Identification cards — Integrated circuit cards — Part 4: Organization, security and commands for interchange — Amendment 1: Multiple record handling

Cartes d'identification — Cartes à circuit intégré — Partie 4: Organisation, sécurité et commandes pour les échanges — Amendement 1: Manutention multiple record

General Information

Status
Withdrawn
Publication Date
23-Jul-2018
Withdrawal Date
23-Jul-2018
Current Stage
9599 - Withdrawal of International Standard
Completion Date
27-May-2020
Ref Project

Relations

Buy Standard

Standard
ISO/IEC 7816-4:2013/Amd 1:2018 - Multiple record handling
English language
11 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO/IEC
STANDARD 7816-4
Third edition
2013-04-15
AMENDMENT 1
2018-08
Identification cards — Integrated
circuit cards —
Part 4:
Organization, security and commands
for interchange
AMENDMENT 1: Multiple record
handling
Cartes d'identification — Cartes à circuit intégré —
Partie 4: Organisation, sécurité et commandes pour les échanges
AMENDEMENT 1: Manutention multiple record
Reference number
ISO/IEC 7816-4:2013/Amd.1:2018(E)
©
ISO/IEC 2018

---------------------- Page: 1 ----------------------
ISO/IEC 7816-4:2013/Amd.1:2018(E)

COPYRIGHT PROTECTED DOCUMENT
© ISO/IEC 2018
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO/IEC 2018 – All rights reserved

---------------------- Page: 2 ----------------------
ISO/IEC 7816-4:2013/Amd.1:2018(E)

Foreword
ISO (the International Organization for Standardization) and IEC (the International Electrotechnical
Commission) form the specialized system for worldwide standardization. National bodies that are
members of ISO or IEC participate in the development of International Standards through technical
committees established by the respective organization to deal with particular fields of technical
activity. ISO and IEC technical committees collaborate in fields of mutual interest. Other international
organizations, governmental and non-governmental, in liaison with ISO and IEC, also take part in the
work. In the field of information technology, ISO and IEC have established a joint technical committee,
ISO/IEC JTC 1.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for
the different types of document should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject
of patent rights. ISO and IEC shall not be held responsible for identifying any or all such patent
rights. Details of any patent rights identified during the development of the document will be in the
Introduction and/or on the ISO list of patent declarations received (see www .iso .org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following
URL: www .iso .org/iso/foreword .html.
This document was prepared by ISO/IEC JTC 1, Information technology, SC 17, Cards and security devices
for personal identification.
© ISO/IEC 2018 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO/IEC 7816-4:2013/Amd.1:2018(E)
Identification cards — Integrated circuit cards —
Part 4:
Organization, security and commands for interchange
AMENDMENT 1: Multiple record handling

Page 17, Table 6
Replace text in the “Meaning” column for SW1 = ‘62‘ and SW2 = ‘87‘ with the following:
At least one of the referenced records is not processed for some reason, e.g. record deactivated,
security status not satisfied or conditions of use not satisfied.
Page 74, 11.3.2, second paragraph, third sentence
Replace the description in parentheses with the following:
At least one of the referenced records is not processed.
Page 74, 11.3.2, NOTE
Replace the text of the NOTE with the following:
If the number of records exceeds the numbering range ('01' to 'FE') of the record handling
command, records can be handled, e.g. by using next occurrence option of the record identifier, or
by using multiple record handling with record number DO‘02‘.
Page 74, 11.3.2, sixth paragraph
Replace the text in P2 with the following:
P2 — If bits b8 to b4 are not all equal, these bits are a short EF identifier according to Table 69
and bits b3 to b1 depend upon the command. If bits b8 to b1 are set to 11111000 (i.e. P2 = ‘F8‘), P2
indicates multiple record handling (for details, see 11.3.3 to 11.3.10).
Page 74, Table 69
Replace Table 69 and its title with the following:
Table 69 — Coding of P2
b8 b7 b6 b5 b4 b3 b2 b1 Meaning
0 0 0 0 0 — — — Current EF
Not all equal — — — Short EF identifier (a number from one to thirty)
1 1 1 1 1 0 0 0 Multiple record handling (for details, see 11.3.3 to 11.3.10)
1 1 1 1 1 Not all zero RFU
Page 74, 11.3.2
Add the following paragraph after the last paragraph:
In the multiple record handling option of this command group, SW1-SW2 set to ‘6287‘ indicates
that some command processes are done and others are not (e.g. some addressed records are read
© ISO/IEC 2018 – All rights reserved 1

