelength. The brightness is then determined directly from the output from the photodetector or by
calculation from the photosensitive diode outputs using the appropriate weighting function.
5 Apparatus
5.1 Reflectometer
5.1.1 Reflectometer having the geometric, spectral and photometric characteristics described
in ISO 2469 and calibrated in accordance with the provisions of ISO 2469, and equipped for the
measurement of blue reflectance factor as defined in Annex A.
5.1.2 In the case of a filter reflectometer, the radiation falling upon the test piece shall have a UV
content corresponding to that of the CIE illuminant C.
5.1.3 In the case of an abridged spectrophotometer, the instrument shall have an adjustable filter with
a cut-off wavelength of 395 nm or some other system for adjustment and control, and this filter shall be
2 © ISO 2016 – All rights reserved
---------------------- Page: 10 ----------------------
oSIST ISO 2470-1:2017
ISO 2470-1:2016(E)
adjusted or the system shall be calibrated with the help of the fluorescence reference standard (5.2.3), so
that the UV content
...
SLOVENSKI STANDARD
SIST ISO 2470-1:2017
01-april-2017
1DGRPHãþD
SIST ISO 2470-1:2013
Papir, karton in lepenka - Merjenje faktorja razpršene odsevnosti v modrem - 1.
del: Pogoji osvetlitve v prostoru (belina po ISO)
Paper, board and pulps -- Measurement of diffuse blue reflectance factor -- Part 1:
Indoor daylight conditions (ISO brightness)
Papier, carton et pâtes -- Mesurage du facteur de réflectance diffuse dans le bleu --
Partie 1: Conditions d'éclairage intérieur de jour (degré de blancheur ISO)
Ta slovenski standard je istoveten z: ISO 2470-1:2016
ICS:
85.040 Vlaknine Pulps
85.060 Papir, karton in lepenka Paper and board
SIST ISO 2470-1:2017 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST ISO 2470-1:2017
---------------------- Page: 2 ----------------------
SIST ISO 2470-1:2017
INTERNATIONAL ISO
STANDARD 2470-1
Second edition
2016-09-15
Paper, board and pulps —
Measurement of diffuse blue
reflectance factor —
Part 1:
Indoor daylight conditions (ISO
brightness)
Papier, carton et pâtes — Mesurage du facteur de réflectance diffuse
dans le bleu —
Partie 1: Conditions d’éclairage intérieur de jour (degré de
blancheur ISO)
Reference number
ISO 2470-1:2016(E)
©
ISO 2016
---------------------- Page: 3 ----------------------
SIST ISO 2470-1:2017
ISO 2470-1:2016(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2016, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2016 – All rights reserved
---------------------- Page: 4 ----------------------
SIST ISO 2470-1:2017
ISO 2470-1:2016(E)
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 2
5 Apparatus . 2
5.1 Reflectometer . 2
5.2 Reference standards for calibration of the instrument and the working standards . 3
5.3 Working standards . 3
6 Sampling and conditioning . 3
7 Preparation of test pieces . 3
8 Procedure. 4
9 Expression of results . 4
10 Test report . 4
Annex A (normative) Spectral characteristics of instruments for measuring ISO brightness .6
Annex B (normative) UV calibration service . 8
Annex C (informative) Precision .10
Bibliography .11
© ISO 2016 – All rights reserved iii
---------------------- Page: 5 ----------------------
SIST ISO 2470-1:2017
ISO 2470-1:2016(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment,
as well as information about ISO’s adherence to the World Trade Organization (WTO) principles in the
Technical Barriers to Trade (TBT) see the following URL: www.iso.org/iso/foreword.html.
The committee responsible for this document is ISO/TC 6, Paper, board and pulps.
This second edition cancels and replaces the first edition (ISO 2470-1:2009), of which it constitutes a
minor revision including the following modifications:
— references in Clause 2 and in the Bibliography have been updated;
— the terminology (Clause 3) has been revised to be consistent with the information provided in
ISO/TR 10688 and, wherever possible, with the symbols used in the CIE International Lighting
Vocabulary;
— references to “ISO/TC 6 authorized laboratories” have been eliminated;
— the precision statement has been moved to an informative annex (Annex C).
