ISO 15118-4:2018
(Main)Road vehicles — Vehicle to grid communication interface — Part 4: Network and application protocol conformance test
Road vehicles — Vehicle to grid communication interface — Part 4: Network and application protocol conformance test
ISO 15118-4:2018 specifies conformance tests in the form of an Abstract Test Suite (ATS) for a System Under Test (SUT) implementing an EVCC or SECC according to ISO 15118-2. These conformance tests specify the testing of capabilities and behaviors of an SUT as well as checking what is observed against the conformance requirements specified in ISO 15118-2 and against what the supplier states the SUT implementation's capabilities are. The capability tests within the ATS check that the observable capabilities of the SUT are in accordance with the static conformance requirements defined in ISO 15118-2. The behavior tests of the ATS examine an implementation as thoroughly as is practical over the full range of dynamic conformance requirements defined in ISO 15118-2 and within the capabilities of the SUT (see NOTE). A test architecture is described in correspondence to the ATS. The conformance test cases in this document are described leveraging this test architecture and are specified in TTCN-3 Core Language for ISO/OSI Network Layer (Layer 3) and above. The conformance test cases for the Data Link Layer (Layer 2) and Physical Layer (Layer 1) are described in ISO 15118-5. Test cases with overlapping scopes are explicitly detailed. This document does not include specific tests of other standards referenced within ISO 15118-2, e.g. IETF RFCs. Furthermore, the conformance tests specified in this document do not include the assessment of performance nor robustness or reliability of an implementation. They cannot provide judgments on the physical realization of abstract service primitives, how a system is implemented, how it provides any requested service, nor the environment of the protocol implementation. Furthermore, the test cases defined in this document only consider the communication protocol defined ISO 15118-2. Power flow between the EVSE and the EV is not considered. NOTE 1 Practical limitations make it impossible to define an exhaustive test suite, and economic considerations can restrict testing even further. Hence, the purpose of this document is to increase the probability that different implementations are able to interwork. This is achieved by verifying them by means of a protocol test suite, thereby increasing the confidence that each implementation conforms to the protocol specification. However, the specified protocol test suite cannot guarantee conformance to the specification since it detects errors rather than their absence. Thus conformance to a test suite alone cannot guarantee interworking. What it does do is give confidence that an implementation has the required capabilities and that its behavior conforms consistently in representative instances of communication. NOTE 2 This document has some interdependencies to the conformance tests defined in ISO 15118-5 which result from ISO/OSI cross layer dependencies in the underlying protocol specification (e.g. for sleep mode)
Véhicules routiers — Interface de communication entre véhicule et réseau électrique — Partie 4: Essai de conformité du protocole d'application et du réseau
