ISO 17089-1:2019
(Main)Measurement of fluid flow in closed conduits — Ultrasonic meters for gas — Part 1: Meters for custody transfer and allocation measurement
Measurement of fluid flow in closed conduits — Ultrasonic meters for gas — Part 1: Meters for custody transfer and allocation measurement
This document specifies requirements and recommendations for ultrasonic gas flowmeters (USMs), which utilize the transit time of acoustic signals to measure the flow of single phase homogenous gases in closed conduits. This document applies to transit time ultrasonic gas flowmeters used for custody transfer and allocation metering, such as full-bore, reduced-area, high-pressure, and low-pressure meters or any combination of these. There are no limits on the minimum or maximum sizes of the meter. This document can be applied to the measurement of almost any type of gas, such as air, natural gas, and ethane. Included are flow measurement performance requirements for meters of two accuracy classes suitable for applications such as custody transfer and allocation measurement. This document specifies construction, performance, calibration, diagnostics for meter verification, and output characteristics of ultrasonic meters for gas flow measurement and deals with installation conditions. NOTE It is possible that national or other regulations apply which can be more stringent than those in this document.
Mesurage du débit des fluides dans les conduites fermées — Compteurs à ultrasons pour gaz — Partie 1: Compteurs pour transactions commerciales et allocations
Le présent document spécifie les exigences et les recommandations relatives aux compteurs à ultrasons pour gaz qui utilisent le temps de transit de signaux acoustiques pour mesurer le débit de gaz homogènes à phase unique dans des conduites fermées. Le présent document s'applique aux compteurs à ultrasons à temps de transit pour gaz utilisés pour le mesurage des transactions commerciales et des allocations, tels que les compteurs à passage intégral, les compteurs à surface réduite, les compteurs haute pression, les compteurs basse pression et toute combinaison de ceux-ci. Il n'y a pas de limites aux dimensions minimales ou maximales du compteur. Le présent document peut s'appliquer au mesurage de pratiquement tous les types de gaz, tels que l'air, le gaz naturel et l'éthane. Des exigences de performance de mesurage du débit sont incluses pour les compteurs appartenant à deux classes d'exactitude appropriées pour des applications telles que le mesurage à des fins de transactions commerciales et d'allocations. Le présent document spécifie la construction, les performances, l'étalonnage, le diagnostic pour la vérification des compteurs et les caractéristiques du signal de sortie des compteurs à ultrasons employés pour le mesurage du débit de gaz et traite des conditions d'installation. NOTE Il est possible que des réglementations nationales ou d'autres réglementations qui s'appliquent soient plus sévères que celles données dans le présent document.
General Information
Relations
Buy Standard
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 17089-1
Second edition
2019-08
Measurement of fluid flow in closed
conduits — Ultrasonic meters for gas —
Part 1:
Meters for custody transfer and
allocation measurement
Mesurage du débit des fluides dans les conduites fermées —
Compteurs à ultrasons pour gaz —
Partie 1: Compteurs pour transactions commerciales et allocations
Reference number
©
ISO 2019
© ISO 2019
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2019 – All rights reserved
Contents Page
Foreword .vi
Introduction .vii
1 Scope . 1
2 Normative references . 1
3 Terms, definitions and symbols . 1
3.1 Terms and definitions . 1
3.1.1 Quantities . 2
3.1.2 Meter design . 2
3.1.3 Thermodynamic conditions . 3
3.1.4 Statistics . 3
3.2 Symbols and subscripts . 5
3.3 Abbrevations . 7
4 Principles of measurement . 7
4.1 Basic formulae . 7
4.2 Factors affecting the performance . 9
4.3 Description of generic types. 9
4.3.1 General. 9
4.3.2 Transducers. 9
4.3.3 Meter body and acoustic path configurations .10
4.3.4 Average velocity calculation.12
4.4 Contributions to the uncertainty in measurement .13
4.5 Reynolds number .13
4.6 USM classification .13
5 Meter characteristics .14
5.1 Operating conditions .14
5.1.1 Flow rates and gas velocities .14
5.1.2 Pressure .14
5.1.3 Temperature .14
5.1.4 Gas quality .14
5.2 Meter body, materials, and construction .15
5.2.1 Materials .15
5.2.2 Meter body .15
5.2.3 Connections .15
5.2.4 Dimensions .15
5.2.5 Ultrasonic transducer ports .16
5.2.6 Pressure tappings .16
5.2.7 Anti-roll provision .16
5.2.8 Flow conditioner .17
5.2.9 Markings .17
5.2.10 Corrosion protection .18
5.3 Transducers .18
5.3.1 Specification . .18
5.3.2 Rate of pressure change.18
5.3.3 Transducer characterization .18
5.3.4 Path configuration .18
5.3.5 Marking .18
5.3.6 Cable .18
5.3.7 Robustness .19
5.4 Electronics .19
5.4.1 General requirements .19
5.4.2 Display .19
5.4.3 Power supply . .19
5.4.4 Signal detection method .19
5.4.5 Sampling or pulsating flow .19
5.4.6 Signal-to-noise ratio .19
5.4.7 Alarm signal .19
5.4.8 Processing of data .19
5.4.9 Output .20
5.4.10 Cable jackets and insulation.20
5.4.11 Marking .20
5.5 Software .20
5.5.1 Firmware .20
5.5.2 MODBUS communication data specification .21
5.5.3 Discontinuity .21
5.5.4 Marking and version management .21
5.5.5 Monitoring and recording of measuring and diagnostic data .21
5.5.6 Correction functions and parameters .21
5.5.7 Inspection and verification functions .22
5.6 Exchange of components . .22
5.7 Secondary measurements .22
5.7.1 General.22
5.7.2 Pressure measurement .22
5.7.3 Temperature measurement .22
5.8 Performance requirements .
...
NORME ISO
INTERNATIONALE 17089-1
Deuxième édition
2019-08
Mesurage du débit des fluides dans
les conduites fermées — Compteurs à
ultrasons pour gaz —
Partie 1:
Compteurs pour transactions
commerciales et allocations
Measurement of fluid flow in closed conduits — Ultrasonic meters
for gas —
Part 1: Meters for custody transfer and allocation measurement
Numéro de référence
©
ISO 2019
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2019
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
Fax: +41 22 749 09 47
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii © ISO 2019 – Tous droits réservés
Sommaire Page
Avant-propos .vi
Introduction .vii
1 Domaine d'application . 1
2 Références normatives . 1
3 Termes, définitions et symboles . 1
3.1 Termes et définitions . 1
3.1.1 Grandeurs . 2
3.1.2 Conception du compteur . 2
3.1.3 Conditions thermodynamiques . 3
3.1.4 Statistiques . 4
3.2 Symboles et indices . 5
3.3 Abréviations . 7
4 Principes de mesure . 7
4.1 Formules de base . 7
4.2 Facteurs ayant une incidence sur les performances . 9
4.3 Description des types génériques .10
4.3.1 Généralités .10
4.3.2 Transducteurs .10
4.3.3 Corps du compteur et configurations de trajet acoustique .11
4.3.4 Calcul de la vitesse moyenne .13
4.4 Contributions à l'incertitude de mesure .14
4.5 Nombre de Reynolds .14
4.6 Classification des compteurs à ultrasons .15
5 Caractéristiques du compteur .15
5.1 Conditions de fonctionnement .15
5.1.1 Débits et vitesses de gaz .15
5.1.2 Pression .15
5.1.3 Température .16
5.1.4 Qualité du gaz .16
5.2 Corps, matériaux et construction du compteur .16
5.2.1 Matériaux .16
5.2.2 Corps du compteur .16
5.2.3 Raccordements .16
5.2.4 Dimensions .17
5.2.5 Orifices des transducteurs à ultrasons .17
5.2.6 Prises de pression .17
5.2.7 Dispositif antiroulis .18
5.2.8 Tranquilliseur .18
5.2.9 Marquages .19
5.2.10 Protection contre la corrosion .20
5.3 Transducteurs .20
5.3.1 Spécification . .20
5.3.2 Vitesse de variation de la pression .20
5.3.3 Caractérisation des transducteurs .20
5.3.4 Configuration du trajet .20
5.3.5 Marquage .20
5.3.6 Câble .20
5.3.7 Robustesse .20
5.4 Électronique .20
5.4.1 Exigences générales .20
5.4.2 Affichage.21
5.4.3 Alimentation électrique .21
5.4.4 Méthode de détection du signal .21
5.4.5 Échantillonnage ou écoulement pulsatoire .21
5.4.6 Rapport signal/bruit .21
5.4.7 Signal d’alarme .21
5.4.8 Traitement des données .21
5.4.9 Sortie .21
5.4.10 Gaines et isolation de câble .22
5.4.11 Marquage .22
5.5 Logiciel .22
5.5.1 Micrologiciel .22
5.5.2 Spécification des données de communication MODBUS .23
5.5.3 Discontinuité .23
5.5.4 Marquage et gestion des versions .23
5.5.5 Surveillance et enregistrement des données de mesurage et de diagnostic .23
5.5.6 Paramètres et fonctions de correction .23
5.5.7 Fonctions d'inspection et de vérification .24
5.6 Échange de composants .24
5.7 Mesurages secondaires .25
5.7.1 Généralités .25
5.7.2 Mesurage de la pression .25
5.7.3 Mesurage de la température .25
5.8 Exigences de performance .26
5.8.1 Généralités .26
5.8.2 Exigences d’exactitude .
...