ISO 2470 consists of the following parts, under the general title Paper, board and pulps — Measurement
of diffuse blue reflectance factor:
— Part 1: Indoor daylight conditions (ISO brightness)
— Part 2: Outdoor daylight conditions (D65 brightness)
iv © ISO 2016 – All rights reserved
---------------------- Page: 6 ----------------------
SIST ISO 2470-1:2017
ISO 2470-1:2016(E)
Introduction
The diffuse reflectance factor (radiance factor) depends on the conditions of measurement, particularly
the spectral and geometric characteristics of the instrument used. This part of ISO 2470 is therefore
intended to be read in conjunction with ISO 2469 which defines the geometric characteristics of the
instrument and also defines the photometric calibration procedure to be adopted.
The definition of ISO brightness is historically linked to the Zeiss Elrepho instrument having, as a light
source, an incandescent lamp which excites fluorescence to only a limited extent. It is specified here
that, in instruments of the abridged spectrophotometer or filter colorimeter type, the UV content of
the illumination be adjusted to conform to the CIE illuminant C as defined by a fluorescent reference
standard having an assigned value of ISO brightness as described in Annex B. Only if this is done can
the property measured on a fluorescent material be called ISO brightness.
© ISO 2016 – All rights reserved v
---------------------- Page: 7 ----------------------
SIST ISO 2470-1:2017
---------------------- Page: 8 ----------------------
SIST ISO 2470-1:2017
INTERNATIONAL STANDARD ISO 2470-1:2016(E)
Paper, board and pulps — Measurement of diffuse blue
reflectance factor —
Part 1:
Indoor daylight conditions (ISO brightness)
1 Scope
This part of ISO 2470 specifies a method for measuring the diffuse blue reflectance factor (ISO
brightness) of pulps, papers and boards.
This part of ISO 2470 is limited in its scope to white and near-white pulps, papers and boards. The
measurement can only be made in an instrument in which the ultraviolet energy level of the illumination
[6]
has been adjusted to correspond to the CIE illuminant C using a fluorescent reference standard.
The CIE illuminant C is taken to be representative of indoor daylight conditions because it contains a
[9]
suitable proportion of UV radiation.
NOTE The property called D65 brightness is measured with an instrument adjusted to correspond with CIE
[4]
standard illuminant D65, which has a much higher UV content than that specified in this part of ISO 2470. The
[2]
measurement of D65 brightness is described in ISO 2470-2.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 186, Paper and board — Sampling to determine average quality
ISO 2469, Paper, board and pulps — Measurement of diffuse radiance factor (diffuse reflectance factor)
ISO 3688, Pulps — Preparation of laboratory sheets for the measurement of diffuse blue reflectance factor
(ISO brightness)
ISO 4094, Paper, board and pulps — International calibration of testing apparatus — Nomination and
acceptance of standardizing and authorized laboratories
ISO 7213, Pulps — Sampling for testing
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
diffuse radiance factor
β
ratio of the diffusely reflected radiance of a body in a given direction to that of the perfect reflecting
diffuser under specified conditions of irradiation
Note 1 to entry: For fluorescent (luminescent) materials, the specified conditions of irradiation in this part of
ISO 2470 are CIE illuminant C and the diffuse radiance factor is strictly the total radiance factor, β, which is the
sum of two components, the reflected radiance factor, β , and the luminescent radiance factor, β , so that:
R L
β = β + β
R L
© ISO 2016 – All rights reserved 1
---------------------- Page: 9 ----------------------
SIST ISO 2470-1:2017
ISO 2470-1:2016(E)
Note 2 to entry: For non-fluorescent materials, the diffuse radiance factor, β , is simply the diffuse reflectance
R
factor R.
3.2
diffuse reflectance factor
R
ratio of the radiation reflected and emitted from a body to that reflected from the perfect reflecting
diffuser under the same conditions of diffuse illumination and normal detection
Note 1 to entry: The ratio is often expressed as a percentage.
Note 2 to entry: The diffuse reflectance factor is influenced by the backing if the body is translucent.
Note 3 to entry: This part of ISO 2470 prescribes diffuse illumination and normal detection in an instrument
calibrated in accordance with the provisions of this part of ISO 2470.
3.3
intrinsic diffuse reflectance factor
R
∞
diffuse reflectance factor of a layer or pad of material thick enough to be opaque, i.e. such that increasing
the thickness of the pad by doubling the number of sheets results in no change in the measured radiance
[reflectance] factor
Note 1 to entry: The diffuse reflectance factor of a single non-opaque sheet is dependent on the background and
is not a material property.