Le présent document spécifie des tests de conformité sous la forme d'une suite de tests abstraits (ATS) pour un système à tester (SUT) implémentant un EVCC ou un SECC conformément à la norme ISO 15118-2. Ces tests de conformité spécifient le contrôle des capacités et des comportements d'un SUT ainsi que la vérification de ce qui est observé en comparaison des exigences de conformité spécifiées dans la norme ISO 15118-2 et en comparaison des capacités de l'implémentation du SUT formulées par le fournisseur. Les tests de capacités compris dans l'ATS vérifient que les capacités observables du SUT sont conformes aux exigences de conformité statiques définies dans la norme ISO 15118-2. Les tests de comportement de l'ATS examinent une implémentation de la manière la plus approfondie possible sur l'ensemble de l'éventail des exigences de conformité dynamiques définies dans la norme ISO 15118-2 et dans les limites des capacités du SUT (voir NOTE). Une architecture de test est décrite en rapport avec l'ATS. Dans le présent document, les cas de test de conformité sont décrits en s'appuyant sur cette architecture de test et sont spécifiés en langage noyau TTCN-3 pour la couche réseau (Couche 3) ISO/OSI et supérieures. Les cas de test de conformité pour la couche liaison de données (Couche 2) et la couche physique (Couche 1) sont décrits dans la norme ISO 15118-5. Des cas de test dont les domaines d'application se recoupent sont détaillés de manière explicite. Le présent document n'inclut pas les tests spécifiques d'autres normes données en référence dans la norme ISO 15118-2, par ex., les RFC de l'IETF. En outre, les tests de conformité spécifiés dans le présent document n'incluent pas l'évaluation du rendement, de la robustesse ou encore de la fiabilité d'une implémentation. Ils ne peuvent servir à la formulation de jugements sur la réalisation physique de primitives de service abstraites, sur la manière dont un système est implémenté, sur la manière dont il fournit un quelconque service requis, ou sur l'environnement de l'implémentation du protocole. En outre, les cas de test définis dans le présent document prennent uniquement en considération le protocole de communication défini dans la norme ISO 15118-2. Le flux d'énergie entre l'EVSE et l'EV n'est pas pris en compte. NOTE 1 Les limitations pratiques empêchent la définition d'une suite de tests exhaustive, et des considérations économiques peuvent restreindre le test encore davantage. Par conséquent, le présent document a pour but d'accroître la probabilité d'interopérabilité de différentes implémentations. Cela est réalisé en les vérifiant au moyen d'une suite de tests de protocole qui permet ainsi d'augmenter la certitude selon laquelle chaque implémentation est conforme à la spécification du protocole. Cependant, la suite de tests de protocole spécifiée ne peut garantir une conformité à la spécification étant donné qu'elle détecte les erreurs plutôt que leur absence. Par conséquent, la conformité d'une suite de tests ne peut garantir à elle seule une interopérabilité. En revanche, cela apporte la garantie qu'une implémentation présente les capacités requises et que son comportement est systématiquement conforme dans des instances représentatives de communication. NOTE 2 Le présent document présente certaines interdépendances avec les tests de conformité définis dans la norme ISO 15118-5 qui découlent de dépendances inter-couches ISO/OSI dans la spécification du protocole sous-jacent (par ex., pour un mode veille)
General Information
Buy Standard
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 15118-4
First edition
2018-02
Road vehicles — Vehicle to grid
communication interface —
Part 4:
Network and application protocol
conformance test
Véhicules routiers — Interface de communication entre véhicule et
réseau électrique —
Partie 4: Essai de conformité du protocole d'application et du réseau
Reference number
©
ISO 2018
© ISO 2018
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2018 – All rights reserved
Contents Page
Foreword . vii
Introduction . viii
1 Scope . 1
2 Normative references . 2
3 Terms and definitions . 2
4 Symbols (and abbreviated terms) . 7
5 Conventions . 8
5.1 Requirement structure . 8
5.2 Test system description . 9
6 Test architecture reference model . 9
6.1 General information . 9
6.2 Platform adapter interface . 10
6.3 SUT adapter interfaces . 10
