Soil quality — Determination of the specific electrical conductivity

Specifies an instrumental method for the routine determination of the specific electrical conductivity in an aqueous extract of soil. The determination is carried out to obtain an indication of the content of water-soluble electrolytes in a soil.

Qualité du sol — Détermination de la conductivité électrique spécifique

La présente Norme internationale prescrit une méthode instrumentale pour la détermination en routine de la conductivité électrique spécifique d'un extrait aqueux de sol. La détermination est effectuée afin d'obtenir une indication sur la teneur en électrolytes hydrosolubles dans un échantillon de sol. La présente Norme internationale est applicable à tout échantillon de sol séché à l'air.

Kakovost tal - Ugotavljanje specifične električne prevodnosti

General Information

Status
Published
Publication Date
21-Sep-1994
Current Stage
9092 - International Standard to be revised
Completion Date
24-Oct-2022

Relations

Buy Standard

Standard
ISO 11265:1994 - Soil quality -- Determination of the specific electrical conductivity
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 11265:1996
English language
4 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
ISO 11265:1994 - Qualité du sol -- Détermination de la conductivité électrique spécifique
French language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL
ISO
STANDARD
11265
First edition
1994-10-01
Soil quality - Determination of the
specific electrical conductivity
Quake du sol - Dhtermina tion de Ia conductivit6 electrique sphcifique
Reference number
ISO 11265:1994(E)

---------------------- Page: 1 ----------------------
ISO 11265:1994(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide
federation of national Standards bodies (ISO member bodies). The work
of preparing International Standards is normally carried out through ISO
technical committees. Esch member body interested in a subject for
which a technical committee has been established has the right to be
represented on that committee. International organizations, governmental
and non-governmental, in liaison with ISO, also take patt in the work. ISO
collaborates closely with the International Electrotechnical Commission
(IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are
circulated to the member bodies for voting. Publication as an International
Standard requires approval by at least 75 % of the member bodies casting
a vote.
International Standard ISO 11265 was prepared by Technical Committee
ISO/TC 190, Soil quality, Subcommittee SC 3, Chemical methods and soil
characteristics.
Annex A of this International Standard is for information only.
0 ISO 1994
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced
or utilized in any form or by any means, electronie or mechanical, including photocopying and
microfilm, without Permission in writing from the publisher.
International Organization for Standardization
Case Postale 56 l CH-l 211 Geneve 20 l Switzerland
Printed in Switzerland
ii

---------------------- Page: 2 ----------------------
INTERNATIONAL STANDARD 0 ISO
ISO 11265:1994(E)
Soil quality - Determination of the specific electrical
conductivity
NOTE 1 For definitions of the concepts used, see
1 Scope
ISO 7888.
This International Standard specifies an instrumental
method for the routine determination of the specific
4 Reagents
electrical conductivity in an aqueous extract of soil.
The determination is carried out to obtain an indication
Use only reagents of recognized analytical grade.
of the content of water-soluble electrolytes in a soil.
This International Standard is applicable to all types
4.1 Water, with a specific electrical conductivity not
of air-dried soil samples.
higher than 0,2 mS/m at 25 “C (grade 2 water ac-
cording to ISO 3696).
2 Normative references
4.2 Potassium chloride solution,
c(KCI) = 0,l mol/l.
The following Standards contain provisions which,
through reference in this text, constitute provisions
Dissolve 7,456 g of potassium chloride, previously
of this International Standard. At the time of publi-
dried for 24 h at 220 “C + IO “C in water (4.1), and
cation, the editions indicated were valid. All Standards
dilute to 1 000 ml at 20°C. The specific electrical
are subject to revision, and Parties to agreements
conductivity of this solution is 1 290 mS/m at 25 “C.
based on this International Standard are encouraged
to investigate the possibility of applying the most re-
4.3 Potassium chloride solution,
cent editions of the Standards indicated below.
c(KCI) = 0,020 0 mol/l.
Members of IEC and ISO maintain registers of cur-
rently valid International Standards.
Pour 200,O ml of the potassium chloride Solution
(4.2) into a 1 000 ml volumetric flask and dilute to
ISO 3696: 1987, Water for analytical laboratory use -
volume with water at 20 “C. The specific electrical
Specification and test methods.
conductivity of this Solution is 277 mS/m at 25 “C.
ISO 7888:1985, Water quality - .Determination of
electrical conductivity.
4.4 Potassium chloride solution,
c(KCI) = 0,010 0 mol/l.
ISO 11464: 1994, Soil quality - Pretreatmen t of sam-
ples for physico-Chemical analyses.
Pour 100,O ml of the potassium chloride Solution
(4.2) into a 1 000 ml volumetric flask and dilute to
volume with water at 20 “C. The specific electrical
3 Principle
conductivity of this Solution is 141 mS/m at 25 “C.
Air-dried soil is extracted with water at 20 “C + 1 “C All the potassium chloride solutions (4.2, 4.3 and
-
at an extraction ratio of 1:5 (m/V), to dissolve the above) used for calibration shall be stored in tightly
electrolytes. The specific electrical conductivity of the sealed bottles which do not release sufficient alkali
filtered extract is measured and the result is corrected or alkali-earth cations to affect the electrical conduc-
to a temperature of 25 “C. tivity of the solutions.
1