---------------------- Page: 4 ----------------------
ISO/IEC 7816-4:2013/Amd.1:2018(E)

but others are not). SW1-SW2 set to ‘6F00‘ indicates that all command processes are not completed
for different reasons (e.g. record deactivated, security status not satisfied).
Page 75, 11.3.3
Add the following paragraphs before Table 70:
If INS = ‘B2‘ and bits b8 to b1 of P2 are set to 11111000 (i.e. P2 = ‘F8‘), then this command may read
multiple records in different EFs. The command data field contains one or more record handling
DO‘7F76‘ each containing one file reference DO‘51‘ and one or more integer DO‘02‘. The value field
of DO‘51‘ contains a file identifier or a short EF identifier indicating the record structure EF under
current DF. This field may also contain a relative path or an absolute path. The value field of DO‘02‘
is a record number to be read from the file referenced by DO‘51‘. DO‘02‘ may indicate record number
over 254. For each DO‘02‘ under DO‘7F76‘ in the command data field, the response data field
contains a corresponding DO‘53‘ or DO‘04‘. If the addressed record is readable (i.e. record exists,
record is activated and security status satisfies the security attributes) then the corresponding
DO‘53‘ contains the entire record. When present, a DO‘53‘ denotes an implicit normal processing
without corresponding status bytes, i.e. ‘9000‘. Otherwise the corresponding DO‘04‘ contains
value of status bytes defined in Table 5 and 6 indicating why the record data is not read. If at least
one addressed record is not read, the status bytes ‘6287‘ shall be returned. The VA and the record
pointer shall not be changed in case P2 = ‘F8‘.
If INS='B2' and P2 = 'F8' and the command data references missing files or files with incompatible
file structure or missing record(s), the command shall be aborted with the respective return code
from table 5 or 6 (e.g. command incompatible with file structure '6981', file not found '6A82', record
not found '6A83', etc.).
Page 75, Table 70
Replace the two rows in ’Data field‘ with the following:
INS = ‘B2‘ and bits b8 to b1 of P2 set to
One or more record handling DO‘7F76‘
11111000
Data field INS = ‘B2‘ and bits b8 to b1 of P2 not set to
Absent
11111000
INS = ‘B3‘ Offset DO
One or more discretionary data DO‘53‘
INS = ‘B2‘ and bits b8 to b1 of P2 set to
and/or DO‘04‘ containing value of
11111000
status bytes.
Data field INS = ‘B2‘ and bits b8 to b1 of P2 not set to
Data read
11111000
Discretionary DO for encapsulating the
INS = ‘B3‘
data read
2 © ISO/IEC 2018 – All rights reserved

---------------------- Page: 5 ----------------------
ISO/IEC 7816-4:2013/Amd.1:2018(E)

Page 75, Table 71
Replace Table 71 with the following table:
b8 b7 b6 b5 b4 b3 b2 b1 Meaning
x x x x x
— — — Short EF identifier according to Table 69
(Not all one)
0 x x Record identifier in P1
0 0 0 — Read first occurrence
0 0 1 — Read last occurrence
0 1 0 — Read next occurrence
Not all one 0 1 1 — Read previous occurrence
1 x x Record number in P1
1 0 0 — Read record P1
1 0 1 — Read all records from P1 up to the last (for INS = ‘B2‘ only)
1 1 0 — Read all records from the last up to P1 (for INS = ‘B2‘ only)
P1 set to ‘00’ and one or more record handling DO‘7F76’
1 1 1 1 1 0 0 0 INS = ‘B2‘
in the command data field
— Any other value is RFU.
Page 76, 11.3.4
Add the following paragraph before Table 72:
If bits b8 to b1 of P2 are set to 11111000 (i.e. P2 = ‘F8‘), then this command may write multiple
records in different EFs. The command data field contains one or more record handling DO‘7F76‘
each containing one file reference DO‘51‘ and one or more sets of an integer DO‘02‘ and a
discretionary data DO‘53‘. The value field of DO‘51‘ contains a file identifier or a short EF identifier
indicating the record structure EF under current DF. This field also may contain a relative path or
an absolute path. The value field of DO‘02‘ is a target record number in the file referenced by DO‘51‘.
The value field of DO‘53‘ is the record to be written. DO‘02‘ may indicate record number over 254.
This command can be performed only when all addressed records are stored in record structure
EF(s), addressed records are present and activated, and when the security status satisfies the
security attributes. If at least one addressed record is not written, any of addressed record is not
written. The VA and the record pointer shall not be changed in case P2 = ‘F8‘.
Page 76, Table 72
Replace one row ’Data field‘ which is command data field with the following:
Bits b8 to b1 of P2 set to 11111000 One or more record handling DO‘7F76‘
Data field
Bits b8 to b1 of P2 not set to
Record to be written
11111000
Page 76, Table 73
Replace Table 73 and its title with the following:
© ISO/IEC 2018 – All rights reserved 3

---------------------- Page: 6 ----------------------
ISO/IEC 7816-4:2013/Amd.1:2018(E)