............................................................................................................................................................... 11
6.4 Codecs
7 Test suite conventions . 11
7.1 General information . 11
7.2 Test suite structure (TSS) . 11
7.3 Test profiles . 13
7.4 Test suite identifiers . 62
7.5 Test suite coverage . 67
7.6 Test case description . 184
7.7 Test case specification . 185
8 Test case descriptions for 15118-2 V2GTP . 198
8.1 General information . 198
8.2 SECC test cases . 198
8.3 EVCC test cases . 202
9 Test case descriptions for 15118-2 SDP messages . 208
9.1 General information . 208
9.2 SECC test cases . 208
9.3 EVCC test cases . 211
10 Test case descriptions for 15118-2 V2G application layer messages . 236
10.1 General information . 236
10.2 SECC test cases . 236
10.3 EVCC test cases . 405
Annex A (normative) Configuration specifications . 671
A.1 Timer configuration . 671
A.2 PICS configuration . 671
iii
© ISO 2018 ‐ All rights reserved
A.3 PIXIT configuration . 673
Annex B (normative) Control part specification . 675
B.1 SECC control parts . 675
B.1.1 AC specific control parts . 675
B.1.2 DC specific control parts . 675
B.2 EVCC control parts . 688
B.2.1 AC specific control parts . 702
B.2.2 DC specific control parts . 702
Annex C (normative) Test-case specifications for 15118-2 V2GTP . 745
C.1 SECC test cases . 745
C.2 EVCC test cases . 745
Annex D (normative) Test-case specifications for 15118-2 SDP messages . 752
D.1 SECC test cases . 752
D.2 EVCC test cases . 752
Annex E (normative) Test-case specifications for 15118-2 V2G application layer messages . 773
E.1 SECC test cases . 773
E.1.1 V2G protocol handshake . 773
E.1.1.1 SECC test cases for SupportedAppProtocol . 773
E.1.2 V2G messages . 773
E.1.2.1 SECC test cases for SessionSetup . 775
E.1.2.2 SECC test cases for ServiceDiscovery . 775
E.1.2.3 SECC test cases for ServiceDetail . 782
E.1.2.4 SECC test cases for PaymentServiceSelection . 784
E.1.2.5 SECC test cases for PaymentDetails . 788
E.1.2.6 SECC test cases for Authorization . 794
E.1.2.7 SECC test cases for ChargeParameterDiscovery . 794
E.1.2.8 SECC test cases for PowerDelivery . 799
E.1.2.9 SECC test cases for CertificateUpdat e . 824
E.1.2.10 SECC test cases for CertificateInstallation . 839
E.1.2.11 SECC test cases for SessionStop . 839
E.1.2.12 SECC test cases for ChargingStatus . 842
E.1.2.13 SECC test cases for MeteringReceipt . 846
E.1.2.14 SECC test cases for CableCheck . 848
E.1.2.15 SECC test cases for PreCharge . 852
E.1.2.16 SECC test cases for CurrentDemand . 855
E.1.2.17 SECC test cases for WeldingDetection . 859
E.2 EVCC test cases . 860
Annex F (normative) Function specifications for supporting test execution . 1009
iv
© ISO 2018 ‐ All rights reserved
F.1 Configuration functions . 1009
F.2 Pre-condition functions . 1009
F.2.1 SECC functi ons . 1011
F.2.2 EVCC functions . 1027
F.3 Post-condition functions . 1027
F.3.1 SECC functi ons . 1038
F.3.2 EVCC functions . 1038
F.4 Common behavior functions . 1039
F.4.1 SECC functi ons . 1040
F.4.2 EVCC functions . 1042
F.5 Library functions . 1044
Annex G (normative) Function specifications for 15118-2 V2GTP .
...
INTERNATIONAL ISO
STANDARD 15118-4
First edition
2018-02
Road vehicles — Vehicle to grid
communication interface —
Part 4:
Network and application protocol
conformance test
Véhicules routiers — Interface de communication entre véhicule et
réseau électrique —
Partie 4: Essai de conformité du protocole d'application et du réseau
Reference number
©
ISO 2018
© ISO 2018
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2018 – All rights reserved
Contents Page
Foreword . vii
Introduction . viii
1 Scope . 1
2 Normative references . 2
3 Terms and definitions . 2
4 Symbols (and abbreviated terms) . 7
5 Conventions . 8
5.1 Requirement structure . 8
5.2 Test system description . 9
6 Test architecture reference model . 9
6.1 General information . 9
6.2 Platform adapter interface . 10