---------------------- Page: 3 ----------------------
0 ISO
ISO 11265:1994(E)
NOTES place it in a horizontal Position in the shaking machine
(5.4). Shake for 30 min. Filter directly through a filter
2 Plastics bottles may be suitable.
Paper (5.5). Carry out a blank determination in the
same way. The value of the blank shall not exceed
bottles containing potassiu m Chlorid e solutions,
3 For
1 mS/m. If the value of the blank exceeds this, repeat
Seals a ‘e recommended as glass will weld to the
plastics
the extraction.
bottle.
NOTES
4 The use of commercially available conductivity Standards
is permitted.
6 The volume of filtrate should be just sufficient to per-
form the measurements.
5 Apparatus and glassware
7 An extraction ratio of 1:5 (m/V) is Chosen to ensure that
an extract is obtainable from all soils including those with
5.1 Conductivity meter, fitted with a conductivity
high organic matter contents. Using a smaller ratio, it is
cell, equipped with an adjustable measuring range
hardly possible to obtain an extract for some soils.
setting and (automatic) temperature correction and
having an accuracy of 1 mS/m at 20 “C. Preferably,
8 The extraction should be performed at the Chosen tem-
the conductivity meter should also be equipped with
perature of 20 “C &- IOC, because the solubility of the salts
present depends on the temperature. After the filtration, the
a cell-constant control.
temperature of the extract is allowed to Change. The
measurement is performed with the temperature adjusted
5.2 Analyt
...

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Qualité du sol -- Détermination de la conductivité électrique spécifiqueSoil quality -- Determination of the specific electrical conductivity13.080.20Fizikalne lastnosti talPhysical properties of soilsICS:Ta slovenski standard je istoveten z:ISO 11265:1994SIST ISO 11265:1996en01-oktober-1996SIST ISO 11265:1996SLOVENSKI
STANDARD



SIST ISO 11265:1996



INTERNATIONAL STANDARD ISO 11265 First edition 1994-10-01 Soil quality - Determination of the specific electrical conductivity Quake du sol - Dhtermina tion de Ia conductivit6 electrique sphcifique Reference number ISO 11265:1994(E) SIST ISO 11265:1996



ISO 11265:1994(E) Foreword ISO (the International Organization for Standardization) is a worldwide federation of national Standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Esch member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take patt in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. International Standard ISO 11265 was prepared by Technical Committee ISO/TC 190, Soil quality, Subcommittee SC 3, Chemical methods and soil characteristics. Annex A of this International Standard is for information only. 0 ISO 1994 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronie or mechanical, including photocopying and microfilm, without Permission in writing from the publisher. International Organization for Standardization Case Postale 56 l CH-l 211 Geneve 20 l Switzerland Printed in Switzerland ii SIST ISO 11265:1996