Table 73 — Coding of P2 in the WRITE RECORD command and the UPDATE RECORD command
with even INS code
b8 b7 b6 b5 b4 b3 b2 b1 Meaning
x x x x x
— — — Short EF identifier according to Table 69
(Not all one)
0 x x P1 set to ‘00‘
0 0 0 — First record
Not all one 0 0 1 — Last record
0 1 0 — Next record
0 1 1 — Previous record
Not all one 1 0 0 Record number in P1
P1 set to ‘00‘ and one or more record handling DO‘7F76’ in the
1 1 1 1 1 0 0 0
command data field
— Any other value is RFU.
Page 77, 11.3.5
Add the following paragraph before Table 74:
If INS = ‘DC‘ and bits b8 to b1 of P2 are set to 11111000 (i.e. P2 = ‘F8‘), then this command may update
multiple records in different EFs. The command data field contains one or more record handling
DO‘7F76‘ each containing one file reference DO‘51‘ and one or more sets of an integer DO‘02‘ and a
discretionary data DO‘53‘. The value field of DO‘51‘ contains a file identifier or a short EF identifier
indicating the record structure EF under current DF. This field also may contain a relative path or
an absolute path. The value field of DO‘02‘ is a target record number in the file referenced by DO‘51‘.
The value field in DO‘53‘ is the updating data for the target record. DO‘02‘ may indicate record
number over 254. This command can be performed only when all addressed records are stored in
record structure EF(s), addressed records are present and activated, and when the security status
satisfies the security attributes. If at least one addressed record is not updated, any of addressed
record is not updated. The VA and the record pointer shall not be changed in case P2 = ‘F8‘.
Page 77, Table 74
Replace one row ‘Data field‘ which is command data field with the following:
INS = ‘DC‘ and bits b8 to b1 of P2 set to
One or more record handling DO‘7F76‘
11111000
INS = ‘DC‘ and bits b8 to b1 of P2 not set to
Data field Updating data
11111000
Offsets DO and discretionary DO for
INS = ‘DD‘
encapsulating the updating data
Page 78, 11.3.6
Add the following paragraph before Table 76:
If bits b8 to b1 of P2 are set to 11111000 (i.e. P2 = ‘F8‘), then this command may append multiple
records to different EFs. The command data field contains one or more record handling DO‘7F76‘
containing one file reference DO‘51‘ and one or more discretionary data DO‘53‘. The value field of
DO‘51‘ contains a file identifier or a short EF identifier indicating the record structure EF under
current DF. This field also may contain a relative path or an absolute path. The value field of DO‘53‘ is
the record to be appended. This command can be performed only when all addressed EFs are record
structure and have enough space for appending record, and when the security status satisfies the
security attributes. If at least one of the records is not appended, any of records is not appended to
the addressed EFs. The VA and the record pointer shall not be changed in case P2 = ‘F8‘.
4 © ISO/IEC 2018 – All rights reserved

---------------------- Page: 7 ----------------------
ISO/IEC 7816-4:2013/Amd.1:2018(E)

Page 78, Table 76
Replace the row ’P2‘ with the following:
P2 See Table Amd.1-1
Page 78, Table 76
Replace one row ’Data field‘ which is command data field with the following:
Bits b8 to b1 of P2 set to 11111000 One or more record handling DO‘7F76‘
Data field
Bits b8 to b1 of P2 not set to
Record to be appended
11111000
Page 78
Add the following table after Table 76:
Table — Amd.1-1 — Coding of P2 in the APPEND RECORD command
b8 b7 b6 b5 b4 b3 b2 b1 Meaning
x x x x x
— — — Short EF identifier according to Table 69
(Not all one)
Not all one 0 0 0 Command data field containing record to be appended
1 1 1 1 1 0 0 0 One or more record handling DO‘7F76‘
— Any other value is RFU.
Page 78, 11.3.7
Replace the first sentence with the following:
If bits b8 to b1 of P2 are not set to 11111000 (i.e. P2 = ‘F8‘), this command initiates a simple or
enhanced or proprietary search on records stored within one addressed EF.
Page 78, 11.3.7
Add the following paragraph after the first paragraph:
If bits b8 to b1 of P2 are set to 11111000 (i.e. P2 = ‘F8‘), this command initiates a search on records
stored within one or more addressed EFs (search through multiple EFs). Two options are provided
for search through multiple EFs such as simple and enhanced search through multiple EFs. The
command data field contains one record handling DO‘7F76‘. The search covers all activated records
in all the EFs addressed by file reference DOs. The response data field gives one or more record
handling DO‘7F76‘ each containing one file reference DO‘51‘ with one or more integer DO‘02‘. DO‘51‘
gives file reference to an EF storing the record matching the search criteria. Value field of DO‘02‘ is
the record number indicating the record matching the search criteria. DO‘02‘ may indicate record
number over 254. This command can be performed on each activated record
...