3.4
ISO brightness
R
457
intrinsic diffuse radiance (reflectance) factor measured with a reflectometer having the characteristics
described in ISO 2469, equipped with a filter or corresponding function having an effective wavelength
of 457 nm and a half bandwidth of 44 nm, and adjusted so that the UV content of the irradiation incident
upon the test piece corresponds to that of the CIE illuminant C
Note 1 to entry: The filter function is described more fully by the weighting function factors given in Annex A and
Table A.1.
4 Principle
A test piece is illuminated diffusely in a standard instrument and the light reflected normal to the
surface is either allowed to pass through a defined optical filter and then measured by a photodetector
or measured by an array of photosensitive diodes, where each diode responds to a different effective
wavelength. The brightness is then determined directly from the output from the photodetector or by
calculation from the photosensitive diode outputs using the appropriate weighting function.
5 Apparatus
5.1 Reflectometer
5.1.1 Reflectometer having the geometric, spectral and photometric characteristics described
in ISO 2469 and calibrated in accordance with the provisions of ISO 2469, and equipped for the
measurement of blue reflectance factor as defined in Annex A.
5.1.2 In the case of a filter reflectometer, the radiation falling upon the test piece shall have a UV
content corresponding to that of the CIE illuminant C.
5.1.3 In the case of an abridged spectrophotometer, the instrument shall have an adjustable filter with
a cut-off wavelength of 395 nm or some other system for adjustment and control, and this filter shall be
2 © ISO 2016 – All rights reserved
---------------------- Page: 10 ----------------------
SIST ISO 2470-1:2017
ISO 2470-1:2016(E)
adjusted or the system shall be calibrated with the help of the fluorescence reference standard (5.2.3), so
that t
...
NORME ISO
INTERNATIONALE 2470-1
Deuxième édition
2016-09-15
Papier, carton et pâtes — Mesurage
du facteur de réflectance diffuse dans
le bleu —
Partie 1:
Conditions d’éclairage intérieur de
jour (degré de blancheur ISO)
Paper, board and pulps — Measurement of diffuse blue reflectance
factor —
Part 1: Indoor daylight conditions (ISO brightness)
Numéro de référence
ISO 2470-1:2016(F)
©
ISO 2016
---------------------- Page: 1 ----------------------
ISO 2470-1:2016(F)
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2016, Publié en Suisse
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2016 – Tous droits réservés
---------------------- Page: 2 ----------------------
ISO 2470-1:2016(F)
Sommaire Page
Avant-propos .iv
Introduction .v
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 1
4 Principe . 2
5 Appareillage . 3
5.1 Réflectomètre . 3
5.2 Étalons de référence pour l’étalonnage de l’appareil et des étalons de travail . 3
5.3 Étalons de travail . 3
6 Échantillonnage et conditionnement . 3
7 Préparation des éprouvettes . 4
8 Mode opératoire. 4
9 Expression des résultats. 4
10 Rapport d’essai . 5
Annexe A (normative) Caractéristiques spectrales des appareils de mesure
du degré de blancheur ISO . 6
Annexe B (normative) Service d’étalonnage de la teneur en UV . 8
Annexe C (informative) Fidélité .10
Bibliographie .11
© ISO 2016 – Tous droits réservés iii
---------------------- Page: 3 ----------------------
ISO 2470-1:2016(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1 Il convient, en particulier, de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www.
iso.org/directives).
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www.iso.org/brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la signification des termes et expressions spécifiques de l’ISO liés à l’évaluation
de la conformité, ou pour toute information au sujet de l’adhésion de l’ISO aux principes de l’Organisation
mondiale du commerce (OMC) concernant les obstacles techniques au commerce (OTC), voir le lien
suivant: www.iso.org/iso/fr/avant-propos.html.
Le comité chargé de l’élaboration du présent document est l’ISO/TC 6, Papiers, cartons et pâtes.
Cette deuxième édition annule et remplace la première édition (ISO 2470-1:2009), dont les articles ont
fait l’objet d’une révision mineure incluant les modifications suivantes:
— les références de l’Article 2 et de la Bibliographie ont été mises à jour;
— la terminologie (Article 3) a été revue pour être conforme à l’information fournie dans
l’ISO/TR 10668 et, dans la mesure du possible, aux symboles utilisés dans le vocabulaire
international de l’éclairage, CIE;
— les références aux «laboratoires agréés de l’ISO/TC 6» ont été éliminées;
— les données de fidélité ont été déplacées dans une annexe informative (Annexe C).