INTERNATIONAL STANDARD 0 ISO ISO 11265:1994(E) Soil quality - Determination of the specific electrical conductivity 1 Scope This International Standard specifies an instrumental method for the routine determination of the specific electrical conductivity in an aqueous extract of soil. The determination is carried out to obtain an indication of the content of water-soluble electrolytes in a soil. This International Standard is applicable to all types of air-dried soil samples. 2 Normative references The following Standards contain provisions which, through reference in this text, constitute provisions of this International Standard. At the time of publi- cation, the editions indicated were valid. All Standards are subject to revision, and Parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most re- cent editions of the Standards indicated below. Members of IEC and ISO maintain registers of cur- rently valid International Standards. ISO 3696: 1987, Water for analytical laboratory use - Specification and test methods. ISO 7888:1985, Water quality - .Determination of electrical conductivity. ISO 11464: 1994, Soil quality - Pretreatmen t of sam- ples for physico-Chemical analyses. 3 Principle Air-dried soil is extracted with water at 20 “C + 1 “C - at an extraction ratio of 1:5 (m/V), to dissolve the electrolytes. The specific electrical conductivity of the filtered extract is measured and the result is corrected to a temperature of 25 “C. NOTE 1 For definitions of the concepts used, see ISO 7888. 4 Reagents Use only reagents of recognized analytical grade. 4.1 Water, with a specific electrical conductivity not higher than 0,2 mS/m at 25 “C (grade 2 water ac- cording to ISO 3696). 4.2 Potassium chloride solution, c(KCI) = 0,l mol/l. Dissolve 7,456 g of potassium chloride, previously dried for 24 h at 220 “C + IO “C in water (4.1), and dilute to 1 000 ml at 20°C. The specific electrical conductivity of this solution is 1 290 mS/m at 25 “C. 4.3 Potassium chloride solution, c(KCI) = 0,020 0 mol/l. Pour 200,O ml of the potassium chloride Solution (4.2) into a 1 000 ml volumetric flask and dilute to volume with water at 20 “C. The specific electrical conductivity of this Solution is 277 mS/m at 25 “C. 4.4 Potassium chloride solution, c(KCI) = 0,010 0 mol/l. Pour 100,O ml of the potassium chloride Solution (4.2) into a 1 000 ml volumetric flask and dilute to volume with water at 20 “C. The specific electrical conductivity of this Solution is 141 mS/m at 25 “C. All the potassium chloride solutions (4.2, 4.3 and above) used for calibration shall be stored in tightly sealed bottles which do not release sufficient alkali or alkali-earth cations to affect the electrical conduc- tivity of the solutions. 1 SIST ISO 11265:1996



ISO 11265:1994(E) 0 ISO NOTES place it in a horizontal Position in the shaking machine (5.4). Shake for 30 min. Filter directly through a filter Paper (5.5). Carry out a blank determination in the same way. The value of the blank shall not exceed 1 mS/m. If the value of the blank exceeds this, repeat the extraction. 2 Plastics bottles may be suitable. 3 For plastics bottle. bottles containing potassiu m Chlorid e solutions, Seals a ‘e recommended as glass will weld to the NOTES 4 The use of commercially available conductivity Standards is permitted. 6 The volume of filtrate should be just sufficient to per- form the measurements. 5 Apparatus and glassware 7 An extraction ratio of 1:5 (m/V) is Chosen to ensure that an extract is obtainable from all soils including those with high organic matter contents. Using a smaller ratio, it is hardly possible to obtain an extract for some soils. 5.1 Conductivity meter, fitted with a conductivity cell, equipped with an adjustable measuring range setting and (automatic) temperature correction and having an accuracy of 1
...

ISO
NORME
INTERNATIONALE 11265
Première édition
1994-I O-OI
- Détermination de la
Qualité du sol
conductivité électrique spécifique
- Determination of the specific electrical conductivity
Soi1 quality
Numéro de référence
ISO 11265:1994(F)

---------------------- Page: 1 ----------------------
ISO 11265:1994(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération
mondiale d’organismes nationaux de normalisation (comités membres de
I’ISO). L’élaboration des Normes internationales est en général confiée aux
comités techniques de I’ISO. Chaque comité membre interesse par une
étude a le droit de faire partie du comité technique creé a cet effet. Les
organisations internationales, gouvernementales et non gouvernemen-
tales, en liaison avec I’ISO participent également aux travaux. L’ISO colla-
bore étroitement avec la Commission électrotechnique internationale (CEI)
en ce qui concerne la normalisation électrotechnique.
Les projets de Normes internationales adoptes par les comités techniques
sont soumis aux comités membres pour vote. Leur publication comme
Normes internationales requiert l’approbation de 75 % au moins des co-
mites membres votants.
La Norme internationale ISO 11265 a éte elaboree par le comite technique
lSO/K 190, Qualit du sol, sous-comite SC 3, Méthodes chimiques et
caractéristiques du sol.
L’annexe A de la présente Norme internationale est donnée uniquement
à titre d’information.
0 60 1994
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publi-
cation ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun pro-
cédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l’accord
écrit de l’éditeur.
Organisation internationale de normalisation
Case Postale 56 l CH-l 211 Genève 20 l Suisse
Imprimé en Suisse