6.3 SUT adapter interfaces . 10
............................................................................................................................................................... 11
6.4 Codecs
7 Test suite conventions . 11
7.1 General information . 11
7.2 Test suite structure (TSS) . 11
7.3 Test profiles . 13
7.4 Test suite identifiers . 62
7.5 Test suite coverage . 67
7.6 Test case description . 184
7.7 Test case specification . 185
8 Test case descriptions for 15118-2 V2GTP . 198
8.1 General information . 198
8.2 SECC test cases . 198
8.3 EVCC test cases . 202
9 Test case descriptions for 15118-2 SDP messages . 208
9.1 General information . 208
9.2 SECC test cases . 208
9.3 EVCC test cases . 211
10 Test case descriptions for 15118-2 V2G application layer messages . 236
10.1 General information . 236
10.2 SECC test cases . 236
10.3 EVCC test cases . 405
Annex A (normative) Configuration specifications . 671
A.1 Timer configuration . 671
A.2 PICS configuration . 671
iii
© ISO 2018 ‐ All rights reserved
A.3 PIXIT configuration . 673
Annex B (normative) Control part specification . 675
B.1 SECC control parts . 675
B.1.1 AC specific control parts . 675
B.1.2 DC specific control parts . 675
B.2 EVCC control parts . 688
B.2.1 AC specific control parts . 702
B.2.2 DC specific control parts . 702
Annex C (normative) Test-case specifications for 15118-2 V2GTP . 745
C.1 SECC test cases . 745
C.2 EVCC test cases . 745
Annex D (normative) Test-case specifications for 15118-2 SDP messages . 752
D.1 SECC test cases . 752
D.2 EVCC test cases . 752
Annex E (normative) Test-case specifications for 15118-2 V2G application layer messages . 773
E.1 SECC test cases . 773
E.1.1 V2G protocol handshake . 773
E.1.1.1 SECC test cases for SupportedAppProtocol . 773
E.1.2 V2G messages . 773
E.1.2.1 SECC test cases for SessionSetup . 775
E.1.2.2 SECC test cases for ServiceDiscovery . 775
E.1.2.3 SECC test cases for ServiceDetail . 782
E.1.2.4 SECC test cases for PaymentServiceSelection . 784
E.1.2.5 SECC test cases for PaymentDetails . 788
E.1.2.6 SECC test cases for Authorization . 794
E.1.2.7 SECC test cases for ChargeParameterDiscovery . 794
E.1.2.8 SECC test cases for PowerDelivery . 799
E.1.2.9 SECC test cases for CertificateUpdat e . 824
E.1.2.10 SECC test cases for CertificateInstallation . 839
E.1.2.11 SECC test cases for SessionStop . 839
E.1.2.12 SECC test cases for ChargingStatus . 842
E.1.2.13 SECC test cases for MeteringReceipt . 846
E.1.2.14 SECC test cases for CableCheck . 848
E.1.2.15 SECC test cases for PreCharge . 852
E.1.2.16 SECC test cases for CurrentDemand . 855
E.1.2.17 SECC test cases for WeldingDetection . 859
E.2 EVCC test cases . 860
Annex F (normative) Function specifications for supporting test execution . 1009
iv
© ISO 2018 ‐ All rights reserved
F.1 Configuration functions . 1009
F.2 Pre-condition functions . 1009
F.2.1 SECC functi ons . 1011
F.2.2 EVCC functions . 1027
F.3 Post-condition functions . 1027
F.3.1 SECC functi ons . 1038
F.3.2 EVCC functions . 1038
F.4 Common behavior functions . 1039
F.4.1 SECC functi ons . 1040
F.4.2 EVCC functions . 1042
F.5 Library functions . 1044
Annex G (normative) Function specifications for 15118-2 V2GTP .
...
NORME ISO
INTERNATIONALE 15118-4
Première édition
2018-02
Véhicules routiers — Interface de
communication entre véhicule et
réseau électrique —
Partie 4:
Essai de conformité du protocole
d'application et du réseau
Road vehicles — Vehicle to grid communication interface —
Part 4: Network and application protocol conformance test
Numéro de référence
©
ISO 2018
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2018
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
Fax: +41 22 749 09 47
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii © ISO 2018 – Tous droits réservés
Sommaire Page
Avant-propos . vii
Introduction . viii
1 Domaine d’application . 1
2 Références normatives . 2