L’ISO 2470 comprend les parties suivantes, présentées sous le titre général Papier, carton et pâtes —
Mesurage du facteur de réflectance diffuse dans le bleu:
— Partie 1: Conditions d’éclairage intérieur de jour (degré de blancheur ISO)
— Partie 2: Conditions de lumière du jour extérieure (degré de blancheur D65)
iv © ISO 2016 – Tous droits réservés
---------------------- Page: 4 ----------------------
ISO 2470-1:2016(F)
Introduction
Le facteur de réflectance diffuse (facteur de luminance énergétique) dépend des conditions de mesurage,
en particulier des caractéristiques spectrales et géométriques de l’appareil utilisé. La présente partie
de l’ISO 2470 est destinée à être lue conjointement avec l’ISO 2469 qui définit les caractéristiques
géométriques de l’appareil ainsi que le mode opératoire d’étalonnage photométrique à adopter.
La définition du degré de blancheur ISO est historiquement liée à l’appareil Elrepho Zeiss dont la source
lumineuse est une lampe à incandescence qui n’excite la fluorescence que de façon limitée. Il est spécifié
ici que, sur les appareils du type spectrophotomètre continu ou colorimètre à filtre, la teneur en UV de
l’éclairage doit être réglée afin qu’elle soit conforme à celle de l’illuminant CIE C, définie par un étalon
de référence fluorescent auquel est attribué un degré de blancheur ISO, comme décrit à l’Annexe B. Ce
n’est que dans ce cas que la propriété mesurée sur un matériau fluorescent peut être appelée degré de
blancheur ISO.
© ISO 2016 – Tous droits réservés v
---------------------- Page: 5 ----------------------
NORME INTERNATIONALE ISO 2470-1:2016(F)
Papier, carton et pâtes — Mesurage du facteur de
réflectance diffuse dans le bleu —
Partie 1:
Conditions d’éclairage intérieur de jour (degré de
blancheur ISO)
1 Domaine d’application
La présente partie de l’ISO 2470 spécifie une méthode de mesure du facteur de réflectance diffuse dans
le bleu (degré de blancheur ISO) des pâtes, papiers et cartons.
La présente partie de l’ISO 2470 se limite aux pâtes, papiers et cartons blancs ou presque blancs. Le
mesurage ne peut être effectué qu’à l’aide d’un appareil dans lequel le niveau d’énergie ultraviolette
de l’éclairage a été réglé à l’aide d’un étalon de référence fluorescent pour correspondre à
[6]
l’illuminant CIE C . L’illuminant CIE C est défini comme étant représentatif des conditions de lumière
[9]
du jour à l’intérieur parce qu’il contient une proportion appropriée de rayonnement UV .
NOTE La propriété appelée degré de blancheur D65 est mesurée à l’aide d’un appareil réglé pour
[4]
correspondre à l’illuminant CIE normalisé D65, qui a une teneur en UV beaucoup plus élevée que celle spécifiée
[2]
dans la présente partie de l’ISO 2470. Le mesurage du degré de blancheur D65 est décrit dans l’ISO 2470-2 .
2 Références normatives
Les documents ci-après, dans leur intégralité ou non, sont des références normatives indispensables à
l’application du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les
références non datées, la dernière édition du document de référence s’applique (y compris les éventuels
amendements).
ISO 186, Papier et carton — Échantillonnage pour déterminer la qualité moyenne
ISO 2469, Papier, carton et pâtes — Mesurage du facteur de luminance énergétique diffuse (facteur de
réflectance diffuse)
ISO 3688, Pâtes — Préparation des feuilles de laboratoire pour le mesurage du facteur de réflectance
diffuse dans le bleu (degré de blancheur ISO)
ISO 4094, Papiers, cartons et pâtes — Étalonnage international des appareils d’essai — Désignation et
agrément des laboratoires de référence et des laboratoires agréés
ISO 7213, Pâtes — Échantillonnage pour essais
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s’appliquent.