---------------------- Page: 2 ----------------------
NORME INTERNATIONALE 0 ISO BO 11265:1994(F)
Qualité du sol - Détermination de la conductivité
électrique spécifique
spécifique de l’extrait filtre est mesurée et le resultat
1 Domaine d’application
est corrige à une température de 25 OC.
La présente Norme internationale prescrit une mé-
NOTE 1 Pour les définitions des concepts utilisés, voir
thode instrumentale pour la détermination en routine
ISO 7888.
de la conductivité électrique spécifique d’un extrait
aqueux de sol. La détermination est effectuée afin
d’obtenir une indication sur la teneur en électrolytes
4 Réactifs
hydrosolubles dans un échantillon de sol.
Utiliser uniquement des réactifs de qualité analytique
La présente Norme internationale est applicable à tout
reconnue.
échantillon de sol seche a l’air.
4.1 Eau, de conductivité électrique spécifique ne
2 Références normatives dépassant pas 0,2mS/m a 25 “C (eau de qualité 2
conformément à I’ISO 3696).
Les normes suivantes contiennent des dispositions
qui, par suite de la reférence qui en est faite, consti-
4.2 Solution de chlorure de potassium,
tuent des dispositions valables pour la présente
c(KCI) = 0,l mol/l.
Norme internationale. Au moment de la publication,
les éditions indiquées etaient en vigueur. Toute
Dissoudre 7,456 g de chlorure de potassium, préala-
norme est sujette à revision et les parties prenantes
blement séché pendant 24 h à 220 “C & 10 “C dans
des accords fondes sur la présente Norme internatio-
de l’eau (4.1) et diluer à 1 000 ml à 20 “C. La con-
nale sont invitées à rechercher la possibilité d’appli-
ductivité électrique spécifique de cette solution à
quer les éditions les plus récentes des normes
25 “C est de 1 290 mS/m.
indiquées ci-après. Les membres de la CEI et de I’ISO
possèdent le registre des Normes internationales en
de potassium,
4.3 Solution de chlorure
vigueur à un moment donne.
c(KCI) = 0,020 0 mol/l.
ISO 3696:1987, Eau pour laboratoire à usage analy-
Ajouter 2 000 ml de la solution de chlorure de potas-
tique - Spéci fica tion et méthodes d’essai.
sium (4.2) dans une fiole jaugée de 1 000 ml et diluer
au volume avec de l’eau à 20 “C. La conductivité
ISO 7888:1985, Qualité de l’eau - Détermination de
électrique spécifique de cette solution à 25 “C est de
la conductivite électrique.
277 mS/m.
ISO 11464: 1994, Qualité du sol - Prétraitement des
4.4 Solution de chlorure de potassium,
échantillons pour analyses physico-chimiques.
c(KCI) = 0,010 0 mol/l.
Ajouter 100,O ml de la solution de chlorure de potas-
3 Principe
sium (4.2) dans une fiole jaugée de 1 000 ml et diluer
L’échantillon de sol est extrait avec de l’eau à au volume avec de l’eau à 20 “C. La conductivité
20 “C & 1 “C [rapport d’extraction de 1:5 (m/V)], pour électrique spécifique de cette solution à 25 “C est de
dissoudre les électrolytes. La conductivite électrique 141 mS/m.
1

---------------------- Page: 3 ----------------------
ISO 11265:1994(F)
Toutes les solutions de chlorure de potassium (4.2,
7 Procédure
4.3 et ci-dessus) utilisées pour l’étalonnage doivent
être conservées dans des flacons à fermeture étan-
che ne liberant pas suffisamment de métal alcalin ou
7.1 Extraction
de cations alcalino-terreux pour affecter la conducti-
vite électrique des solutions.
Peser 20,OO g de l’échantillon pour laboratoire et
transférer cette quantité dans le flacon (5.6). Ajouter
NOTES
100 ml d’eau (4.1) à 20 “C + 1 “C. Fermer le flacon
-
et le placer à l’horizontale dans l’agitateur mécanique
2 Des flacons en plastique peuvent convenir.
(5.4). Agiter pendant 30 min. Filtrer directement .sur
3 Pour les flacons contenant les solutions de chlorure de
un papier filtre (5.5). De la même manière, effectuer
potassium, une fermeture en plastique est recommandée,
une détermination à blanc. La valeur du blanc ne doit
du fait que le verre risquerait de se souder au flacon.
pas dépasser 1 mS/m. Si la valeur du blanc excède
cette valeur, recommencer l’extraction.
4 On peut utiliser des étalons commerciaux disponibles
pour la conductivité.
NOTES
6 II convient que le volume de filtrat soit juste suffisant
5 Appareillage et verrerie
pour permettre les mesurages.
5.1 Conductimètre, équipé d’une cellule de mesure 7 Pour être sûr d’obtenir des extraits d’un volume suffi-
sant quel que soit le type d’échantillon (y compris ceux à
de la conductivité, d’un système de réglage de la
forte teneur en matières organiques), on choisit un taux
plage de mesure et d’un dispositif de correction (au-
d’extraction de 1:5 (m/V). Pour certains sols, il est prati-
tomatique) de la température, le tout assurant, a une
quement impossible d’obtenir un extrait si on utilise un taux
température de 20 “C, une précision de 1 mS/m. Le
d’extraction plus faible.
conductimètre doit, de préférence, être également
équipé d’un
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.