3 Termes et définitions . 2
4 Symboles et termes abrégés . 7
5 Conventions . 9
5.1 Structure des exigences . 9
5.2 Description du système de test . 9
6 Modèle de référence d’architecture de test . 9
6.1 Informations générales . 9
6.2 Interface d’adaptateur de plateforme . 10
6.3 Interfaces d’adaptateur du SUT . 10
6.4 Codecs . 11
7 Conventions de la suite de tests . 12
7.1 Informations générales . 12
7.2 Structure de la suite de tests (TSS) . 12
7.3 Profils de test . 14
7.4 Identificateurs de la suite de tests . 61
7.5 Couverture de la suite de tests . 66
7.6 Description de cas de test . 187
7.7 Spécification du cas de test . 188
8 Descriptions de cas de test pour un V2GTP 15118-2 . 201
8.1 Informations générales . 201
8.2 Cas de test de SECC . 202
8.3 Cas de test d’EVCC . 206
9 Descriptions de cas de test pour des messages SDP 15118-2 . 212
mations générales . 212
9.1 Infor
9.2 Cas de test de SECC . 212
9.3 Cas de test d’EVCC . 215
10 Descriptions de cas de test pour les messages de couche d’application V2G 15118-2 . 241
10.1 Informations générales . 241
10.2 Cas de test de SECC . 241
10.3 Cas de test d’EVCC . 422
Annex A (normatif) Spécifications de configuration . 704
A.1 Configuration des temporisateurs . 704
A.2 Configuration de PICS . 705
A.3 Configuration de PIXIT . 706
Annex B (normatif) Spécifications des parties de contrôle . 708
B.1 Parties de contrôle d’un SECC . 708
B.1.1 Parties de contrôle spécifiques à un courant AC . 708
iii
© ISO 2018 ‐ Tous droits réservés
B.1.2 Parties de contrôle spécifiques à un courant DC . 721
B.2 Parties de contrôle d’un EVCC . 735
B.2.1 Parties de contrôle spécifiques à un courant AC . 735
B.2.2 Parties de contrôle spécifiques à un courant DC . 755
Annex C (normatif) Spécifications de cas de test pour un V2GTP 15118-2 . 778
C.1 Cas de test de SECC . 778
C.2 Cas de test d’EVCC. 781
Annex D (normatif) Spécifications de cas de test pour des messages SDP 15118-2 . 785
D.1 Cas de test de SECC . 785
D.2 Cas de test d’EVCC. 787
Annex E (normatif) Spécifications de cas de test pour des messages de couche d’application
V2G 15118-2 . 806
E.1 Cas de test de SECC . 806
E.1.1 Établissement de liaison de protocole V2G . 806
E.1.1.1 Cas de test de SECC pour SupportedAppProtocol . 806
E.1.2 Messages V 2G . 808
E.1.2.1 Cas de test de SECC pour SessionSetup . 808
E.1.2.2 Cas de test de SECC pour ServiceDiscovery . 815
E.1.2.3 Cas de test de SECC pour ServiceDetail . 818
E.1.2.4 Cas de test de SECC pour PaymentServiceSelection . 821
E.1.2.5 Cas de test de SECC pour PaymentDetails . 824
E.1.2.6 Cas de test de SECC pour Authorization . 827
E.1.2.7 SECC test cases for ChargeParameterDiscovery . 832
E.1.2.8 Cas de test de SECC pour PowerDelivery . 857
E.1.2.9 Cas de test de SECC pour CertificateUpdate . 868
E.1.2.10 SECC test cases for CertificateInstallation . 872
E.1.2.11 Cas de test de SECC pour SessionStop . 875
E.1.2.12 Cas de test de SECC pour ChargingStatus . 879
E.1.2.13 Cas de test de SECC pour MeteringReceipt . 881
E.1.2.14 Cas de test de SECC pour CableCheck . 885
E.1.2.15 Cas de test de SECC pour PreCharge . 888
E.1.2.16 Cas de test de SECC pour CurrentDemand . 889
E.1.2.17 Cas de test de SECC pour WeldingDetection . 892
E.2 Cas de test d’EVCC. 893
Annex F (normatif) Spécifications de fonctions pour le soutien de l’exécution du test . 1042
F.1 Fonctions de configuration . 1042
F.2 Fonctions de conditions initiales . 1044
F.2.1 Fonctions de SECC . 1044
F.2.2 Fonctions d’EVCC . 1060
iv
© ISO 2018 ‐ Tous droits réservés
F.3 Fonctions de conditions finales . 1071
F.3.1 Fonctions de SECC . 1071
F.3.2 Fonctions d’ EVCC . 1072
F.4 Fonctions de comportements communs . 1073
F.4.1 Fonctions de SECC . 1073
F.4.2 Fonctions d’ EVCC . 1075
F.5 Fonctions de bibliothèque . 1077
Annex G (normatif) Spécifications de fonctions pour un V2GTP 15118-2 . 1084
G.1 Fonctions de SECC . 1084
G.2 Fonctions d’ EVCC .
...