© ISO 2016 – Tous droits réservés 1
---------------------- Page: 6 ----------------------
ISO 2470-1:2016(F)
3.1
facteur de luminance énergétique diffuse
β
rapport de la radiance réfléchie de manière diffuse d’un corps dans une direction donnée à celle du
diffuseur parfait par réflexion, dans les conditions spécifiées de rayonnement
Note 1 à l’article: Pour les matériaux fluorescents (luminescents), les conditions spécifiées de rayonnement
dans la présente partie de l’ISO 2470 sont l’illuminant CIE C et le facteur de luminance énergétique diffuse est
strictement le facteur de luminance énergétique totale, β, qui est la somme de deux composants, le facteur de
luminance énergétique réfléchie, β , et le facteur de luminance énergétique par luminescence, β , de sorte que:
R L
β = β + β
R L
Note 2 à l’article: Pour les matériaux non fluorescents, la valeur du facteur de luminance énergétique diffuse, β ,
R
est simplement le facteur de réflectance diffuse R.
3.2
facteur de réflectance diffuse
R
rapport du rayonnement réfléchi et émis par un corps au rayonnement réfléchi par le diffuseur parfait,
dans les mêmes conditions d’éclairage diffus et de détection normale
Note 1 à l’article: Ce rapport est souvent exprimé en pourcentage.
Note 2 à l’article: Le facteur de réflectance diffuse dépend du fond si le corps est translucide.
Note 3 à l’article: La présente partie de l’ISO 2470 spécifie l’utilisation d’un éclairage diffus et d’une détection
normale dans un appareil étalonné conformément aux dispositions de la présente partie de l’ISO 2470.
3.3
facteur de réflectance diffuse intrinsèque
R
∞
facteur de réflectance diffuse d’une couche ou d’une liasse de matériau suffisamment épaisse pour
être opaque, c’est-à-dire telle que l’augmentation de l’épaisseur de la liasse par doublement du nombre
de feuilles la constituant, n’engendre aucune modification du facteur de luminance [réflectance]
énergétique mesuré
Note 1 à l’article: Le facteur de réflectance diffuse d’une feuille unique non opaque dépend du fond et n’est pas
une propriété du matériau.
3.4
degré de blancheur ISO
R
457
facteur de luminance diffuse (réflectance) intrinsèque, mesuré avec un réflectomètre présentant les
caractéristiques décrites dans l’ISO 2469, équipé d’un filtre ou doté d’une fonction correspondante,
ayant une longueur d’onde efficace de 457 nm et une largeur de bande à mi-hauteur de 44 nm, et réglé
de manière que la teneur en UV du rayonnement incident arrivant sur l’éprouvette corresponde à celle
de l’illuminant CIE C
Note 1 à l’article: Les facteurs de la fonction de pondération donnés à l’Annexe A et dans le Tableau A.1 décrivent
plus précisément la fonction du filtre.
4 Principe
Une éprouvette est éclairée de manière diffuse dans un instrument normalisé et la lumière réfléchie
perpendiculairement à la surface soit passe à travers un filtre optique défini pour être ensuite mesurée
à l’aide d’un photodétecteur, soit est mesurée à l’aide d’un réseau de diodes photosensibles, chacune
correspondant à une longueur d’onde efficace différente. Le degré de blancheur est alors déterminé
directement à partir de la valeur de sortie du photodétecteur ou par calcul à partir des données de
sortie des diodes photosensibles en appliquant la fonction de pondération appropriée.
2 © ISO 2016 – Tous droits réservés
---------------------- Page: 7 ----------------------
ISO 2470-1:2016(F)
5 Appareillage
5.1 Réflectomètre
5.1.1 Réflectomètre ayant les caractéristiques géométriques, spectrales et photométriques décrites
dans l’ISO 2469, étalonné conformément aux dispositions de l’ISO 2469, et équipé pour mesurer le
facteur de réflectance dans le bleu, tel que défini à l’Annexe A.
5.1.2 Dans le cas d’un réflectomètre à filtre, le rayonnement tombant sur l’éprouvette doit avoir une
teneur en UV correspondant à celle de l’illuminant CIE C.
5.1.3 Dans le cas d’un spectrophotomètre continu, l’appareil doit être doté d’un filtre réglable ayant
une longueur d’onde de coupure de 395 nm ou d’un autre système de réglage et de contrôle, ce filtre
devant être réglé ou le système étalonné à l’aide de l’étalon de référence fluorescent (5.2.3), de manière
que la teneur en UV du rayonnement tombant sur l’échantillon corresponde à celle de l’illuminant CIE C.
5.2 Étalons de référence pour l’étalonnage de l’appareil et des étalons de travail
5.2.1 Utiliser les étalons de référence de manière suffisamment fréquente pour garantir un
étalonnage et un réglage des UV satisfaisants.