NORME ISO
INTERNATIONALE 15118-4
Première édition
2018-02
Véhicules routiers — Interface de
communication entre véhicule et
réseau électrique —
Partie 4:
Essai de conformité du protocole
d'application et du réseau
Road vehicles — Vehicle to grid communication interface —
Part 4: Network and application protocol conformance test
Numéro de référence
©
ISO 2018
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2018
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
Fax: +41 22 749 09 47
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii © ISO 2018 – Tous droits réservés
Sommaire Page
Avant-propos . vii
Introduction . viii
1 Domaine d’application . 1
2 Références normatives . 2
3 Termes et définitions . 2
4 Symboles et termes abrégés . 7
5 Conventions . 9
5.1 Structure des exigences . 9
5.2 Description du système de test . 9
6 Modèle de référence d’architecture de test . 9
6.1 Informations générales . 9
6.2 Interface d’adaptateur de plateforme . 10
6.3 Interfaces d’adaptateur du SUT . 10
6.4 Codecs . 11
7 Conventions de la suite de tests . 12
7.1 Informations générales . 12
7.2 Structure de la suite de tests (TSS) . 12
7.3 Profils de test . 14
7.4 Identificateurs de la suite de tests . 61
7.5 Couverture de la suite de tests . 66
7.6 Description de cas de test . 187
7.7 Spécification du cas de test . 188
8 Descriptions de cas de test pour un V2GTP 15118-2 . 201
8.1 Informations générales . 201
8.2 Cas de test de SECC . 202
8.3 Cas de test d’EVCC . 206
9 Descriptions de cas de test pour des messages SDP 15118-2 . 212
mations générales . 212
9.1 Infor
9.2 Cas de test de SECC . 212
9.3 Cas de test d’EVCC . 215
10 Descriptions de cas de test pour les messages de couche d’application V2G 15118-2 . 241
10.1 Informations générales . 241
10.2 Cas de test de SECC . 241
10.3 Cas de test d’EVCC . 422
Annex A (normatif) Spécifications de configuration . 704
A.1 Configuration des temporisateurs . 704
A.2 Configuration de PICS . 705
A.3 Configuration de PIXIT . 706
Annex B (normatif) Spécifications des parties de contrôle . 708
B.1 Parties de contrôle d’un SECC . 708
B.1.1 Parties de contrôle spécifiques à un courant AC . 708
iii
© ISO 2018 ‐ Tous droits réservés
B.1.2 Parties de contrôle spécifiques à un courant DC . 721
B.2 Parties de contrôle d’un EVCC . 735
B.2.1 Parties de contrôle spécifiques à un courant AC . 735
B.2.2 Parties de contrôle spécifiques à un courant DC . 755
Annex C (normatif) Spécifications de cas de test pour un V2GTP 15118-2 . 778
C.1 Cas de test de SECC . 778
C.2 Cas de test d’EVCC. 781
Annex D (normatif) Spécifications de cas de test pour des messages SDP 15118-2 . 785
D.1 Cas de test de SECC . 785
D.2 Cas de test d’EVCC. 787
Annex E (normatif) Spécifications de cas de test pour des messages de couche d’application
V2G 15118-2 . 806
E.1 Cas de test de SECC . 806
E.1.1 Établissement de liaison de protocole V2G . 806
E.1.1.1 Cas de test de SECC pour SupportedAppProtocol . 806
E.1.2 Messages V 2G . 808
E.1.2.1 Cas de test de SECC pour SessionSetup . 808
E.1.2.2 Cas de test de SECC pour ServiceDiscovery . 815
E.1.2.3 Cas de test de SECC pour ServiceDetail . 818
E.1.2.4 Cas de test de SECC pour PaymentServiceSelection . 821
E.1.2.5 Cas de test de SECC pour PaymentDetails . 824
E.1.2.6 Cas de test de SECC pour Authorization . 827
E.1.2.7 SECC test cases for ChargeParameterDiscovery . 832
E.1.2.8 Cas de test de SECC pour PowerDelivery . 857
E.1.2.9 Cas de test de SECC pour CertificateUpdate . 868
E.1.2.10 SECC test cases for CertificateInstallation . 872
E.1.2.11 Cas de test de SECC pour SessionStop . 875
E.1.2.12 Cas de test de SECC pour ChargingStatus . 879
E.1.2.13 Cas de test de SECC pour MeteringReceipt . 881
E.1.2.14 Cas de test de SECC pour CableCheck . 885
E.1.2.15 Cas de test de SECC pour PreCharge . 888
E.1.2.16 Cas de test de SECC pour CurrentDemand . 889
E.1.2.17 Cas de test de SECC pour WeldingDetection . 892
E.2 Cas de test d’EVCC. 893
Annex F (normatif) Spécifications de fonctions pour le soutien de l’exécution du test . 1042
F.1 Fonctions de configuration . 1042
F.2 Fonctions de conditions initiales . 1044
F.2.1 Fonctions de SECC . 1044
F.2.2 Fonctions d’EVCC . 1060
iv
© ISO 2018 ‐ Tous droits réservés
F.3 Fonctions de conditions finales . 1071
F.3.1 Fonctions de SECC . 1071
F.3.2 Fonctions d’ EVCC . 1072
F.4 Fonctions de comportements communs . 1073
F.4.1 Fonctions de SECC . 1073
F.4.2 Fonctions d’ EVCC . 1075
F.5 Fonctions de bibliothèque . 1077
Annex G (normatif) Spécifications de fonctions pour un V2GTP 15118-2 . 1084
G.1 Fonctions de SECC . 1084
G.2 Fonctions d’ EVCC .
...
Questions, Comments and Discussion