NOTE Cet intervalle de fréquence peut être fixé selon un calendrier défini ou des limites de contrôle (par
exemple à partir de l’analyse de la dérive de l’instrument de mesure).
5.2.2 Étalon de référence non fluorescent pour l’étalonnage photométrique, satis
...
PROJET
NORME ISO/FDIS
FINAL
INTERNATIONALE 2470-1
ISO/TC 6
Papier, carton et pâtes — Mesurage
Secrétariat: SCC
du facteur de réflectance diffuse dans
Début de vote:
2016-05-26 le bleu —
Vote clos le:
Partie 1:
2016-07-20
Conditions d’éclairage intérieur de
jour (degré de blancheur ISO)
Paper, board and pulps — Measurement of diffuse blue reflectance
factor —
Part 1: Indoor daylight conditions (ISO brightness)
LES DESTINATAIRES DU PRÉSENT PROJET SONT
INVITÉS À PRÉSENTER, AVEC LEURS OBSER-
VATIONS, NOTIFICATION DES DROITS DE PRO-
PRIÉTÉ DONT ILS AURAIENT ÉVENTUELLEMENT
CONNAISSANCE ET À FOURNIR UNE DOCUMEN-
TATION EXPLICATIVE.
OUTRE LE FAIT D’ÊTRE EXAMINÉS POUR
ÉTABLIR S’ILS SONT ACCEPTABLES À DES FINS
INDUSTRIELLES, TECHNOLOGIQUES ET COM-
Numéro de référence
MERCIALES, AINSI QUE DU POINT DE VUE
ISO/FDIS 2470-1:2016(F)
DES UTILISATEURS, LES PROJETS DE NORMES
INTERNATIONALES DOIVENT PARFOIS ÊTRE
CONSIDÉRÉS DU POINT DE VUE DE LEUR POSSI-
BILITÉ DE DEVENIR DES NORMES POUVANT
SERVIR DE RÉFÉRENCE DANS LA RÉGLEMENTA-
©
TION NATIONALE. ISO 2016
---------------------- Page: 1 ----------------------
ISO/FDIS 2470-1:2016(F)
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2016, Publié en Suisse
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2016 – Tous droits réservés
---------------------- Page: 2 ----------------------
ISO/FDIS 2470-1:2016(F)
Sommaire Page
Avant-propos .iv
Introduction .v
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 1
4 Principe . 2
5 Appareillage . 3
5.1 Réflectomètre . 3
5.2 Étalons de référence pour l’étalonnage de l’appareil et des étalons de travail . 3
5.3 Étalons de travail . 3
6 Échantillonnage et conditionnement . 3
7 Préparation des éprouvettes . 4
8 Mode opératoire. 4
9 Expression des résultats. 4
10 Rapport d’essai . 5
Annexe A (normative) Caractéristiques spectrales des appareils de mesure
du degré de blancheur ISO . 6
Annexe B (normative) Service d’étalonnage de la teneur en UV . 8
Annexe C (informative) Fidélité .10
Bibliographie .11
© ISO 2016 – Tous droits réservés iii
---------------------- Page: 3 ----------------------
ISO/FDIS 2470-1:2016(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www.
iso.org/directives).
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www.iso.org/brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la signification des termes et expressions spécifiques de l’ISO liés à
l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion de l’ISO aux principes
de l’OMC concernant les obstacles techniques au commerce (OTC), voir le lien suivant: Avant-propos —
Informations supplémentaires.
Le comité chargé de l’élaboration du présent document est l’ISO/TC 6, Papiers, cartons et pâtes.
Cette deuxième édition annule et remplace la première édition (ISO 2470-1:2009), dont les articles ont
fait l’objet d’une révision mineure incluant les modifications suivantes:
— les références de l’Article 2 et de la Bibliographie ont été mises à jour;
— la terminologie (Article 3) a été revue pour être conforme à l’information fournie dans
l’ISO/TR 10668 et, dans la mesure du possible, aux symboles utilisés dans le vocabulaire
international de l’éclairage, CIE;
— les références aux « laboratoires agréés de l’«ISO/TC 6» ont été éliminées;
— les données de fidélité ont été déplacées dans une annexe informative (Annexe C).
L’ISO 2470 comprend les parties suivantes, présentées sous le titre général Papier, carton et pâtes —
Mesurage du facteur de réflectance diffuse dans le bleu:
— Partie 1: Conditions d’éclairage intérieur de jour (degré de blancheur ISO)
— Partie 2: Conditions de lumière du jour extérieure (degré de blancheur D65)
iv © ISO 2016 – Tous droits réservés
---------------------- Page: 4 ----------------------
ISO/FDIS 2470-1:2016(F)
Introduction
Le facteur de réflectance diffuse (facteur de luminance énergétique) dépend des conditions de mesurage,
en particulier des caractéristiques spectrales et géométriques de l’appareil utilisé. La présente partie
de l’ISO 2470 est destinée à être lue conjointement avec l’ISO 2469 qui définit les caractéristiques
géométriques de l’appareil ainsi que le mode opératoire d’étalonnage photométrique à adopter.
La définition du degré de blancheur ISO est historiquement liée à l’appareil Elrepho Zeiss dont la source
lumineuse est une lampe à incandescence qui n’excite la fluorescence que de façon limitée. Il est spécifié
ici que, sur les appareils du type spectrophotomètre continu ou colorimètre à filtre, la teneur en UV de
l’éclairage doit être réglée afin qu’elle soit conforme à celle de l’illuminant CIE C, définie par un étalon
de référence fluorescent auquel est attribué un degré de blancheur ISO, comme décrit à l’Annexe B. Ce
n’est que dans ce cas que la propriété mesurée sur un matériau fluorescent peut être appelée degré de
blancheur ISO.
© ISO 2016 – Tous droits réservés v
---------------------- Page: 5 ----------------------
PROJET FINAL DE NORME INTERNATIONALE ISO/FDIS 2470-1:2016(F)
Papier, carton et pâtes — Mesurage du facteur de
réflectance diffuse dans le bleu —
Partie 1:
Conditions d’éclairage intérieur de jour (degré de
blancheur ISO)
1 Domaine d’application
La présente partie de l’ISO 2470 spécifie une méthode de mesure du facteur de réflectance diffuse dans
le bleu (degré de blancheur ISO) des pâtes, papiers et cartons.
La présente partie de l’ISO 2470 se limite aux pâtes, papiers et cartons blancs ou presque blancs. Le
mesurage ne peut être effectué qu’à l’aide d’un appareil dans lequel le niveau d’énergie ultraviolette
de l’éclairage a été réglé à l’aide d’un étalon de référence fluorescent pour correspondre à
[6]
l’illuminant CIE C . L’illuminant CIE C est défini comme étant représentatif des conditions de lumière
[9]
du jour à l’intérieur parce qu’il contient une proportion appropriée de rayonnement UV .
NOTE La propriété appelée degré de blancheur D65 est mesurée à l’aide d’un appareil réglé pour
[4]
correspondre à l’illuminant CIE normalisé D65, qui a une teneur en UV beaucoup plus élevée que celle spécifiée
[2]
dans la présente partie de l’ISO 2470. Le mesurage du degré de blancheur D65 est décrit dans l’ISO 2470-2 .
2 Références normatives
Les documents ci-après, dans leur intégralité ou non, sont des références normatives indispensables à
l’application du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les
références non datées, la dernière édition du document de référence s’applique (y compris les éventuels
amendements).
ISO 186, Papier et carton — Échantillonnage pour déterminer la qualité moyenne
ISO 2469, Papier, carton et pâtes — Mesurage du facteur de luminance énergétique diffuse (facteur de
réflectance diffuse)
ISO 3688, Pâtes — Préparation des feuilles de laboratoire pour le mesurage du facteur de réflectance
diffuse dans le bleu (degré de blancheur ISO)
ISO 4094, Papiers, cartons et pâtes — Étalonnage international des appareils d’essai — Désignation et
agrément des laboratoires de référence et des laboratoires agréés
ISO 7213, Pâtes — Échantillonnage pour essais
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s’appliquent.
© ISO 2016 – Tous droits réservés 1
---------------------- Page: 6 ----------------------
ISO/FDIS 2470-1:2016(F)
3.1
facteur de luminance énergétique diffuse
β
rapport de la radiance réfléchie de manière diffuse d’un corps dans une direction donnée à celle du
diffuseur parfait par réflexion, dans les conditions spécifiées de rayonnement
Note 1 à l’article: Pour les matériaux fluorescents (luminescents), les conditions spécifiées de rayonnement
dans la présente partie de l’ISO 2470 sont l’illuminant CIE C et le facteur de luminance énergétique diffuse est
strictement le facteur de luminance énergétique totale, β, qui est la somme de deux composants, le facteur de
luminance énergétique réfléchie, β , et le facteur de luminance énergétique par luminescence, β , de sorte que:
R L
β = β + β
R L
Note 2 à l’article: Pour les matériaux non fluorescents, la valeur du facteur de luminance énergétique diffuse, β ,
R
est simplement le facteur de réflectance diffuse R.
3.2
facteur de réflectance diffuse
R
rapport du rayonnement réfléchi et émis par un corps au rayonnement réfléchi par le diffuseur parfait,
dans les mêmes conditions d’éclairage diffus et de détection normale
Note 1 à l’article: Ce rapport est souvent exprimé en pourcentage.
Note 2 à l’article: Le facteur de réflectance diffuse dépend du fond si le corps est translucide.
Note 3 à l’article: La présente partie de l’ISO 2470 spécifie l’utilisation d’un éclairage diffus et d’une détection
normale dans un appareil étalonné conformément aux dispositions de la présente partie de l’ISO 2470.
3.3
facteur de réflectance diffuse intrinsèque
R
∞
facteur de réflectance diffuse d’une couche ou d’une liasse de matériau suffisamment épaisse pour
être opaque, c’est-à-dire telle que l’augmentation de l’épaisseur de la liasse par doublement du nombre
de feuilles la constituant, n’engendre aucune modification du facteur de luminance [réflectance]
énergétique mesuré
Note 1 à l’article: Le facteur de réflectance diffuse d’une feuille unique non opaque dépend du fond et n’est pas
une propriété du matériau.
3.4
degré de blancheur ISO
R
457
facteur de luminance diffuse (réflectance) intrinsèque, mesuré avec un réflectomètre présentant les
caractéristiques décrites dans l’ISO 2469, équipé d’un filtre ou doté d’une fonction correspondante,
ayant une longueur d’onde efficace de 457 nm et une largeur de bande à mi-hauteur de 44 nm, et réglé
de manière que la teneur en UV du rayonnement incident arrivant sur l’éprouvette corresponde à celle
de l’illuminant CIE C
Note 1 à l’article: Les facteurs de la fonction de pondération donnés à l’Annexe A et dans le Tableau A.1 décrivent
plus précisément la fonction du filtre.
4 Principe
Une éprouvette est éclairée de manière diffuse dans un instrument normalisé et la lumière réfléchie
perpendiculairement à la surface soit passe à travers un filtre optique défini pour être ensuite mesurée
à l’aide d’un photodétecteur, soit est mesurée à l’aide d’un réseau de diodes photosensibles, chacune
correspondant à une longueur d’onde efficace différente. Le degré de blancheur est alors déterminé
directement à partir de la valeur de sortie du photodétecteur ou par calcul à partir des données de
sortie des diodes photosensibles en appliquant la fonction de pondération appropriée.
2 © ISO 2016 – Tous droits réservés
---------------------- Page: 7 ----------------------
ISO/FDIS 2470-1:2016(F)
5 Appareillage
5.1 Réflectomètre
5.1.1 Réflectomètre ayant les caractéristiques géométriques, spectrales et photométriques décrites
dans l’ISO 2469, étalonné conformément aux dispositions de l’ISO 2469, et équipé pour mesurer le
facteur de réflectance dans le bleu, tel que défini à l’Annexe A.
5.1.2 Dans le cas d’un réflectomètre à filtre, le rayonnement tombant sur l’éprouvette doit avoir une
teneur en UV correspondant à celle de l’illuminant CIE C.
5.1.3 Dans le cas d’un spectrophotomètre continu, l’appareil doit être doté d’un filtre réglable ayant
une longueur d’onde de coupure de 395 nm ou d’un autre système de réglage et de contrôle, ce filtre
devant être réglé ou le système étalonné à l’aide de l’étalon de référence fluorescent (5.2.3), de manière
que la teneur en UV du rayonnement tombant sur l’échantillon corresponde à celle de l’illuminant CIE C.
5.2 Étalons de référence pour l’étalonnage de l’appareil et des étalons de travail
5.2.1 Utiliser les étalons de référence de manière suffisamment fréquente pour garantir un
étalonnage et un réglage des UV satisfaisants.
NOTE Cet in
...
Questions, Comments and Discussion